26984284
26984284
1950's 1952 Grant-in-aid for industrial technology research was offered to our design of shock-wave measurement device. Two
years later, Japan’s first domestic oscilloscope was put on the market (trademark registered as SYNCHROSCOPE).
1957 Listed on the first section of the Tokyo Stock Exchange.
1960's 1961 Development and manufacture of proprietary CRT for waveform observation started.
1962 Development and manufacture of proprietary IC started.
1970's 1970 The first domestic IC oscilloscope released, providing a compact and light oscilloscope.
1974 Colona-Denshi Co., Ltd., (present name: Iwatsu Test Instruments Corporation, Aizu factory) was established in
Wakamatsu, Aizu, Fukushima as a production base for electric measurement equipment.
1990's 1991 An overseas affiliate Iwatsu (Malaysia) Sdn. Bhd. (presently a consolidated subsidiary of Iwatsu Electric Co., Ltd.)
was established.
1999 Digital oscilloscopes were joint-developed with LeCroy Corporation.
2000's 2000 Iwatsu TME Service Co., Ltd., (present name: Iwatsu Test Instruments Corporation), a service company specializing in
measurement equipment, was established.
2002 Iwatsu Test Instruments Corporation was established from the measurement division of Iwatsu Electric Co., Ltd.
The world’s only 1GHz bandwidth analog storage oscilloscope, TS-81000 was released, featuring high speed high
brightness writing.
2004 50th anniversary of oscilloscope sales.
Digital oscilloscopes to support Microsoft® Windows® OS were released.
Digital multi-meter with two-channel input, VOAC7520 was released.
2005 Full-scale entry into the field of measurement for the automobile industry.
2006 Four models of digital oscilloscope DS-5100 series were released, providing high performance with low cost.
Full-scale entry into the field of measurement for high performance electromagnetic steel sheets with the world’s first
V-H analyzer IE-1131B.
2007 An isolation system for power electronics, DM-8000 was released, providing highly accurate measurement of ultra-
high voltages.
2009 Full-scale entry into the field of measurement for power semiconductors, with three models of CS-3000 series, a
semiconductor curve tracer supporting high current at 1,000A.
Capacitance displacement meter with high resolution and high stability, the ST-3541 series were released.
2011 Two models of CS-10000 series, a semiconductor curve tracer supporting ultra-high voltage high current, and
three models of CS-5000 series were released, providing support to all needs in the field of measurement for power
semiconductors.
Genuinely domestic highly accurate measurement equipment, radiation dosimeter SV-1000/SV-2000 were released.
Semiconductor Curve Tracer 4
CS-3300, CS-3200, CS-3100, CS-5300, CS-5200, CS-5100, CS-10800, CS-10400
Digital Oscilloscope 10
DS-5554, DS-5552, DS-5534, DS-5532, DS-5524, DS-5522, DS-5514, DS-5512
Analog Oscilloscope 12
SS-7847A, SS-7840A, SS-7830A, SS-7840AP, SS-7830AP
Digital Multimeter 20
VOAC 7523H, VOAC 7520H, VOAC 7522H, VOAC 7521H
Universal Counter 24
SC-7207H, SC-7206H, SC-7205H, SC-7217
B-H Analyzer 32
SY-8218, SY-8219
S e m i c o n d u c t o r C u r v e Tr a c e r
CS-3200 / CS-3300
CS-3100
CS-5300
Best suited for measuring the breakdown of a power device which has 3,300V withstand voltage
• Maximum peak voltage: 5,000V (high-voltage mode for all models)
• Maximum peak current: 1,000A (CS-5300 high-current mode)
• The CS-5000 Series achieved 5,000V of max. peak voltage with the same size as the CS-3000 Series.
*All models of CS-5000 Series are equipped with the CS-303 (Fixture M) as standard.
Li ne up
Items Product name Model number Remarks
Semiconductor curve tracer CS-3300 3,000V / 1,000A with HC mode - CS-302 / CS-500
Semiconductor curve tracer CS-3200 3,000V / 400A with HC mode - CS-302 / CS-500
Semiconductor curve tracer CS-3100 3,000V / without HC mode - CS-301 / CS-500
Main unit
Semiconductor curve tracer CS-5300 5,000V / 1,000A with HC mode - CS-303 / CS-500
Semiconductor curve tracer CS-5200 5,000V / 400A with HC mode - CS-303 / CS-500
Semiconductor curve tracer CS-5100 5,000V / without HC mode - CS-303 / CS-500
Fixture S CS-301 Standard for CS-3100.
Fixture
Fixture M CS-302/CS-303 CS-302 standard for CS-3200,CS-3300 and CS-303 standard for all CS-5000 series
Test adapter CS-500 A test adapter is supplied with the main unit for both CS-301, CS-302 and CS-303.
Test adapter
TO-type test adapter CS-501 Socket suited to the TO-type package (with three terminals) for both CS-301, CS-302 and CS-303.
Small alligator clip (red) x 10 CS-001 Option for CS-302/CS-303 fixture M
Alligator clip
Small alligator clip (black) x 10 CS-002 Option for CS-302/CS-303 fixture M
Semiconductor parameter search CS-800 A software option to be installed in the CS-3000 series and CS-5000 series.
Software options
Semiconductor parameter measurement CS-810 To be used on the (optional) PC when the CS-800 is installed in the main unit.
4
User-friendly measurement screen
Graphical configuration selection Transistor I-V characteristic example Vbe and Ic waveforms in the High-current pulse mode
(TRACE mode) (WAVE mode)
9
3
10
4
11
2
5 12
13
5
Observation of I-V curves as well as applied waveforms of voltage and current
Application of the current and voltage pulses
in the high current mode connection status
of a measurement
device
Current Waveform
The pulse widths of the applied current and voltage and the measurement point can be specified in a range between 50µs and 400 µs (CS-3200 and CS-3300).
Vge=6V
Vge=5.5V
Vge=5V
Vge=4.5V
Vge=3-4V
The SWEEP TYPE can be selected from DOWN, UP, and CUSTOM (all Typical I-V characteristics measurement on MOSFET
models).With CUSTOM specified, the range between specified values
can be swept.
Example of
automatic Vth
measurement
LIMIT SWEEP Vth and hFE SETUP
If the voltage and current limit values are specified before SWEEP Vth and hFE can be automatically seeked and measured.
operations, the operations stop at the next measurement point after
the limit value has been exceeded.
6
CS-810 semiconductor parameter measurement (optional) Remote tool
This is a PC application used to connect the main unit incorporating CS-800 and an (optional) PC by a LAN. This If the use of USB memory is not permitted for security
application automatically performs measurements by applying the measurement conditions specified using the PC to reasons, a copy of the screen, measurement results
determine whether the data is appropriate. in the CSV format, and other data can be directly
transferred to the PC via LAN.
*The Remote tool can be downloaded from the Iwatsu website
(freeware)
Accessories
Standard accessories for CS-3100 Standard accessories for CS-3300 and CS-3200
When the CS-501 is
mounted. When the patch
panel removed
CS-500 test adapter CS-501 TO type test adapter CS-001 (red x 10pcs.),
The CS-500 Test adapter is supplied with the product. This socket is suited to the CS-002 (black x 10pcs.)
Use this adapter TO type package (with three
Small alligator clips
to connect the terminals). The supported lead
These small alligator clips can be
prepared jig to the distance is from 1.52 to 4.57mm.
attached to the wire set supplied
fixture.
with the CS-302 fixture.
CS-001 CS-002
CS-10800/CS-10400 Custom Order Ideal for measuring the withstand voltage characteristic of
high voltage diode thyristors
Best suited for measuring the
characteristics of power devices
Output section
Commercial power supply half-
Voltage waveform
• Ultra-high voltage and high current wave rectification waveform
The following HV and HC functions are added Maximum voltage 10kV at peak (without load)
to the CS-3100 Maximum current 100mA at peak
Display section
High voltage mode 10kV(+DC only) Voltage axis 50V/div to 1,000V/div,
8,000A(CS-10800) sensitivity 5 ranges at 1-2-5 step
4,000A(CS-10400) Current axis 0.1mA/div to 10mA/div,
High current mode sensitivity 7 ranges at 1-2-5 step
Pulse width/Pulse interval/
Measuring point variable
7
Semiconductor Curve Tracer Series Specifications
Model CS-3300 CS-3200 CS-3100
Collector supply
High voltage1 AC, ± Rectified SIN, ± DC, ± LEAKAGE
Mode High voltage2 ̶
High current Pulse only ̶
120mW, 1.2W, 12W, 120W, 390W
High voltage1
Maximum *390 W can be selected excluding the maximum peak voltage setting at 3,000V range.
peak power
High voltage2 ̶
High current 400W, 4kW, 10kW 400W, 4kW ̶
Maximum peak current Maximum peak voltage
(maximum peak pulse current)
High voltage mode1 75mA(150mA) 3,000V(2,500V / AC)
750mA(1.5A) 300V
7.5A(15A) 30V
The stray capacitance between the collector terminal and the ground of the fixture is compensated by the hardware in the high voltage mode. Digital compensation is
Loop compensation
also available.
