VLF-6022CM (F) : VLF Cable Testing For Cables Rated To 35kV

This document summarizes the specifications and capabilities of the VLF-6022CM(F) VLF cable testing unit. It can output up to 62 kV peak at frequencies of 0.1, 0.05, and 0.02 Hz, allowing it to test cables rated up to 35 kV. Depending on the cable type and test frequency, it can test between 1-5 miles of cable. The unit is electromechanical and provides simple, reliable testing. An advanced E-Series model is also available for remote operation and reporting. Test voltages and durations are specified according to industry standards.

Uploaded by

Selk CL
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
248 views1 page

VLF-6022CM (F) : VLF Cable Testing For Cables Rated To 35kV

This document summarizes the specifications and capabilities of the VLF-6022CM(F) VLF cable testing unit. It can output up to 62 kV peak at frequencies of 0.1, 0.05, and 0.02 Hz, allowing it to test cables rated up to 35 kV. Depending on the cable type and test frequency, it can test between 1-5 miles of cable. The unit is electromechanical and provides simple, reliable testing. An advanced E-Series model is also available for remote operation and reporting. Test voltages and durations are specified according to industry standards.

Uploaded by

Selk CL
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

VERY LOW FREQUENCY AC HIPOT

VLF Cable testing for cables rated to 35kV

VLF-6022CM(F)
Features and Benefits
The High Voltage, Inc. VLF-6022CM(F) with its 62 kVac peak output,
is suitable for all testing of 35 kV cable per IEEE 400.2-2013. Its high
load capacity enables it to test up to approximately 15 miles of cable (at
.02 Hz), depending on type. Introduced in 1997, the VLF-6022CM(F) is
our simple and reliable electromechanical unit. For advanced features
such as remote operation, programming, professional reports and solid
state menu driven technology see our E-Series VLF-65E.

Specifications
Model VLF-6022CM(F)
120 volts, 60 Hz, 10 A peak, 5 A average Two-piece easy portability
Input
or 230 volts, 50/60 Hz, 6 A peak, 2.5 A average (F suffix)
Output 0-62 kVac peak, 0.1/0.05/0.02 Hz, Sinusoidal
Duty Continuous
1.1μF @ 0.10 Hz: 1 – 2 miles (1.6 - 3.2km) of 15 kV cable
1.5 – 3 miles (2.4 – 4.8km) of 25 kV cable
Load Rating 2 – 4.2 miles (3.2 – 6.8km) of 35kV cable
2.2μF @ 0.05 Hz: twice distances shown for 0.1Hz.
5.5μF @ 0.02 Hz: five times the distances shown for 0.1Hz
Metering Voltmeter: 0-62 kVac peak
Charging Current meter: 0 – 100 mA peak
Load capacitance meter: 0 – 6 microfarads
Adjustable test alarm timer
Shielded EPR output cable - 20 ft. (6 m)
Cable Lengths
Interconnect cable - 10 ft. (3 m)
Control: 26” w x 13” d x 16” h,
660 mm w x 330 mm d x 406 mm h, Controls are easy and reliable.
Sizes
HV Tank: 15” w x 10.25” d x 21.5” h
381 mm w x 267 mm d x 546 mm h
Control: 75 lbs., (34 kg)
Weights HV Tank: 120 lbs. (54 kg)
Optional Handcart available

IEEE 400.2-2013 Test Voltages for Sinusoidal VLF


Cable Rating Installation Acceptance Maintenance
(phase to phase) (phase to grd) (phase to grd) (phase to grd)
[kV rms] [kV peak] [kV rms] [kV peak] [kV rms] [kV peak]

5 9 13 10 14 7 10
8 11 16 13 18 10 14
15 19 27 21 30 16 22
20 24 34 26 37 20 28
25 29 41 32 45 24 34
28 32 45 36 51 27 38
30 34 48 38 54 29 41
35 39 55 44 62 33 47
E-Series VLF-65E
Test duration should be 30 – 60 minutes at the above voltages.

ISO 9001 2008 The World’s Source for High Voltage Test Equipment MADE IN THE USA

High Voltage, Inc. • hvinc.com • p. 518.329.3275 • f. 518.329.3271 • 31 County Route 7A • Copake, NY 12516 USA