Revision History: Instrument Data Sheets
Revision History: Instrument Data Sheets
Revision History
    Rev         Name         Date        Checked        Released             Date                             Comments
            GENERAL                                                                                                                                        REV
  TAG NUMBER                                  (Refer Note 1)                220UV810A
  SERVICE                                                                   Sec. Ball Mill 8 Discharge Pump A Suction Isolation
  EQUIPMENT / LINE NUMBER                                                                                               220-750SL-CS5-018                  0
  LINE DESCRIPTION
  INLET - LINE SIZE / SCHEDULE                                              750                                        STD
  OUTLET - LINE SIZE / SCHEDULE                                             750                                        STD
  FLANGE RATING / FACE                                                      ASME B16.47 150#                           Series A FF
  AREA CLASSIFICATION
  P & ID                                                                    P1664-CS0-2220
  STANDARD INSTRUMENT SPECIFICATION                                         P1664-CS0-E021 Electrical, Instrumentation & Control Guidelines
  STANDARD VALVE SPECIFICATION                                              P1664-CS0-E027 Supply and Installation of Valves and Fittings
  LINE ORIENTATION - HORIZONTAL, VERTICAL, OTHER                            Horizontal
           SYSTEM TESTING
  VENDOR TEST DOCUMENT No. (HYDROSTATIC + FUNCTION TEST)
  NON - DESTRUCTIVE TESTING (Specify Nature, If Any)
  NOTES:
  1. 316SS NAMEPLATE STAMPED WITH VALVE TAG NUMBER & SERVICE IN 10mm CHARACTERS SHALL BE ATTACHED VIA STAINLESS STEEL SCREWS
  OR WIRE.
  2. FACTORY FITTED SOLENOID VALVE AND INTERNAL LIMIT SWITCHES OPERATED BY THE ACTUATOR MECHANISM ARE PREFERRED.
       THESE SHALL BE PRE-WIRED AND TERMINATED IN A JUNCTION BOX MOUNTED ON THE VALVE.
                                                                                                                                     220UV810A
  Issued For Construction             0       8/7/2013    MYR         PP     PP
  REVISION DESCRIPTION               REV       DATE       BY         CHK     APPRV                                DOC No. 220UV810A                  REV       0
           SOLENOID CONSTRUCTION
  COIL VOLTAGE / POWER / FREQUENCY                        V/W/Hz       24 VDC                       2 W Max                   NA          0
  INSULATION CLASS
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  ELECTRICAL CONNECTION / DIN PLUG                   YES/NO            SCREWED TERMINALS                          YES
  COIL TYPE / SINGLE, DOUBLE
  CONDUIT ENTRY SIZE or TYPE                              mm           Refer Note 2
  SURGE SUPPRESSION DIODE                                              REQUIRED
  INRUSH CURRENT / HOLDING CURRENT                        mA
  LED INDICATION                                                       REQUIRED
           POSITION SWITCHES
  TAG NUMBERS - OPEN POSITION / CLOSED POSITION                        220ZSO810A                             220ZSC810A                  0
  MANUFACTURER
  MODEL NUMBER                                                         Contact closed at Limit
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  SWITCH TYPE / FORM
  CONTACT RATING - REQUIRED / ACTUAL                      A
  SWITCHED VOLTAGE                                        V            24 VDC
  CONDUIT ENTRY SIZE (mm) / FLYING LEAD LENGTH (m)   (Refer Note 2)    M20        Refer Note 2
  SWITCH LOCATION - CLOSED, OPEN, BOTH, OTHER                          2 (1 closed, 1 Open)
  No. OF SWITCHES
NOTES:
220UV810A
            GENERAL                                                                                                                                        REV
  TAG NUMBER                                  (Refer Note 1)                220UV810B
  SERVICE                                                                   Sec. Ball Mill 8 Discharge Pump B Suction Isolation
  EQUIPMENT / LINE NUMBER                                                                                               220-750SL-CS5-028                  0
  LINE DESCRIPTION
  INLET - LINE SIZE / SCHEDULE                                              750                                        STD
  OUTLET - LINE SIZE / SCHEDULE                                             750                                        STD
  FLANGE RATING / FACE                                                      ASME B16.47 150#                           Series A FF
  AREA CLASSIFICATION
  P & ID                                                                    P1664-CS0-2220
  STANDARD INSTRUMENT SPECIFICATION                                         P1664-CS0-E021 Electrical, Instrumentation & Control Guidelines
  STANDARD VALVE SPECIFICATION                                              P1664-CS0-E027 Supply and Installation of Valves and Fittings
  LINE ORIENTATION - HORIZONTAL, VERTICAL, OTHER                            Horizontal
           SYSTEM TESTING
  VENDOR TEST DOCUMENT No. (HYDROSTATIC + FUNCTION TEST)
  NON - DESTRUCTIVE TESTING (Specify Nature, If Any)
  NOTES:
  1. 316SS NAMEPLATE STAMPED WITH VALVE TAG NUMBER & SERVICE IN 10mm CHARACTERS SHALL BE ATTACHED VIA STAINLESS STEEL SCREWS
  OR WIRE.