The pulse width is variable in the range from 50µs to 400 µs.
Pulse width /
Measurement points can be specified ̶
measurement point
(with a resolution of 10 µs/step).
Maximum data points 20 to 1,000 points can be specified per trace.
MEASUREMENT MODE REPEAT, STOP/SINGLE, SWEEP
Step generator
Current mode Amplitude range: 50nA to 200mA, 21 ranges, 1-2-5 step Maximum current: ± 2A / Offset: ±10 times STEP AMPLITUDE setting
Voltage mode Amplitude range: 50mV to 2V, 6 ranges, at 1-2-5 step Maximum voltage:±40V / Offset: ±10 times STEP AMPLITUDE setting
Staircase wave: 2times of 50Hz or 60Hz (50Hz or 60Hz in the AC mode) Staircase wave:
Step rate Pulse : The pulse changes in the range from 80ms to 1,000 ms. 2times of 50Hz or 60Hz
(The lowest frequency limited by the maximum peak power consumption setting.) (50Hz or 60Hz in the AC mode)
Pulse step The pulse width is variable in the range from 50µs to 400µs at 10µs resolution.
Number of steps 0 to 20steps
AUX output
Range OFF, -40 to +40V, variable with at 100mV resolution
Vertical axis
High voltage 1µA/div to 2A/div, 20 renges, at 1-2-5 step
Collector
100mA/div to 100A/div, 100mA/div to 50A/div,
current High current ̶
10 ranges, at 1-2-5 step 9 ranges, at 1-2-5 step
Emitter current(LEAKAGE) 1 nA/div - 2 mA/div, 20 ranges, at 1-2-5 step
Horizontal axis
Collector High voltage 50mV/div to 500V/div, 13 ranges, at 1-2-5 step 50mV/div to 1,000V/div, 14 ranges, at 1-2-5 step
voltage High current 50mV/div to 5V/div, 7 ranges, at 1-2-5 step ̶
Base / emitter voltage 50mV/div to 5V/div, 7 ranges, at 1-2-5 step
Miscellaneous
Display 8.4-inch color TFT-LCD (SVGA 800 x 600 pixels)
Internal: Memory (setup: 256, REF waveform: 4)
Data save / recall
External: Removable storage connected to the USB port (setup, waveform save/recall, screen hard copy of display (BMP, TIFF, PING)
USB 1 port (USB1.1) Setup, Waveform Save/Recall, Hard copy of display (BMP, TIFF, PING)
Remote control Remote control by LAN: 1 port (100BASE-TX)
Power supply AC 100V - AC240V, single phase, 50Hz/60Hz, Approx. 500VA
Mechanism section
424 (W) x 555.2 (L) x 354.5 (H) 424 (W) x 555.2 (L) x 221 (H)
Dimensions (mm)
(without the external projection portion) (without the external projection portion)
Weight Approx. 45kg (without optional accessories) Approx. 30kg (without optional accessories)
8
Model CS-5300 CS-5200 CS-5100 CS-10800 CS-10400
Collector supply
High voltage1 AC, ± Rectified SIN, ± DC, ± LEAKAGE
Mode High voltage2 ̶ +DC
High current Pulse only ̶ Pulse only
120mW, 1.2W, 12W, 120W, 390W 120mW, 1.2W, 12W,120W, 390W
High voltage1 *120mW and 390 W can be selected excluding the maximum peak voltage setting at 5,000V *390 W can be selected excluding the maximum peak voltage
Maximum range. setting at 3,000V range.
peak power
High voltage2 ̶ 4kW
High current 400W, 4kW, 10kW 400W, 4kW ̶ 600W, 6kW, 60kW, 64kW 600W, 6kW, 60kW
Maximum peak current Maximum peak voltage Maximum peak current Maximum peak voltage
(maximum peak pulse current) (maximum peak pulse current)
High voltage mode1 25mA(25mA) 5,000V(2,500V / AC) 75mA(150mA) 3,000V(2,500V / AC)
750mA(1.5A) 300V 750mA(1.5A) 300V
7.5A(15A) 30V 7.5A(15A) 30V
The stray capacitance between the collector terminal and the ground of the fixture is compensated by the hardware in the high voltage mode. Digital compensation is
Loop compensation
also available.
Maximum peak current Maximum peak voltage
High voltage mode2 ̶
400mA 10,000V
Maximum Maximum
Maximum Maximum peak current peak voltage Maximum Maximum
peak current peak voltage Maximum Maximum peak current peak voltage
High current mode peak current peak voltage 8,000A 60V
1,000A 40V ̶ 4,000A 60V
(pulse only) 400A 40V 4,000A 60V
400A 40V 400A 60V
40A 40V 400A 60V
40A 40V 40A 60V
40A 60V
The pulse width is variable in the range from 50µs to 400µs.
The pulse width is variable in the range from 50µs to 400µs.
Pulse width / (50µs to 1,200µs for 8kA range)
Measurement points can be specified ̶
measurement point Measurement points can be specified at 10µs/step.
(with a resolution of 10µs/step).
(50µs to 900µs for 4kA range)
Maximum data points 20 to 1,000 points can be specified per trace.
MEASUREMENT MODE REPEAT, STOP/SINGLE, SWEEP
Step generator
Current mode Amplitude range: 50nA to 200mA, 21 ranges, 1-2-5 step Maximum current: ± 2A / Offset: ±10 times STEP AMPLITUDE setting
Voltage mode Amplitude range: 50mV to 2V, 6 ranges, at 1-2-5 step Maximum voltage:±40V / Offset: ±10 times STEP AMPLITUDE setting
Staircase wave: 2times of 50Hz or 60Hz Staircase wave: 2times of 50Hz or 60Hz
(50Hz or 60Hz in the AC mode) Staircase wave: (50µs or 60Hz in the AC mode)
Step rate Pulse : The pulse changes in the range from 80ms to 1,000ms. 2times of 50Hz or 60Hz Pulse : The pulse changes in the range from 80ms to 1,000ms.
(The lowest frequency limited by the maximum peak power (50Hz or60 Hz in the AC mode) (The lowest frequency limited by the maximum peak power
consumption setting.) consumption setting.)
Pulse step The pulse width is variable in the range from 50µs to 400µs at 10µs resolution.
Number of steps 0 to 20steps
AUX output
Range OFF, -40 to +40V, variable with at 100mV resolution
Vertical axis
High voltage 1µA/div to 2 A/div, 20 renges, at 1-2-5 step
Collecto
100mA/div to 100 A/div, 100mA/div to 50 A/div, 100mA/div to 500A/div,
current High current ̶
10 ranges, at 1-2-5 step 9 ranges, at 1-2-5 step 12 ranges, at 1-2-5 step
Emitter current(LEAKAGE) 1nA/div - 2mA/div, 20 ranges, at 1-2-5 step
Horizontal axis
Collector High voltage 50mV/div to 500V/div, 13 ranges, at 1-2-5 step 50mV/div to 1,000 V/div, 14 ranges, at 1-2-5 step 50mV/div to 1,000V/div, 14 ranges, at 1-2-5 step
voltage High current 50mV/div to 5V/div, 7 ranges, at 1-2-5 step ̶ 50mV/div to 10V/div, 8 ranges, at 1-2-5 step
Base / emitter voltage 50mV/div to 5V/div, 7 ranges, at 1-2-5 step
Miscellaneous
Display 8.4-inch color TFT-LCD (SVGA 800 x 600 pixels)
Internal: Memory (setup: 256, REF waveform: 4)
Data save / recall
External: Removable storage connected to the USB port (setup, waveform save / recall, screen hard copy)
USB 1 port (USB1.1) Setup, Waveform Save/Recall, Hard copy of display (BMP, TIFF, PING)
Remote control Remote control by LAN: 1 port (100BASE-TX)
Power supply AC100V - AC240V, single phase, 50Hz/60Hz, Approx. 500VA AC100V - AC240V, single phase, 50Hz/60Hz
Mechanism section
424 (W) x 555.2 (L) x 221 (H)
424 (W) x 555.2 (L) x 354.5 (H) 1,110 (W) x 1,150 (L) x 1,216 (H)
Dimensions (mm) (without the external projection
(without the external projection portion) Dimensions (mm) (without the external projection portion)
portion)
Approx. 30kg (without optional
Weight Approx. 45kg (without optional accessories) Approx. 390kg
accessories)
9
Digital Oscilloscope
• 1M-point long memory & high-speed startup • Made in Japan • Superior cost performance
Features & New Functions
High-speed Startup Fitted with the First Fitted with Independent Channel
Waveforms can be measures a few seconds after Touch Screen of its Operation Keys and Knobs
switching on the power. Class Despite its compact size and narrow width, complex
Perform all operations directly function switching
1M point/CH Long Memory by touching the menu. The has been eradicated
Equipped with a long memory to enable waveforms to touch screen is made of to produce easy
be saved over long periods of time and to enable high- glass with superior levels of and comfortable
quality waveforms that maintain high-speed sampling to durability. operations.
be saved.
