Single-Phase Inverters for Installers

The document describes Kaco blueplanet 3.0-5.0 TL1 series single-phase string inverters. The inverters have transformerless design, up to two maximum power point trackers, wide input voltage range, data logging and web server access, lightweight and compact design, plug-in AC and DC connectors, graphical display and intuitive menu navigation. Technical specifications include power ratings up to 6 kW, DC input voltage range of 125-550V, 97.2% maximum efficiency, IP54 protection, and compliance with relevant IEC and EN safety standards.

Uploaded by

Thắng Còi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
77 views4 pages

Single-Phase Inverters for Installers

The document describes Kaco blueplanet 3.0-5.0 TL1 series single-phase string inverters. The inverters have transformerless design, up to two maximum power point trackers, wide input voltage range, data logging and web server access, lightweight and compact design, plug-in AC and DC connectors, graphical display and intuitive menu navigation. Technical specifications include power ratings up to 6 kW, DC input voltage range of 125-550V, 97.2% maximum efficiency, IP54 protection, and compliance with relevant IEC and EN safety standards.

Uploaded by

Thắng Còi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

blueplanet 3.0 – 5.

0 TL1
Transformerless, single-phase string inverters.

Small system? Big convenience. Highest yields!

2 MPP trackers, wide MPP range Data logger with web server Lightweight

Convenient AC and DC cabling Graphical display, intuitive menu Straightforward monitoring


thanks to plug-in connectors navigation

www.kaco-newenergy.com
Technical Data
DC input data 3.0 TL1 M1 3.0 TL1 3.5 TL1
Max. recommended PV generator 3 600 W 3 600 W 4 150 W
MPP range 280 – 510 V 140 – 510 V 165 – 510 V
Operating range 125 – 550 V 125 – 550 V 125 – 550 V
Rated DC voltage / start voltage 379 V / 150 V 379 V / 150 V 379 V / 150 V
Max. no-load voltage 600 V 600 V 600 V
Max. input current 11 A 2 x 11 A 2 x 11 A
Max. short circuit current Isc max 13.2 A 2 x 13.2 A 2 x 13.2 A
Number of MPP tracker 1 2 2
Connection per tracker 1 1 1
Max.input power per tracker 3100 W 3100 W 3600 W
AC output data
Rated output 3 000 VA 3 000 VA 3 450 VA
Max. power 3 000 VA 3 000 VA 3 450 VA
Line voltage 230 V (1 / N / PE) 230 V (1 / N / PE) 230 V (1 / N / PE)
Voltage range (Ph-N) 166 – 276 V 166 – 276 V 166 – 276 V
Rated frequency (range) 50 Hz / 60 Hz (45 – 65 Hz) 50 Hz / 60 Hz (45 – 65 Hz) 50 Hz / 60 Hz (45 – 65 Hz)
Rated current 13.0 A 13.0 A 15.0 A
Max. current 14.5 A 14.5 A 16.6 A
Reactive power / cos phi 0 – 95 % Snom / 0.30 ind. – 0.30 cap. 0 – 95 % Snom / 0.30 ind. – 0.30 cap. 0 – 95 % Snom / 0.30 ind. – 0.30 cap.
Max. total harmonic distortion 1.42 % 1.42 % 0.79 %
Number of grid phases 1 1 1
General data
Max. efficiency 97.2 % 97.2 % 97.2 %
Europ. efficiency 96.2 % 96.5 % 96.5 %
Standby consumption 3W 3W 3W
Circuitry topology transformerless transformerless transformerless
Mechanical data
Display graphical display + LEDs graphical display + LEDs graphical display + LEDs
Control units 4-way navigation + 2 buttons 4-way navigation + 2 buttons 4-way navigation + 2 buttons
Interfaces Ethernet, USB, RS485, optional: 4-DI Ethernet, USB, RS485, optional: 4-DI Ethernet, USB, RS485, optional: 4-DI
Fault signalling relay potential-free NOC max. 30 V / 1 A potential-free NOC max. 30 V / 1 A potential-free NOC max. 30 V / 1 A
DC connection DC plugs (SUNCLIX) DC plugs (SUNCLIX) DC plugs (SUNCLIX)
AC connection AC plug AC plug AC plug
Ambient temperature -25 °C – +60 °C 1) -25 °C – +60 °C 1) -25 °C – +60 °C 1)
Humidity 0 – 95 % 0 – 95 % 0 – 95 %
Max. installation elevation (above 2 000 m 2 000 m 2 000 m
Min. distance from coast 2 000 m 2 000 m 2 000 m
Cooling convection cooling convection cooling convection cooling
Protection class IP54 / NEMA 3R IP54 / NEMA 3R IP54 / NEMA 3R
Noise emission < 35 db (A) < 35 db (A) < 35 db (A)
HxWxD 560 x 367 x 227 mm 560 x 367 x 227 mm 560 x 367 x 227 mm
Weight 15 kg 15 kg 16.5 kg
Certifications
Safety IEC 62109-1 / -2, EN 61000-6-1 / -2 / -3, EN 61000-3-2 / -3 / -11 / -12
Grid connection rule overview see homepage / download area
3.7 TL1 4.0 TL1 4.6 TL1 5.0 TL1
4 400 W 4 800 W 5 500 W 6 000 W
170 – 510 V 185 – 510 V 215 – 510 V 235 – 510 V
125 – 550 V 125 – 550 V 125 – 550 V 125 – 550 V
379 V / 150 V 379 V / 150 V 379 V / 150 V 379 V / 150 V
600 V 600 V 600 V 600 V
2 x 11 A 2 x 11 A 2 x 11 A 2 x 11 A
2 x 13.2 A 2 x 13.2 A 2 x 13.2 A 2 x 13.2 A
2 2 2 2
1 1 1 1
3800 W 4100 W 4700 W 5140 W