  2. FACTORY FITTED SOLENOID VALVE AND INTERNAL LIMIT SWITCHES OPERATED BY THE ACTUATOR MECHANISM ARE PREFERRED.
       THESE SHALL BE PRE-WIRED AND TERMINATED IN A JUNCTION BOX MOUNTED ON THE VALVE.
                                                                                                                                     220UV810B
  Issued For Construction             0       8/7/2013    MYR         PP     PP
  REVISION DESCRIPTION               REV       DATE       BY         CHK     APPRV                                DOC No. 220UV810B                  REV       0
           SOLENOID CONSTRUCTION
  COIL VOLTAGE / POWER / FREQUENCY                        V/W/Hz       24 VDC                       2 W Max                   NA          0
  INSULATION CLASS
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  ELECTRICAL CONNECTION / DIN PLUG                   YES/NO            SCREWED TERMINALS                          YES
  COIL TYPE / SINGLE, DOUBLE
  CONDUIT ENTRY SIZE or TYPE                              mm           Refer Note 2
  SURGE SUPPRESSION DIODE                                              REQUIRED
  INRUSH CURRENT / HOLDING CURRENT                        mA
  LED INDICATION                                                       REQUIRED
           POSITION SWITCHES
  TAG NUMBERS - OPEN POSITION / CLOSED POSITION                        220ZSO810B                             220ZSC810B                  0
  MANUFACTURER
  MODEL NUMBER                                                         Contact closed at Limit
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  SWITCH TYPE / FORM
  CONTACT RATING - REQUIRED / ACTUAL                      A
  SWITCHED VOLTAGE                                        V            24 VDC
  CONDUIT ENTRY SIZE (mm) / FLYING LEAD LENGTH (m)   (Refer Note 2)    M20        Refer Note 2
  SWITCH LOCATION - CLOSED, OPEN, BOTH, OTHER                          2 (1 closed, 1 Open)
  No. OF SWITCHES
NOTES:
220UV810B
            GENERAL                                                                                                                                        REV
  TAG NUMBER                                  (Refer Note 1)                220UV811A
  SERVICE                                                                   Sec. Ball Mill 8 Discharge Pump A Discharge Isolation
  EQUIPMENT / LINE NUMBER                                                                                              220-700SL-CS4-108
  LINE DESCRIPTION
  INLET - LINE SIZE / SCHEDULE                                              700                                        STD
  OUTLET - LINE SIZE / SCHEDULE                                             700                                        STD
  FLANGE RATING / FACE                                                      ASME B16.47 150#                           Series A FF
  AREA CLASSIFICATION
  P & ID                                                                    P1664-CS0-2220
  STANDARD INSTRUMENT SPECIFICATION                                         P1664-CS0-E021 Electrical, Instrumentation & Control Guidelines
  STANDARD VALVE SPECIFICATION                                              P1664-CS0-E027 Supply and Installation of Valves and Fittings
  LINE ORIENTATION - HORIZONTAL, VERTICAL, OTHER                            Horizontal
           SYSTEM TESTING
  VENDOR TEST DOCUMENT No. (HYDROSTATIC + FUNCTION TEST)
  NON - DESTRUCTIVE TESTING (Specify Nature, If Any)
  NOTES:
  1. 316SS NAMEPLATE STAMPED WITH VALVE TAG NUMBER & SERVICE IN 10mm CHARACTERS SHALL BE ATTACHED VIA STAINLESS STEEL SCREWS
  OR WIRE.
  2. FACTORY FITTED SOLENOID VALVE AND INTERNAL LIMIT SWITCHES OPERATED BY THE ACTUATOR MECHANISM ARE PREFERRED.
       THESE SHALL BE PRE-WIRED AND TERMINATED IN A JUNCTION BOX MOUNTED ON THE VALVE.
                                                                                                                                     220UV811A
  Issued For Construction             0      8/7/2013     MYR         PP     PP
  REVISION DESCRIPTION               REV      DATE        BY         CHK     APPRV                                DOC No. 220UV811A                  REV     0
           SOLENOID CONSTRUCTION
  COIL VOLTAGE / POWER / FREQUENCY                        V/W/Hz       24 VDC                       2 W Max                   NA          0
  INSULATION CLASS
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  ELECTRICAL CONNECTION / DIN PLUG                   YES/NO            SCREWED TERMINALS                          YES
  COIL TYPE / SINGLE, DOUBLE
  CONDUIT ENTRY SIZE or TYPE                              mm           Refer Note 2
  SURGE SUPPRESSION DIODE                                              REQUIRED
  INRUSH CURRENT / HOLDING CURRENT                        mA
  LED INDICATION                                                       REQUIRED
           POSITION SWITCHES
  TAG NUMBERS - OPEN POSITION / CLOSED POSITION                        220ZSO811A                             220ZSC811A                  0
  MANUFACTURER
  MODEL NUMBER                                                         Contact closed at Limit
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  SWITCH TYPE / FORM
  CONTACT RATING - REQUIRED / ACTUAL                      A
  SWITCHED VOLTAGE                                        V            24 VDC
  CONDUIT ENTRY SIZE (mm) / FLYING LEAD LENGTH (m)   (Refer Note 2)    M20        Refer Note 2
  SWITCH LOCATION - CLOSED, OPEN, BOTH, OTHER                          2 (1 closed, 1 Open)
  No. OF SWITCHES
NOTES:
220UV811A
            GENERAL                                                                                                                                        REV
  TAG NUMBER                                  (Refer Note 1)                220UV811B
  SERVICE                                                                   Sec. Ball Mill 8 Discharge Pump B Discharge Isolation
  EQUIPMENT / LINE NUMBER                                                                                              220-700SL-CS4-208
  LINE DESCRIPTION
  INLET - LINE SIZE / SCHEDULE                                              700                                        STD
  OUTLET - LINE SIZE / SCHEDULE                                             700                                        STD
  FLANGE RATING / FACE                                                      ASME B16.47 150#                           Series A FF
  AREA CLASSIFICATION
  P & ID                                                                    P1664-CS0-2220
  STANDARD INSTRUMENT SPECIFICATION                                         P1664-CS0-E021 Electrical, Instrumentation & Control Guidelines
  STANDARD VALVE SPECIFICATION                                              P1664-CS0-E027 Supply and Installation of Valves and Fittings
  LINE ORIENTATION - HORIZONTAL, VERTICAL, OTHER                            Horizontal
           SYSTEM TESTING
  VENDOR TEST DOCUMENT No. (HYDROSTATIC + FUNCTION TEST)
  NON - DESTRUCTIVE TESTING (Specify Nature, If Any)
  NOTES:
  1. 316SS NAMEPLATE STAMPED WITH VALVE TAG NUMBER & SERVICE IN 10mm CHARACTERS SHALL BE ATTACHED VIA STAINLESS STEEL SCREWS
  OR WIRE.
