0% found this document useful (0 votes)
49 views56 pages

Project 0: Date: 21/10/2019

The document is a table of contents for a project report on lighting design for Site 1, Building 1, Storey 1 of a project. It lists various rooms in the storey and for each includes a room summary, luminaire layout plan, and workplane illuminance results. Specific rooms listed include the balcony, bath, bedroom, corridor, kitchen, and others. For each room, lighting performance targets and metrics like average illuminance and minimum to maximum ratios are provided.

Uploaded by

Maged Beshay
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
49 views56 pages

Project 0: Date: 21/10/2019

The document is a table of contents for a project report on lighting design for Site 1, Building 1, Storey 1 of a project. It lists various rooms in the storey and for each includes a room summary, luminaire layout plan, and workplane illuminance results. Specific rooms listed include the balcony, bath, bedroom, corridor, kitchen, and others. For each room, lighting performance targets and metrics like average illuminance and minimum to maximum ratios are provided.

Uploaded by

Maged Beshay
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 56

Date:

21/10/2019

Project 0
Project 0 21/10/2019

Project 0 / Table of contents

Table of contents
Project 0
Site 1
Building 1
Storey 1
balcony
Room summary....................................................................................................................................................................................... 3
Luminaire layout plan.............................................................................................................................................................................. 4
Workplane (balcony) / Perpendicular illuminance (adaptive).................................................................................................................. 5
bath
Room summary....................................................................................................................................................................................... 6
Luminaire layout plan.............................................................................................................................................................................. 7
Workplane (bath) / Perpendicular illuminance (adaptive)........................................................................................................................8
bed room
Room summary..................................................................................................................................................................................... 11
Luminaire layout plan............................................................................................................................................................................ 12
Workplane (bed room) / Perpendicular illuminance (adaptive)............................................................................................................. 13
Bed room
Room summary..................................................................................................................................................................................... 17
Luminaire layout plan............................................................................................................................................................................ 18
Workplane (Bed room) / Perpendicular illuminance (adaptive)............................................................................................................. 19
corridor
Room summary..................................................................................................................................................................................... 23
Luminaire layout plan............................................................................................................................................................................ 24
Workplane (corridor) / Perpendicular illuminance (adaptive)................................................................................................................ 25
kitchen
Room summary..................................................................................................................................................................................... 29
Luminaire layout plan............................................................................................................................................................................ 30
Workplane (kitchen) / Perpendicular illuminance (adaptive)................................................................................................................. 31
master bath
Room summary..................................................................................................................................................................................... 35
Workplane (master bath) / Perpendicular illuminance (adaptive)..........................................................................................................36
Master bed room
Room summary..................................................................................................................................................................................... 39
Workplane (Master bed room) / Perpendicular illuminance (adaptive)................................................................................................. 40
salon
Room summary..................................................................................................................................................................................... 44
Workplane (salon) / Perpendicular illuminance (adaptive).................................................................................................................... 45
shower
Room summary..................................................................................................................................................................................... 49
Workplane (shower) / Perpendicular illuminance (adaptive)................................................................................................................. 50
toilet
Room summary..................................................................................................................................................................................... 54
Workplane (toilet) / Perpendicular illuminance (adaptive)..................................................................................................................... 55

Page 2
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / balcony / Room summary

balcony

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (balcony) Perpendicular illuminance (adaptive) [lx] * 100 (≥ 100) 62.9 122 0.63 0.52
Height: 0.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

2 Philips - SM150C L602 1xLED24S/830 2400 20.0 120.0

Total via all luminaires 4800 40.0 120.0

Lighting power density: 5.17 W/m² = 5.15 W/m²/100 lx (Floor area of room 7.74 m²)

Consumption: 77 kWh/a of maximum 300 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 3
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / balcony / Luminaire layout plan

balcony

Philips SM150C L602 1xLED24S/830

No. X [m] Y [m] Mounting height [m] Maintenance factor


1 5.699 0.525 2.800 0.70
2 1.900 0.525 2.800 0.70

Page 4
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / balcony / Workplane (balcony) / Perpendicular illuminance (adaptive)

Workplane (balcony) / Perpendicular illuminance (adaptive)

Workplane (balcony): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 100 lx (Target: ≥ 100 lx), Min: 62.9 lx, Max: 122 lx, Min/average: 0.63, Min/max: 0.52
Height: 0.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Isolines [lx]

Scale: 1 : 50

False colours [lx]

Scale: 1 : 50

Value grid [lx]

