2.
WIRING
2.4 Junction Box IC-315
Use the junction box IC-315 to connect the distress alert/received call unit
IC-305 and other unit (max. four units) to the terminal unit.
Unfasten four screws to remove the box cover to connect cables.
For connection, use the optional 5 pair cable CO-SPEVV-SB-C 0.2x5P, JIS cable
(Japan Industrial Standards) TTYCS-4 or equivalent. When using the
CO-SPEVV-SB-C 0.2x5P cable, replace the cable clamp with the cable clamp
16-018-6008-1, supplied with IC-315.
1 Vcc
IC-305/306
2 GND
3 TD/RD-A
4 TD/RD-B
Cover 5 NC
6 TD-A(NAV) 1
7 TD-B(NAV) 2
8 RD-A(NAV)
9 RD-B(NAV)
10 GND
11 DMC OUT-H
Cable clamp 12 DMC OUT-C
13 DMC IN-H
14 DMC IN-C 3 Core 7 mm
15 DMC CTR
Terminal
board Sticker for
To terminal unit
connection of
other equipment
Procedure
1. Insert driver from direction 1 .
2. Tilt slightly toward 2 .
3. Insert cable core to 3 .
4. Pull out the driver.
Note 1: Do not insert the cable deeply
to prevent pinching the cable sheath.
Note 2: Pull the cable slightly to confirm
the tightening
Junction Box IC-315
Input/output sentences
The following sentences can be input/output with the navigator connected.
Input sentences Output sentences
GGA, GLL, VTG, WPL, RMA, RMB,
RMC, MTW, DBT, BWC, BWR, VDR, GGA, ZDA, GLL, VTG, RMC, GSV
ZDA
17