  2. FACTORY FITTED SOLENOID VALVE AND INTERNAL LIMIT SWITCHES OPERATED BY THE ACTUATOR MECHANISM ARE PREFERRED.
       THESE SHALL BE PRE-WIRED AND TERMINATED IN A JUNCTION BOX MOUNTED ON THE VALVE.
                                                                                                                                     220UV811B
  Issued For Construction             0      8/7/2013     MYR         PP     PP
  REVISION DESCRIPTION               REV      DATE        BY         CHK     APPRV                                DOC No. 220UV811B                  REV     0
           SOLENOID CONSTRUCTION
  COIL VOLTAGE / POWER / FREQUENCY                        V/W/Hz       24 VDC                       2 W Max                   NA          0
  INSULATION CLASS
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  ELECTRICAL CONNECTION / DIN PLUG                   YES/NO            SCREWED TERMINALS                          YES
  COIL TYPE / SINGLE, DOUBLE
  CONDUIT ENTRY SIZE or TYPE                              mm           Refer Note 2
  SURGE SUPPRESSION DIODE                                              REQUIRED
  INRUSH CURRENT / HOLDING CURRENT                        mA
  LED INDICATION                                                       REQUIRED
           POSITION SWITCHES
  TAG NUMBERS - OPEN POSITION / CLOSED POSITION                        220ZSO811B                             220ZSC811B                  0
  MANUFACTURER
  MODEL NUMBER                                                         Contact closed at Limit
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  SWITCH TYPE / FORM
  CONTACT RATING - REQUIRED / ACTUAL                      A
  SWITCHED VOLTAGE                                        V            24 VDC
  CONDUIT ENTRY SIZE (mm) / FLYING LEAD LENGTH (m)   (Refer Note 2)    M20        Refer Note 2
  SWITCH LOCATION - CLOSED, OPEN, BOTH, OTHER                          2 (1 closed, 1 Open)
  No. OF SWITCHES
NOTES:
220UV811B
Instrument Service: Sec. Ball Mill 8 Discharge Pump A Drain Isolation Plant Area: 220- Secondary Grinding
            GENERAL                                                                                                                                           REV
  TAG NUMBER                                  (Refer Note 1)                     220UV812A
  SERVICE                                                                        Sec. Ball Mill 8 Discharge Pump A Drain Isolation
  EQUIPMENT / LINE NUMBER
  LINE DESCRIPTION
  INLET - LINE SIZE / SCHEDULE                                                   300                                         STD                              0
  OUTLET - LINE SIZE / SCHEDULE                                                  300                                         STD                              0
  FLANGE RATING / FACE                                                           ASME B16.5 150#                             FF
  AREA CLASSIFICATION
  P & ID                                                                         P1664-CS0-2220
  STANDARD INSTRUMENT SPECIFICATION                                              P1664-CS0-E021 Electrical, Instrumentation & Control Guidelines
  STANDARD VALVE SPECIFICATION                                                   P1664-CS0-E027 Supply and Installation of Valves and Fittings
  LINE ORIENTATION - HORIZONTAL, VERTICAL, OTHER                                 Vertical
           SYSTEM TESTING
  VENDOR TEST DOCUMENT No. (HYDROSTATIC + FUNCTION TEST)
  NON - DESTRUCTIVE TESTING (Specify Nature, If Any)
  NOTES:
  1. 316SS NAMEPLATE STAMPED WITH VALVE TAG NUMBER & SERVICE IN 10mm CHARACTERS SHALL BE ATTACHED VIA STAINLESS STEEL SCREWS
  OR WIRE.
  2. FACTORY FITTED SOLENOID VALVE AND INTERNAL LIMIT SWITCHES OPERATED BY THE ACTUATOR MECHANISM ARE PREFERRED.
       THESE SHALL BE PRE-WIRED AND TERMINATED IN A JUNCTION BOX MOUNTED ON THE VALVE.
