(E-Rev1)
Utility Software
Data Connection For 22S
Instruction Manual
Please read this instruction manual
carefully before installation.
LICENSE AGREEMENT
READ THE TERMS OF THIS AGREEMENT CAREFULLY.
Fujikura Co., Ltd. (hereinafter referred to as "Fujikura") provides Data
Connection For 22S and the attached files (hereinafter referred to as "licensed
product") for use on the following terms and conditions. If you do not agree to
the terms of this license, do not install, copy, or otherwise use this licensed
product.
1. Licensing Policy
The software may be installed in your computers as long as you comply the
terms and condition of this License Agreement.
2. Prohibited Uses
You may NOT:
(a) Sell, lend, transfer, rent or allow any other person these actions.
(b) You may not rent, lease, or lend the software.
(c) Decompile, or reverse engineer the software.
(d) Export, re-export, or import the software from/to another country.
3. Attribution of Intellectual Property Right
This Agreement does not grant you any Intellectual Property Rights of the
licensed product.
Use of the licensed product, unless pursuant to the terms of a license granted
by Fujikura or as otherwise authorized by law, is an infringement of
Intellectual Property Rights.
4. Limitation of Liability
(a) Fujikura assumes no liability and shall not be responsible for, and you
hereby assume all risk of: any linkage to any communications with any
third parties, and any damage resulting from any computer viruses or from
linkage to any third party sites. Fujikura shall not be responsible for any
direct, indirect, incidental, consequential damages arising out of your use.
(b) Fujikura will not be liable for any consequential damages under any
circumstances, unless such exclusion is forbidden by law.
5. Non-assignability of Rights and Obligations
Licensee may not assign or transfer any rights or obligations of the licensed
product under this Agreement without prior written approval from Fujikura.
6. Termination
Your rights under this License will terminate automatically without notice from
Fujikura if you fail to comply with any term(s) of this License Agreement.
Upon the termination of this License, you shall cease all use of the licensed
product and destroy all copies, full or partial, of the licensed product.
7. Term of Limitation
This license agreement shall be effective until it goes into effect from the time
of being used of this product, and the end of use of this product or Fujikura
cancels this license agreement by regulation of the 6th clause.
Table of contents
1 Introduction ....................................................................... 2
2 System Requirements......................................................... 2
3 Install ................................................................................. 3
4 Install the Software............................................................ 4
5 How to use the Data Connection For 22S ...................... 14
5.1 Splice Result Memory ......................................................................................... 15
5.2 Download, Save, Edit and Upload Settings ...................................................... 18
5.3 Firmware Update ................................................................................................ 24
5.4 Update Data Connection..................................................................................... 31
6 Uninstall the Data Connection........................................ 32
7 Troubleshooting ............................................................... 35
7.1 Installation of the Device Driver Failed ............................................................ 35
7.2 Data Connection Does Not Run ......................................................................... 39
7.3 Installation of Firmware Failed ......................................................................... 40
7.4 USB Communication Does Not Works .............................................................. 40
8 Contact Address ............................................................... 41
1
Introduction / System Requirements
1 Introduction
Data Connection For 22S ("Data Connection") is the software included in the
package of 22S; the splicer series manufactured by Fujikura.
Read this installation manual before installing Data Connection
2 System Requirements
Computer and processor 1.6 gigahertz(GHz) processor or higher
(In case CoreTMi3, Intel Corp)
Operating System Microsoft Windows Vista SP2 (32bit)
Microsoft Windows 7 SP1 (64bit / 32bit)
Microsoft Windows 8
*The operating system must be updated by
Windows Update
Memory 2GB (Windows Vista SP2)
4GB (Windows 7 SP1,Windows 8)
Hard Disk 100MB available space
Drive CD-ROM or DVD drive
Display 1024x768, or higher resolution
24bit, or higher color
Other USB 2.0 Port
Capable of Internet Access, 56kbps or higher
Broadband access is recommended
2
Install
3 Install
Login to the PC using an account with administrator privilege
Administrator privilege is required when installing the software.
If you do not have an account which has administrator privilege, ask the
supervisor of the PC for installation.
Exit all programs running on the PC
Exit all programs running on the PC. Some programs may prevent
installation. Specifically do not install Data Connection when the
communication software for another series of splicer is running.
Perform Windows Update or Microsoft Update
Operating System must be updated by latest update.
