s7300 Product Brief 2003

The SIMATIC S7-300 is the most often sold SIMATIC controller. It provides a universal automation platform which means an optimum solution for your applications in centralized and distributed installations. Permanent innovation makes this automation platform continuously more valuable.

Uploaded by

Surya Darma
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
116 views20 pages

s7300 Product Brief 2003

The SIMATIC S7-300 is the most often sold SIMATIC controller. It provides a universal automation platform which means an optimum solution for your applications in centralized and distributed installations. Permanent innovation makes this automation platform continuously more valuable.

Uploaded by

Surya Darma
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

300_en.fm Seite 1 Donnerstag, 17.

April 2003 1:59 13

For System Solutions with


Emphasis on Production Engineering

Product Brief · March 2003


300_en.fm Seite 2 Donnerstag, 17. April 2003 1:59 13

Introduction

The S7-300 is the most often sold


SIMATIC controller which makes success-
ful automation solutions possible. The
S7-300 for system solutions with its
main emphasis in production engineer-
ing provides a universal automation plat-
form which means an optimum solution
for your applications in centralized and
distributed installations. Permanent in-
novation makes this automation plat-
form continuously more valuable.
Application
The SIMATIC S7-300 offers solutions for
the most diverse automation tasks in
the following areas:
· Production engineering
· Automobile industry
· General machine construction
· Specialized machine construction Production line in the automobile industry – automated with the S7-300
· Machine construction in series (all
kinds of production machines), OEM Low engineering costs Low operating costs
· Processing of plastics The S7-300 is characterized by efficient The Micro Memory Card (MMC) can act
· Packaging industry configuring and programming which as data and program memory so that no
results in low engineering costs. The backup battery is required and mainte-
· Food and tobacco industry huge quantity frameworks of the CPUs nance costs can partly be saved. The
· Process engineering (e.g. water sup- make the S7-300 an ideal platform for MMC can also accommodate a complete
ply, building engineering) the task-oriented STEP 7 Engineering project, including symbols and com-
Special applications Tools complying to IEC 61131-3, for ex- ments, which makes servicing easier
ample high-level languages such as SCL. since no project data are required on the
For special applications there are addi-
In addition, technology-oriented runt- respective device.
tional product designs available based
ime software, e.g. Easy Motion Control The MMC also facilitates program up-
on S7-300:
can be used for motion control tasks. dating. It permits read and write access
· Failsafe applications with a new fail- The Engineering Tools also facilitate during RUN so that, for instance, ar-
safe S7-300F as well as corresponding
modular programming and re-usability chiving of measured values or process-
I/O are now possible.
of existing software. Engineering Tools ing of recipes becomes easy.
· For applications requiring powerful not only support development but also
technological and motion control readibility, ease of maintenance and
functions, a special technology CPU documentation of programs.
can be used.
Additionally, powerful integrated sys-
· At the same time, SIMATIC C7 com- tem diagnostics increase controller
plete units are available based on availability and thus productivity. Con-
S7-300 CPUs with integrated HMI for figurable process diagnostics for analyz-
configuring machine controls where ing process faults, reducing downtimes
space is very restricted. and further enhancing productivity are
· This spectrum is rounded off by a CPU also implemented.
in ET 200S configuring form with
which distributed, intelligent prepro-
cessing is possible.

2
300_en.fm Seite 3 Donnerstag, 17. April 2003 1:59 13

Design and networking

Design
Module
The S7-300 enables a space-saving Central controller (CC) DIN rail
modular configuration to machine con-
trollers adapted to the task at hand,
without taking slot rules into consider-
ation. A fan is not necessary during op- Bus connector
eration. Apart from the modules, only a
DIN rail is required where the modules
are swung into place and secured by PS CPU IM SM SM SM SM SM SM
screws. A configuration is then possible (optional) (optional for expansions)
which is robust and electro-magnetical-
ly compatible.
The backplane bus is integrated into the
module and is assembled by insertion in
the bus connector.
The diverse S7-300 module spectrum
can be used for centralized expansions
as well as for simple configuration of Configuration of the S7-300: space-saving, modular and extremely simple
distributed structures with ET 200M;
this results in a very cost-efficient
spare-parts maintenance.
Powerful, flexible networking
Interfaces that are directly integrated in
the CPUs permit the configuration of a
powerful communication landscape
that employs standard bus technolo-
gies, e.g. for HMI and programming de-
vice functions. Sufficient connectivity is
provided for numerous HMI devices. A
routing function enables a program-
ming device to be connected at any
point in the network and to address all
network nodes.
Multi-point interface - MPI
MPI is the low-cost solution for commu-
nications with programming devices
and PCs, HMI® systems and other
SIMATIC S7/C7/WinAC controllers. A to-
tal of 125 MPI stations can be connect-
ed at transmission rates of 187.5 kbit/s,
e.g. for exchanging process data among
various controllers or for HMI functions
without any programming overhead.
With the CPU 317 and 318-2 DP, the MPI Integrated interfaces of the S7-300 CPUs for direct connection to MPI and PROFIBUS DP
can also be used as PROFIBUS DP inter-
face and permits the configuration of Communications with existing SIMATIC The system is open since it supports the
two DP lines. S5 or SIMATIC 505 systems can also be DP V1 functionality. It facilitates param-
configured. eter assignment and diagnostics for
PROFIBUS DP
Distributed I/Os can be configured with third-party systems connected to a
For the economical configuration of PROFIBUS network.
large distributed networks, the SIMATIC STEP 7 like centralized I/Os which saves a
S7-300 can also be connected to lot of engineering overheads. The For future applications, a new CPU with
PROFIBUS DP (according to EN 50170). S7-300 can be used both as master and integrated Ethernet/PROFInet interface
This opens up communications options slave. for Component based Automation, pro-
with a variety of communications part- gramming and operator control and
ners - from the SIMATIC controller to monitoring via Ethernet will be avail-
third-party field devices. able.

3
300_en.fm Seite 4 Donnerstag, 17. April 2003 1:59 13

CPU spectrum

For setting up a programmable control-


ler system, the user can choose from a
graded spectrum of CPUs, from the
starter model to the high-performance
CPU. The CPUs enable short machine
cycles thanks to their high processing
speed. The narrow module width per-
mits compact controller configurations
and small control cabinet dimensions.
The so-called standard CPUs have a
width of only 40 mm and are also avail-
able in two fail-safe designs. Various
compact CPUs with widths of 80 to 120
mm can additionally integrate I/Os and
technological functions.