                                                                                                                                        220UV812A
  Issued For Construction             0       8/7/2013     MYR         PP         PP
  REVISION DESCRIPTION               REV       DATE        BY         CHK         APPRV                                 DOC No. 220UV812A               REV       0
           SOLENOID CONSTRUCTION
  COIL VOLTAGE / POWER / FREQUENCY                        V/W/Hz       24 VDC                       2 W Max                   NA          0
  INSULATION CLASS
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  ELECTRICAL CONNECTION / DIN PLUG                   YES/NO            SCREWED TERMINALS                          YES
  COIL TYPE / SINGLE, DOUBLE
  CONDUIT ENTRY SIZE or TYPE                              mm           Refer Note 2
  SURGE SUPPRESSION DIODE                                              REQUIRED
  INRUSH CURRENT / HOLDING CURRENT                        mA
  LED INDICATION                                                       REQUIRED
           POSITION SWITCHES
  TAG NUMBERS - OPEN POSITION / CLOSED POSITION                        220ZSO812A                             220ZSC812A                  0
  MANUFACTURER
  MODEL NUMBER                                                         Contact closed at Limit
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  SWITCH TYPE / FORM
  CONTACT RATING - REQUIRED / ACTUAL                      A
  SWITCHED VOLTAGE                                        V            24 VDC
  CONDUIT ENTRY SIZE (mm) / FLYING LEAD LENGTH (m)   (Refer Note 2)    M20        Refer Note 2
  SWITCH LOCATION - CLOSED, OPEN, BOTH, OTHER                          2 (1 closed, 1 Open)
  No. OF SWITCHES
NOTES:
220UV812A
Instrument Service: Sec. Ball Mill 8 Discharge Pump B Drain Isolation Plant Area: 220- Secondary Grinding
            GENERAL                                                                                                                                           REV
  TAG NUMBER                                  (Refer Note 1)                     220UV812B
  SERVICE                                                                        Sec. Ball Mill 8 Discharge Pump B Drain Isolation
  EQUIPMENT / LINE NUMBER
  LINE DESCRIPTION
  INLET - LINE SIZE / SCHEDULE                                                   300                                         STD                              0
  OUTLET - LINE SIZE / SCHEDULE                                                  300                                         STD                              0
  FLANGE RATING / FACE                                                           ASME B16.5 150#                             FF
  AREA CLASSIFICATION
  P & ID                                                                         P1664-CS0-2220
  STANDARD INSTRUMENT SPECIFICATION                                              P1664-CS0-E021 Electrical, Instrumentation & Control Guidelines
  STANDARD VALVE SPECIFICATION                                                   P1664-CS0-E027 Supply and Installation of Valves and Fittings
  LINE ORIENTATION - HORIZONTAL, VERTICAL, OTHER                                 Vertical
           SYSTEM TESTING
  VENDOR TEST DOCUMENT No. (HYDROSTATIC + FUNCTION TEST)
  NON - DESTRUCTIVE TESTING (Specify Nature, If Any)
  NOTES:
  1. 316SS NAMEPLATE STAMPED WITH VALVE TAG NUMBER & SERVICE IN 10mm CHARACTERS SHALL BE ATTACHED VIA STAINLESS STEEL SCREWS
  OR WIRE.
  2. FACTORY FITTED SOLENOID VALVE AND INTERNAL LIMIT SWITCHES OPERATED BY THE ACTUATOR MECHANISM ARE PREFERRED.
       THESE SHALL BE PRE-WIRED AND TERMINATED IN A JUNCTION BOX MOUNTED ON THE VALVE.