Perform Windows Update or Microsoft Update before starting installation.
To go to Windows Update or Microsoft Update, select [Start] > [All Programs]
> [Windows Update] or [Microsoft Update].
Internet connection is necessary in order to perform Windows
Update or Microsoft Update.
3
Install the Software
4 Install the Software
(1) Confirm that the USB cable is not connected.
(2) Insert the instruction CD into CD-ROM or DVD drive.
(3) After a few seconds, instruction menu will be shown automatically.
If the menu is not shown, double-click "Utility.exe" which is in the root of
the instruction CD.
(4) Click [Load Data Connection Software] button.
4
Install the Software
"User Account Control" window may be shown during installation.
Click [Yes] button if "Do you want to allow the following program
from an unknown publisher to make changes to this computer?"
message is shown.
Click [Continue] button if "Windows needs your permission to
continue" message is shown.
If you run the installer without administrator privilege, the following
message will be shown. In this case, login with an administrator
account, and run the installer.
5
Install the Software
(5) License Agreement confirmation window will be shown.
Click [ACCEPT] button if you accept the License Agreement.
If you do not accept the License Agreement, click [DECLINE] button.
In this case, installation will be cancelled.
If the DataConnection has already been installed, the
uninstall menu will be shown.
(6) Installation of necessary software and driver will start.
Necessary software and driver for Data Connection
Microsoft .NET Framework 4 Client Profile
Microsoft Visual C++ 2010 Redistributable
Usb Driver
6
Install the Software
(a) Installation of Microsoft .NET Framework 4 Client Profile
If "Microsoft .NET Framework 4 Client Profile" has not been installed,
[Microsoft .NET Framework 4 Client Profile Setup] window will be
shown.
If the installation is not necessary, the following window will
not be shown. Proceed to following page
Check [I have read and accept the license terms] and click [Install]
button.
When the following window is shown, click [Finish] button to complete
the installation.
7
Install the Software
(b) Installation of Microsoft Visual C++ 2010 Redistributable
If "Microsoft Visual C++ 2010 Redistributable" has not been installed,
[Microsoft Visual C++ 2010 Redistributable Setup] window will be
shown.
If the installation is not necessary, following window will not
be shown. Proceed to following page
Check [I have read and accept the license terms] and click [Install]
button.
When the following window is shown, click [Finish] button to complete
the installation.
8
Install the Software
(c) Uninstallation of existing USB driver
If the old version of USB driver has been installed, [Confirm Uninstall]
window will be shown.
If the uninstallation is not necessary, the following window
will not be shown. Proceed to following page
Click [OK] button.
When the following window is shown after the uninstallation, click
[Finish] button to complete the uninstallation.
9
Install the Software
(d) Installation of USB driver
[FjkUsbDv InstallShield Wizard] window will be shown.
When the following window is shown after the installation, click
[Finish] button to complete the installation.
10
Install the Software
If the following message is shown, click [Install] button.
If the following security message was shown, click "Install this driver
software anyway".
11
Install the Software
(7) Installation of the main program of Data Connection will start.
During the installation, the following message is shown.
(8) When the following message is shown, click [OK] button to complete the
installation.
(9) Click [Exit] button to close the menu.
12
Install the Software
(10) Install device driver.
Turn on the splicer and connect to the PC with USB cable.
"Installing device driver software" message will be shown at
notification area in task bar.
When the driver installation is complete, "Device driver software
installed successfully" message will be shown.
If the "Device driver software installed successfully" message
was not shown in a few minutes, please read [Installation of the
Device Driver Failed] in [Chapter 7: Troubleshooting]
13
How to use the Data Connection 22S
5 How to use the Data Connection For 22S
Double-click the shortcut on the desktop or click "Data Connection For 22S"
in the [Start] > [All Programs] > [Fujikura] menu.
or
If the Data Connection does not run, please read
[Data Connection Does Not Run] in [Chapter 7: Troubleshooting]
Turn on the splicer and connect to PC with USB cable.
If the USB communication is ready, "CONNECTED" message will be shown
at the bottom left of Data Connection window.
If the "CONNECTED" message was not shown, please read [USB
Communication Does Not Works] in [Chapter 7: Troubleshooting]
14
How to use the Data Connection 22S
5.1 Splice Result Memory
In [Memory] page, the splice result memory can be downloaded and saved.