CPU 314C-2 DP and CPU 315-2 DP (right)

Design CPU Start of delivery Integrated Integrated Integrated technological Technical


interfaces I/O functions specifica-
tions:
see page
Standard CPUs CPU 312 MPI 6
CPU 314 MPI 6
CPU 315-2 DP DP, MPI 6
CPU 317-2 DP N 3rd quarter 03 DP, DP/MPI 6
CPU 318-2 DP DP, DP/MPI 7
Fail-safe CPUs CPU 315F-2 DP DP, MPI Fail-safety 7
CPU 317F-2 DP N
3rd quarter 03 DP, DP/MPI Fail-safety 7
Compact CPUs CPU 312C MPI Digital Counting 8
CPU 313C MPI Digital, analog Counting 8
CPU 313C-2 PtP PtP, MPI Digital Counting 8
CPU 313C-2 DP DP, MPI Digital Counting 8
CPU 314C-2 PtP PtP, MPI Digital, analog · Counting 9
· Positioning
CPU 314C-2 DP DP, MPI Digital, analog · Counting 9
· Positioning
Technology CPU CPU 317T-2 DP N
4th quarter 03 DP, DP/MPI Digital · Synchronism, 9
· Travel to fixed stop
· Print mark control
· Cam switching
· Controlled positioning

4
300_en.fm Seite 5 Donnerstag, 17. April 2003 1:59 13

CPU Innovation N

All CPUs 317 have 512 KB of working


memory and enable extensive use of
STEP 7 Engineering Tools and techno-
logically oriented runtime software.
They also offer improved and more flex-
ible networking since up to 32 active
links with other nodes, e.g. program-
ming devices and operator panels can
be built up simultaneously.
As many as three versions of high-end
CPUs are available for a variety of appli-
cations:
· The 317-2 DP standard CPU is suitable
for the most common control tasks
with a high share of communications
functions. Both DP interfaces are avail-
able as combined DP/MPI interfaces CPU 317-2 DP - the standard CPU with two CPU 317T-2 DP - the technology CPU for
and can be configured either as PROFI- DP interfaces motion control functions
BUS master or PROFIBUS slave.
· The fail-safe 317F-2 DP CPU offers fail- · The technology CPU 317T-2 DP inte- The six compact CPUs
safety system expansions in compari- grates powerful technology and mo- · CPU 312C
son to the standard CPU and the tion control functions in the CPU. It is
PROFIsafe profile for safe communica- designed for dynamic motion control · CPU 313C
tions. It complies with major specifica- of multiple axes. · CPU 313C-2 PtP
tions/standards: Pre-programmed, PLCopen-compli- · CPU 313C-2 DP
- IEC 61508 (SIL 3), ant motion control functions, integral · CPU 314C-2 PtP
- EN 954 (Category 4) and discrete I/O, equidistance and isoch-
rone mode of PROFIBUS DP permit
· CPU 314C-2 DP
- NFPA 79, NFPA 85 with integral I/O and technological func-
flexible motion control of several
It has an approval from the German (even coupled) axes, for example con- tions have been continuously innovated
Technical Inspectorate (TÜV). trolled positioning, synchronism and provide high functionality and per-
Safety-relevant programs can be pro- and/or cam switching. formance:
grammed using the STEP 7 LAD and STEP 7 enables convenient configura- · Faster actual-value acquisition for the
FBD languages and certified program- tion and parameterization of the axes. counting and frequency measure-
ming examples from the F library of ment functions enables greatly im-
Distributed Safety. proved dynamics, e.g. for positioning
For expansion, the fail-safe ET 200S tasks.
and ET 200M stations are available. Triple processing speed for float-
ing-point operations considerably
speeds up program execution.
· Copy protection of the user software
can be implemented by scanning the
serial number of the MMC during op-
eration.
· An increased number of function calls
and data blocks facilitates porting of
user programs that were originally de-
veloped for “standard” CPUs and are
now to be used as compact CPUs.

5
300_en.fm Seite 6 Donnerstag, 17. April 2003 1:59 13

Standard CPUs

Standard CPUs

Start of delivery
Main memory/
CPU 312

16 Kbyte/5 K
CPU 314

48 Kbyte/16 K
CPU 315-2 DP

128 Kbyte/42 K
CPU 317-2 DP
3rd quarter 2003
512 Kbyte/170 K
N
instructions
Load memory 64 Kbyte to 4 Mbyte 64 Kbyte to 8 Mbyte through MMC
through MMC
Backup all blocks through MMC all blocks to max. 256
Kbyte
Processing times
· Bit operations 0.2 µs 0.1 µs 0.1 µs
· Word operation 0.4 µs 0.2 µs 0.1 µs
· Fixed-point arithmetic 5 µs 2 µs 0.2 µs
· Floating-point 6 µs 6 µs 2 µs
arithmetic
Bit memories/
timers/counters
· Bit memories 128 byte 256 byte 2048 byte 4096 byte
· S7 timers / counters 128/128 256/256 256/256 512/512
· IEC timers / counters yes yes yes yes
Number of blocks
·Number of loadable 1024 1024 2048
blocks (Sum of FCs +
FBs + DBs)
·Range of numbers 512 FC, 512 FB, 511 DB 2048 FC, 2048 FB, 1023 2048 FC, 2048 FB, 2047
DB DB
Organization blocks free cycle (OB 1) free cycle (OB 1)
(OB) real-time interrupt (OB 10) real-time interrupt (OB 10)
delay alarm (OB 20) delay alarm (OB 20)
time-triggered (OB 35) time-triggered (OB 35)
interrupt-triggered (OB 40) interrupt-triggered (OB 40)
restart (OB 100) DPV1 restart (OB 55-57)
asyn. error (OB 80, 82, 85, 87) restart (OB 100)
syn. error (OB 121,122) asyn. error (OB 80. 82, 85-87)
syn. error (OB 121,122)
Address ranges
· I/O address area 1024/1024 byte 1024/1024 byte 2048/2048 byte 8192/8192 byte
· I/O process image 128/128 byte 128/128 byte 128/128 byte 256/256 byte
· Digital channels 256 1024 1024 1024
(central)
· Analog channels 64 256 256 256
(central)
Expansions
· Racks 1 max. 4
· Modules per rack 8 8
DP interfaces
· Number of DP master – – 1/1 2/2
systems int./CP 342-5
· Equidistant – – yes yes
· Activation/deactivation – – yes yes
of slaves
· Transmission speed – – 12 MBit/s 12 MBit/s
· No. of slaves per – – 124 124
station
· Lateral communication – – yes yes
Dimensions (mm) 40 x 125 x 130 40 x 125 x 130 40 x 125 x 130 80 x 125 x 130
Order No. group 6ES7312-1AD.. 6ES7314-1AF.. 6ES7315-2AG.. 6ES7317-2AJ..