                                                                                                                                        220UV812B
  Issued For Construction             0       8/7/2013     MYR         PP         PP
  REVISION DESCRIPTION               REV       DATE        BY         CHK         APPRV                                 DOC No. 220UV812B               REV       0
           SOLENOID CONSTRUCTION
  COIL VOLTAGE / POWER / FREQUENCY                        V/W/Hz       24 VDC                       2 W Max                   NA          0
  INSULATION CLASS
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  ELECTRICAL CONNECTION / DIN PLUG                   YES/NO            SCREWED TERMINALS                          YES
  COIL TYPE / SINGLE, DOUBLE
  CONDUIT ENTRY SIZE or TYPE                              mm           Refer Note 2
  SURGE SUPPRESSION DIODE                                              REQUIRED
  INRUSH CURRENT / HOLDING CURRENT                        mA
  LED INDICATION                                                       REQUIRED
           POSITION SWITCHES
  TAG NUMBERS - OPEN POSITION / CLOSED POSITION                        220ZSO812B                             220ZSC812B                  0
  MANUFACTURER
  MODEL NUMBER                                                         Contact closed at Limit
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  SWITCH TYPE / FORM
  CONTACT RATING - REQUIRED / ACTUAL                      A
  SWITCHED VOLTAGE                                        V            24 VDC
  CONDUIT ENTRY SIZE (mm) / FLYING LEAD LENGTH (m)   (Refer Note 2)    M20        Refer Note 2
  SWITCH LOCATION - CLOSED, OPEN, BOTH, OTHER                          2 (1 closed, 1 Open)
  No. OF SWITCHES
NOTES:
220UV812B
            GENERAL                                                                                                                                        REV
  TAG NUMBER                                  (Refer Note 1)                220UV910A
  SERVICE                                                                   Sec. Ball Mill 9 Discharge Pump A Suction Isolation
  EQUIPMENT / LINE NUMBER                                                                                               220-750SL-CS5-019                  0
  LINE DESCRIPTION
  INLET - LINE SIZE / SCHEDULE                                              750                                        STD
  OUTLET - LINE SIZE / SCHEDULE                                             750                                        STD
  FLANGE RATING / FACE                                                      ASME B16.47 150#                           Series A FF
  AREA CLASSIFICATION
  P & ID                                                                    P1664-CS0-2230
  STANDARD INSTRUMENT SPECIFICATION                                         P1664-CS0-E021 Electrical, Instrumentation & Control Guidelines
  STANDARD VALVE SPECIFICATION                                              P1664-CS0-E027 Supply and Installation of Valves and Fittings
  LINE ORIENTATION - HORIZONTAL, VERTICAL, OTHER                            Horizontal
           SYSTEM TESTING
  VENDOR TEST DOCUMENT No. (HYDROSTATIC + FUNCTION TEST)
  NON - DESTRUCTIVE TESTING (Specify Nature, If Any)
  NOTES:
  1. 316SS NAMEPLATE STAMPED WITH VALVE TAG NUMBER & SERVICE IN 10mm CHARACTERS SHALL BE ATTACHED VIA STAINLESS STEEL SCREWS
  OR WIRE.
  2. FACTORY FITTED SOLENOID VALVE AND INTERNAL LIMIT SWITCHES OPERATED BY THE ACTUATOR MECHANISM ARE PREFERRED.
       THESE SHALL BE PRE-WIRED AND TERMINATED IN A JUNCTION BOX MOUNTED ON THE VALVE.
                                                                                                                                     220UV910A
  Issued For Construction             0       8/7/2013    MYR         PP     PP
  REVISION DESCRIPTION               REV       DATE       BY         CHK     APPRV                                DOC No. 220UV910A                  REV       0
           SOLENOID CONSTRUCTION
  COIL VOLTAGE / POWER / FREQUENCY                        V/W/Hz       24 VDC                       2 W Max                   NA          0
  INSULATION CLASS
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  ELECTRICAL CONNECTION / DIN PLUG                   YES/NO            SCREWED TERMINALS                          YES
  COIL TYPE / SINGLE, DOUBLE
  CONDUIT ENTRY SIZE or TYPE                              mm           Refer Note 2
  SURGE SUPPRESSION DIODE                                              REQUIRED
  INRUSH CURRENT / HOLDING CURRENT                        mA
  LED INDICATION                                                       REQUIRED
           POSITION SWITCHES
  TAG NUMBERS - OPEN POSITION / CLOSED POSITION                        220ZSO910A                             220ZSC910A                  0
  MANUFACTURER
  MODEL NUMBER                                                         Contact closed at Limit
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  SWITCH TYPE / FORM
  CONTACT RATING - REQUIRED / ACTUAL                      A
  SWITCHED VOLTAGE                                        V            24 VDC
  CONDUIT ENTRY SIZE (mm) / FLYING LEAD LENGTH (m)   (Refer Note 2)    M20        Refer Note 2
  SWITCH LOCATION - CLOSED, OPEN, BOTH, OTHER                          2 (1 closed, 1 Open)
  No. OF SWITCHES
NOTES:
220UV910A
            GENERAL                                                                                                                                        REV
  TAG NUMBER                                  (Refer Note 1)                220UV910B
  SERVICE                                                                   Sec. Ball Mill 9 Discharge Pump B Suction Isolation
  EQUIPMENT / LINE NUMBER                                                                                               220-750SL-CS5-029                  0
  LINE DESCRIPTION
  INLET - LINE SIZE / SCHEDULE                                              750                                        STD
  OUTLET - LINE SIZE / SCHEDULE                                             750                                        STD
  FLANGE RATING / FACE                                                      ASME B16.47 150#                           Series A FF
  AREA CLASSIFICATION
  P & ID                                                                    P1664-CS0-2230
  STANDARD INSTRUMENT SPECIFICATION                                         P1664-CS0-E021 Electrical, Instrumentation & Control Guidelines
  STANDARD VALVE SPECIFICATION                                              P1664-CS0-E027 Supply and Installation of Valves and Fittings
  LINE ORIENTATION - HORIZONTAL, VERTICAL, OTHER                            Horizontal
           SYSTEM TESTING
  VENDOR TEST DOCUMENT No. (HYDROSTATIC + FUNCTION TEST)
  NON - DESTRUCTIVE TESTING (Specify Nature, If Any)
  NOTES:
  1. 316SS NAMEPLATE STAMPED WITH VALVE TAG NUMBER & SERVICE IN 10mm CHARACTERS SHALL BE ATTACHED VIA STAINLESS STEEL SCREWS
  OR WIRE.
  2. FACTORY FITTED SOLENOID VALVE AND INTERNAL LIMIT SWITCHES OPERATED BY THE ACTUATOR MECHANISM ARE PREFERRED.
       THESE SHALL BE PRE-WIRED AND TERMINATED IN A JUNCTION BOX MOUNTED ON THE VALVE.