Splice result memory can only be downloaded.
It can not be uploaded to splicer.
5.1.1 Download Splice Result Memory
(1) Confirm that the splicer is in "READY" state.
Press [RESET] key to change the splicer to "READY" state.
(2) Select [Memory] page, and click [Download All Memories] button to
download all stored splice results.
15
How to use the Data Connection 22S
5.1.2 Save Splice Result Memory
(1) Click [Save File] or [Save As .XLS] button to save the splice result
memories.
[Save File]
Data is saved to a file. Only Data Connection can open this data file.
[Save As .XLS]
Data is exported as XLS file so that the data can be opened by
Microsoft Excel. Note that Data Connection cannot open this exported
file.
16
How to use the Data Connection 22S
5.1.3 Open Splice Result Memory Data
This function is available without USB connection.
Select [Memory] page, and click [Open File] button.
When the file open dialog is shown, select the saved file.
17
How to use the Data Connection 22S
5.2 Download, Save, Edit and Upload Settings
In [Settings] page, the splice settings can be downloaded, saved, edited and
uploaded. [Setting] page consists of 3 additional pages.
Please note that some items are displayed on the page which is different
from splicer.
Item Page in Splicer Page in Data Connection
Splice Mode Splice Menu Splice Mode Settings
Heater Mode Heater Menu Heater Mode Settings
Pause
Splice Menu
Auto Start
Auto Start Heater Menu
Splice Settings Other Settings
Maintenance Settings
Setting Menu
Machine Settings
Menu Lock Settings
18
How to use the Data Connection 22S
5.2.1 Download Settings
Confirm that the splicer is in "READY" state.
Press [RESET] key to change the splicer to "READY" state.
Select [Settings] page.
Download all of [Splice Mode Settings], [Heater Mode Settings] and [Other
Settings]
Click [Download All Settings] button
Download one of [Splice Mode Settings], [Heater Mode Settings] and
[Other Settings]
Select page you want to download, and click [Download] button.
(In above picture, [Splice Mode Settings] will be downloaded.)
In [Splice Mode Settings] and [Heater Mode Settings] page, you
can select the mode number to download specifying [Start No.]
and [End No.].
19
How to use the Data Connection 22S
5.2.2 Save Settings
Click [Save File] or [Save As .XLS] button to save the settings. When file
save dialog is shown, input file name and destination.
[Save File]
Data is saved to a file. Only Data Connection can open this data file.
[Save As .XLS]
Data is exported as XLS file so that the data can be opened by Microsoft
Excel. Note that Data Connection cannot open this exported file.
20
How to use the Data Connection 22S
5.2.3 Open Settings Data
This function is available without USB connection.
Select [Settings] page and click [Open File] button.
When file open dialog is shown, select the saved file.
21
How to use the Data Connection 22S
5.2.4 Edit Settings
Click the cell to edit.
There are specific methods to change the setting. Follow the Data
Connection display to change the setting.
When the value of "Fiber Type" is changed, all parameters in
the selected mode will be reset to original factory values.
When the value of "Sleeve Type" is changed, all parameters in
the selected mode will be reset to original factory values.
(a) Select item from list.
(b) Change value with bar.
(c) Input with keyboard directly.
22
How to use the Data Connection 22S
5.2.5 Upload Settings
Confirm that the splicer is in "READY" state.
Press [RESET] key to change the splicer to "READY" state.
Upload all of [Splice Mode Settings], [Heater Mode Settings] and [Other
Settings]
Click [Upload All Settings] button
Upload one of [Splice Mode Settings], [Heater Mode Settings] and [Other
Settings]
Select the page you want to upload, and click [Upload] button.
(In the following picture, only [Splice Mode Settings] will be uploaded.)
In [Splice Mode Settings] or [Heater Mode Settings] page, you
can select the mode number to upload specifying the [Start No.]
and [End No.]
23
How to use the Data Connection 22S
5.3 Firmware Update
[Firmware Update] page provides firmware update function of the splicer.
When the PC is connected to internet, Data Connection downloads firmware
update file from our server and installs it to the splicer.
Otherwise, if you have the firmware update file, the firmware can be installed
to splicer using Data Connection without internet connection.
[1]
[2] [3]
[1] Information of latest firmware
[2] Checkbox to enable check of the firmware information at logon. When the
information is updated, message will be shown.