6
300_en.fm Seite 7 Donnerstag, 17. April 2003 1:59 13

Standard CPUs  Fail-safe CPUs

Standard CPU Fail-safe CPUs

Start of delivery
Main memory/
CPU 318-2 DP

512 KByte, of which max.


CPU 315F-2 DP

192 Kbyte/36 K F-instructions


CPU 317F-2 DP
3rd quarter 2003 N
512 Kbyte/100 K F-instructions
instructions 256 KByte Code and max.
256 KByte instructions
Load memory – 64 Kbyte to 8 Mbyte through MMC
Backup · 8 Kbyte bit memories, timers, all blocks to max. 256 Kbyte
counters, data without batterie
· all blocks with batterie
Processing times
· Bit operations 0.1 Ns 0.1 Ns 0.1 Ns
· Word operation 0.1 Ns 0.2 Ns 0.1 Ns
· Fixed-point arithmetic 0.1 Ns 2 Ns 0.5 Ns
· Floating-point arithmetic 0.6 Ns 6 Ns 1.5 Ns
Bit memories/
timers/counters
· Bit memories 1024 byte 2048 byte 4096 byte
· S7 timers / counters 512/512 256/256 512/512
· IEC timers / counters yes yes yes
Number of blocks
·Number of loadable blocks 1024 FC, 1024 FB, 2047 DB 1024 2048
(Sum of FCs + FBs + DBs)
·Range of numbers 1024 FC, 1024 FB, 2047 DB 2048 FC, 2048 FB, 1023 DB 2048 FC, 2048 FB, 2047 DB
Organization blocks (OB) real-time interrupt (OB 10, 11) free cycle (OB 1)
delay alarm (OB 20, 21) real-time interrupt (OB 10)
time-triggered (OB 32, 35) delay alarm (OB 20)
interrupt-triggered (OB 40, 41) time-triggered (OB 35)
background OB (OB 90) interrupt-triggered (OB 40)
restart (OB 100), DPVI restart (OB 55-57)
asyn. error (OB 80, 81, 82, 84-87) restart (OB 100)
syn. error (OB 121, 122) asyn. error (OB 80, 82, 85-87)
syn. error (OB 121,122)
Address ranges
· I/O address area 8192/8192 Byte 2048/2048 byte 8192/8192 Byte
· I/O process image 2048/2048 Byte 384/384 byte 1024/1024 Byte
· Digital channels (central) 1024 1024 1024
· Analog channels (central) 256 256 256
Expansions
· Racks max. 4 max. 4
· Modules per rack 8 8
DP interfaces
· Number of DP master systems 2/2 1/1 2/2
int./CP 342-5
· Equidistant yes yes yes
· Activation/deactivation of – yes yes
slaves
· Transmission speed 12 Mbit/s 12 Mbit/s 12 Mbit/s
· No. of slaves per station 32 (MPI-SS), 125 (DP-SS)/ 64 124 124
· Lateral communication yes; sender and receiver yes yes
Dimensions (mm) 160 x 125 x 130 40 x 125 x 130 80 x 125 x 130
Order No. group 6ES7318-2AJ.. 6ES7315-6FF.. 6ES7317-6FF..

7
300_en.fm Seite 8 Donnerstag, 17. April 2003 1:59 13

Compact CPUs

Compact CPUs
CPU 312C CPU 313C CPU 313C-2 PtP CPU 313C-2 DP
Main memory/instruc. 16 Kbyte/4 K 32 Kbyte/10 K 32 Kbyte/10 K 32 Kbyte/10 K
Load memory 64 Kbyte to 4 Mbyte 64 Kbyte to 8 Mbyte through MMC
through MMC
Backup all blocks through MMC
Processing times
· Bit operations 0.2 Ns 0.1 Ns
· Word operations/fixed p. 0.4/5/6 Ns 0.2/2/6 Ns
a./floating-point arithmetic
Bit mem./tim./counters
· Bit memories 128 byte 256 byte
· S7 timers / counters 128/128 256/256
· IEC timers / counters yes yes
Number of blocks
· No. of loadable blocks 1024
· Range of numbers 512 FC, 512 FB, 511 DB
Program processing free cycle (OB 1), real-time controlled (OB 10), delay alarm (OB 20), time-triggered (OB 35), interrupt-triggered
(OB 40), restart (OB 100, 102), asynchronous error (OB 80, 82, 85, 87), synchronous error (OB 121, 122),
station failure/restoration (OB 86, only with CPU 313C-2 DP)
Address ranges
· I/O address range 1024/1024 byte 1024/1024 byte 1024/1024 byte 1024/1024 byte
· I/O process range 128/128 byte 128/128 byte 128/128 byte 128/128 byte
· Digital channels (cent.) 266 1016 1008 1008
· Analog channels (cent.) 64 253 248 248
Expansions
· Racks 1 max. 4
· Modules per rack 8 8
DP interfaces
· No. of DP master systems – 1/1
int./CP 342-5
· Equidistant – yes
· Act./deact. of slaves – yes
· Transmission speed – 12 MBit/s
· No. of DP slaves / station – 32
· Lateral communication – yes
Integrated functions
· Counters 2 incremental encoders 3 incremental encoders 24 V/30 kHz
24 V/10 kHz
· Pulse outputs 2 channel pulse-width 3 channel pulse-width modulation max. 2.5 kHz
modulation max. 2.5 kHz
· Frequency measurement 2 channels max. 10 kHz 3 channels max. 30 kHz
· Controlled positioning – –
· Integ. FBs “loop control” – PID controller
Integrated I/O
· Digital inputs 10; 24 V DC; all channels 24; 24 V DC; all channels 16; 24 V DC; all channels can be used for process
can be used for process can be used for process alarms
alarms alarms
· Digital outputs 6; 24 V DC, 0.5 A 16; 24 V DC, 0.5 A 16; 24 V DC, 0.5 A
· Analog inputs – 4: ± 10 V, 0..10 V, ± 20 mA, –
0/4..20 mA; 1: 0..600 8,
PT100
· Analog outputs – 2: ± 10 V, 0..10 V, ± 20 mA, –
0/4..20 mA
PtP interface
· Physics – RS485/422 –
· Protocol driver – 3964 (R), ASCII –
Dimensions (mm) 80 x 125 x 130 120 x 125 x 130
Req. front connector 1 x 40 pin 2 x 40 pin 1 x 40 pin 1 x 40 pin
Order No. group 6ES7312-5BD.. 6ES7313-5BE.., 6ES7313-6BE.. 6ES7313-6CE..