New Function Added: The new function will be provided in a free upgrade.
Waveform Mask Judgment Function Parameter Logging Function and Parameter Judgment Function
Pass/fail judgment with the waveform mask. (1) Parameter logging function and parameter judgment function.
(1) Mask judgment function Enables the parameter judgment results to be displayed as a list (a list of measurement
The quality of the waveform is evaluated based on the waveform set as the standard. results only can also be displayed.)
It is possible to display the measurement parameters at the same time as waveform
judgment.
(2) Data Saving Function
The judgment results can be saved onto a USB storage device (in the CSV format with
separation by comma.)
If the data is to be saved directly onto a USB storage device, insert the storage device
first of all and then save the data onto the USB memory.
New function
Judgment mode During parameter judgment During mask judgment
Judgment target: select one of four parameter types (A, B, C,D) select one among CH1 to CH4 (2CH machine: CH1 to CH2) and Math
Pass/Fail Comparison ranges: Large/small comparison, within range/outside range comparison All In or All Out for 1 to 4 areas
Mask creation: ̶ Horizontal or vertical direction, from among CH1 to CH4 (2CH machine: CH1 to CH2), Math, and REF1 to 5
Actions during Pass/Fail judgment Stop waveform capture/Save screen (USB memory)/Save waveform (USB memory)/Beep/Pulse output (when equipped with DS-578 option)
Logging items Time and parameter measurement results (conditions A, B, C, D), Pass/Fail judgment results
Logging When recording : Pop-up window, internal memory (up to 86400 entries)
Log output destinations
After recording : USB memory
11
Analog Oscilloscope
Analog Oscilloscope
DC - 470MHz 4ch Oscilloscope
SS-7847A
SS-7800A Series
DC - 400MHz 4ch Oscilloscope
SS-7840A
DC - 300MHz 4ch Oscilloscope
SS-7830A
Programmable Oscilloscope
Familiar operation response. SS-7840AP /
SS-7830AP
Origin of waveform
measurements.
Limitless gradation display.
Eternal standard unit.
SS-7847A
12
SS-7800A Series Specifications
Model SS-7847A SS-7840A SS-7830A
CRT CRT 6-inch rectangular, internal graticule (8 x 10 div, with scale illumination) - Japan made
Display
Accelerating voltage Approx. 20kV
Mode CH1, CH2, CH3, CH4, ADD, ALT, CHOP
2mVldiv -5Vldiv ̶ DC - 400MHz DC - 300MHz
Frequency
5mV/div -50mVldiv DC - 470MHz ̶ ̶
bandwidth
2mV, 100mVldiv -5V/div DC - 440MHz ̶ ̶
Less than 1.35 through Less than 1.35 through
VSWR
DC - 400MHz(with 50 Ω input) DC - 300MHz (with 50 Ω input)
Sensitivity(CH1, CH2) 2mV/div - 5 V/div 11-step (1-2-5), 2mV - 12.5V/div (with vernier)
Accuracy ± 2%
Bandwidth limiter 20MHz or 100MHz 20MHz
Vertical Rise time(Calculated from freq. bandwidth x rise time =0.35) 745ps at 20mV 875ps 1.17ns
deflection Signal delay Available
system
Input coupling AC, DC, GND(The cut-off freq. is 4Hz with AC coupl.)
Input RC: direct 1MΩ input :1MΩ ±1.5% // 16pF ± 2pF / 50 Ω input : 50 Ω ±1%
Max. input 1MΩ input : ±400Vm max. / 50 Ω input : 5V RMS
Probe sensor 1:1 , 1:10, 1:100 detection possible
Sensivity (CH3, CH4) 100mV/div, 500mV/div ± 3% (1MΩimput)
Input coupling (CH3, CH4) AC, DC
Offset voltage: variable axis range
±1V : 2mV/div - 50mV/div
Offset voltage variable range
±10V: 0.1mV/div -0.5 mVldiv
±100 V: 1V/div - 5V/div
Source CH1, CH2, CH3, CH4, LlNE
Coupling AC, DC, HF-REJ, LF-REJ
DC-10MHz 0.4 div
A triggering
10MHz - 100MHz 1.0 div
Level
100MHz - 300MHz ̶ 2.0 div
100MHz - 400MHz 2.0 div ̶
Triggering Source CH1, CH2, CH3, CH4
Coupling AC, DC, HF-REJ, LF-REJ
B triggering TV triggerung NTSC, PAL/SECAM, HDTV
Trigger mode TV-V (ODD, EVEN, BOTH) Iine number selectable, TV-H
TV clamp Back porch level
Count Setting range: 1 - 65535, Max. count freg. : 50MHz
Event trigger
Burst Time setting range: 0.1µs - 99.9s
X-axis CH1
Senstivity Same as CH1
X-Y Accuracy ± 2%
Bandwidth DC -2MHz
Y-axis Operating channel CH1, CH2, CH3, CH4, ADD
Horizontal display A, ALT, B, X-Y
Mode AUTO, NORM, SINGLE
Fastest range with mag. 500psec/div 1nsec/div
A sweep time
Slowest range 500msec/div
Fastest range with mag. 500psec/div 1nsec/div
Horizontal Slowest range 20msec/div
deflection
system B sweep time Accuracy A/B ± 2%
Triggered delay: CH1 , CH2, CH3, CH4
Delay
Continuous delay: RUNS AFTER
Delay jitters 1/20,000
Magnifier 10 times
Hold-off time Variable (up to sweep length or longer)
Auto setup V/H position, V/H range, trigger
Input channel CH1, CH2
Frequency response 50Hz -100MHz
CH2 signal output (50Ω) DC - 200MHz DC -100MHz
Z axis input 0.5Vp-p
Calibrator output Square-wave, 1kHz ±O.1%, 0.6Vp-p ±1%
Power supplv for probe Voltage: ± 12V, 2 FET or current probes connectable, Offset control available
Attenuator range, ADD UNCAL, AC/DC/GND, vertical mode, CH2 polarity A/B sweep range, x10 MAG, UNCAL,
CRT Read-out
horizontal display mode, hold-off trigger coupling, trigger source, trigger slope, TV-field, TV-line, TV-system
read-out
Cursor measurement ΔV(voltage measurement), Δt(time measurement), 1/Δt(division calculation by Δt)
Frequency counter 6-digit, ± 0.0025%
Frequency range 2Hz - 400MHz , reciprocal
Save and recall Up to 256-setup
Power off set-up Panel setting before switch is powered off
Back-up Battery back-up (approx. 30,000 hrs)
Power supply AC 100V - 240V, 50/60Hz, max.130VA
Dimensions and weight 320W x 160H x 420L (mm), approx. 8.5kg
Operating 0˚C - +40˚C, 90% RH (40˚C)
Environment conditions
Performance guaranteed +10˚C - +35˚C
Standard accessories Power cable (1), probe (2), fuse (2), panel cover (1), operation manual (1), accessory bag (1)
13
Isolation measurement system
DM-8000 main unit / DM-600 transceiver card DM-620 optical and metal DM-630 metal
High-speed DM-8000H Two isolation units can be transceiver card transceiver card
main unit connected per card. One isolation unit and one acquisition Two acquisition units can be
Up to 12 isolation units and acquisition unit can be connected per card. connected per card.
units can be connected. An acquisition
control card for capture control and
up to 6 specially designed transceiver
cards can be installed onto the main
unit. The gigabit Ethernet-enabled high- LAN cable
speed main unit (DM-8000) improves Control PC
(optional)
the waveform update speed when
using 3 or more units. The interlock
control terminal is on the rear panel.
LAN terminal
DM-610
External
acquisition control card trigger
Blank panel
This card controls waveform capture in terminal
measurement units. It also provides a
LAN
non-isolated external trigger input, which terminal
can be changed to an external trigger Interlock contact
output terminal.
The units are operated by a The units are operated by a The units can
built-in battery to perform built-in battery to perform continuously
floating measurements. floating measurements. operated with an
Frequency bandwidth: DC to 500MHz, The high resolution enables the AC power source.
highest sampling rate: 2GS/s, memory simultaneous measurement of These units are best
length: 500k points (DM-900), 16M switching waveforms and on-voltage. suited to the non-
points (DM-900L), input: 2channels (not Frequency bandwidth: DC to 500MHz, isolated measurement
isolated), interface: optical interface (set highest sampling rate: 2GS/s, memory of grounded power probes, for example.
of three interfaces) length: 500k points (DM-910), 16M Frequency bandwidth: DC to 500MHz, highest
points (DM-910L), input: 1channel, sampling rate: 2GS/s, memory length: 500k
interface: optical interface (set of three points (DM-400), 16M points (DM-400L), input:
interfaces) 2channels (not isolated), interface: electric
Insulation case Insulation case interface (one set)
Withstand voltage: 10kV Withstand voltage: 10kV
(Standard accessory) (Standard accessory)
Gate driving waveform of the U, V, and W phases View with zoom display.
on the high side of a 3-phase inverter.
