0% found this document useful (0 votes)
112 views1 page

Leah Wilmer Batac Electrical

This document contains an electrical site plan and specifications for a medical center. The site plan shows the layout of the property with two panel boxes, power and lighting details. The specifications state that all electrical work will comply with Philippine and local electrical codes. It provides the location of the property relative to nearby roads and cities.

Uploaded by

Arjay Aleta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
112 views1 page

Leah Wilmer Batac Electrical

This document contains an electrical site plan and specifications for a medical center. The site plan shows the layout of the property with two panel boxes, power and lighting details. The specifications state that all electrical work will comply with Philippine and local electrical codes. It provides the location of the property relative to nearby roads and cities.

Uploaded by

Arjay Aleta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

THIS SITE

FULAMUJI STREET
6
Spn
o

SMITH STREET
p
acu

7 ELECTRICAL SPECS/LOAD
n 3 COMPUTATION
1 : 12
Sqr m
q

TH
panelbox 2
5
Slmo panelbox 2
r
SINGLE LINE DIAGRAM/POWER RISER R
NO
l
2-14.0 sq.mm THHN, Copper in 25mm dia.
1 Sk
k rigid steel conduit pipe
h
Sj
2-8.0 sq.mm THHN copper
j wire in 25mm conduit
Sghi MARIANO MARCOS
g MEDICAL CENTER
3 60A 15A

i 2 15A 20A
1
40A 15A
TO LAOAG CITY NATIONAL ROAD TO MANILA
M 2 3 5
20A 20A
20A 40A
f Sf 6 7
4
20A panel box 2 LOCATION MAP1
spare
20A
spare 4 1 : 350

panelbox 1 ELECTRICAL SPECIFICATIONS


e
Se LEGENDS:
4 PANEL BOX THE ELECTRICAL WORK HEREIN HALL BE ACCORDANCE WITH THE RULES AND
REGULATIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE,
PARTI 2000 AND THE REQUIREMENTS OF THE ILOCOS NORTE ELECTRIC
pinlights/INCANDESCENT BULB COOPERATIVE, INC.
THE ELECTRICAL WORK HEREIN SHALL BE DONE IN PVC PIPE, CHEDULE 40,
CONVINIENCE OUTLET RUN EMBEDDED IN REINFORCED CONCRETE LAB AND CONCEALE BETWEEN
WOODEN DOUBLE WALL PARTITIONS AND HOLLOW BLOCK STRUCTURES.
WALL SWITCH HOMERUN, EMBEDDED
ALL MATERIAL AND WRITING DEVICES TO BE USED HEREIN SHALL BE NEW AND OF
c METER
d Sdc M THE APPROVED TYPE FOR WHICH THEY ARE INTENDED.
WHENEVER REQUIRED AND NECEARY, PULL BOXES AND JUNCTION BOXES SHALL BE

s abc
WALL SWITCH,Abc INSTALLED AT CONVINIENT AND INCONPICIOUS LOCATIONS ALTHOUGH SUCH BOXES
ARE NOT HOWN OR INDICATED IN THE PLAN NOR MENTIONED IN THE SECIFICATION.
THE ELECTRICAL WORKS HEREIN HALL CONFORM WITH THE NEA-INEC STANDARD SYTEM
EMBEDDED/CONCEALED PVC RUN
OF LINE-TO-GROUND, OTHERWISE THE EXISTING LINE-TO-LINE YTEM SHALL PREVAIL.
THE MINIMUM SIZE OF CONDUCTOR TO BE USED HEREIN HALL BE NO. 2.0SQ.MM, TW,
COPPER AND THE MINIMAL DIAMETER OF PVC PIPE SHALL BE 15MM, SCHEDULE 40.
b THE TYPE OF POWER ERVICE TO BE SUPPLIED HEREIN SHALL BE AC 230V, SINGLE PHASE,
Sab TWO-WIRE, 60HZ.
PANELBOX PANELBOX
THE ELECTRICAL WORKS HEREIN SHALL BE DONE UNDER THE DIRECT SUPERVISION OF
A DULY LICENSE ELECTRICAL ENGINEER OR REGISTERED MASTER ELECTRICIAN.
a
SCHEDULE OF LOADS
NO DESCRIPTION L.O. C.O. LOAD/WATTS VOLTS AMPERE RATING/POLE FEEDER/CONDUIT

PANELBOX 1
1 Lightinq Outlet 5 500 230 2.17 15 Amp 2-2.0 sq.mm THHN in 20mm dia. PVC
2 Lightinq Outlet 6 600 230 2.60 15 Amp 2-2.0 sq.mm THHN in 20mm dia. PVC
3 Convinience Outlet 6 1200 230 5.21 20 Amp 2-3.5 sq.mm THHN in 20mm dia. PVC
4 Convinience Outlet 5 1000 230 4.34 20 Amp 2-3.5sq.mm THHN in 20mm dia. PVC
LIGHTING LAYOUT POWER LAYOUT PANELBOX 2 3800 230 16.52 40 Amp 2-8.0 sq.mm THHN in 25mm dia. PVC
2 1 : 100
1 1 : 100 SPARE 1 230 6.52 20 Amp
1500
SPARE 1 1500 230 6.52 20 Amp
TOTAL 10100 230 43.91 60Amps 2-14.0 sq.mm THHN in 25mm dia. PVC
PANELBOX 2
5 Lightinq Outlet 5 500 230 2.17 15 Amp 2-2.0 sq.mm THHN in 20mm dia. PVC
6 Convinience Outlet 5 1000 230 4.34 20 Amp 2-3.5 sq.mm THHN in 20mm dia. PVC

7 AIRCONDITIONED UNIT 1.5 HP 1 2300 230 10.0 20 Amp 2-5.5 sq.mm THHN in 20mm dia. PVC
SUB-TOTAL.............................. 3800 230 16.52 40 Amp 2-8.0 sq.mm THHN in 20mm dia. PVC

NET COMPUTED CURRENT=Ifl= (10100/230)X0.80+2300X.25/230=37.63 Amperes


60AT,2P,240V,60Hz MCB
FOR THE MAIN: _________________________
USE: 2-14.0sq.mm.Thhn WIRE in 25 mm dia. RSc

DESIGNED BY: PROJECT TITLE: CONFORME: SHEET CONTENTS: SHEET NO.

ELECTRICAL ENGINEER Address:

PTR NO. REG. NO.


CHECKED BY: AS-BUILT PLAN OF THREE BEDROOM BUNGALOW SPS. WILMER & LEAH GARALDE
ISSUED ON: TIN:
DATE: LOCATION: OWNER
ISSUED AT: FULAMUJI STREET, CALLAGUIP, BATAC CITY