                                                                                                                                     220UV910B
  Issued For Construction             0      8/7/2013     MYR         PP     PP
  REVISION DESCRIPTION               REV      DATE        BY         CHK     APPRV                                DOC No. 220UV910B                  REV       0
           SOLENOID CONSTRUCTION
  COIL VOLTAGE / POWER / FREQUENCY                        V/W/Hz       24 VDC                       2 W Max                   NA          0
  INSULATION CLASS
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  ELECTRICAL CONNECTION / DIN PLUG                   YES/NO            SCREWED TERMINALS                          YES
  COIL TYPE / SINGLE, DOUBLE
  CONDUIT ENTRY SIZE or TYPE                              mm           Refer Note 2
  SURGE SUPPRESSION DIODE                                              REQUIRED
  INRUSH CURRENT / HOLDING CURRENT                        mA
  LED INDICATION                                                       REQUIRED
           POSITION SWITCHES
  TAG NUMBERS - OPEN POSITION / CLOSED POSITION                        220ZSO910B                             220ZSC910B                  0
  MANUFACTURER
  MODEL NUMBER                                                         Contact closed at Limit
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  SWITCH TYPE / FORM
  CONTACT RATING - REQUIRED / ACTUAL                      A
  SWITCHED VOLTAGE                                        V            24 VDC
  CONDUIT ENTRY SIZE (mm) / FLYING LEAD LENGTH (m)   (Refer Note 2)    M20        Refer Note 2
  SWITCH LOCATION - CLOSED, OPEN, BOTH, OTHER                          2 (1 closed, 1 Open)
  No. OF SWITCHES
NOTES:
220UV910B
            GENERAL                                                                                                                                        REV
  TAG NUMBER                                  (Refer Note 1)                220UV911A
  SERVICE                                                                   Sec. Ball Mill 9 Discharge Pump A Discharge Isolation
  EQUIPMENT / LINE NUMBER                                                                                              220-700SL-CS4-109
  LINE DESCRIPTION
  INLET - LINE SIZE / SCHEDULE                                              700                                        STD
  OUTLET - LINE SIZE / SCHEDULE                                             700                                        STD
  FLANGE RATING / FACE                                                      ASME B16.47 150#                           Series A FF
  AREA CLASSIFICATION
  P & ID                                                                    P1664-CS0-2230
  STANDARD INSTRUMENT SPECIFICATION                                         P1664-CS0-E021 Electrical, Instrumentation & Control Guidelines
  STANDARD VALVE SPECIFICATION                                              P1664-CS0-E027 Supply and Installation of Valves and Fittings
  LINE ORIENTATION - HORIZONTAL, VERTICAL, OTHER                            Horizontal
           SYSTEM TESTING
  VENDOR TEST DOCUMENT No. (HYDROSTATIC + FUNCTION TEST)
  NON - DESTRUCTIVE TESTING (Specify Nature, If Any)
  NOTES:
  1. 316SS NAMEPLATE STAMPED WITH VALVE TAG NUMBER & SERVICE IN 10mm CHARACTERS SHALL BE ATTACHED VIA STAINLESS STEEL SCREWS
  OR WIRE.
  2. FACTORY FITTED SOLENOID VALVE AND INTERNAL LIMIT SWITCHES OPERATED BY THE ACTUATOR MECHANISM ARE PREFERRED.
       THESE SHALL BE PRE-WIRED AND TERMINATED IN A JUNCTION BOX MOUNTED ON THE VALVE.
                                                                                                                                     220UV911A
  Issued For Construction             0      8/7/2013     MYR         PP     PP
  REVISION DESCRIPTION               REV      DATE        BY         CHK     APPRV                                DOC No. 220UV911A                  REV     0
           SOLENOID CONSTRUCTION
  COIL VOLTAGE / POWER / FREQUENCY                        V/W/Hz       24 VDC                       2 W Max                   NA          0
  INSULATION CLASS
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  ELECTRICAL CONNECTION / DIN PLUG                   YES/NO            SCREWED TERMINALS                          YES
  COIL TYPE / SINGLE, DOUBLE
  CONDUIT ENTRY SIZE or TYPE                              mm           Refer Note 2
  SURGE SUPPRESSION DIODE                                              REQUIRED
  INRUSH CURRENT / HOLDING CURRENT                        mA
  LED INDICATION                                                       REQUIRED
           POSITION SWITCHES
  TAG NUMBERS - OPEN POSITION / CLOSED POSITION                        220ZSO911A                             220ZSC911A                  0
  MANUFACTURER
  MODEL NUMBER                                                         Contact closed at Limit
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  SWITCH TYPE / FORM
  CONTACT RATING - REQUIRED / ACTUAL                      A
  SWITCHED VOLTAGE                                        V            24 VDC
  CONDUIT ENTRY SIZE (mm) / FLYING LEAD LENGTH (m)   (Refer Note 2)    M20        Refer Note 2
  SWITCH LOCATION - CLOSED, OPEN, BOTH, OTHER                          2 (1 closed, 1 Open)
  No. OF SWITCHES
NOTES:
220UV911A
            GENERAL                                                                                                                                        REV
  TAG NUMBER                                  (Refer Note 1)                220UV911B
  SERVICE                                                                   Sec. Ball Mill 9 Discharge Pump B Discharge Isolation
  EQUIPMENT / LINE NUMBER                                                                                             220-700SL-CS4-209
  LINE DESCRIPTION
  INLET - LINE SIZE / SCHEDULE                                              700                                        STD
  OUTLET - LINE SIZE / SCHEDULE                                             700                                        STD
  FLANGE RATING / FACE                                                      ASME B16.47 150#                           Series A FF
  AREA CLASSIFICATION
  P & ID                                                                    P1664-CS0-2230
  STANDARD INSTRUMENT SPECIFICATION                                         P1664-CS0-E021 Electrical, Instrumentation & Control Guidelines
  STANDARD VALVE SPECIFICATION                                              P1664-CS0-E027 Supply and Installation of Valves and Fittings
  LINE ORIENTATION - HORIZONTAL, VERTICAL, OTHER                            Horizontal
           SYSTEM TESTING
  VENDOR TEST DOCUMENT No. (HYDROSTATIC + FUNCTION TEST)
  NON - DESTRUCTIVE TESTING (Specify Nature, If Any)
  NOTES:
  1. 316SS NAMEPLATE STAMPED WITH VALVE TAG NUMBER & SERVICE IN 10mm CHARACTERS SHALL BE ATTACHED VIA STAINLESS STEEL SCREWS
  OR WIRE.