15
Up to 24 CH at a high The many operation functions provided by the IS Viewer facilitate power
loss and other measurement.
voltage and wide
The Vce, Ic, output voltage and current
bandwidth can be Voltage waveform
waveforms of the upper and lower arms of
an inverter can be simultaneously measured.
simultaneously measured. Vce
Current waveform
dv/dt, di/dt, and other parameters, such as
power loss, can be easily calculated from
Ic the measurement waveforms.
Waveform monitoring and other system operations are remotely
performed using the standard IS Viewer (software). The IS Viewer Power loss waveform
can be used off-line as well, and is therefore useful for data Vce×Ic
organization at locations remote from the measurement site.
Time axis
Multi-channel floating measurements (simultaneous measurement example of the upper and lower arms of a 3-phase inverter)
Bandled IS Vewer software The waveform of voltage output from the 3-phase Differential probes were used for this type of
Optical fiber cable inverter that drives a motor or other device measurement in the past, but this resulted in
LAN cable (shown in the left-hand figure) is a pulse voltage the waveform sometimes being distorted, and
waveform, as shown in the figure below. it was sometimes difficult to ensure sufficient
measurement bandwidth due to constraints of
Average the common mode rejection ratio or withstand
waveform Several
common mode voltage. With optical fiber
dozen to
several isolation, this isolation system can accurately
thousand
volts monitor signals without being affected by these
Output
waveform constraints.
Upper
arm
Measuring Vge of the upper arm Measuring Vge of the upper arm
with differemtial input with isolation input
Motor
Lower
arm Three built-in
batteries
Oscilloscope
Remote
measurement
(up to 400m)
IGBT Gate voltage measurements in the high-side switch of a single phase inverter (one unit)
Isolation unit DM-900 Waveform capture can be more accurately
performed in comparison to the illustration
below (Oscilloscope + differential probe)
LAN
High-side
Controller PC (Option)
MOTOR
IGBT Vce voltage measurements in the high-side switch of single phase inverters (four units)
Isolation unit DM-900
LAN
Low-side
System configuration
Main unit DM-8000H 1
Acquisition control card DM-610 1
Transceiver card (optical x 2) DM-600 2
Isolation unit (500k points) DM-900 4
Optical fiber cable S DM-004 (5m) 4
IS viewer DM-800 1
Single phase inverter Controller PC (Option) 1
IGBT Vce voltage & Ic current measurements of 3-phase, 2-level inverters (twelve units)
Isolation unit DM-900
LAN
Controller PC (Option)
System configuration
Main unit DM-8000H 1
Acquisition control card DM-610 1
Transceiver card (optical x 2) DM-600 6
Isolation unit (500k points) DM-900 12
Optical fiber cable S DM-004 (5m) 12
Optical fiber cable S DM-004 (5m) IS viewer DM-800 1
Controller PC (Option) 1
17
Isolation System DM-8000 Specifications
DM-900L/DM-910L Isolation Unit and DM-400/L Acquisition Unit
Model DM-900 DM-900L DM-910 DM-910L DM-400 DM-400L
Signal input unit
Frequency Bandwidth (-3 dB) 500MHz
Bandwidth limiter 20MHz / 100MHz
Input impedance 1MΩ // 16pF 1MΩ // 16pF or 50 Ω
Maximum input voltage 400V max (DC+peakAC<=5kHz) CAT I
Number of channels 2 (between channels are not isolated) 1 2 (Not isolated)
Input coupling GND, DC1MΩ, AC1MΩ GND, DC1MΩ GND, DC1MΩ, AC1MΩ, DC50 Ω
CH1-MAIN: 50mV/div~5V/div, 1-2-5 steps
Input sensitivity 2mV/div~10V/div, 1-2-5 steps 2mV/div~10V/div, 1-2-5 steps
CH2-ZOOM: 2mV/div~1V/div, 1-2-5 steps
CH1-MAIN: 50mV/div~500mV/div, ± 10V * 2
2mV/div~50mV/div, ± 1V * 1 2mV/div~50mV/div, ± 1V * 1
1V/div~5V/div, ± 100V * 3
Offset range 100mV/div~500mV/div, ± 10V * 2 100mV/div~500mV/div, ± 10V * 2
CH2-ZOOM: 2mV/div~20mV/div, ± 2V * 1
1V/div~10V/div, ± 100V * 3 1V/div~10V/div, ± 100V * 3
50mV/div~1V/div, ± 20V * 2
Offset accuracy ± (1.0% + 0.5% of full-scale + X) X:* 1mV, * 10mV, * 100mV
1 2 3
Compact,
Example of the 8CH model monitor display
* The LCD monitor is equipped separately.
* Contact us for the specifications of the operation panel (option.)
power-saving,
multi-channel,
high-speed waveform updates
Optimized by enabling more than one
oscilloscope to be used simultaneously and
incorporating adjustment lines and functions.
• Compact, energy-saving specifications (power consumption: 30VA or less) achieved
through digital processing (one-tenth of our conventional models)
• Multi-channel and multi-monitor functions (the signals for two independent channels can
be displayed on a maximum of four windows) 2CH Model with built-in type LCD
* Contact us for the specifications of the operation panel (option.)
• High-speed waveform updates (maximum of 100,000 times per second)
• Gradation displays similar to analog oscilloscopes
19
Passive Probes (100:1, 10:1, 1:1)
Oscilloscope
Model Attenuation Cable length Input RC Bandwidth input Conforming models
capacity
DS-5532/5534/5552/5554,
DS-5332/5334/5352/5354,
SS-101R 10:1 Approx. 1.2 m 10MΩ, approx. 12pF DC to 500MHz 13pF to 23pF
TS-8500/P, SS-7840/A/H/P, SS-7830,
SS-7825/P, TS-81000/80600, SS-7847A
SS-103R 10:1 Approx. 1.2 m 10MΩ, approx. 15pF DC to 200MHz, ± 3dB 16pF to 24pF SS-7821/A
10:1 10MΩ, approx. 22pF ± 2pF DC to 60MHz, ± 3dB 20pF to 45pF
SS-0110 Approx. 1.5 m SS-7804/P/7802, DS-8706/8701
1:1 1MΩ, 200pF or less DC to 6MHz, ± 3dB −
10:1 10MΩ, approx. 14pF DC to 100 MHz, ± 2 dB 18pF to 35pF DS-8606/C, DS-8608A/8607A,
SS-0120 Approx. 1.5 m DS-8608/8607, DS-8710,
1:1 1MΩ, 150pF or less DC to 6MHz, ± 3dB − SS-6123A/6613, SS-6611/6122A
10:1 10MΩ, approx. 16pF DC to 100MHz, ± 3dB 18pF to 35pF
SS-0121 Approx. 2 m SS-3510, SL-232
1:1 1MΩ, 170pF or less DC to 3MHz, ± 3dB −
10:1 10MΩ, approx. 14pF DC to 100MHz 10pF to 32pF DS-5110/DS-5106/DS-5110A/DS-5106A
SS-0122 Approx. 1.5 m
1:1 1MΩ, 150pF or less DC to 6MHz − DS-5110B/DS-5106B
10:1 10MΩ, approx. 22pF DC to 60MHz 10pF to 45pF DS-5104/DS-5102/DS-5104A/DS-5102A
SS-0112 Approx. 1.5 m
1:1 1MΩ, 200pF or less DC to 6MHz − DS-5104B/DS-5102B
DS-5512/5514/5522/5524,
10MΩ, approx. DS-5312/5314/5322/5324,
SS-0130R 10:1 Approx. 1.5 m DC to 100MHz, ± 2dB 18pF to 35pF
12.5pF ± 2pF SS-7811/A/7810/A/7806, DS-8617,
DS-9121/9122, DS-8812/8814
SS-0004 1:1 Approx. 1.1 m 44pF ± 6pF DC to 30MHz, ± 3dB (For probes only) All models with BNC for input
Maximum input voltage
6,000 V CATⅠ(DC+ACpeak)
SS-0160R 100:1 Approx. 2 m 66.7MΩ± 1 %//3pF or less DC to 400 MHz 6pF to 18pF
1,000 V CATⅡ(DC+ACpeak)
4,000 V CATⅠ(DC+ACpeak)
SS-0161R 100:1 Approx. 2 m 66.7MΩ± 1 %//3pF or less DC to 400 MHz 6pF to 18pF
1,000 V CATⅡ(DC+ACpeak)
• Connector: BNC
• Maximum input voltage: 600 V (DC + AC peak); 10: 1 probe, 600 V (DC + AC peak); 1: 1 probe
BP-75M1 DC to 3GHz 75 Ω 0.5W (Ave.), 500W (Peak) SFP-4A 10:1 Approx. 2.15pF、Approx. 1MΩ DC to 800MHz
Termination SS-220
BB-50M1 DC to 1GHz 50 Ω 0.5W BNC(Ave.)
