Hydraulic Breathers & Filters Guide

This document discusses spin-on breathers and desiccant breathers that help control contamination in hydraulic systems. Spin-on breathers use glass media elements with efficiencies down to 0.3 microns to prevent contaminants from entering systems. Their high capacity pleated elements extend the life of other filters. Desiccant breathers contain chemically inert silica gel that adsorbs water vapor and indicates reaching maximum capacity by changing color. Both product types work with Hy-Pro fluid filters to provide clean fluid and protect system health.

Uploaded by

Oscar Navarro
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
57 views4 pages

Hydraulic Breathers & Filters Guide

This document discusses spin-on breathers and desiccant breathers that help control contamination in hydraulic systems. Spin-on breathers use glass media elements with efficiencies down to 0.3 microns to prevent contaminants from entering systems. Their high capacity pleated elements extend the life of other filters. Desiccant breathers contain chemically inert silica gel that adsorbs water vapor and indicates reaching maximum capacity by changing color. Both product types work with Hy-Pro fluid filters to provide clean fluid and protect system health.

Uploaded by

Oscar Navarro
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Breathers (Spin-on & Desiccant)

Spin-on Breathers
Adaptors and Disposable Breathers

Fluid contamination is the root cause of


most hydraulic system failures.
Controlling contamination in the air a
system breathes is critical. The synergy
of Hy-Pro fluid filter elements and Hy-Pro
Spin-on breathers yields clean fluid and
a healthy hydraulic system.

PRODUCT SPECIFICATIONS SPIN-ON BREATHER APPLICATIONS

Media Code Media Efficiency (Air) • Replace ineffective filler / breather caps
3M 0.3µ absolute
6M 0.6µ absolute • Control contaminant ingression with glass media
10C 3.0µ absolute elements
12M 1.0µ absolute
• High capacity, High efficiency pleated elements
25C 10.0µ absolute
extend the life of other filters in the system.
25M 2.5µ absolute
Operating temp. -20f (-28c) to 200f (93c)

SPIN-ON BREATHER + ADAPTOR ASSEMBLY INSTALLATION DRAWINGS

HP75L* -** + ADTB-75 HP75L*-** + ADBB-75 HP76L*-** + ADTB-76 HP76L*-** + ADBB-76

For technical service call 317.849.3535 or fax 317.849.9201 www.filterelement.com


SPIN-ON BREATHER ADAPTOR DIMENSIONS

Spin-on
adaptor A IN (mm) B IN (mm) C IN (mm) D IN (mm) Seal Case
number Overall length Thread length Element connection Reservoir connection Material qty
ADTB-76 2.00 (50,8) 0.50 (12,7) 1" - 12 UNF-2A 3/4" NPT Buna-Nitrile 1
(HP76** series spin-on)
ADTB-75 3.00 (76,2) 0.50 (12,7) 1 1/2" - 16 UN 1 1/4" NPT Buna-Nitrile 1
(HP75** series spin-on)
ADBB-76 2.00 (50,8) 0.50 (12,7) 1" - 12 UNF-2A Bayonet for standard Buna-Nitrile 1
(HP76** series spin-on) filler/breather
ADBB-75 3.00 (76,2) 0.50 (12,7) 1 1/2" - 16 UN Bayonet for standard Buna-Nitrile 1
(HP75** series spin-on) filler/breather

ADTB-75 ADBB-75
ADTB-76 ADBB-76

REPLACEMENT ELEMENT ORDER GUIDE

HP____ - __ __ __
table 1 table 2 table 3 table 4
code flow rate (spin-on size) code length code filtration rating code seal
290 gpm, 39 cfm 4 single 1 β2.5[c] = 1000 (B1 = 200) B Nitrile (buna)
75L4 (5.0” OD x 11.0” OAL) 8 double 3 β5[c] = 1000 (B3 = 200) E EPR
290 gpm, 39 cfm or 3µ nominal cellulose* V Fluorocarbon
75L8 (5.0” OD x 11.0” OAL) 6 β7[c] = 1000 (B6 = 200)
212 gpm, 28 cfm 12 β12[c] = 1000 (B12 = 200)
76L4 (3.75” OD x 5.4” OAL)
10 10µ nominal cellulose*
212 gpm, 28 cfm
(3.75” OD x 8.7” OAL) 25 β22[c] = 1000 (B25 = 200)
76L8
or 25µ nominal cellulose*

For technical service call 317.849.3535 or fax 317.849.9201 www.filterelement.com


Hy-Dry Desiccant Breathers

Hy-Dry Breathers
Disposable Air Purifying Breathers

Fluid contamination is the root


cause of most hydraulic system
failures. Controlling contamination
in the air a system breathes is
critical. The synergy of Hy-Pro fluid
filter elements and Hy-Dry desiccant
breathers yields fluid clarification
and a healthy hydraulic system.