  2. FACTORY FITTED SOLENOID VALVE AND INTERNAL LIMIT SWITCHES OPERATED BY THE ACTUATOR MECHANISM ARE PREFERRED.
       THESE SHALL BE PRE-WIRED AND TERMINATED IN A JUNCTION BOX MOUNTED ON THE VALVE.
                                                                                                                                     220UV911B
  Issued For Construction             0      8/7/2013     MYR        PP      PP
  REVISION DESCRIPTION               REV      DATE        BY        CHK      APPRV                                DOC No. 220UV911B                  REV     0
           SOLENOID CONSTRUCTION
  COIL VOLTAGE / POWER / FREQUENCY                        V/W/Hz       24 VDC                       2 W Max                   NA          0
  INSULATION CLASS
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  ELECTRICAL CONNECTION / DIN PLUG                   YES/NO            SCREWED TERMINALS                          YES
  COIL TYPE / SINGLE, DOUBLE
  CONDUIT ENTRY SIZE or TYPE                              mm           Refer Note 2
  SURGE SUPPRESSION DIODE                                              REQUIRED
  INRUSH CURRENT / HOLDING CURRENT                        mA
  LED INDICATION                                                       REQUIRED
           POSITION SWITCHES
  TAG NUMBERS - OPEN POSITION / CLOSED POSITION                        220ZSO911B                             220ZSC911B                  0
  MANUFACTURER
  MODEL NUMBER                                                         Contact closed at Limit
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  SWITCH TYPE / FORM
  CONTACT RATING - REQUIRED / ACTUAL                      A
  SWITCHED VOLTAGE                                        V            24 VDC
  CONDUIT ENTRY SIZE (mm) / FLYING LEAD LENGTH (m)   (Refer Note 2)    M20        Refer Note 2
  SWITCH LOCATION - CLOSED, OPEN, BOTH, OTHER                          2 (1 closed, 1 Open)
  No. OF SWITCHES
NOTES:
220UV911B
Instrument Service: Sec. Ball Mill 9 Discharge Pump A Drain Isolation Plant Area: 220- Secondary Grinding
            GENERAL                                                                                                                                           REV
  TAG NUMBER                                  (Refer Note 1)                     220UV912A
  SERVICE                                                                        Sec. Ball Mill 9 Discharge Pump A Drain Isolation
  EQUIPMENT / LINE NUMBER
  LINE DESCRIPTION
  INLET - LINE SIZE / SCHEDULE                                                   300                                         STD                              0
  OUTLET - LINE SIZE / SCHEDULE                                                  300                                         STD                              0
  FLANGE RATING / FACE                                                           ASME B16.5 150#                             FF
  AREA CLASSIFICATION
  P & ID                                                                         P1664-CS0-2230
  STANDARD INSTRUMENT SPECIFICATION                                              P1664-CS0-E021 Electrical, Instrumentation & Control Guidelines
  STANDARD VALVE SPECIFICATION                                                   P1664-CS0-E027 Supply and Installation of Valves and Fittings
  LINE ORIENTATION - HORIZONTAL, VERTICAL, OTHER                                 Vertical
           SYSTEM TESTING
  VENDOR TEST DOCUMENT No. (HYDROSTATIC + FUNCTION TEST)
  NON - DESTRUCTIVE TESTING (Specify Nature, If Any)
  NOTES:
  1. 316SS NAMEPLATE STAMPED WITH VALVE TAG NUMBER & SERVICE IN 10mm CHARACTERS SHALL BE ATTACHED VIA STAINLESS STEEL SCREWS
  OR WIRE.
  2. FACTORY FITTED SOLENOID VALVE AND INTERNAL LIMIT SWITCHES OPERATED BY THE ACTUATOR MECHANISM ARE PREFERRED.
       THESE SHALL BE PRE-WIRED AND TERMINATED IN A JUNCTION BOX MOUNTED ON THE VALVE.