3 680 VA 4 000 VA 4 600 VA 5 000 VA


3 680 VA 4 000 VA 4 600 VA 5 000 VA
230 V (1 / N / PE) 230 V (1 / N / PE) 230 V (1 / N / PE) 230 V (1 / N / PE)
166 – 276 V 166 – 276 V 166 – 276 V 166 – 276 V
50 Hz / 60 Hz (45 – 65 Hz) 50 Hz / 60 Hz (45 – 65 Hz) 50 Hz / 60 Hz (45 – 65 Hz) 50 Hz / 60 Hz (45 – 65 Hz)
16.0 A 17.4 A 20.0 A 21.7 A
17.7 A 19.5 A 22.0 A 22.0 A
0 – 95 % Smax / 0.30 ind. – 0.30 cap. 0 – 95 % Snom / 0.30 ind. – 0.30 cap. 0 – 95 % Snom / 0.30 ind. – 0.30 cap. 0 – 95 % Snom / 0.30 ind. – 0.30 cap.
0.79 % 0.79 % 0.79 % 0.79 %
1 1 1 1

97.2 % 97.2 % 97.2 % 97.2 %


96.5 % 96.6 % 96.6 % 96.6 %
3W 3W 3W 3W
transformerless transformerless transformerless transformerless

graphical display + LEDs graphical display + LEDs graphical display + LEDs graphical display + LEDs
4-way navigation + 2 buttons 4-way navigation + 2 buttons 4-way navigation + 2 buttons 4-way navigation + 2 buttons
Ethernet, USB, RS485, optional: 4-DI Ethernet, USB, RS485, optional: 4-DI Ethernet, USB, RS485, optional: 4-DI Ethernet, USB, RS485, optional: 4-DI
potential-free NOC max. 30 V / 1 A potential-free NOC max. 30 V / 1 A potential-free NOC max. 30 V / 1 A potential-free NOC max. 30 V / 1 A
DC plugs (SUNCLIX) DC plugs (SUNCLIX) DC plugs (SUNCLIX) DC plugs (SUNCLIX)
AC plug AC plug AC plug AC plug
-25 °C – +60 °C 1) -25 °C – +60 °C 1) -25 °C – +60 °C 1) -25 °C – +60 °C 1)
0 – 95 % 0 – 95 % 0 – 95 % 0 – 95 %
2 000 m 2 000 m 2 000 m 2 000 m
2 000 m 2 000 m 2 000 m 2 000 m
convection cooling convection cooling convection cooling convection cooling
IP54 / NEMA 3R IP54 / NEMA 3R IP54 / NEMA 3R IP54 / NEMA 3R
< 35 db (A) < 35 db (A) < 35 db (A) < 35 db (A)
560 x 367 x 227 mm 560 x 367 x 227 mm 560 x 367 x 227 mm 560 x 367 x 227 mm
18 kg 18 kg 18 kg 18 kg

IEC 62109-1 / -2, EN 61000-6-1 / -2 / -3, EN 61000-3-2 / -3 / -11 / -12


overview see homepage / download area
Feed in starts at less than 550 V DC
1)
Power derating at high ambient temperatures
KACO new energy GmbH | Carl-Zeiss-Str. 1 | 74172 Neckarsulm | Germany
Text und Abbildungen entsprechen dem technischen Stand bei Drucklegung. Technische Änderungen vorbehalten. Keine Haftung für Druckfehler.
Mit der aktuellen Version werden alle älteren Versionen ungültig. Die jeweils aktuelle Version finden Sie unter www.kaco-newenergy.com EN 5000724-01-180517