SDS Error: Refer To 3x02228 I/O C.

This document provides troubleshooting steps for an SDS Error, which occurs when an unreasonable SDS input signal is detected while a car is stopped or running. The steps include: 1) Checking the P48V power, 2) Checking circuit wiring and connector contact status, 3) Checking the input buffer status by applying DC48V power and monitoring signal changes, and 4) Checking SDS operation by inputting signals to SD1-6U(D) individually. If no signal differences are detected, the input buffer may have failed and the PCB would need replacing.

Uploaded by

Quang Pham Duy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
50% found this document useful (2 votes)
92 views1 page

SDS Error: Refer To 3x02228 I/O C.

This document provides troubleshooting steps for an SDS Error, which occurs when an unreasonable SDS input signal is detected while a car is stopped or running. The steps include: 1) Checking the P48V power, 2) Checking circuit wiring and connector contact status, 3) Checking the input buffer status by applying DC48V power and monitoring signal changes, and 4) Checking SDS operation by inputting signals to SD1-6U(D) individually. If no signal differences are detected, the input buffer may have failed and the PCB would need replacing.

Uploaded by

Quang Pham Duy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Point of ● Run CPU ● DI120-150

TCD 119 SDS Error Application


Detection ○ Speed CPU ● DI180-420

[Meaning ] When SDS input signal is unreasonable while car stops or is [Actions to take]
running(When no signal is inputted at operation position or
signal is inputted at stop position). 1. Check P48V power.
[Diagram ] Refer to 3x02228 I/O C.[2] 2. Check circuit wiring and connector contact status.
(Refer to detailed circuit diagram 3x2228)
3. Check input buffer status.
Check signal changes of input buffer while applying
DC48V power to connectors listed below.
230

DOR-230
Device DOR-200 Input ADDRESS 취부거리(mm)
Distance
230 Name Conn. No Signal
SD1U INB/05 IS_SD1U 0x500F 400
230
SD2U INB/06 IS_SD2U 0x5010 1400
SD3U INB/07 IS_SD3U 0x5011 2800
SD4U INB/01 (*1) IS_SD4U 0x5012 5600
230 SD5U INB/02 (*1) IS_SD5U 0x5013 7600
SD6U INB/03 (*1) IS_SD6U 0x5014 14000
SD1D INB/08 IS_SD1D 0x5007 400
230
SD2D INB/09 IS_SD2D 0x5008 1400
230
SD3D INB/10 IS_SD3D 0x5009 2800
SD4D INB/04 (*1) IS_SD4D 0x500A 5600
230(2) SD5D INB/05 (*1) IS_SD5D 0x500B 7600

230(2)
(* Cycle 1) SD4~6U(D) is connector No. of DOR -230(2) PCB.
If there is no signal difference input buffer may be
230(2)
failed (Replace PCB)
230(2)
4. Check SDS operation
Check signal input status while operating SD1~6U(D)
230(2)
one after another.