(Attenuator) 100:1 Approx. 1.9pF、Approx. 900kΩ DC to 1GHz
BB-50M10 DC to 300MHz 50 Ω 5W BNC(Ave.) Custom Order
Signal T S-50S2 DC to 18GHz 50 Ω 1.25W SMA
50 Ω (Plug)/
Conversion pad B-5P7J1 DC to 2GHz
75 Ω (Jack)
0.5W BNC(Ave.)
Mini Clips
Mini clip Test clip Probing arm
HP-2 PB Series T-60
0.8 mm to 2.54 mm 0.08 mm to 0.23 mm Extremely useful when used with Mini clips.
Pipe length: 30 mm Pipe length: XX mm Can be used with
10 colors (10 sets) most probes.
20
Optional probes for the isolation system
PHV1000-RO PHV6xx-LRO
POWER supply
Scope Wagons MT-600
PS-26 DS-579 [DS5500 series only]
for SS-250/SS-240A/ for SS-250/SS-240A/
SS-270/SS-260 SS-270/SS-260
(Input voltage
AC100V/120V/200V/240V)
21
Digital Multimeters
VOAC 7522H
10A for 10A range (FUSE 15A)
DC Component on input current must be included in the Max. input current.
In the case of 10A range at 45Hz to 1kHz, 0.3 must be added to %.
4-terminal resistance measurement In the case of DC+ACA, 500 (less than 45Hz) or 300 (45Hz or higher) must be added to the value of Accuracy in above.
dual function 1µV, 509999, 5½ digits Sample rate of FAST becomes the same value as MID (approx. 20 times/sec).
22
13. General
Moving Average, Scale, Decibel (dBm, dBµ), Difference, Statistics (MAX, MIN, X, s), Operation Temperature and Humidity 0˚C to +50˚C (less than 80%RH) no condensation, 70%RH or less at +40˚C to +50˚C
MATH -20˚C to +60˚C (70%RH or less)
Comparison (COMP), Arithmetic Calculation between Dual Function Storage Temperature and Humidity
DATA Max. 3000 data with 10 msec resolution time mark (Elapsed time) no condensation, includes operation temperature
Memory Measurement 210W x 99H x 353L mm (Options are built into the main unit)
SET UP 10 Size
Interfaces Standard RS-232 Weight 3.5kg (includes options) or less
(Full Remote) Option LAN, GPIB Standard Accessories Fuse, Test Leads, Alignment Screwdriver, Operation Manual(CD-ROM), Power cable
Voltage AC100V, 110V, 220V, 240V
Power Supply Frequency 50Hz, 60Hz
Power Consumption 21 VA (includes options) or less
Options
Product Name Part Number Image of Product Product Name Part Number Image of Product
LAN interface * 1
SC-351 SC-351 or SC-353
Banana plug (Can be used to connect
POMONA1286
2
a thermocouple)
DIO interface * SC-352
RS232-USB Converter
SC-525
(WindowsXP,Vista,7)
Test leads SC-020
Alligator clip
SC-022
For SC-020 (AC30V/DC60V/DC10A)
High-voltage probe
30kVdc max. (can be used only in the SC-003
Zin of 10MW range) Alligator clip H
SC-023
For SC-020 (600Vrms, CAT II/10A)
*1 The LAN interface SC-351 and GPIB interface SC-353 cannot be installed at the same time.
*2 The DIO interface SC-352 and D/A Converter interface SC-354 cannot be installed at the same time.
Clamp-on current probe
DC ± 200A MAX AC150A rms MAX SC-011
(40Hz to 500Hz) Digital Multimeters (Handy type)
1µV, 50000, 100µV, 9999,
4½ digits 4-digit at full scale
Sheath-type thermocouple (Type K)
SC-0107
VOAC 22 VOAC 87
-200˚C to +800˚C
23
Universal Counter
[Option]
230MHz x 2ch
Universal Counter
SC-7205H
Useful functions based on the need for a maximum of 3GHz and easy use.
• Enables frequency measurements for two independent channels • Full lineup of options to provide greater expandability
(SC-7207H, SC-7205H.) • Comparator output (open collector) with digital I/O (SC-702.) External
• Pulse width measurements and time interval measurements greatly trigger input.
broaden the scope of single-gate measurement. * 150mA can be used for line monitoring equipment without modification to provide a margin of 50V.
• Easy operations with single key strokes for each action. • The high-stability standard oscilloscope (SC-703A) provides highly
• Easy-to-see fluorescent display area. Detailed information displayed accurate measurements.
with 5 x 7 dot resolution.
* A full-spelling guide provides powerful support for operations.
• Auto-trigger function that eradicates the need for setting the trigger
level. Manual setup is, of course, also possible.
• Making line inspection tasks more efficient is a simple chore with the
comparison and statistic calculation functions. Specifications and Performance
• The scaling calculation function enables single unit conversion RS-232: Fitted as standard.
(revolutions, speed, etc.) Output Interfaces GPIB Fitted as standard (optional for the SC-7205H: SC-701)
• Input signal peak voltage measurements make it easy to confirm the Digital I/O: Optional (SC-702)
waveform amplitude. Approximately 210W x 99H x 353L mm (excluding options and
• The save/recall function for panel setup makes predetermined Size and Weight
protrusions)
inspection tasks more efficient. 4.0kg or less (when mounted with the SC-701, 702 and 703
options)
• The GPIB (optional for the SC-7205H: SC-701) and RS-232 interfaces High-stability Standard Two types of options available (only one type may be mounted)
provide full remote control. Oscillator (manufactured Temperature Characteristics: +/-0.05ppm, Oscillation Frequency:
* Transmission is performed in the real-time at a high speed of a maximum 200 items of data/second, which
on request) 10MHz
contributes to improved line throughput.
24
Universal Counter Option Universal Counters SC-7207H / SC-7206H / SC-7205H Specifications
Frequency A (FREQ-A)
GPIB Interface •Measuring range and resolution * SC-7206H is not equipped with EXT-B gate
Reference time
SC-7207H
10ns
SC-7205H
100ns
SGL gate 10ns to 10,955s 100ns to 109,951s
New Crystal (SC-703A) Measuring range
Internal gate (1ms to 10s) 10ns to approx. 1/2 gate time 100ns to approx. 1/2 gate time
Oscillation Frequency 10MHz SGL gate 10ns to 10µs 100ns to 100µs
Temperature +/-0.05ppm Average 1 to 24 10ns 100ns
Characteristics Range of 0 ˚ C to 40 ˚ C with +25 ˚ C as the standard. Measuring count of 25 to 2,499 1ns 10ns
resolution internal 2,500 to 249,999 100ps 1ns
+/-0.05ppm gate 250,000 to 24,999,999 10ps 100ps
Rising Time 10 minutes for power switch-on with the frequency 1 25,000,000 or more 1ps 10ps
hour after power switch-on as the standard
+/-0.02ppm
Time Fluctuations (per
Value at 72 hours after power switch-on with
day)
48 hours after power switch-on as the standard
+/-0.02ppm
Time Fluctuations (per
Value at one year after power switch-on with
year)
10 days after power switch-on as the standard
25
Frequency ratio A/B (FREQ A/B) (for SC-7207H and SC-7205H only)
•Measuring range and resolution
SC-7207H SC-7205H
Input signal frequency range Both CH-A and CH-B are the same as that for FREQ-A
Measuring range Internal gate (1ms to 10s) 1E-9 to 1E+9
Measuring resolution Internal gate (1ms to 10s) 1+LOG (CH-A input frequency x gate time) digits
Phase measuring A --> B (PHAS A --> B) (for SC-7207H and SC-7205H only)
•Minimum time interval: 6ns •Maximum repetitive frequency: 80MHz •Measuring range and resolution
SC-7207H SC-7205H
Reference time 10ns 100ns
SGL gate 0.1µ to 359.999,999,9 [˚]
Measuring range
Internal gate 1µ to 359.999,999 [˚] 10µ to 359.999,99 [˚]
SGL gate 0ns/input period x 360 [˚] 100ns/input period x 360 [˚]
1 to 24 10ns/average input period x 360 [˚] 100ns/average input period x 360 [˚]
Measuring Average count of 25 to 2,499 1ns/average input period x 360 [˚] 10ns/average input period x 360 [˚]
resolution internal gate 2,500 to 249,999 100ps/average input period x 360 [˚] 1ns/average input period x 360 [˚]
250,000 to 24,999,999 10ps/average input period x 360 [˚] 100ps/average input period x 360 [˚]
25,000,000 or more 1ps/average input period x 360 [˚] 10ps/average input period x 360 [˚]
Peak voltage measuring (SC-7206H is not equipped with CH-B)
Measures and displays in real-time the voltage amplitude of the measured signal at CH-A or CH-B.