8
300_en.fm Seite 9 Donnerstag, 17. April 2003 1:59 13

Compact CPUs Technology CPU

N
Compact CPUs Technology CPU
CPU 314C-2 PtP CPU 314C-2 DP CPU 317T-2DP
Start of delivery 4th quarter 2003
Main memory / instructions 48 Kbyte/16 K 48 Kbyte/16 K 512 Kbyte/170 K
Load memory 64 Kbyte to 8 Mbyte through MMC 64 Kbyte to 8 Mbyte through MMC
Backup all blocks through MMC all blocks through MMC
Processing times
· Bit operations 0.1 Ns 0.1 Ns 0.1 Ns
· Word operations/fixed point 0.2/2/6 Ns 0.2/2/6 Ns 0.1/0.2/2 Ns
a./floating point arithmetic
Bit memories/timers/counters
· Bit memories 256 byte 256 byte 4096 byte
· S7 timers / counters 256/256 256/256 512/512
· IEC timers / counters yes yes yes
Number of blocks
· Number of loadable blocks 1024 1024 2048
· Range of numbers 512 FC. 512 FB, 511 DB 512 FC, 512 FB, 511 DB 2048 FC, 2048 FB, 2047 DB
Program processing free cycle (OB 1), real-time controlled (OB 10), delay alarm (OB 20), time-triggered (OB 35), inter-
rupt-triggered (OB 40), restart (OB 100, 102), asynchronous error (OB 80, 82, 85, 87), synchronous error
(OB 121, 122), station failure/restoration (OB 86, not with CPU 314C-2PtP), DPV1 restart (OB 55-57, only
with CPU 317T-2 DP)
Address range
· I/O address range 1024/1024 byte 1024/1024 byte 8192/8192 byte
· I/O process range 128/128 byte 128/128 byte 256/256 byte
· Digital channels (central) 1016 1016 1024
· Analog channels (central) 253 253 256
Expansions
· Racks max. 4 max. 4 1
· Modules per rack 8 8 8
DP interfaces
· No. of DP master systems int./ – 1/1 2/2
CP 342-5
· Equidistant – yes yes
· Act./deact. of slaves – yes yes
· Transmission speed – 12 Mbit/s 12 Mbit/s
· No. of DP slaves / station – 32 124
· Lateral communication – yes yes
Integrated functions · Counters: 4 incremental encoders 24 V/60 kHz · Gear and curve synchronism
· Pulse outputs: 4 channel pulse-width modulation max. 2.5 kHz · Travel to fixed stop
· Frequency measurement: 4 channels max. 60 kHz · Print mark control via measur-
· Controlled positioning: SFB for positioning 1 axis using 2 DA, AA ing probes
· Integrated FBs “loop control”: PID controller · Parth or time-controlled cam
switching
· Controlled positioning
Integrated I/Os
· Digital inputs 24; 24 V DC; all channels can be used for process alarms 4; 24 V DC;
for probe evaluation
· Digital outputs 16; 24 V DC, 0.5 A 8; 24 V DC; 0.6 A; for fast cam
switching functions
· Analog inputs 4: ± 10 V. 0..10 V, ± 20 mA, 0/4..20 mA; 1: 0..600 8,PT100 –

· Analog outputs 2: ±10 V, 0-10 V, ± 20mA, 0/4-20 mA –


PtP interface RS485/422 – –
· Protocol driver 3964 (R), RK512, ASCII – –
Dimensions 120 x 125 x 130 120 x 125 x 130 160 x 125 x 130
Required front connector 2 x 40 pin 1 x 40 pin 1 x 40 pin
Order No. group 6ES7314-6BF.. 6ES7314-6CF.. 6ES7317-6TJ..

9
300_en.fm Seite 10 Donnerstag, 17. April 2003 1:59 13

Fail-Safe with S7-300F

Fail-safe systems are used where the


highest safety standards for personnel,
machines and the environment must be
guaranteed, i.e. accidents and damage
as the result of an error must be avoided
at all costs.
An additional SIMATIC fail-safe control-
ler is now available with the S7-300F es-
pecially for safety-oriented and simulta-
neously distributed applications in the
production industry.
The predominant feature of the
S7-300F is the combination of standard
plant automation and safety engineer-
ing in a single system. This means that
not only “normal” communication but
also safety-oriented communication
(using the PROFIsafe-Profile) with
PROFIBUS DP between central controller
and I/O takes place - intrinsic “normal”
communication is not required. This fu-
sion of standard and safety automation
considerably reduces the expenditure
for configuring and designing modern
safety-oriented plants.
The S7-300F achieves the safety-orient-
ed functions through an F-CPU as well
as a fail-safe modules, which can be
used in the S7-300 as well as in the
ET 200M and ET 200S distributed I/O
systems. A special library is available
from the German Technical Inspector-
ship (TÜV) providing certified program-
Mixed configuration of standard and fail-safe modules, including motor starters
ming examples. The programming
takes place with the standard LAD and
FBD programming languages.
Fail-safe motor starters connected to
ET 200S are available as an ideal supple-
ment to the S7-300F.

