APU Generator (APU GEN) Control Switches
Push -
• AVAIL light illuminated: connects related APU generator to AC
electrical system
B-16481 - B-16483
Note: When the main deck cargo handling bus is powered by APU generator 2,
pushing APU generator 2 Control switch causes main deck cargo handling
bus to lose power.
• ON light illuminated: disconnects related APU generator from AC
electrical system
APU Generator Power Available (AVAIL) Lights
Illuminated (white) -
• APU generator power quality acceptable
B-16481 - B-16483
• main deck cargo handling bus powered when APU generator 2 AVAIL
light illuminated
• extinguishes when ON light illuminates
APU Generator Power ON Lights
Illuminated (white) -
• related APU generator connected to AC electrical system
• extinguishes when AVAIL light illuminates