Frequency range 150Hz ≦ input frequency ≦ 50MHz
Response time 2 seconds or less
Voltage range ± 2.50V (ATT off, resolution: 10mV), ± 50.0V (ATT on, resolution: 100mV)
Measuring error ATT off: 10% of indication ± 50mV ATT on: not specified
CH-A, CH-B input terminal (SC-7206H is not equipped with CH-B)
Input RC Approx. 1MΩ//20pF or less
Coupling AC or DC
Low pass filter Off, 10kHz
Attenuator Off, 26dB (1/20)
ATT off -2.50V to +2.50V (resolution: 10mV)
Measuring Range
ATT on -50.0V to +50.0V (resolution: 100mV)
Trigger level
accuracy ATT off 10% ± 30mV of the set value (± 3% when +2V to -2 V )
(0˚C to +40˚C) ATT on 10% ± 300mV of the set value (± 3% when +40V to -40 V )
ATT off ± 2.5V
Operating input voltage range
ATT on ± 50V
ATT off 30mVrms (DC to 230MHz)
Manual trigger
ATT on 0.6Vrms (DC to 230MHz)
Input sensitivity
ATT off 200mVrms (10kHz to 230MHz, sine wave)
Auto trigger
ATT on 4Vrms (10kHz to 230MHz, sine wave)
CH-C input terminal (for SC-7207H and SC-7206H only)
Maximum input power +30dBm (approx. 7Vrms when 1mΩ/50 Ω = 0dBm as a reference)
Impedance Approx. 50 Ω
Coupling AC
VSWR 2.0 or less (SC-7207H: 100MHz to 3GHz, SC-7206H: 100MHz to 2GHz)
Input sensitivity (Sine wave: up to 2 GHz for SC-7206H)
-20dBm (100MHz ≦ input frequency ≦ 300MHz)
AGC off/on -25dBm (300MHz < input frequency ≦ 1.5GHz)
-20dBm (1.5GHz < input frequency ≦ 3.0GHz)
SC-7207H SC-7206H
Detection frequency range
100MHz to 3GHz 100MHz to 2GHz
Input sensitivity (Sine wave: up to 2GHz for SC-7206H)
Burst detection
-20dBm (100MHz ≦ input frequency ≦ 1.2GHz)
AGC off
-10dBm (1.2GHz < input frequency ≦ 3.0GHz)
Detection delay time 500µs (Burst period ≧ set gate + 500µs)
10MHz STD IN
BNC terminal for more stable input of the external reference frequency
Frequency 10MHz± 50Hz (± 5ppm)
Amplitude 1Vrms to 5Vrms, threshold = 0V
Input resistance Approx. 6.4kΩ
Input coupling AC
10MHz STD OUT/(MARKER OUT)
BNC terminal for output of internal reference oscillator or marker signal.
Marker signal is a signal that presupposes the brightness modulation (Z axis) of the analog oscilloscope for example. It is enabled at the SGL gate when the function is in between the time interval (T.INT A --> B) and phase (PHAS A --> B). Output is
"Lo level" from the start of CH-A measuring to the start of CH-B measuring.
Output CMOS level
Reference frequency output 10MHz: Stability is the same as that for the internal reference oscillator.
Marker output In the 5MHz band, L-state is output during actual measuring. (for SC-7207H and SC-7205H only.)
Output interface Environmental conditions
•RS-232 is equipped as standard •GPIB is equipped as standard (option SC-701 for SC-7205H) •Warm-up time: 60 minutes or more •Operating temperature/humidity: 0˚C to +40˚C/85%R.H or less (no condensation)
•Digital I/O option can be installed (SC-702) •Storage temperature/humidity: -20˚C to +60˚C/90%R.H or less (no condensation)
Reference oscillator
Equipped with SC-7207H, SC-7206H and SC-7205H as standard
Output is possible to the 10MHz OUT BNC terminal on the rear panel of the main unit.
•Oscillation frequency: 10MHz •Temperature characteristics: ± 2.5ppm/unit environmental temperature: 0˚C to +40˚C •Aging rate: ± 1.0ppm/year
Power supply conditions and power supply voltage changes (factory option)
•Voltage: AC100V / 110V to 120V / 220V to 240V •Frequency: 50Hz, 60Hz, 400Hz
•Power consumption: At AC100V with optional SC-701 and SC-702 are installed.
SC-7207H SC-7206H SC-7205H
Power Consumption 36VA MAX 33VA MAX 31VA MAX
Size (210 ± 2)W x (99 ± 2)H x (353 ± 2)L mm (excluding options and protruded parts)
Weight 4.0kg or less (including optional SC-701 and SC-702)
Accessory Power cable (1), operation manual CD-ROM (1)
26
Universal Counter
A Maximum of 3GHz, and the Digit Display
SC-7217
Greatly Increased to Accommodate a
Maximum of 12Digits/sec
[Option]
• USB, LAN, RS-232 (option) and full remote control with GPIB (option)
• Comparate output with digital I/O
• Full lineup of options to provide greater expandability
- Data stored on USB storage memories.
- High-stability clock oscillator option.
SC-7217 Interim Specifications
Input impedance 50 Ω ± 1.5% / 1MΩ± 1.5% //16pF ± 3pF
Input withstand pressure 50 Ω/ 1MΩ 7Vrms / 200Vpk
Frequency band DC / AC DC to 450MHz / 10Hz to 450MHz
Input voltage range ATT OFF / ON ± 2.5V / ± 50V
CH-A、CH-B
Trigger level accuracy ATT OFF / ON ± 2%± 25mV / ± 2.5%± 500mV
Slope switching +/−
Band limitter 10kHz
Noise rejection OFF/ON
EXT-B Input signal range Pulse width / frequency 500ns min / 1MHz max
Input impedance / SWR / Maximum input electrical power 50 Ω, AC coupling / 2.0 or less / +30dBm
Frequency band 100MHz to 3GHz
AGC ON/OFF
CH-C
Burst detection ON/OFF
Detection sensitivity Up until 1.2GHz: -20dBm, up until 3GHz: -10dBm
Burst detection delay time 10µs
FREQ A、FREQ B Max. 13-digit, 12-digit/sec (at 1second gate)
Measurement range Single: 6mHz to 250MHz, time / EXT-B gate: 12mHz to 450MHz
Gate selection Single / EXT-B / Time (set at 10µs to 10s 10ˆn) (n: integer)
FREQ C Max. 13-digit, 12-digit/sec (at 1second gate)
Measurement range 100MHz to 3GHz, 1/16 pre-scaler
Gate selection EXT-B / Time (set at 10µs to 10s 10ˆn) (n: integer)
FREQ LINE Measurement range / Gate selection 45Hz to 440Hz / 0.1s/1s/10s
Single: 4ns to 166s
Measurement range
PERIOD A Time / EXT-B gate: 2.2ns to 83s
Gate selection Single / EXT-B / Time (set at 10µs to 10s 10ˆn) (n: integer)
Input signal range Pulse width / Frequency 6ns min / 80MHz max
DUTY A Measurement range Single / Time 0.01µ to 99.999,999,99% / 0.2µ to 99.999,999,8%
Gate selection Single / Time (set at 10µs to 10s 10ˆn) (n: integer)
Input signal range Pulse width / Frequency 6ns min / 80MHz max
Measurement PULSE WIDTH A Measurement range Single / Time 6ns to 171s / 6ns to approximately ½ gate time
Functions Gate selection Single / Time (set at 10µs to 10s 10ˆn) (n: integer)
Input signal range Pulse width / Frequency 6ns min / 80MHz max
TIME INTERVAL A→B Measurement range Single / Time 6ns to 10,995s / 6ns to approximately ½ gate time
Gate selection Single / Time (set at 10µs to 10s 10ˆn) (n: integer)
Input signal range, Frequency 250MHz max
FREQ A/B
Measurement range / Gate Selection 1 E-9 to 1 E+9 / Time (set at 10µs to 10s 10ˆn) (n: integer)
Input signal range Pulse width / Frequency 6ns min / 80MHz max
0.1µ to 359.999,999,9˚/ 1µ to 359.999,999˚ (However, it is necessary or this to be less than half of the gate for non-
PHAS A→B Measurement range Single / Time
measurable signal cycles)
Gate selection Single / Time (set at 10µs to 10s 10ˆn) (n: integer)
Input signal range Pulse width / Frequency 2ns min / 250MHz max
TOT A Gate selection MANUAL / EXT-B / Time (set at 10µs to 10s 10ˆn) (n: integer)
Measurement range 0 to 4,294,967,295 count
Peak voltage Measurement frequency / Measurement speed 150Hz to 150MHz / 2 seconds or less
measurement Measurement voltage range ATT OFF / ATT ON ± 2.5V / ± 50V
Measurement operations Repeat / Single / HOLD
Calculation Smoothing (moving average), scaling, comparate, statistics (MAX, MIN, σ, average)
Pulse setup Internal memory (10) or USB memory
DATA save memory MAX. 500,000kinds (volatile memory)
Internal Temperature characteristics +/- 1ppm (range of 0 to +40˚C with +25˚C as the standard)
standard clock Temporal change / Short-term stability ± 0.1ppm/month、± 1ppm/year / ± 1ppb/s
Interface USB / LAN / DIO USB2.0 HS / 100base-TX / Output: HI/LO/GO/BUSY
10MHz STD IN Input impedance / Input frequency / Input sensitivity Approximately 850 Ωs (at 10MHz), AC coupling / 10MHz +/- 50Hz / 100mVrms
Marker / STD output STD / Marker selected and output with the setting
Output impedance / Marker output / STD output 50 Ωs +/- 10% / +1Vo-p (0V output during measurement) / 10 MHz sine wave 1Vp-p or more (with 50 Ωs at the terminal)
Temperature characteristics +/- 20ppb (range of 0 to +40˚C with +25˚C as the standard)
+/- 10ppb/day (fluctuations in one day ’s frequencies with the standard frequency being that measured after 48 hours.
