3 D LCD Digital Panel Meter Model: LC035: 1. Features

The document provides instructions for operating a 3.5 digit LCD digital panel meter. It details features such as input sensitivity, operation voltage, decimal point selection, and automatic polarity indication. Specifications covered include maximum input, display, accuracy, power dissipation and supply voltage. Setup and connection instructions are provided.

Uploaded by

Nouh Nahnouh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
158 views2 pages

3 D LCD Digital Panel Meter Model: LC035: 1. Features

The document provides instructions for operating a 3.5 digit LCD digital panel meter. It details features such as input sensitivity, operation voltage, decimal point selection, and automatic polarity indication. Specifications covered include maximum input, display, accuracy, power dissipation and supply voltage. Setup and connection instructions are provided.

Uploaded by

Nouh Nahnouh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

®

d) Connect the input voltage to be measured to


V in and GND. The input voltage should be
DC only.
3½D LCD Digital Panel Meter
1. FEATURES :
Model : LC035 l 200mV full scale input sensitivity l Single

9V DC operation l Decimal point selectable


l 13mm figure height l Automatic Polarity

indication l Guaranteed zero reading for 0 volt


input l High input impedance ( > 10 MV )
l Easy Bezel fixing Method

2. APPLICATIONS :
User Manual l Voltmeter l Thermometer l PH Meter
l DB Meter l Watt Meter l Current Meter
l Capacitance Meter l Lux Meter l LCR
4. OPERATION :
a) If needed, add proper voltage dividers (not Meter l Other industrial & domestic uses.
included) and decimal point wire jumper. 3. SPECIFICATIONS :
: 199.9mV DC
Maximum Input
Max. Voltage Proper Voltage Decimal Point : 1999 (3½ Digit) with
Maximum Display
to be measured Divider fixing method automatic polarity
200mV - Shortcircuit P1 on indication
& P2, P3 off Indication Method : LCD Display

2V Disconnect wire Shortcircuit P3 on Measuring Method : Dual-Slope Integration


A-D converter system
jumper in RB & P1, P2 off
RA = 1.1KV,
:
Overrange indication " 1 " shown in the display.
Reading rate time : 2-3 reading per second.
RB = 10MV
Input Impedance : > 10MV
20V Disconnect wire Shortcircuit P2 on : ± 0.5% of full scale
Accuracy
jumper in RB & P1, P3 off (230±50C < 80%RH)
RA = 100KV, : 1mA DC
Power Dissipation
RB = 9.9MV : Selectable with wire jumper
Decimal Points
200V Disconnect wire Shortcircuit P2 on Supply Voltage : 7-11V DC
jumper in RB & P1, P3 off Size : 68mm x 44mm
RA = 10KV,
RB = 9.99MV
500V Disconnect wire
jumper in RB
RA = 1KV,
RB = 9.999MV

Shortcircuit N on to enable polarity sign function


or shortcircuit N off to disable polarity sign function
RA and RB are ½ W 0.5% Metal film resistors.
b) Connect 7-11V DC power supply to panel
meter. Pay attention to the proper polarity.
Test Result : S.No. .............................................
c) For range other than 200mV, input accurately
½ x Max. Voltage generated by calibrator Input
( e.g. 100.0V for 200.0V range) and carefully ...............
adjust the semi-fixed resistor R4 to have Result OK OK OK OK OK
same reading in L.C.D.
Checked by : ..................... Date : .....................
www.mecoinst.com

LC035 : 28-09-2012
®
1. FEATURES :
l 200mV full scale input sensitivity l Single

5V DC operation l Decimal point selectable


3½D LED Digital Panel Meter l 14.2mm figure height l Automatic Polarity
Model : LC135 indication l Guaranteed zero reading for 0 volt
input l High input impedance ( > 10 MV )
l Easy Bezel fixing Method

2. SPECIFICATIONS :
Maximum Input : 199.9mV DC
Maximum Display : 1999 (3½ Digit) with
automatic polarity
User Manual indication
b) Connect 5DC power supply to panel meter. Indication Method : LED Display
Pay attention to the proper polarity. Measuring Method : Dual-Slope A-D
conversion
c) For range other than 200mV, input accurately
Overrange indication : " 1 " or " -1 " shown in
½ x Max. Voltage to be measured, ( e. g.
the display.
100.0V for 200.0V range by calibrator ) and
Reading rate time : 2-3 reading per second.
carefully adjust the pot R2 to have some
Input Impedance : > 10MV
reading in LED display.
Accuracy : ± 0.5% of full scale
d) Connect the input voltage to be measured to (230±50C < 80%RH)
V in (+) and V in (-). The input voltage should Power Dissipation : <1W
be DC only. Decimal Points : Selectable with wire
jumper
Supply Voltage : 5V DC
INPUT Size : 68mm x 44mm
SIGNAL
3. OPERATION :
a) If needed, add proper voltage dividers
POWER
(not included)
SUPPLY
5V DC
Max. Voltage Proper Voltage
to be measured Divider
S
Shorting S will display the 200mV -
corresponding decimal point
2V Disconnect wire jumper in RA
RA = 1.1MV, RB = 9.9MV

20V Disconnect wire jumper in RA


Test Result : S.No. ............................................. RA = 100KV, RB = 9.99MV
Input 200V Disconnect wire jumper in RA
............... RA = 10KV, RB = 9.99MV
Result OK OK OK OK OK
500V Disconnect wire jumper in RA
Checked by : ..................... Date : ..................... RA = 1KV, RB = 9.999MV
Note :
Please ensure that when shunt is use, it must RA and RB are ½W 0.5% Metal Film Resistors.
be connected on the ground / common side of
the load and not on the supply side.
www.mecoinst.com

LC135 : 28-09-2012