Scale: 1 : 50

Page 5
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bath / Room summary

bath

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (bath) Perpendicular illuminance (adaptive) [lx] * 273 (≥ 300) 222 311 0.81 0.71
Height: 0.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

2 Philips - SM534C PSD L1130 1 xLED40S/830 PSD A 3999 36.5 109.6

Total via all luminaires 7998 73.0 109.6

Lighting power density: 13.72 W/m² = 5.02 W/m²/100 lx (Floor area of room 5.32 m²)

Consumption: 140 kWh/a of maximum 200 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 6
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bath / Luminaire layout plan

bath

Philips SM534C PSD L1130 1 xLED40S/830 PSD A

No. X [m] Y [m] Mounting height [m] Maintenance factor


1 1.757 1.183 2.800 0.70
2 0.491 1.183 2.800 0.70

Page 7
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bath / Workplane (bath) / Perpendicular illuminance (adaptive)

Workplane (bath) / Perpendicular illuminance (adaptive)

Workplane (bath): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 273 lx (Target: ≥ 300 lx), Min: 222 lx, Max: 311 lx, Min/average: 0.81, Min/max: 0.71
Height: 0.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Page 8
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bath / Workplane (bath) / Perpendicular illuminance (adaptive)

Isolines [lx]

Scale: 1 : 25

False colours [lx]

Scale: 1 : 25

Page 9
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bath / Workplane (bath) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 25

Page 10
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bed room / Room summary

bed room

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (bed room) Perpendicular illuminance (adaptive) [lx] * 184 (≥ 200) 125 221 0.68 0.57
Height: 0.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

4 Philips - SM150C L602 1xLED24S/830 2400 20.0 120.0

Total via all luminaires 9600 80.0 120.0

Lighting power density: 4.29 W/m² = 2.33 W/m²/100 lx (Floor area of room 18.66 m²)

Consumption: 66 kWh/a of maximum 700 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 11
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bed room / Luminaire layout plan

bed room

Philips SM150C L602 1xLED24S/830

No. X [m] Y [m] Mounting height [m] Maintenance factor


1 1.000 3.499 2.800 0.70
2 1.000 1.166 2.800 0.70
3 3.000 3.499 2.800 0.70
4 3.000 1.166 2.800 0.70

Page 12
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bed room / Workplane (bed room) / Perpendicular illuminance (adaptive)

Workplane (bed room) / Perpendicular illuminance (adaptive)

Workplane (bed room): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 184 lx (Target: ≥ 200 lx), Min: 125 lx, Max: 221 lx, Min/average: 0.68, Min/max: 0.57
Height: 0.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Page 13
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bed room / Workplane (bed room) / Perpendicular illuminance (adaptive)

Isolines [lx]

Scale: 1 : 25

Page 14
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bed room / Workplane (bed room) / Perpendicular illuminance (adaptive)

False colours [lx]

Scale: 1 : 25

Page 15
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bed room / Workplane (bed room) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 25

Page 16
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / Bed room / Room summary

Bed room

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (Bed room) Perpendicular illuminance (adaptive) [lx] * 264 (≥ 300) 136 461 0.52 0.30
Height: 0.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

3 Philips - SM534C PSD L1130 1 xLED40S/830 PSD A 3999 36.5 109.6

Total via all luminaires 11997 109.5 109.6

Lighting power density: 6.68 W/m² = 2.53 W/m²/100 lx (Floor area of room 16.39 m²)

Consumption: 430 kWh/a of maximum 600 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 17
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / Bed room / Luminaire layout plan

Bed room

Philips SM534C PSD L1130 1 xLED40S/830 PSD A

No. X [m] Y [m] Mounting height [m] Maintenance factor


1 1.739 0.730 2.800 0.70
2 1.739 2.190 2.800 0.70
3 1.739 3.650 2.800 0.70

Page 18
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / Bed room / Workplane (Bed room) / Perpendicular illuminance (adaptive)

Workplane (Bed room) / Perpendicular illuminance (adaptive)

Workplane (Bed room): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 264 lx (Target: ≥ 300 lx), Min: 136 lx, Max: 461 lx, Min/average: 0.52, Min/max: 0.30
Height: 0.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Page 19
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / Bed room / Workplane (Bed room) / Perpendicular illuminance (adaptive)

Isolines [lx]

Scale: 1 : 25

Page 20
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / Bed room / Workplane (Bed room) / Perpendicular illuminance (adaptive)

False colours [lx]

Scale: 1 : 25

Page 21
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / Bed room / Workplane (Bed room) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 25

