Specifications - 700-HA Relays: Electrical Ratings

This document provides specifications for 700-HA series relays and timers. It outlines their electrical ratings including pilot duty rating, rated thermal current, rated insulation voltage, contact ratings, and permissible coil voltages. It also specifies their mechanical properties such as operating times, vibration endurance, shock resistance and operating temperature range. The document concludes with details on construction materials, terminal markings, certifications and applicable standards.

Uploaded by

Arif Khan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
79 views1 page

Specifications - 700-HA Relays: Electrical Ratings

This document provides specifications for 700-HA series relays and timers. It outlines their electrical ratings including pilot duty rating, rated thermal current, rated insulation voltage, contact ratings, and permissible coil voltages. It also specifies their mechanical properties such as operating times, vibration endurance, shock resistance and operating temperature range. The document concludes with details on construction materials, terminal markings, certifications and applicable standards.

Uploaded by

Arif Khan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Relay and Timer Specifications

Specifications - 700-HA Relays


Attribute 700-HA
Electrical Ratings
Pilot Duty Rating (1) NEMA B300
Rated Thermal Current (Ith) HA = 10 A – 120V, 240V; HAX = 6 A – 120V, 240V
Rated Insulation Voltage (Ui) 250V IEC – 300V UL/CSA
Make Break Hp
Inductive

120V AC 30 A 3A 1/3
Contacts
240V AC 15 A 1.5 A 1
General-purpose 10 A, 240V AC
Resistive 10 A, 30V DC
Min. Low Energy Permissible Load HA = 10V, 5 mA HAX = 5V, 2 mA
Permissible Coil Voltage Variation Pickup: 80…110% of nom voltage at 50 Hz, 80…110% of nom voltage at 60 Hz, 80…110% of nom voltage at DC
AC Coils 50 Hz 60 Hz
Inrush 3.3VA 2.85VA
Coil Consumption ±10%
Sealed 2.2VA 1.9VA
DC Coils 1.3 W
Must Dropout Voltage 20% of nom V AC; 10% of nom V DC
Max. Contact Resistance 50 MΩ (700-HA), 30 MΩ (700-HAX)
Design Specification/Test Requirements
Electrical
Pole-to-Pole 2000V
Contact to Coil 2000V
Electrical Life (Operating) 100,000 min.
Mechanical
Degree of Protection (Open Type) IEC 529 IP 40
Mechanical Lifecycles (AC/DC) > 20 x 106/ 50 x 106
Switching Frequency Operations 3600/HR
Coil Voltages See Product Selection
Pickup 12 ms
Operating Time
Dropout 12 ms
Maximum Operating Rate 4 Ops/s
Endurance 5G
Vibration
Operational 2.5 G
Endurance 50 G
Shock
Operational 9G
Environmental
Operating AC/DC –40…+70 °C (–40…+158 °F)
Temperature
Storage AC/DC –40…+100 °C (–40…+212 °F)
Altitude 2000 m (6560 ft)
Construction
Insulating Material Molded High-Dielectric Material
Enclosure Transparent Dust Cover
700-HA: 10 A – AgNi
Contact Material
700-HAX: 6 A – Bifurcated/Gold Plating AgNi
Terminal Markings on Socket In accordance with EN50 0005
Sockets 8-Pin Socket — 700-HN100, -HN125, -HN204, 11-Pin Socket — 700-HN101, -HN126, -HN205

Certifications cURus Recognized (File No. E3125, Guide NLDX2/NLDX8), cULus Listed when used with 700-HN sockets noted (File No. E3125, Guide
NLDX/NLDX7), CE Marked, CSA Certified, UR Certified (File 229473)
Standards UL508, CSA C22.2 No. 14, EN 61810-1
(1) See NEMA Ratings and Test Values on page 5