Medium stability At +25˚C)
Temporal change
+/- 100ppb/year (fluctuations in one year ’s frequencies with the standard frequency being that measured 10 days after
Options the power has been switched on. At +25˚C)
OCXO
(OP when Temperature characteristics +/- 5ppb (range of 0 to +40˚C with +25˚C as the standard)
shipped) +/- 0.5ppb/day (fluctuations in one day ’s frequencies with the standard frequency being that measured 30 days after
High stability the power has been switched on. At +25˚C)
Temporal change
+/- 50ppb/year (fluctuations in one year ’s frequencies with the standard frequency being that measured 30 days after
the power has been switched on. At +25 ˚C)
Interface GPIB (conforming to IEEE488-1 with full remote functions,) RS-232C, host for connecting the USB memory (for storage only)
Voltage / Frequency AC 100V to AC 240V ± 10% / 50 to 60Hz± 5%(100V to 240V) / 400Hz± 10%(100V to 120V)
Electric power
Power consumption 70VA(35W) max
External dimensions (W x H x D) (210 ± 2)×(99 ± 2)×(353 ± 2) mm
Accessories Product users’guide x 1, instructions (CD) x 1, power cable x 1.
Environment 0˚C to +40˚C with 80%RH or less and no condensation
27
Function Generator
Function Generator
SG-4100 Series
• Wide oscillation bandwidth from 10mHz to 15MHz (SG-4105) PMC function*(Factory option)
• High accuracy (50ppm: SG-4105, SG-4104) and high Pulse motor control function SG-506 (SG-4105)
definition waveform output by employing DDS (Direct Digital
Pulse motor control function
Synthsizer) system PMC option function controls pulse motor. Pulse motor acceleration or
braking controls need to be reviewed not only by position control, but also
• Max 20Vp-p (Output terminal open) (SG-4105) under loaded condition. The PMC option simplifies the evaluation.
• 0.0% ∼ 100.0% duty control/ Up to 65,536 Burst Pulse outputs in open collector (50V) are output from rear panel with PMC
option.
waveforms Common motor driver circuit connected with PMC.
• Offset control +10V ∼ -10V (output terminal open) *PMC (Pulse Motor Control) is coined word by IWATSU TEST INSTRUMENT
• Waveform outputs are connected continuously when vary CORPORATION.
(Order any factory options when ordering the main unit. Additional orders
the frequency after the delivery of the main unit require a separate fee.)
• Linear / Log sweep function Upper waveform shows
drive pulse for pulse motor,
• Simultaneous display of the frequency and output voltage lower waveform shows
• Easy operation (set performance can be checked at a sensor input waveform.
After reaching maximum
glance) frequency while specified
• PMC option (SG-506: SG-4105) best suited for evaluating accelerating period, starts
braking by sensor input
pulse motor control signal. Then stops at
• Provides Small-amplitude on Large-offset specified pulse counts.
SG-300 Specifications
Maximum Voltage 24Vp-p (with 50 Ω loads) / 48Vp-p (without any load)
DC or Peak 240mA (with 50 Ω loads) / Continuous
Maximum Current
DC or Peak 300mA (with Lo Ω output)
Full Power Band 1MHz (with a 50 Ω load and 24Vp-p output)
28
SG-4100 Series Specifications
Model SG-4105 SG-4104
Output waveform Sine wave, square wave, pulse wave, triangle wave, ramp wave, DC output
Output channels 1
Output impedance 50 Ω fixed
Sine, square 10mHz-15MHz 10mHz-5MHz
Pulse 10mHz-100kHz(without DC)
Frequency Others 10mHz-100kHz (without DC)
Accuracy ± 50ppm
Resolution 10mHz or 5 digits
50mVp-p to 10Vp-p (50 Ω)
Range
100mVp-p to 20Vp-p (open)
Accuracy (sine 1kHz) ± 1%
Except for DC waveform output : 0.1mV or 3 digits(50.0mV to 10.0V)
Resolution
For DC waveform output : 1mV or 3digits(1mV to 5.00V)
Amplitude Sine: up to 100kHz ± 1% ± 2%
Over 100kHz-1MHz ± 2% ± 3%
Flatness(reference to 1kHz) Over 1MHz ± 3% ± 5%
Square: up to 100kHz ± 3%, over 100kHz ± 5%
Triangle, pulse: ± 3% SLOW mode (all waveforms)
Mode CONT, TRIG, GATE
Range ± 5V (waveform + DC offset less than 5.025V)
Offset Resolution 1mV or 3digits
Accuracy ± 1% setting value ± 5mV (at DC output)
Square wave 40-60% (more than 5MHz) 20-80% (5MHz or less) 20-80%
Duty
Others 0-100% (pulse wave, ramp wave)
Up to 100kHz -50dBc
Harmonic distortion * Over 100kHz-1MHz -45dBc
Over 1MHz-15MHz -35dBc (SG-4104: up to 5MHz)
Sine wave spectral purity 100kHz-1MHz -60dBc
*Amplitude at 10Vp-p Spurious * 1MHz-10MHz -50dBc
10MHz-15MHz -40dBc (SG-4104: up to 5MHz)
0.10% at 1Vp-p or more, less than 100kHz
Total harmonic distortion
0.30% at less than 1Vp-p, 100kHz
Square 2% (less than 1MHz)
Step response Overshoot Pulse 2% (1µs or more FWHM *)
*Full Width at Half Maximum
Square 20ns or less 35ns or less
Rise, Fall time (10%-90%)
Pulse 300ns or less
Curve Linear/Log
CONTINUOUS: Oscillation continues at STOP frequency
TYPE
STOP: Oscillation stops after STOP frequency
SWEEP ̶
Mode CONT, GATE, TRIG
SWEEP TIME 1ms-500s
Sync out SWEEP SYNC, SWEEP MARKER
Number 65536
BURST CONT, TRIG selectable ̶
Mode
ON counts or OFF counts
Range ± 359.9˚
PHASE
Resolution 0.1˚
Oscillation frequency 10mHz-100kHz
Waveform Pulse
Control CW(one-way control)
Output Open collector 1 output
Pulse motor modulation Sensor input IN1, IN2
(available only when PMC option is LIN-A,: After acceleration, braking by sensor input ̶
installed) BG-506 Mode LIN-B: After acceleration, braking by specified pulse
counts
Acceleration, braking curve Linear
Pulse counts 16777216
Acceleration, braking time 1ms-45s
Level, polarity TTL level (H: 2.1V min., L: 0.9V max.)
Inputs 1
Input impedance 1kΩ or more
TRIG
Minimum pulse width 100ns
Square: 5% of period +350ns or less
TRIG delay Normal mode
Pulse: Period/16384 + 800ns or less
Setup memory 9
Remote control GPIB, RS-232 ̶
AC100V± 10%
Voltage
AC110V, 220V, 240V (factory option)
Power
Frequency 50Hz, 60Hz, 400Hz
Consumption Approx. 55VA
Dimensions Approx. 210W x 99H x 353L mm
Weight Approx. 4kg
Storage -20˚C to +60˚C/90%R.H. or less
Environment conditions
Operating 0˚C to +40˚C/85%R.H. or less
Warm up time 30 min. or more
Accessories Power cable (1), operation manual (1)
Factory option PMC: SG-506 ̶
* Waveform selection and frequency for CH1 and CH2 are the same.
SWEEP, modulation and BANK functions are disabled.
29
Delay Pattern Generator
Setting parameters and output examples of 6 channel Signal generation method and output examples of the
independent pulse output inverter option
Tracking function
The pulse width, delay time, and other settings can be changed simultaneously for
any combination of CH. Output example when the pulse width of channels 1 to 3 is
changed simultaneously.