Page 22
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / corridor / Room summary

corridor

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (corridor) Perpendicular illuminance (adaptive) [lx] * 127 (≥ 100) 25.5 187 0.20 0.14
Height: 0.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

4 Philips - SM150C L602 1xLED24S/830 2400 20.0 120.0

Total via all luminaires 9600 80.0 120.0

Lighting power density: 4.37 W/m² = 3.45 W/m²/100 lx (Floor area of room 18.31 m²)

Consumption: 88 kWh/a of maximum 650 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 23
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / corridor / Luminaire layout plan

corridor

Philips SM150C L602 1xLED24S/830

No. X [m] Y [m] Mounting height [m] Maintenance factor


1 5.434 5.502 2.800 0.70
2 2.417 5.471 2.800 0.70
3 0.923 4.511 2.800 0.70
4 0.954 1.495 2.800 0.70

Page 24
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / corridor / Workplane (corridor) / Perpendicular illuminance (adaptive)

Workplane (corridor) / Perpendicular illuminance (adaptive)

Workplane (corridor): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 127 lx (Target: ≥ 100 lx), Min: 25.5 lx, Max: 187 lx, Min/average: 0.20, Min/max: 0.14
Height: 0.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Page 25
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / corridor / Workplane (corridor) / Perpendicular illuminance (adaptive)

Isolines [lx]

Scale: 1 : 50

Page 26
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / corridor / Workplane (corridor) / Perpendicular illuminance (adaptive)

False colours [lx]

Scale: 1 : 50

Page 27
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / corridor / Workplane (corridor) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 50

Page 28
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / kitchen / Room summary

kitchen

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (kitchen) Perpendicular illuminance (adaptive) [lx] * 501 (≥ 500) 225 982 0.45 0.23
Height: 1.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

3 Philips - SM534C PSD L1130 1 xLED40S/830 PSD A 3999 36.5 109.6

Total via all luminaires 11997 109.5 109.6

Lighting power density: 11.01 W/m² = 2.20 W/m²/100 lx (Floor area of room 9.95 m²)

Consumption: 670 kWh/a of maximum 350 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 29
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / kitchen / Luminaire layout plan

kitchen

Philips SM534C PSD L1130 1 xLED40S/830 PSD A

No. X [m] Y [m] Mounting height [m] Maintenance factor


1 1.601 2.621 2.800 0.70
2 1.601 1.554 2.800 0.70
3 1.601 0.487 2.800 0.70

Page 30
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / kitchen / Workplane (kitchen) / Perpendicular illuminance (adaptive)

Workplane (kitchen) / Perpendicular illuminance (adaptive)

Workplane (kitchen): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 501 lx (Target: ≥ 500 lx), Min: 225 lx, Max: 982 lx, Min/average: 0.45, Min/max: 0.23
Height: 1.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Page 31
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / kitchen / Workplane (kitchen) / Perpendicular illuminance (adaptive)

Isolines [lx]

Scale: 1 : 25

Page 32
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / kitchen / Workplane (kitchen) / Perpendicular illuminance (adaptive)

False colours [lx]

Scale: 1 : 25

Page 33
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / kitchen / Workplane (kitchen) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 25

Page 34
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / master bath / Room summary

master bath

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (master bath) Perpendicular illuminance (adaptive) [lx] * 389 (≥ 300) 197 478 0.51 0.41
Height: 0.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

2 Philips - SM534C PSD L1130 1 xLED40S/830 PSD A 3999 36.5 109.6

Total via all luminaires 7998 73.0 109.6

Lighting power density: 12.04 W/m² = 3.10 W/m²/100 lx (Floor area of room 6.06 m²)

Consumption: 140 kWh/a of maximum 250 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 35
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / master bath / Workplane (master bath) / Perpendicular illuminance (adaptive)

Workplane (master bath) / Perpendicular illuminance (adaptive)

Workplane (master bath): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 389 lx (Target: ≥ 300 lx), Min: 197 lx, Max: 478 lx, Min/average: 0.51, Min/max: 0.41
Height: 0.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Page 36
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / master bath / Workplane (master bath) / Perpendicular illuminance (adaptive)

Isolines [lx]

Scale: 1 : 25

False colours [lx]

Scale: 1 : 25

Page 37
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / master bath / Workplane (master bath) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 25

Page 38
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / Master bed room / Room summary

Master bed room

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (Master bed room) Perpendicular illuminance (adaptive) [lx] * 184 (≥ 200) 98.6 250 0.54 0.39
Height: 0.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

