0 ratings0% found this document useful (0 votes) 1K views12 pagesTanaka Catalog
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here.
Available Formats
Download as PDF or read online on Scribd
mT 41 4)
eC eae TTDAutomated Flash Point Testers
Since 1966, Tanaka has been delivering automated flash point testers for
higher productivity at petroleum laboratories. The theme of the 8th
generation model series is " Ergonomic, Versatile and Premium "
‘ Figonomicaly cola-coordnatedasplay fr high vist fr everybody (universal design and intutve switch operation.
€@ Enhances versaity including UB por fr optional fash drive or keyboard passwort protection and data storage (200 ess)
€@ Alkin-one chass's design: compact ight-veight and premium exterior design
Abel Closed Cup Flash Point Tester (DI-8a / abl-81
ab san automated Abel Closed Cup fash pon tester to cover fammable and combustile
rate for sieping and safety regulations. Heating /coling i ay energy eficent Pair
rmodils attached toa metal black bath, Aircoles enodel abl-ta and igus cole model
bh areavalabe or diferent temperature anges Model ab¥8lvequves an optional hier)
ce
Test Methods 150 13736, 170,60 1518 /1523
Measuring Range +10" 10 +170 forabl fo
30°C to +110°C for abl (with an optional chiller)
Temperature Sensor PT-100in stainless stel sheath
FashDetector ——CRCthemocousle
Igntlon Source Gas Mame orlectrccol
voren RS-232C and USB, each
Sae(WxDxH) — 280%470%390mm
eign 194
Power Consumstion 250VA,
Tag Closed Cup Flash Point Tester ({G-SUfc / atg-8afc / atg-8Ifc
atgsisan automated Ta Closed Cup fash point tester Model atg vfs wth convetional
water bath. Medel ag-fafc and atg-sfe are avalible ‘ol temerature range. the cooling
‘Theaing fer these models are by Petar modules (Modalatg- requires an optional chile)
Furthermore tw standard equipped with fee containment system. It can extinguish fre
neers Gg
effectively ey flowing quenching gas {NCOs} ome
Test Methods -ASTIADS, IP 304, 15K2265-1
Measuring Range ‘Amblent0 495°C fr atg-8wfc
45°C 10 175°C foratgtate
20°C 19 195 C for ats with an ostional chil
lemperature Sensor 71-10 n stainless tet seth
Flash Detector ‘aCThermocourle
Ignition Source ‘Gas ame or elect cai
WoPen 5-232C and USB each
Size(Wx0xH) 2803708390 mm
Weight 1959
Frecontainmens system Power Consumption 31-500 VA man. atg af atg-H=250VA fan)
Pensky-Martens Closed Cup Flash Point Tester apm-8fc
apm-tfcis an automated Penshy-Martens Clases Cup fash point tester. Numerous tes
methods are bulk into accomatat varous samples Procedure-Aforhomogeneous pa"
eum tauiss such a dilate fuels, Procedure-® for residual fl oil and same other
nonhomogeneous Iquds,Pocedure-C or besisel SPE modefor samples wth unknown
‘expected eh poi, CRM mode for CRMs, Custom mace where heating
ean beset
freey, and 80 15267 mode for animal and vegetable ats and ols. Furthermore, star
dard equipped fre containment system It can extinguish te erecively ay flowing
quenching gos or) fom exeral connection por. ce
Test Methods 150.2719, 150 15267, ASTINDSS, 1934115 2265-3
Measuring Range ‘ambient to 370°C
Temperature Sensor 1-10 in stainless ste seth
Fish Detector ‘RC thermocouple
Igation Source “cas fame or elec call
voPon R5-282C and USB each
Sze(Wx0xH) 2804703300.