                                                                                                                                        220UV912A
  Issued For Construction             0       8/7/2013     MYR         PP         PP
  REVISION DESCRIPTION               REV       DATE        BY         CHK         APPRV                                 DOC No. 220UV912A               REV       0
           SOLENOID CONSTRUCTION
  COIL VOLTAGE / POWER / FREQUENCY                        V/W/Hz       24 VDC                       2 W Max                   NA          0
  INSULATION CLASS
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  ELECTRICAL CONNECTION / DIN PLUG                   YES/NO            SCREWED TERMINALS                          YES
  COIL TYPE / SINGLE, DOUBLE
  CONDUIT ENTRY SIZE or TYPE                              mm           Refer Note 2
  SURGE SUPPRESSION DIODE                                              REQUIRED
  INRUSH CURRENT / HOLDING CURRENT                        mA
  LED INDICATION                                                       REQUIRED
           POSITION SWITCHES
  TAG NUMBERS - OPEN POSITION / CLOSED POSITION                        220ZSO912A                             220ZSC912A                  0
  MANUFACTURER
  MODEL NUMBER                                                         Contact closed at Limit
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  SWITCH TYPE / FORM
  CONTACT RATING - REQUIRED / ACTUAL                      A
  SWITCHED VOLTAGE                                        V            24 VDC
  CONDUIT ENTRY SIZE (mm) / FLYING LEAD LENGTH (m)   (Refer Note 2)    M20        Refer Note 2
  SWITCH LOCATION - CLOSED, OPEN, BOTH, OTHER                          2 (1 closed, 1 Open)
  No. OF SWITCHES
NOTES:
220UV912A
            GENERAL                                                                                                                                        REV
  TAG NUMBER                                  (Refer Note 1)                  220UV912B
  SERVICE                                                                     Sec. Ball Mill 9 Discharge Pump B Drain Isolation
  EQUIPMENT / LINE NUMBER
  LINE DESCRIPTION
  INLET - LINE SIZE / SCHEDULE                                                300                                         STD                              0
  OUTLET - LINE SIZE / SCHEDULE                                               300                                         STD                              0
  FLANGE RATING / FACE                                                        ASME B16.5 150#                             FF
  AREA CLASSIFICATION
  P & ID                                                                      P1664-CS0-2230
  STANDARD INSTRUMENT SPECIFICATION                                           P1664-CS0-E021 Electrical, Instrumentation & Control Guidelines
  STANDARD VALVE SPECIFICATION                                                P1664-CS0-E027 Supply and Installation of Valves and Fittings
  LINE ORIENTATION - HORIZONTAL, VERTICAL, OTHER                              Vertical
           SYSTEM TESTING
  VENDOR TEST DOCUMENT No. (HYDROSTATIC + FUNCTION TEST)
  NON - DESTRUCTIVE TESTING (Specify Nature, If Any)
  NOTES:
  1. 316SS NAMEPLATE STAMPED WITH VALVE TAG NUMBER & SERVICE IN 10mm CHARACTERS SHALL BE ATTACHED VIA STAINLESS STEEL SCREWS
  OR WIRE.
  2. FACTORY FITTED SOLENOID VALVE AND INTERNAL LIMIT SWITCHES OPERATED BY THE ACTUATOR MECHANISM ARE PREFERRED.
       THESE SHALL BE PRE-WIRED AND TERMINATED IN A JUNCTION BOX MOUNTED ON THE VALVE.
                                                                                                                                     220UV912B
  Issued For Construction             0      8/7/2013     MYR           PP     PP
  REVISION DESCRIPTION               REV      DATE        BY           CHK     APPRV                                 DOC No. 220UV912B               REV       0
           SOLENOID CONSTRUCTION
  COIL VOLTAGE / POWER / FREQUENCY                        V/W/Hz       24 VDC                       2 W Max                   NA          0
  INSULATION CLASS
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  ELECTRICAL CONNECTION / DIN PLUG                   YES/NO            SCREWED TERMINALS                          YES
  COIL TYPE / SINGLE, DOUBLE
  CONDUIT ENTRY SIZE or TYPE                              mm           Refer Note 2
  SURGE SUPPRESSION DIODE                                              REQUIRED
  INRUSH CURRENT / HOLDING CURRENT                        mA
  LED INDICATION                                                       REQUIRED
           POSITION SWITCHES
  TAG NUMBERS - OPEN POSITION / CLOSED POSITION                        220ZSO912B                             220ZSC912B                  0
  MANUFACTURER
  MODEL NUMBER                                                         Contact closed at Limit
  HAZ. AREA APPROVAL / AUTHORISING BODY
  IP RATING - REQUIRED / ACTUAL                                        IP56
  SWITCH TYPE / FORM
  CONTACT RATING - REQUIRED / ACTUAL                      A
  SWITCHED VOLTAGE                                        V            24 VDC
  CONDUIT ENTRY SIZE (mm) / FLYING LEAD LENGTH (m)   (Refer Note 2)    M20        Refer Note 2
  SWITCH LOCATION - CLOSED, OPEN, BOTH, OTHER                          2 (1 closed, 1 Open)
  No. OF SWITCHES
NOTES:
220UV912B