10
300_en.fm Seite 11 Donnerstag, 17. April 2003 1:59 13

Programming with STEP 7 and Engineering Tools

The S7-300 is programmed with the ba-


sic software STEP 7 or STEP 7 Lite. This
enables the performance capability of
the S7-300 to be used in a simple,
Programming SIMATIC Manager
user-friendly manner. Both contain Statement list (STL) Programming
functions for all phases of an automa- Ladder diagram (LAD) Statement list (STL)
tion project - from configuring to com- Function block diagram (FBD) Ladder diagram (LAD)
missioning, testing and servicing. Hardware configuration Function block diagram (FBD)
Hardware configuration
STEP 7 Lite Parameterization
The cost-efficient software STEP 7 Lite is Function modules
Communication processors
available to achieve stand-alone appli- Communication
cations with the SIMATIC S7-300. between CPUs
STEP 7 Lite is characterized by very fast
entry into programming and simple Application of Engineering Tools:
project handling. Application of High-level languages
Engineering Tools: Graphic languages
Additional SIMATIC software packages, Simulation Simulation
such as Engineering Tools, cannot be Process diagnostics
used for simulation. Programs which Distributed safety
were generated with STEP 7-Lite, can
also be processed using STEP 7.
STEP 7 STEP 7 and STEP 7 Lite scope of functions
STEP 7 is used for, among other things,
larger or more complex applications, Memory requirements
with which, e.g. programming with
high-level languages or graphic concept
languages (see Engineering Tools)
takes place or the use of function or
communications modules is required.
STEP 7 enables the use of additional SI-
MATIC software packages, for instance
Engineering Tools.
Engineering Tools
Engineering Tools opens additional pos-
sibilities to program automation solu-
tions in a user-friendly, task oriented
manner. The following tools are avail-
able for programming: Productivity
S7-SCL
(Structured Control Language),
the high-level language based on PAS- Memory requirement of engineering tools
CAL for programming SIMATIC S7/C7
controllers
S7-GRAPH Distributed Safety CPUs/Engineering Tools
for graphic configuration of sequential Software package for generating safety- · All CPUs can be programmed in STL,
controls for SIMATIC S7/C7 related programs in LAD and FBD, in- LAD and FBD basic languages.
S7-HiGraph® cluding F library with programming ex- · Should the S7-SCL high-level lan-
for graphic description of sequential or amples guage be used, CPUs 313C, 314 and
asynchronous processes with state The use of Engineering Tools is advanta- above are recommended.
graphs for SIMATIC S7/C7 geous above all for larger, more com-
plex applications and correspondingly · If graphic concept languages
CFC (S7-GRAPH, S7-HiGraph und CFC) are
greater CPUs.
(Continuous Function Chart), the tech- used, CPUs 314 and higher are recom-
nological plan for graphic interconnec- mended.
tion of complex functions for SIMATIC S7

11
300_en.fm Seite 12 Donnerstag, 17. April 2003 1:59 13

Communication  Ethernet, PROFIBUS and more

Totally Integrated Automation


Totally Integrated Automation means:
With a single, completely integrated
and uniform system you can solve all
your automation tasks! Every function is
available from one vendor. PC OS
Distributed preprocessing (distributed
intelligence) makes new concepts in the
plant and machine construction possi-

Data communication
ble with every advantage such as re-us-
ability of the software, faster commis-
sioning times and greater availability. S7-300
Of great significance in the system are OS
communication networks: S7-400
Industrial Ethernet (IEEE 802-3 and
802.3u) –
the international standard for area and
cell networking.
PROFIBUS (IEC 61158/EN 50170) –
the international standard for the cell
and field area as well as PROFIBUS PA for
intrinsic applications in process automa- S7-300 Scanner
tion.
AS-Interface (EN 50295) – Network
the international standard for commu- transition
nication with sensors and actuators.
EIB (EN 50090, ANSI EIA 776) –
the world-wide standardized building
installation system and basis for build-
ing automation.
MPI – Multi point interface –
for communication between CPUs, S7-300
PG/PC and TD/OP.

field communication
Point-to-point coupling – ET 200 Link ET 200
for communication between two nodes
with special protocols. The
point-to-point structure represents
the simplest communication form.
Different special protocols are used
(e.g. RK 512, 3964(R) and ASCII).
Integration in the IT world
Process/

The S7-300 enables the modern IT


world to be integrated into automation Fire detector Sensor
technology.
The following functions are possible
using the insertable CP (CP 343-1 IT):
· Creating your own Web pages with
random HTML tools whereby the pro- The S7-300 can be connected to all kinds of networks
cess variables of the S7-300 are sim-
ply assigned to the HTML objects. · Sending e-mails from the user profile · Remote programming through the
· Monitoring the S7-300 using these of the S7-300 through FC calls. TCP/IP using telephone network as
Web pages with a standard browser. well (e.g. ISDN).

12
300_en.fm Seite 13 Donnerstag, 17. April 2003 1:59 13

Module spectrum

The comprehensive range of modules Product briefs dealing with the mod- Order No. group
enables modular adaptation of the ule spectrum
S7-300 to a wide variety of applications.
Basics of explosion protection 6ZB5310-0LE01-0BA.
The following are available:
Technological tasks with SIMATIC 6ZB5310-0JQ01-0BA.
· Digital and analog I/O modules for al-
most all types of signals, including in- Point-to-point coupler modules 6ZB5310-0KF01-0BA.
terrupt processing and diagnostics AS-Interface E20001-A150-P302
· Digital and analog Ex I/O modules for PROFIBUS 6ZB5530-0AQ01-0BB.
use in hazardous areas
Industrial Ethernet 6ZB5530-0AK01-0BA.
· Function modules for counting/mea-
suring, all sorts of positioning func-
tions, cam control and loop control Communication Technology
· Communication modules for Point-to-point coupling with data transmis- Counting in different operating modes up
point-to-point coupling or bus com- sion rates up to 115 Kbit/s and various pro- to 500 kHz, measuring up to
munication using AS-Interface, tocols, e.g. for connecting printers, 100 kHz and proportioning
PROFIBUS and Industrial Ethernet scanners and third-party devices
with IT functionality Connection to the fieldbus AS-Interface for Cam controls with up to 13 cam tracks per
· Load supply units which provide communicating with binary sensors and
actuators
module
24 V DC operating voltage
· Interface modules for connecting Connection to PROFIBUS using either the
DP or the FMS protocol or by using
All sorts of positioning tasks:
· Controlled positioning in rap-
racks for multi-tier installation of
fiber-optic cable. id-traverse/creep-speed mode
the SIMATIC S7-300 Connection of PROFIBUS PA field devices · Point-to-point positioning and profiles
Expansion options using DP/PA link using stepper and servomotors
Should the automation task require
· Point-to-point multi-axis interpolation
using stepper and servomotors
more than 8 modules, the central con- Connection of positioning drives with
troller (CC) of the S7-300 can be ex- PROFIBUS DP
panded using expansion units (EU)
Connection to Industrial Ethernet using PID controller with backup capability and
(except for CPU 312 IFM, 312C and 313
ISO/TCP or TCP/IP protocol for data commu- integrated, online self configuration for dif-
and 317T-2 DP). Altogether up to 32 nication ferent types of controllers (continuous con-
modules can be used, up to 8 per expan- trollers, stepper controllers, pulse
sion unit. controllers)
Communication between the individual
devices is carried out independently by
interface modules (IM). Expansion with IM 365 Expansion with IM 360/IM 361