5 Philips - SM150C L602 1xLED24S/830 2400 20.0 120.0

Total via all luminaires 12000 100.0 120.0

Lighting power density: 3.97 W/m² = 2.16 W/m²/100 lx (Floor area of room 25.19 m²)

Consumption: 390 kWh/a of maximum 900 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 39
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / Master bed room / Workplane (Master bed room) / Perpendicular illuminance (adaptive)

Workplane (Master bed room) / Perpendicular illuminance (adaptive)

Workplane (Master bed room): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 184 lx (Target: ≥ 200 lx), Min: 98.6 lx, Max: 250 lx, Min/average: 0.54, Min/max: 0.39
Height: 0.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Page 40
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / Master bed room / Workplane (Master bed room) / Perpendicular illuminance (adaptive)

Isolines [lx]

Scale: 1 : 50

Page 41
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / Master bed room / Workplane (Master bed room) / Perpendicular illuminance (adaptive)

False colours [lx]

Scale: 1 : 50

Page 42
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / Master bed room / Workplane (Master bed room) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 50

Page 43
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / salon / Room summary

salon

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (salon) Perpendicular illuminance (adaptive) [lx] * 207 (≥ 200) 76.5 286 0.37 0.27
Height: 0.800 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

7 Philips - SM150C L602 1xLED24S/830 2400 20.0 120.0

Total via all luminaires 16800 140.0 120.0

Lighting power density: 3.27 W/m² = 1.58 W/m²/100 lx (Floor area of room 42.78 m²)

Consumption: 550 kWh/a of maximum 1500 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 44
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / salon / Workplane (salon) / Perpendicular illuminance (adaptive)

Workplane (salon) / Perpendicular illuminance (adaptive)

Workplane (salon): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 207 lx (Target: ≥ 200 lx), Min: 76.5 lx, Max: 286 lx, Min/average: 0.37, Min/max: 0.27
Height: 0.800 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Page 45
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / salon / Workplane (salon) / Perpendicular illuminance (adaptive)

Isolines [lx]

Scale: 1 : 50

Page 46
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / salon / Workplane (salon) / Perpendicular illuminance (adaptive)

False colours [lx]

Scale: 1 : 50

Page 47
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / salon / Workplane (salon) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 50

Page 48
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / shower / Room summary

shower

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (shower) Perpendicular illuminance (adaptive) [lx] * 219 (≥ 300) 203 235 0.93 0.86
Height: 0.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

2 Philips - SM150C L602 1xLED24S/830 2400 20.0 120.0

Total via all luminaires 4800 40.0 120.0

Lighting power density: 20.76 W/m² = 9.48 W/m²/100 lx (Floor area of room 1.93 m²)

Consumption: 77 kWh/a of maximum 100 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 49
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / shower / Workplane (shower) / Perpendicular illuminance (adaptive)

Workplane (shower) / Perpendicular illuminance (adaptive)

Workplane (shower): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 219 lx (Target: ≥ 300 lx), Min: 203 lx, Max: 235 lx, Min/average: 0.93, Min/max: 0.86
Height: 0.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Page 50
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / shower / Workplane (shower) / Perpendicular illuminance (adaptive)

Isolines [lx]

Scale: 1 : 10

Page 51
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / shower / Workplane (shower) / Perpendicular illuminance (adaptive)

False colours [lx]

Scale: 1 : 10

Page 52
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / shower / Workplane (shower) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 10

Page 53
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / toilet / Room summary

toilet

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (toilet) Perpendicular illuminance (adaptive) [lx] * 216 (≥ 300) 149 256 0.69 0.58
Height: 0.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

1 Philips - SM534C PSD L1130 1 xLED40S/830 PSD A 3999 36.5 109.6

Total via all luminaires 3999 36.5 109.6

Lighting power density: 13.54 W/m² = 6.26 W/m²/100 lx (Floor area of room 2.70 m²)

Consumption: 70 kWh/a of maximum 100 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 54
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / toilet / Workplane (toilet) / Perpendicular illuminance (adaptive)

Workplane (toilet) / Perpendicular illuminance (adaptive)

Workplane (toilet): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 216 lx (Target: ≥ 300 lx), Min: 149 lx, Max: 256 lx, Min/average: 0.69, Min/max: 0.58
Height: 0.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Isolines [lx]

Scale: 1 : 25

False colours [lx]

Scale: 1 : 25

Page 55
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / toilet / Workplane (toilet) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 25

Page 56