3-phase 2-level in the INVERTER mode
Pulses can be easily generated by specifying the carrier frequency (Fc), modulation
signal frequency (Fm), and modulation period (that is, the rate of the modulation signal
Li ne up amplitude to the carrier amplitude).
30
Gap control to prevent the high and low side switches of devices from Easy generation of PWM signals
being turned on simultaneously
The inverter and PPG option (DG-801) enables you to output control signals for the
buck chopper, single-phase uni-polar, single-phase bi-polar, and 3-phase 2-level. The
modulation frequency and modulation depth can be changed even during oscillation.
U phase This is convenient for testing inverters because it is possible to obtain output to which
pulse width modulation created from the inner sine wave and triangle wave is applied.
X phase Note #1:
The modulation signal
is shown only for
SYNC explanatory purposes.
V phase This signal is not output
Y phase U phase
from the
DG-8000.
Short circuits are
When using the
dangerous
V phase PPG function, this
generator functions
as a signal generator
Pseudo signal of the for complicated logic
If the phase U and X devices in the above illustration are turned on at the same time, modulation wave modulation waves
(Note #1) on 6 channels using
they short-circuit, causing danger and damage. predetermined pulse
The DG-8000 gap time control function automatically generates the specified dead patterns. Waveform
time as shown in the illustration. Even if the frequency or cycle changes, the dead patterns can be created
Configuration example
using the waveform
time remains constant. The gap time can be changed even during oscillation. It is also DG-8000 main unit: 1 creation application
possible to turn devices on at the same time by specifying a negative value. DG-801 inverter and PPG option: 1 (which is available free
of charge.)
Independent control of the time axis and vertical axis Variable control of the PWM signal frequency
The operation pattern option (DG-802) is convenient for continuous operation testing
SYNC SYNC because it enables variable control of the frequency and modulation depth (in the
inverter mode only). The patterns for such control are controlled using predetermined
CH1 CH1 arbitrary waveforms. These waveforms can be created using the waveform creation
application (which is available free of charge.)
CH2 CH2 The illustration on the
left shows an example
SYNC of when a trapezoid
CH3 CH3 waveform signal is
used to apply frequency
U phase modulation.
Application example: Continuous operation test of solenoid and other elements that control electromagnetic valves
Conventional device Device configuration example using The external modulation option (DG-601) enables external
configuration example the DG-8000
control of the following functions:
Feedbeck
- Modulation of the pulse width and delay in the basic mode
- Control of the modulation depth in the inverter mode
Control PC - Control of the frequency and modulation depth for operation
Control interface patterns
Feedbeck Feedbeck Feedbeck
Configuration example
DG-8000 main unit: 1
PWN Signal PWN Signal PWN Signal PWN Signal PWN Signal PWN Signal DG-802 operation pattern option: 1
Driver Current Driver Current Driver Current
Driver Driver
Driver
& SW detection & SW detection & SW detection
& SW
Current
detection & SW
Current
detection & SW
Current
detection DG-601 external modulation options
Solenoid Solenoid Solenoid
valve coil valve coil valve coil Solenoid Solenoid Solenoid
valve coil valve coil valve coil
32
B-H Analyzer
Main features
• Wide measurement frequency for materials analysis which used in high frequencies
SY-8218: SINE from 10Hz to 10MHz, Pulse at Duty 50:50 from 10Hz to 1MHz
SY-8219: SINE from 10Hz to 1MHz, Pulse at Duty 50:50 from 10Hz to 1MHz
• 16times of acquisition data(comparing with current Iwatsu models)
Acquisition data at 8,192points/cycle perform precise measurement on parameters such as
Hc(Coersive force), Br(Residual flux density), and other parameters.
• Pulse excitation function
Both SINE(Sinusoidal) and Pulse(at Duty 50:50, 1MHz,max. ) excitation are available as a
standard function
• Temperature characteristic test with Scanner Chamber System
• Optional Items
Power Amplifiers
DC bias power supply*
Single plate measurement function*
High-current POD*
*under development 33
SY-8200 Series Specifications
Model SY-8218 SY-8219
Measurement method CROSS-POWER method (conformance to IEC62044-3)
Measurement mode B-H measurement, Pc measurement, µ measurement
Characteristics value
B-H measurement: Max. magnetic flux density (Bm), residual magnetic flux density (Br), max. magnetic field (Hm), coercive force (Hc), squareness ratio
(Br/Bm), amplitude permeability (µa), core loss (Pc, Pcv, Pcm), current/voltage phase (Θ), total magnetic flux change (2Øm)
Measurement item Pc measurement: Max. magnetic flux density (Bm), residual magnetic flux density (Br), max. magnetic field (Hm), coercive force (Hc), amplitude
permeability (µa), core loss (Pc, Pcv, Pcm), phase (Θ), apparent power (VA)
µ measurement: Max. magnetic flux density (Bm), max. magnetic field (Hm), impedance permeability (µz), complex permeability (µ, µ"), amplitude
permeability (µa), core loss (Pc), phase (Θ), loss coefficient (tanδ), inductance (L), resistance (R), impedance (Z), quality factor (Q)
Waveform display B-H curve, waveforms of excitation current, induced voltage, magnetic field, magnetic flux density
Measurement frequency 10Hz to 10MHz 10Hz to 1MHz
Magnetic field signal detection Voltage drop at both edges of non-inductive resistor Maximum signal detection current: 6A
Magnetic flux density signal detection Voltage detection at both edges of induced voltage detection coil Maximum signal detection voltage: ± 200 V
Digitizer resolution 16 bits (8,192 points/cycle)
Sample connection method 2 or 1 coil (winding) method
Display Color LCD display (800 x 600 pixels)
Power supply AC100V to 240 V, 50/60Hz, Power consumption: Approx. 130VA MAX
Weight and dimensions Main unit: Approx. 12.5kg, 420 (W) x 266 (H) x 480 (L) ± 2mm (without the projection section)
Interface USB (data storage)
Features
• A maximum of twenty temperature conditions and a maximum of fourty excitation
conditions can be set for a single test sample, which enables 800 (= 20 x 40)
different types of programming for the measurement conditions.
• Pulse excitation for the B-H analyzer can also be remotely controlled.
• Hard copies of the B-H analyzer measurement screen can also be automatically
saved onto a USB memory in the JPEG or PNG formats.
USB - GPIB interface: NI GPIB-USB-HS hi-speed GPIB controller by National Instruments recommended.
System configuration of
the constant-temperature SY-509 USB-GPIB converter 408JE-101 GPIB cable
scanner system remote GPIB GPIB
control
POWER
B-H Analyzer INPUT
USB SY-8218/8219 USB (BNC)
Power Amp
B&H
signals
System configuration USB - GPIB interface: NI GPIB-USB-HS hi-speed GPIB controller by National Instruments recommended.
of just the B-H analyzer 182766-01 bulkhead adapter manufactured by National Instruments
B-H Analyzer
USB SY-8218/8219 USB
Power Amplifire
34
Main Options and System Examples
Constant-temperature Scanner System Options
Constant-temperature Chamber scanner system Spare turntable
SY-320 SY-510
SY-321 SY-511
For evaluations of samples’ magnetic A table for
characteristics vs temperature mounting samples SY-511
Automatic measurements possible with the SY-810 (software.) Scanner Number of samples
Temperature Range -30℃ to +150℃ SY-510 SY-320 20pcs
SY-320 20pcs SY-511 SY-321 41pcs
Sample Quantity
SY-321 41pcs
*Supplied with the SY-320 x 1unit and SY-321 x 1unit as standard
Maximum Measurement Current 6Apk
SY-321
Software Options
PC Software Interface
SY-810 NI GPIB-USB-HS
Remote Control Software GPIB Controller Supporting
(Supplied with the SY-509 and bulk head adaptor as Hi-Speed USB
standard accessories.)
The NI GPIB-USD-HS manufactured by National Instruments is
A USB-GPIB converter for use with controllers
required separately for PC connection purposes. (see page34)
connected to PCs when the SY-810 remote
control software is being used.
Interface
SY-509
USB-GPIB Conversion Adaptor
*Supplied with the SY-810 as standard equipment.
Power Amplifiers
Model Frequency Output Current Output Voltage Power Consumption
Example of Full-automatic B-H Analyzer with Constant Temperature Scanner System Empty toroidal coil
for various evaluations SY-513
Temperature range : -30˚C to +150˚C A toroidal-shaped empty case.
It is used for measurement of a
Max. number of samples 20 : SY-320 powder sample.
Max. number of samples 41 : SY-321
Remote control PC software SY-810(option)
Constant
Temperature
Chamber
Control PC Scanner System
SY-321 for Max.
41 samples
Temperature range :
-30˚C to +150˚C
(SY-320: 20samples)
CS(EB)1204-832-1-03
8511-3097-0