In the case of plants covering an exten- Expansion unit (EU) Expansion unit (EU)
sive area, CC/EUs can be configured in
greater distances (up to 10 m).
IM 365 IM 361
This means that for a single-tier installa-
max. 1 m max. 10 m
tion, the maximum configuration is Expansion unit (EU)
Central controller (CC)
256 I/O, with up to 1024 I/O for multiple
line installations. For a distributed sys-
tem using PROFIBUS DP 65536 I/O con- CPU IM 361
nections can be used (up to 125 sta-
max. 10 m
tions, for example ET 200M using Expansion unit (EU)
IM 365
IM 153).
The slots are freely addressable, i.e. no PROFIBUS DP
slot rules exist (except CPU 312 IFM, IM 361
312C, 313, 314, 314 IFM and 317T-2 max. 10 m
DP). Central controller (CC)
IM 153 ET 200M

CPU IM 360

Centralized expansion of the S7-300 to a maximum of 32 modules

13
300_en.fm Seite 14 Donnerstag, 17. April 2003 1:59 13

I/O modules  Special features

Signal modules are the interface of the


SIMATIC S7-300 to the process. A num-
ber of various digital and analog mod-
ules make those I/Os available which are
Universal application Special application
required for the respective task.
Easy installation
Sensors and actuators are connected Digital inputs/outputs
using front connectors. The connector
is simply plugged into the new module
24 V DC 48 to 125 V DC
when the module is replaced, the wiring 120/230 V AC (wide range)
remains unchanged. Coding of the front
connector prevents confusion. 24 V DC active low
Fast connection I/O and relay output for various
Using SIMATIC TOP connect makes it voltages on a module
even easier to connect (not for onboard
I/Os of compact CPUs). You can choose Outputs for different currents
between prewired front connectors
with individual strands and a complete- Processing SSI signals
ly modular building block system, con-
Signal modules for Ex(i) hazardous areas
sisting of front connector module, cable
and terminal block.
Process alarm for rapid response
High packaging density
Diagnostics for rapid error recognition
The large number of channels on each
module is the one reason for the
space-saving design of the S7-300:
Modules are available with 8 to 32
channels (digital) and 2 to 8 channels
(analog).
Analog inputs / outputs
Easy parameterization
Modules are configured and parameter- Measurement of voltage, current, Particularly high resolution,
ized using STEP 7, there are no compli- resistance and temperature very low error tolerance
cated switch settings. Data is stored
centrally and, when modules have been Very fast conversion times for
demanding control functions
replaced, automatically transferred to
the new module to prevent setup er-
(Temperature measurement,
rors. No software upgrading is neces- resistance thermometer)
sary when using new modules. Configu-
rations which have been carried out one
can be repeated identically any number Process alarm for rapid reactions
of times, e.g. for series machines.
Diagnostics, interrupts Diagnostics for particularly fast error recognition
Many modules monitor signal acquisi-
tion (diagnostics) and signals from the
process as well (process alarm). In this
way it is possible to react quickly to any
irregularities or process events. Wheth-
Signal modules for universal and special applications
er the controller should react and what
the reaction should be can be parame-
The dummy module reserves a slot On the following pages you will find cri-
terized in STEP 7.
which has not yet been configured. The teria for selecting the right signal mod-
Special modules mechanical configuration and address ule for a given application.
The simulation module can be inserted allocation remain unchanged when the Detailed technical specifications are
in the S7-300 for testing and simulation module is slotted at a later date. available in the latest version of
purposes. It enables encoder signals to Catalog CA 01
be simulated with the switch and dis- Internet:
plays output signals using LEDs. The www.siemens.com/automation/ca01
module can be plugged in anywhere www.siemens.com/automation/mall
without worrying about slot rules.

14
300_en.fm Seite 15 Donnerstag, 17. April 2003 1:59 13

I/O modules  Selection guide for digital inputs

Module type Selection guide for digital inputs


Voltage DC
Suitable for Switches and 2-/3-/4 wire proximity switches (BEROs)
Input voltage 24 V
Source/sink inputs P
Diagnostics/interrupt yes no
capability
Input delay 0.1 - 20 ms typ. 3 ms (fixed)
(parameteriz-
able)
Number of channels 16 16 32 8 16
Galvanic isolation:
Number of groups 1 1 2 1 1
Extras suitable for iso- – – 8 DO 16 DO
chronous mode
Order No. group 6ES7 321- 6ES7 321- 6ES7 321- 6ES7 323- 6ES7 323-
7BH0.-... 1BH0.-... 1BL0.-... 1BH0.-... 1BL0.-...

Module type Selection guide for digital inputs


Voltage DC UC Universal
voltage
Suitable for Switches and 2-/3-/4 wire proximity NAMUR encoders Switches and 2-/3-/4 wire proximity
switches (BEROs) switches (BEROs)
Input voltage 24 V 48 to 125 V UC 24/48 V
Source/sink inputs M P
Diagnostics/interrupt no yes no
capability
Input delay typ. 3 ms 0.05 ms 3 ms 10 ms < 6 ms
Number of channels 16 16 16 16 16
Galvanic isolation:
Number of groups 1 1 2 8 16
Extras – suitable for iso- includes many – –
chronous mode functions for
control and
instrumentation
technology
Order No. group 6ES7 321- 6ES7 321- 6ES7 321- 6ES7 321- 6ES7 321-
1BH5.-... 1BH10-... 7TH00-... 1CH8.-... 1CH00-...

Module type Selection guide for digital inputs


Voltage AC
Suitable for Switches and 2-/3-/4 wire proximity switches (BEROs)
Input voltage 120/230 V 120 V 120/230 V 120/230 V
Source/sink inputs P P P P
Diagnostics/interrupt capa- no no no no
bility
Input delay < 25 ms < 25 ms < 25 ms < 25 ms
Number of channels 16 32 8 8
Galvanic isolation: 4 4 4 8
Number of groups
Extras – – – –
Order No. group 6ES7 321-1FH0.-... 6ES7 321-1EL0.-... 6ES7 321-1FF0.-... 6ES7 321-1FF1.-...