[3] Button to check the firmware information.
24
How to use the Data Connection 22S
5.3.1 Install the Latest Firmware Released on the Internet
During firmware installation,
Do not turn off the splicer.
Do not disconnect USB cable.
(1) Confirm the following
The splicer is connected to PC with USB cable.
The splicer is in "READY" state.
The PC is connected to Internet.
(2) Select [Firmware Update] page, and click [Download and install latest
firmware] button.
If the update file can not be downloaded, "Connect the PC to
the internet" message will be shown. In this case, confirm the
internet connection using web browser.
If the message is shown despite the PC can access the
internet, the firewall of network system may block
downloading the file. Please consult the administrator of your
network system.
25
How to use the Data Connection 22S
(3) Firmware update will start, and status bar at bottom left of Data
Connection will progress.
If the latest firmware has already been installed to the splicer, the
following message will be shown and firmware will not updated.
26
How to use the Data Connection 22S
(4) When the following message is shown, click [OK] button to finish the
update. Confirm that the splicer restarts and "READY" state is indicated
on screen.
If the firmware update failed, the following problem will occur
The splicer can not be turned on.
(The splicer does not restart after firmware update)
"READY" state is not indicated on screen although the
splicer is turned on.
When above problem occurs, please read [Installation of
Firmware Failed] in [Chapter 7: Troubleshooting]
27
How to use the Data Connection 22S
5.3.2 Install the Firmware Using an Update File
During firmware installation,
Do not turn off the splicer.
Do not disconnect USB cable.
(1) Confirm the following
The splicer is connected to PC with USB cable.
The splicer is in "READY" state.
(2) Select [Firmware Update] page, and click [Install using an update file]
button.
28
How to use the Data Connection 22S
(3) When file open dialog is shown, select the update file.
(4) Firmware update will start, and status bar will progress.
29
How to use the Data Connection 22S
If the latest firmware has already been installed to the splicer, the
following message will be shown and firmware will not updated.
(5) When the following message is shown, click [OK] button to finish the
update. Confirm that the splicer restarts and "READY" state is indicated
on screen.
If the firmware update failed, the following problem will occur
The splicer can not be turned on.
(The splicer does not restart after firmware update)
"READY" state is not indicated on screen although the
splicer is turned on.
When above problem occurs, please read [Installation of
Firmware Failed] in [Chapter 7: Troubleshooting]
30
How to use the Data Connection 22S
5.4 Update Data Connection
Data Connection has self-update feature. If the following message is shown
when Data Connection is starting, click [OK] button to start updating Data
Connection.
Internet connection is necessary for self-update.
31
Uninstall the Data Connection
6 Uninstall the Data Connection
(1) Confirm that the USB cable is not connected.
(2) Insert the instruction CD into CD-ROM or DVD drive.
(3) After a few seconds, instruction menu will be shown.
If the menu is not shown, double-click "Utility.exe" which is in the root of
the instruction CD.
(4) Click [Load Data Connection Software] button.
32
Uninstall the Data Connection
(5) When the following window is shown, click [Uninstall] button.
(6) When the [Confirm Uninstall] message is shown, click [OK] button to
continue.
33
Uninstall the Data Connection
(7) When [Maintenance Complete] window is shown, click [Finish] button.
(8) When the following message is shown, click [OK] button to complete
installation.
(9) Click [Exit] button to close menu.
34
Troubleshooting
7 Troubleshooting
When trouble occurs during installation or when using Data Connection,
please read this chapter.
If the trouble is not fixed despite performing the following
procedure, please contact us.
7.1 Installation of the Device Driver Failed
When first connecting to PC, the device driver should be installed
automatically. If the installation failed (the following window was shown),
install device driver according to procedure listed in the following pages.
35
Troubleshooting
(1) Open [Control Panel] > [System] > [Hardware] > [Device Manager]
menu to open "Device Manager".
(2) Right-click on "FJK-GS-003" in the [Jungo] or [Other devices] and
select "Update Driver Software…".
If "FJK-GS-003" is not listed, confirm the following.
The splicer is connected to PC with USB cable.
The splicer is turned on.
36
Troubleshooting
(3) Click "Browse my computer for driver software".
(4) Click [Browse…] button and select "C:\FjkUsbDv". After selecting,
check [Include subfolders] and click [Next] button.