Weigrt 1949,
Power Consumtion TROWA (mae
Fire containment system
=
1
Tanaka Scientific LimitedTANAKA
Further improved Swing Arm assembly
for easy setting and cleaning :
-Aterinserting the test cup in the instrument, justlower the swing sensor, fash detector and tier (incase of a-8 and apr). After
arm assembly onto the test cup to set all the necessary compo- the tes, lit the arm to the complete upriaht position for easy
nents for the tes, incliging the ignition source, temperature cleaning
Cleveland Open Cup Flash Point Tester (CO-8 / (CO-8dS
aco isan automated Cleveland Open Cup (COC ash & fire point taster Gas test fame is
igntes automaticaly, Fre cin is detemined automatically when sustaining combustion
hasbeen detected or sec Fire containment bya metalic id covers the st cup automat
cally when 3 sustained fre i getectes Model aco-aifortertng btuminovs materials
ce
Test Methods 150.2592, ASTM D82, P36, 1182265-4
Measuring Range ‘Ambien to 400°C
Temperature Sensor 1-10 stainless tel sheath
Fash Detector Deut nization rings
Ignition Source ‘Gas ame with 2p electric cols
voPen 5-232C and USB, each
Sze(Wx0xH) 280%470%400 mm
Weignt 17g
Power Consumiion 11000 Wimax)
@
cosas forbtumen appliations Fre containment In open positon li} Fre containment closed
{Eouinped with TF surace sen remover)
6 Positions Cleveland Open Cup Flash Point Tester ACO-T602
[ACO-T602 automaticaly carries out COC flash point test of up te 6 samples
Continuously. For large sample numbers, this carousel model reduces the
‘burden on the laboratory personnel. Easy programming: Up to 6 sample types
data can be stored and later recalled for easy programming of routine tess
Flectuc ignition: Relacle, easy, and safe ce
Test Methods 1502582, ASTIAD92/ P36, ex,
ype Programmable with poston carousel
TTemourtute Sensor P7-100in stainless steel sheath
Fash Detector Iprization between est cupand igniter Patented)
Igation Source 2xEktvie cols
Safery Heater cut-off an fire containment Fd
voPon 2xRSI3IC
Size(WxDxH) Testun 4105203400 mm contour 230x460 110 mm
wert Convolunt: Phy test unt: 34g
Power Consumption 1500W(max)TEMPE Ms le
Automated Distillation Tester It’s been over 50 years since we started manufacturing
automated distillation testers. Nowadays, we deliver to
a _ 7 customers in more than 70 countries.
ad-7 automatically performs distillation test of petro-
leum products prescribed in “Standard Test Method for
Distillation of Petroleum Products at Atmospheric Pres-
sure’, as well as narrow boiling range samples with
optional temperature sensor.
|
varsaica
3
Tanaka Scientific LimitedTANAKA
Ergonomic : Universal design for intuitive operation
Premium —: Premium design for extended pro use.
Versatile |: Enhanced functions for more elaborate analysis.
+ The world’s srnallest class size of footprint.
+ Cooling/Heating by Peltier Cooling system
+ 10.4 inch Color LCD that is 4 times larger than previous model.
+ Intuitive operation by Touch Panel
+ 200 test modes can be recorded.
+ Test mode for unknown sample is available,
+ Test with less than 100mL sample is possible.
+ 5,000 test results can be stored.
+ Fire containment system with CO2 gas. (When ultraviolet sensor detects a fire,
CO? gas flows into the heater room if connected to CO? source.)
+ PC software for data management(TDAS) is included in standard accessories.
ce
sea 150205, P23, ASTOR /D850/0I078 IBKEDSE
fanae Aber 0459°C
ey TLD Wah cortouchceen wth univers ign
Teper Svior 70 Vp Conder and Reeve,
Terma rer
Heer 2AV OW Lowman low vote heer il ype
Ditaon ae 45 Wirimac ct (alec fom 2109 wth OS ETE
Teste Upto temas canbe coded
acd Otemest rion Fe coninnent tm
Cnecten \siconeten dbo corecton
SSS 52226 USK and here each
Sex aH) 2095204710
woos 35
over Souce 500VRGma0UT oR eee ML a ae
For the cold behavior tester series, unique and
efficient cooling systems that do not require either
large capacity chiller or methanol have been adopted.
Asa result, the maintenance cost as well as environ-
mental burden have been greatly reduced
Pour / Cloud Point Tester MPC Series
TTANAKA’s MPC series has been designed for automatic
determination of POUR POINT (PP) and CLOUD POINT (CP)
with small specimen size and shorter test cycle time while
securing better test precision than the conventional
‘manual methods
PP measurement is by "AIR PRESSURE METHOD" (ASTM
106749), and CP measurement is by "SMALL TEST JAR
METHOD" (ASTM 07683).