15
300_en.fm Seite 16 Donnerstag, 17. April 2003 1:59 13

I/O modules  Selection guide for digital outputs

Module type Selection guide for digital outputs


Voltage DC
Suitable for Solenoid valves, DC contactors and indicator lights
Output voltage 24 V
Output current 0.5 A
Diagnostics/interrupt no
capability
Number of channels 16 16 32 8 16
Galvanic isolation:
Number of groups 2 2 4 1 1
Extras – suitable for isoch- – 8 DI 16 DI
ronous mode
Order No. group 6ES7 322- 6ES7 322- 6ES7 322- 6ES7 323- 6ES7 323-
1BH0.-... 1BH10-... 1BL0.-... 1BH0.-... 1BL0.-...

Module type Selection guide for digital outputs


Voltage DC
Suitable for Solenoid valves, DC contactors and indicator lights
Output voltage 24 V 48 to 125 V
Output current 0.5 A 2A 1.5 A
Diagnostics/interrupt yes no
capability
Number of channels 8 16 8 8
Galvanic isolation:
Number of groups 1 4 2 4
Extras – includes many func- – –
tions for control and
instrumentation tech-
nology
Order No. group 6ES7 322-1BF0.-... 6ES7 322- 8BH00-... 6ES7 322-1BF0.-... 6ES7 322-1CF8.-...

Module type Selection guide for digital outputs


Voltage AC UC (Relay)
Suitable for AC magnet coils, contactors, motor starters, AC magnet coils, contactors, motor starters,
small motors and indicator lights small motors and indicator lights
Output voltage 120/230 V 120/230 V 120 V DC: DC 24 to 120 V 24 V/
24 - 120 V AC 48 to 230 V 48 V
AC:
24 - 230 V
Output current 1A 1A 2A 1A 2A 3A 5A 0.5 A
Diagnostics/interrupt capabil- no no yes/no no no yes/no yes
ity
Number of channels 16 8 8 32 16 8 8 8 16
Galvanic isolation:
Number of groups 2 2 8 4 2 4 8 8 16
Extras – – – – – – – – –
Order No. group 6ES7 322-
1FH0.-... 1FF0.-... 5FF0.-... 1EL0.-... 1HH0.-... 1HF0.-... 1HF1.-... 5HF0.-... 65GH00-
...

16
300_en.fm Seite 17 Donnerstag, 17. April 2003 1:59 13

I/O modules  Selection guide for analog inputs

Module type Selection guide for analog inputs


Physical mea- Voltage
sured variable
Encoder mea- ± 80 mV ±5V 0 to 10 V ±1V ± 10 V ±1V
surement range ± 250 mV 1 to 5 V ± 2.5 V ± 50 mV ± 5 mV
± 500 mV ± 10 V ± 10 V ± 500 mV ± 10 mV
±1V 0 to 2 V 1 to 5 V 1 to 5 V
± 2.5 V 0 to 10 V ±1V
±5V
Diagnostics/ yes no yes no yes (at
interrupt 1 ... 5 V)
capability
Operating error ±1% ± 0.1 % ± 0.9 % ± 0.7 % ± 0.15 % ± 0.6 % ± 0.4 %
No. of channels 8 2 8 4 2 4 8 8
No. of groups 4 1 4 1 1 4 1 1
Resolution max. 14 bit + max. 14 bit + 15 bit + sign 8 bit 12 bit + sign 13 bit + sign 12 bit + sign 13 bit + sign
sign sign
Conversion time min. 3 ms min. 3 ms min. 10 ms 5 ms min. 85 ms min. 0.2 ms < 70 ms 52 Ns
per channel
Additional Measure- – Measure- 2 analog Measure- Measure- Measure- Suitable for
functions ment of ment of outputs ment of ment of ment of isochronous
current, current resistance current, current, operation
resistance and temper- 4 analog resistance
and ature (RTD), outputs and temper-
temperature 2 analog ature
(TC + RTD) outputs
Order No. group 6ES7 331- 6ES7 331- 6ES7 331- 6ES7 334- 6ES7 334- 6ES7 335- 6ES7 331- 6ES7 331-
7KF0.-... 7KB0.-... 7NF0.-... 0CE0.-... 0KE0.-... 7HG0.-... 1KF00-... 7HF0.-...

Module type Selection guide for analog inputs


Physical mea- Current
sured variable
Encoder mea- ± 3.2 mA, ± 10 mA, ± 20 mA 0 to 20 mA ± 10 mA 0 to 20 mA ± 20 mA
surement range ± 20 mA, 0 to 20 mA, 0 to 20 mA 0 to 20 mA 0 to 20 mA
4 to 40 mA 4 to 40 mA 4 to 40 mA 4 to 20 mA
Type of 2 and 4 wire transducer 4 wire transducer 2 and 4 wire transducer
connection
Diagnostics/ yes no yes no yes (at
interrupt 4 to 20 mA)
capability
Operating error ±1% ± 0.3 % ± 0.8 % ± 0.25 % ± 0.5 % ± 0.3 %
No. of channels 8 2 8 4 4 8 8
No. of groups 4 1 4 (8) 1 4 1 1
Resolution max. 14 bit + max. 14 bit + 15 bit + sign 8 bit 13 bit + sign 12 bit + sign 13 bit + sign
sign sign
Conversion time min. 3 ms min. 3 ms min. 10 ms 5 ms min. 0.2 ms < 70 ms 52 Ns
per channel
Additional Measurement – Measurement 2 analog Measurement Measurement Suitable for
functions of voltage, of voltage outputs of voltage, of voltage, isochronous
resistance and 4 analog resistance and operation
temperature outputs temperature
(TC + RTD)
Order No. group 6ES7 6ES7 6ES7 6ES7 6ES7 6ES7 6ES7 331-
331-7KF0.-... 331-1BH0.-... 331-7NF0.-... 334-0CE0.-... 335-7HG0.-... 331-1KF00-... 7HF0.-...
(6ES7
331-7NF1.-...)

