1 HEAT EXCHANGER SPECIFICATION SHEET Page 1
2 MKH Units
3
4 Job No.
5 Customer ABC Refinery Reference No.
6 Address XYZ Proposal No.
7 Plant Location Date 3/30/2010 Rev
8 Service of Unit Item No.
9 Size 838.200 x 4876.94 mm Type AES Horz. Connected In 1 Parallel 1 Series
10 Surf/Unit (Gross/Eff) 161.89 / 147.58 m2 Shell/Unit 1 Surf/Shell (Gross/Eff) 161.89 / 147.58 m2
11 PERFORMANCE OF ONE UNIT
12 Fluid Allocation Shell Side Tube Side
13 Fluid Name
14 Fluid Quantity, Total kg/hr
15 Vapor (In/Out)
16 Liquid
17 Steam
18 Water
19 Noncondensables
20 Temperature (In/Out) C
21 Specific Gravity
22 Viscosity cP
23 Molecular Weight, Vapor
24 Molecular Weight, Noncondensables
25 Specific Heat kcal/kg-C
26 Thermal Conductivity kcal/hr-m-C
27 Latent Heat kcal/kg
28 Inlet Pressure kgf/cm2A
29 Velocity m/s
30 Pressure Drop, Allow/Calc kgf/cm2
31 Fouling Resistance (min) m2-hr-C/kcal
32 Heat Exchanged kcal/hr MTD (Corrected) C
33 Transfer Rate, Service kcal/m2-hr-C Clean kcal/m2-hr-C Actual kcal/m2-hr-C
34 CONSTRUCTION OF ONE SHELL Sketch (Bundle/Nozzle Orientation)
35 Shell Side Tube Side
36 Design/Test Pressure kgf/cm2G 12 12
37 Design Temperature C 200 200 838.2
mm
38 No Passes per Shell 1 2
39 Corrosion Allowance mm
4876.9
40 Connections In mm 200 300 mm
41 Size & Out mm 200 300 Vendor Drawings & Tube layout
42 Rating Intermediate @ @
43 Tube No. 416 OD 25.400 mm Thk(Avg) 2.769 mm Length 4877. mm Pitch 31.800 mm Layout 90
44 Tube Type Bare / Finned Material CARBON STEEL
45 Shell ID 838.200 mm OD mm Shell Cover
46 Channel or Bonnet Channel Cover
47 Tubesheet-Stationary Tubesheet-Floating
48 Floating Head Cover Impingement Plate Yes / No
49 Baffles-Cross 15 Type SINGLE-SEG. %Cut (Diam) 26.39 Spacing(c/c) 382.354 Inlet 535.464 mm
50 Baffles-Long Seal Type
51 Supports-Tube U-Bend Type
52 Bypass Seal Arrangement Tube-Tubesheet Joint
53 Expansion Joint Type
54 Rho-V2-Inlet Nozzle kg/m-s2 Bundle Entrance Bundle Exit kg/m-s2
55 Gaskets-Shell Side Tube Side
56 -Floating Head
57 Code Requirements TEMA Class
58 Weight/Shell Filled with Water Bundle kg
59 Remarks:
60 1-Fields marked in red are the minimum information (if applicable to a exchanger) needed to rate a exchanger.
61 2-In addition to this information, vendor drawings and tube layout is often needed to rate a exchanger with desired accuracy.
62 3- If finned tubes are used, then details of fin geometry is required.
62 4-Inlet & Outlet piping Isometrics are often required to rate a thermosiphon reboiler
62
D:\Project Work1\956036\Done\FLRS-E-106\FLRS-E-106.htri