The epoch-making automatic PP test method yields 1°C
test resolution, while the new CP method yields 0.1°C
resolution
Principle of Pour Point Detection
Pour / Cloud Point Tester
MPC-102S
5 Tanaka Scientific Limited
No pressure
rise detected
es
Test methods
>HE 35
PP - ASTM 06748, D97, 150 3016
CP : ASTM D7683, 02500, 150 3015
Ultra Low Temp Without Liquid Chiller
with a ayo block bath, model CB-80C manufactured by SCI,
MPC. 1025 works without an exemaliquid chiller
Compact Design & Energy Efficient
A compact and energy efficent cro block bath model C-80C i
capable of cooling the samples to -65°C whhout a lquid chile
Elecicty consumption is only 20% comparing ta MPC-=102L with
cexeal igi ciler
ce€e
‘Type Bench top, | potion witha eye blocksath
Measuring Range 45 "Cro 451°C
Diply Vid module
voPon TeRS232e
Size(WxDxH) —30034603320mm
Weight Big
Power Consumation T6OVACmas)TANAKA
Pour / Cloud Point Tester
MPC-102A / MPC-102L
‘MPC-102A MPC-102L
4 Benchtop, postion Benchtop, postion,
ve ‘wth a ook Petr cooler sth gue cle Peles cooker
NMessuing Range -25°Ct0451"Cin25"Cambient 45 °C10.+51 “Cwhen used with
Tet oF TCL-402 chile optional
WoPon 1 xRs.232 1xRs252¢
Diphy YEO meddle vrD module
Sae(WxDxH) 230% 480% 390mm 230480399 mm
Weignt 1949 204g
PowerConsumstion 300VACmax) 300 VAC
ce ce
Pour / Cloud Point Tester
MPC-602
ce
Type Bench top postions with Equi cooled Peer
Measuring Range 85 "C20 451 ‘Cwhen use wth 3 sets of TCU408 chile (optional
Disply FO medile
woPon Tens252
Sze(WxDxH) —800x550x850mm
Weight 100%
Power Consumption 1S00VA\max)
CEPP Tester AFP-102 automaticaly executes the Cod ier Plging Pins (CFPP tet methos
prescibed in 30, ASTM 08371 andJISK2788, After developing ts predecessor
AFP-102 models, this third generation model has been developed by applying Tanaka’
latest technologies and the various know-haws. "Ease of operation” has been
further improved on this model
ce
TestWethods ASTM 6371, 19308, ENTS
Type Bench top| positon, with uid coca Pebiercooler
Measuring Range -50°Ctoambientshen ved with 1 set of ICU-408 chiller (optional
Disply veO meddles|
voPor 5-232C teach
Sze(WxDxH) 3505503 480mm
Weight 2619
Power Consumtion 60VA(max)
Chiller Unit TCU-408 refrigerated circulator is suitable for TANAKA MPC-102L / 602 and
TCU-40B aS :
[eas Te ge 40"cioanbet
“ Coomsconey a Watare
= Sme(WxOxh)——-BOS10x75 nm
oy were Ssiginw
PonerConnpon OVA
=Aniline Point, Softening Point
Aniline Point Tester aap-6
aap-5 automatically determines aniline point of wide range of samples. The use of special
Infrared detector gives the instrument the ability to "see" through dark opaque samples such
as power generation fuels and marine diesels. The measuring cellcan be exsly removed and
placed on an analytical balance for weighing viscous samples which are solid at ambient
temperature. The measuring cell can be cleaned without disassembling, which makes the
cleaning easier and safer
Test Methods
Samples
ange
Sample call
Detection
voPer
Sze(Wx0xH)
Weight
Power onsumion
1802877, ASTM SII, ete
Transparent or opaque / dark 80.0n ASTM color scal) petroleum products
Ambient 170°C below RT wit optional jackeves cell and extemal chiller
Mosifed Utube
Photarelecic detector
S-282C, USB, and Ethemet,Y each
2304703480 mm
Mig
125VAlmad
Softening Point Tester asp-6
“Test Methods
ype
Range
Detection
sting
voor
Size(Wa0xH)
Wehr
Power Consumption
7 Tanaka Scientific Limited
asp- automates softening point tes of bitumen and other materials by utllzing photo-electic
device with a wide light bear, which assures reliable detection, Generation of harmful vapor
from overheated alcerin is prevented by the safety shutdown. Furthermore, aso is small
‘enauigh tobe installeg in 2 fume hood
ce
-ASTMAD3G, ASTM E28, EN 142758.
Ring andl, Des
‘Ambient to 200°C (382°F)
LED /Photo-dode
Magneticstiring (80 to 300m)
RS-252C, USA and theme. each
280%470%440 mm
159
1.S00VACmas)eee TANAKA
Micro Carbon Residue Tester Ac8-m3 automates the vaporizing / coking process of Micro carbon residue test, the result,
ACR-M3 ‘of which has been found wel conelated with conventional Conradson method's. Further-
more, due tits more consistent proces, it yields better precision. This secand generation
model has been further improved for its ease of use and test throughput.
ce
“Tess Methods 150 10370, ASTM 04530, ete.