PRODUCT SPECIFICATIONS FEATURES, BENEFITS, ADVANTAGES


Air flow rate From 35 CFM (262 gpm) up to 250 Retro-fit existing With adaptors a Hy-Dry breather
CFM (1875 gpm). reservoirs can be installed on virtually any
Solid contaminant 2 micron, 100% efficiency (35 CFM) existing reservoir. (Versatility)
filtration efficiency Water adsorption Eliminate water contamination
Chemical Impervious to alkalis, mineral oils, from reservoir ingression
resistance non-oxidizing acids, salt water, Minimize rust and acid corrosion.
hydrocarbons, and synthetic oils. Reduce component wear.
HPB-34 (mini) 2.8 fl oz / 0.35 cup water capacity Reduce maintenance costs.
HPB-100 3.1 fl oz / 0.4 cup water capacity Prolong fluid life.
HPB-101 6.2 fl oz / 0.8 cup water capacity Reduce oil oxidation.
HPB-102, B-302 13.9 fl oz / 1.7 cup water capacity Enhance lubricity of fluids.
HPBR-102 13.9 fl oz / 1.7 cup water capacity Chemically inert Gold silica gel is chemically inert,
HPB-108 18.5 fl oz / 2.3 cup water capacity non toxic, non-deliquescent and
HPB-109 18.5 fl oz / 2.3 cup water capacity non -corrosive. (chemically inert)
Operating temp. -20f (-28c) to 200f (93c) Disposable Materials meet U.S Pharmacopoeia
XXI Class VI toxicity requirements.
Contaminant Problem Solution
Hy-Dry contains no metal
Water vapor Rust & oxidation Water
components. (easy disposal)
Additive depletion adsorbent
Freezing silica Color indicator When maximum adsorption is
reached Hy-Dry will turn from Gold
Increased conductivity
to Green as an indicator to replace
Fluid degradation
it. (easy condition indicator)
Solid particulate Component wear 2 micron
Stiction removal Bi-directional Air inhaled is cleaned and dried, and
air flow oil is removed from exhausted air .
Orifice blockage efficiency
100 % Activated carbon As air is exhausted from the tank
Acids & salts Chemical reaction
activated carbon removes oil vapor,
Microbial growth
fumes, and odors. (clean exhaust)
Overheating
Corrosion

For technical service call 317.849.3535 or fax 317.849.9201 www.filterelement.com


HY-DRY DISPOSAL CARTRIDGE ORDER GUIDE
Hy-Dry A B C D Weight CFM GPM Hy-Dry
Number Connection
HPB-34 3.25" (3,3cm) 3.25" (3,3cm) N/A 3.25" (3,3cm) 0.8lb (1,7kg) 10 75 1/2" FNPT
HPB-100 3.5" (9cm) 5.0" (12,8cm) 1.25" (3,2cm) 5.0" (12,8cm) 1.3lb (0.6kg) 35 262 1" schd 40
HPB-101 5.0" (12,8cm) 5.0" (12,8cm) 1.25" (3,2cm) 5.0" (12,8cm) 1.9lb (0.9kg) 35 262 1" schd 40
HPB-102 8.0" (20,5cm) 5.0" (12,8cm) 1.25" (3,2cm) 5.0" (12,8cm) 3.3lb (1.5kg) 35 262 1" schd 40
HPB-302 8.5" (21,8cm) 5.0" (12,8cm) N/A 5.2" (13,3cm) 3.3lb (1.5kg) 35 262 1" schd 40
HPBR-102 9.5" (24,4cm) 5.0" (12,8cm) N/A 5.2" (13,3cm) 5.0lb (2.3kg) 35 262 1" schd 40
HPB-108 10.0" (25,4cm) 5.0" (12,8cm) 1.25" (3,2cm) 5.0" (12,8cm) 5.0lb (2.3kg) 100 750 2" MNPT
HPB-109 14.0" (35,5cm) 5.0" (12,8cm) 1.25" (3,2cm) 5.0" (12,8cm) 5.0lb (2.3kg) 250 1875 3" MNPT

HPBR-102 FOR MOBILE AND HEAVY DUTY APPLICATIONS B

*HPBR-102 assembly is complete with a metal reinforced base, that remains with the
reservoir or gearbox, and a replacement breather cartridge (HPB-302) threaded into
the base. Upon indication remove the cartridge only (HPB-302) and replace with a
new cartridge. The HPBR-102 assembly is recommended for Heavy Duty,
Continuous vibration, Mobile, and Extreme climate applications.
HPBR-102 has a 1” Male NPT connection.
A

WHEN TO CHANGE THE HY-DRY BREATHER

New Hy-Dry breather silica is gold and as the


silica adsorbs water the color will change to
green and then to a very dark green (near black).

C
D

RESERVOIR ADAPTORS

Adaptors are available to retrofit any reservoir or gearbox to accept the Hy-Dry breather. HPB-100 through HPB-102 will
require one of the adaptors displayed below. HPB-108 through HPBR-102 do not require adaptors.

Hy-Dry Type
Adaptor
HPBA-101 Flange (no holes)
HPBA-102 1" Male NPT
HPBA-103 3/4" Male NPT
HPBA-104 Bayonet (standard
filler/breather flange)
HPBA-105 1"-12 UNF
BA-101 (No Holes) BA-102 (1" MNPT) BA-104 BA-105 (1"-12 UNF)
BA-114 (Six Holes) BA-103 (3/4" MNPT) (Bayonet adaptor) BA-106 (1.5"-16 UN) HPBA-106 1 1/2"-16 UNF
Flange adaptors Fits filler breather flange BA-201 (1.125"-16UN-2B)