37
Troubleshooting
(5) When the following message is shown, click "Install this driver software
anyway".
(6) When the following window is shown, click [Close] button
(7) Close "System Properties" and "Device Manager".
38
Troubleshooting
7.2 Data Connection Does Not Run
Data Connection is not shown although the icon was clicked
(a) Windows may not be updated to latest version. Perform Windows
Update or Microsoft Update to update Windows.
(b) Memory capacity or CPU speed may be insufficient to meet the system
requirement.
Close other running applications.
Confirm that memory capacity and CPU speed meet the system
requirement.
".NET Framework Initialization Error" is shown when Data Connection
is launched
(a) "Microsoft .NET Framework 4 Client Profile" may not be installed.
Double-click "dotNetFx40_Client_x86_x64.exe" in "DotNetFx" folder in
instruction CD to install "Microsoft .NET Framework 4 Client Profile".
(b) Windows may not be updated to latest. Perform Windows Update or
Microsoft Update to update Windows.
.NET Framework error is shown when Data Connection is launched
(a) "Microsoft Visual C++ 2010 Redistributable" may not be installed.
Double-click following file in "vcredist" folder in instruction CD to install
"Microsoft Visual C++ 2010 Redistributable".
64bit OS: vcredist_x64.exe
32bit OS: vcredist_x86.exe
(b) Windows may not be updated to latest version. Perform Windows
Update or Microsoft Update to update Windows.
39
Troubleshooting
7.3 Installation of Firmware Failed
If the installation of firmware failed, the following problem will occur.
When the problem occurs, perform the following procedure to install the
firmware again.
The splicer can not be turned on (Splicer does not restart after
installation).
The splicer turns on, but "READY" state is not indicated.
(1) Turn off the splicer.
(2) Then keep holding down the [RESET] key and turn on the splicer again.
(Keep holding down keys until "SOFTWARE UPDATE MODE" is
indicated on the screen.)
(3) In the [Firmware Update] page of Data Connection, click [Download and
install latest firmware] button to install the firmware again.
If the update failure persists or you have some questions
about this procedure, please contact us.
,
7.4 USB Communication Does Not Works
Confirm that the "CONNECTED" is indicated at bottom left of Data
Connection window.
"DISCONNECTED" is indicated
(a) Confirm that the splicer is connected to PC with USB cable.
(b) Confirm that the splicer is turned on.
(c) Confirm that the splicer is in "READY" state.
Press [RESET] key to change splicer to "READY" state.
(d) If the external USB hub is used, connect the USB cable to PC directly.
(e) USB driver may not be installed correctly.
Install the Data Connection again.
"Communication Error" message was shown during downloading or
uploading ("CONNECTED" is indicated)
(a) Confirm that the splicer is in "READY" state.
Press [RESET] key to change splicer to "READY" state.
(b) If the external USB hub is used, connect the cable to PC directly.
(c) The firmware version of splicer may not be the latest.
If the firmware is not the latest, update the firmware of splicer.
40
Contact Address
8 Contact Address
Inquiries concerning products should be made to the nearest distributor or
one of the following:
Fujikura Europe Ltd.
C51 Barwell Business Park
Leatherhead Road, Chessington, Surrey KT9 2NY
England
Tel. +44-20-8240-2000 (Service: +44-20-8240-2020)
Fax. +44-20-8240-2010 (Service: +44-20-8240-2029)
URL http://www.fujikura.co.uk
AFL Telecommunications
260 Parkway East
Duncan, SOUTH CAROLINA 29334
U.S.A.
Tel. +1-800-235-3423 (Service: +1-800-866-3602)
Fax. +1-864-433-5560 (Service: +1-800-433-5452)
P.O.Box 3127 Spartanburg, SC 29304-3127
URL http://www.AFLglobal.com
Fujikura Asia Ltd.
438A Alexandra Road, #08-03 Blk A Alexandra Techno Park,
SINGAPORE, 119967
Tel. +65-6-2711312 Fax. +65-6-2780965
URL http://www.fujikura.com.sg
Fujikura Ltd.
Optical Fiber & Equipment Department
International Sales & Marketing
1-5-1 Kiba, Koto-ku, Tokyo 135-8512
Japan
Tel. +81-3-5606-1164 Fax. +81-3-5606-1534
URL http://www.fujikura.co.jp
------------------------------------ End of Document -------------------------------------
41