17
300_en.fm Seite 18 Donnerstag, 17. April 2003 1:59 13

I/O modules  Selection guide for analog inputs

Module type Selection guide for analog inputs


Physical mea- Resistance
sured variable
Encoder mea- 150 8 300 8 600 8 10 k8 600 8, 6 k8
surement range
Type of 2- /3- /4 wire connection
connection
Diagnos- yes no
tics/interrupt
capability
Operating error ±1% ± 0.1 % ± 3.5 % ± 0.5 %
No. of channels 4 1 8 4 8
No. of groups 4 1 4 2 1
Resolution max. 14 bit + sign max. 14 bit + sign max. 15 bit + sign 12 bit + sign 12 bit + sign
Conversion time min. 3 ms min. 3 ms min. 10 ms min. 85 ms < 140 ms
per channel
Additional Measurement of – Measurement of Measurement of Measurement of
functions voltage, current and temperature (RTD) temperature (RTD) current, voltage and
temperature (TC + 2 analog outputs temperature
RTD)
Order No. group 6ES7 331-7KF0.-... 6ES7 331-7KB0.-... 6ES7 331-7PF0.-... 6ES7 334-0KE0.-... 6ES7 331-1KF00-...

Module type Selection guide for analog inputs


Physical mea- Temperature
sured variable
Encoder mea- Pt 100 Pt 100 Pt:100; Thermoelements Thermo Pt 100
surement range (-120 to Ni 100 200; Type E, N, J, K, L elements (-120 to
+130 °C) (-200 to +385 °C) 500; 1000; Type B, E, +130 °C)
Ni:100; N, J, K, L, R,
120; S, T, U
200; 500;
1000;
Cu 10 (-200
to +850 °C
and -120 to
+130 °C)
Diagnostics/ no yes no
interrupt
capability
Operating error ±1% ± 0.1 % ±1% ± 0.1 % ±1%
No. of channels 4 4 1 8 8 2 8 8
No. of groups 2 4 1 4 4 1 4 1
Resolution max. 14 bit max. 14 bit max. 14 bit 15 bit + max. 14 bit max. 14 bit 15 bit + 12 bit +
+ sign + sign + sign sign + sign + sign sign sign
Conversion time min. 85 ms min. 3 ms min. 3 ms min. 10 ms min. 3 ms min. 3 ms min. 10 ms < 140 ms
per channel
Additional Measure- Measure- – Measure- Measure- – – Measure-
functions ment of ment of ment of ment of ment of
resistance, voltage, resistance voltage, voltage,
2 analog current current current
outputs and tem- and tem- and tem-
perature perature perature
(TC) (RTD)
Order No. group 6ES7 334- 6ES7 331- 6ES7 331- 6ES7 331- 6ES7 331- 6ES7 331- 6ES7 331- 6ES7 331-
0KE0.-... 7KF0.-... 7KB0.-... 7PF0.-... 7KF0.-... 7KB0.-... 7PF1.-... 1KF00-...

18
300_en.fm Seite 19 Donnerstag, 17. April 2003 1:59 13

I/O modules  Selection guide for analog outputs

Type of module Selection guide for analog outputs


Physical measured Voltage
variable
Encoder measure- 0 to 10 V, 1 to 5 V, ± 10 V 0 to 10 V 0 to 10 V
ment range 0 to 2 V
Diagnostics capability yes no yes
Operating error ± 0.5 % ± 0.12 % ± 0.6 % ±1% ± 0.5 %
No. of channels 4 2 4 2 2 4
No. of groups 4 2 4 1 1 4
Resolution 12 bit 12 bit max. 15 bit + 8 bit 12 bit + sign 13 bit + sign
sign
Conversion time per 0.8 ms 0.8 ms 1.5 ms 2.5 ms min. 85 ms 0.8 ms
channel
Additional Current output Current output Current out- Current output 4 analog Current out-
functions put, suitable 4 analog inputs put, 4 analog
for isochronous inputs inputs
operation
Order No. group 6ES7 332- 6ES7 332- 6ES7 332- 6ES7 334- 6ES7 334- 6ES7 335-
5HD0.-... 5BH0.-... 7ND0.-... 0CE0.-... 0KE0.-... 7HG0.-...

Type of module Selection guide for analog outputs


Physical measured Current
variable
Encoder measure- ± 20 mA, 0 to 20 mA, 4 to 20 mA 0 to 20 mA
ment range
Type of 2 wire connection
connection
Diagnostics capability yes no
Operating error ± 0.6 % ± 0.18 % ± 1.0 %
No. of channels 4 2 4 2
No. of groups 4 2 4 1
Resolution 12 bit 12 bit max. 15 bit + sign 12 bit
Conversion time per 0.8 ms 0.8 ms 1.5 ms 0.8 ms
channel
Additional Voltage output Voltage output Voltage output Voltage output,
functions 4 analog inputs
Order No. group 6ES7 332-5HD0.-... 6ES7 332-5HB0.-... 6ES7 332-7ND0.-... 6ES7 334-0CE0.-...

19
300_en.fm Seite 20 Donnerstag, 17. April 2003 1:59 13

Standards

The SIMATIC S7-300 fulfills the follow- The fail-safe CPUs fulfil the following
ing national and international stan- standards
dards:
· DIN, EN, IEC · IEC 61508 (SIL 3)
· UL certificate · EN 954 (Cat. 4)
· CSA certificate · NFPA 79, NFPA 85
· FM class 1 div. 2; groups A, B, C and D
· Temperature group T4 (b 135 °C)
· Marine approvals from:
· American Bureau of Shipping
· Bureau Veritas
· Des Norske Veritas
· Germanischer Lloyd
· Lloyds Register of Shipping
· Ambient temperature 0 to 60 °C for all
components
· Earthquake-proof
· EU regulation 94/9/EG (ATEX 100a)

marked with a ® are registered trade-


All designations in this Product Brief

Further information regarding SIMATIC To get in touch with your contact per- With the A&D Mall you can order elec-
controllers can be found in the Internet: son near you, look in the Internet under: tronically using the Internet:
marks of the Siemens AG.

www.siemens.com/simatic-controller www.siemens.com/automation/partner www.siemens.com/automation/mall

www.siemens.com/simatic-controller © Siemens AG 2003


Siemens AG
Order No.: 6ZB5310-0HW02-0BA7 Subject to change without prior notice.
Automation and Drives
Printed in the Federal Republic of Germany
Postfach 4848, D-90327 Nürnberg 26100/301425 MAN 04035.