Range Up to 500°C
NsGasFow Rate ‘Automatiallyregusted and displayed onthe rant panel
Sze(Wx0xH) "350% 390.480 mm
Weight 20g
PowerConsumesion 1600 Vmax)Viscosity, Vapor Pressure, Color
Kinematic Viscosity Measuring System
AKV-202
|AKV-202 has been designed for automatic determination of Kinematic viscosity. Once sample is set,
f the series of processes including timing, clezning/drying, and reporting ate fully automated,
AAKV-202 is an economical bench top system which saves not only the technicians’ time but also
valuable laboratory floor space
Test Methods 150 3104, ASTIADMAS, #71, et
pe Bench tp automatic KV measuring system with 2vcometersin bath
Range 110 10000 mms
icomater Modified Lana-Zetfchs ype
athTemp rset a points. Preset aon’ can be set a any temp beeen 20 and 100°C
vorer TRIE
Sze(WxDxH) $30 550x980mm
a ry Weight Big
PowerConsumerion 2000VA (mad
Reid Vapor Pressure Tester
AVP-30D 7220 2omstcaty mesures es vapor sree mattangamnacuted nr Wie ase foperaion
snd svar intrument ze ae achieved with the smaller siz cylinders, tet result precely agrees with tat ofthe
regu sze Reid cylinder. Compact size: Widths merely 400mm, Relble eclent sess shaking mechanism
‘Test Methods 150 3007, ASTM 0323, P88 ee.
Type Bench-iop with 2,3, 0F4 demisze clnrs
ange © to 196} (2k)
hinder Sains steel eyiner with approx. 60% in length and 30% in volume of regular ed cylader
voPen 1 xRS.232¢
Sze(WxDxH) —— 400%600%740.mm
Diy Weight 454g
PowerConsumsion 115 17OOVA(may), 230 1400 ¥ACmae)
‘option Manometer
*1yP-300 comes wih ether23,0r4eylnders, When inuitng, spel the numberof ners
Colorimeter for Petroleum Products
ACL-2 ACL2 aera deterines Sabo ASTI and other clos utng the
Tits method prescbedin ASTI DES, whch gevertes equal et
tests th the conertoral mana precionn ypkaly second Seno
‘ubectve arene needs tobe cae, pecr acd acheved
ce
TertMethods ——_ASTMDSOS,0156,01500
a. Tee “stimu ler cobrimeter
POE sens an peer
Samal Cells ‘cas cells or optional iow cls
woren R520
. E Siee(WxDxH) —400x400%180mm
Weight ig
Power Consumption 130VA(max
9
Tanaka Scientific LimitedSTOLE 24s
EDXRF Sulfur Analyzer
1X-630SA
EDXRF Sulfur Analyzer
RX-360SH
—
omy
-~
a
—
NEW
WDXRF Sulfur Analyzer
FX-700
TANAKA
«62050 determines total suturinpetleum product using enery-dspesve
Xray Auorescence (EDXAE) method, which is a quick nonedestucve, ana
economical method. n-605A does nat need helium gas and vacuum pum,
only AC powers needed. The Ci corteton calraion curve hasbeen set at
the acon operator doesnot need to makea cliration cue or every product
‘ype. Oncea sample set, the total uur determines automaticaly in 300:ec
(yp. 8305A equipped nth a 12-postions carousel forhigneraroductie
iy, and color ouch screen frintuitve operation
ce
Test Methods 150 8754, ASTM D4284-03, 15K 2541-4 ete
Type postions
ange 151mg /kg 100) 0 6c0 me
Size(WxDxH) —$60%360:270mm
Weight 2th
PewerCensumtion 200A (mand
RX-3605H isa single test version of Xray sulfur meter taking the same measuring
principle as that of n-5305A. Compact housing with acatying handle and way
ower source (100-240VAC or T2¥DC battery) allows such applications as
spot-checking in the files The only consumable s smal piece of Cell sheet.
ce
Test Methods 150 8754, ASTM D4294-03, D-<284-05, ISK 254-4, ee
Range’ 15 mg/kg (00) © 600 056
Siae(WxDxH) ——420%380.140.mm
Weight 125kg
PowerConsumption 100VA (max)
FX-7OOMI2. determines total sulfur in ultra low sulfur (ULS) fuels using
wavelength dispersive X-ay fluorescence (WDXRF) method, which is a quick
‘easy and economical technique. Taanks to its dedicated design for ULS, the
‘operation has been simplified to the extreme. With 8.4 inch Full-color touch
panel, operation can be made easly and inultively, and robust interlock mecha-
nism ensures safety against X~ay.
ce
Test methods 150 2088, ASTRA D2622-95, ISK 2581-7
Range: 15200} 0 990 mg/kg
Siee(W:DxH) —600500520.mm
Weignt sig
PowerConsumption 300VA (max)
P1004 requis Helam ga or purging
10POE
Tanaka Scientific Limited
PAL re ee ers aE
TEL: +81-3-3620-1711 E-mail: overseas-group@tanaka-sci.c
FAX: +81-3-3620-1713 URL :www.tanaka-sel.