GROUP 12 PROLIX SWITCH (up to # 0062)
Is the conversion switch to manual control temporarily when the electronic control system is out of
 order, until repair work be done.
                                                                                        EMERGENCY
                                       Electric box
                                                                                            NORMAL
                                                               Never place this switch in EMERGENCY
                                                               position when the CPU is in normal operation.
1. OPERATING PRINCIPLE WIRING DIAGRAM
                      CN-75                                                                          Normal    :
                            2
                            1
                    EPPR V/V                                               CN-47                     Emergency :
                                                                           2
                                                                           1
                                                                          RESISTOR
                                                                           CS-7
                                                                            6   6
                                                                                    4   5
                                                                                            5
                                                                            5   4
                                                                                    6
                                                                            4
                                                                                    1
                                                                            3   3       2
                                                                                            2
                                                                            2   1
                                                                                    3
                                                                                    T
                                                                            1
                                                                          PROLIX SW
            CN-51
                                     CN-50
                       32                    8   24 28    36
                                CPU CONTROLLER
 1) NORMAL POSITION
    ・EPPR valve supply specified amount of pilot pressure to the flow regulator of hydraulic pump and
     regulate hydraulic pump delivery amount depending upon the signal of CPU controller by selected
     mode.
 2) EMERGENCY POSITION
    ・If prolix switch is set at the emergency position when any abnormality occurs in NEW CAPO
      system, constant electric current from battery flows to EPPR valve so that EPPR valve can be
      fixed at the predetermined position.
    ・In this case excavator can be operated at an equivalent performance to S mode.
                                                         5 - 25