Standard Operating Procedures
(SOP) for Clinker Cooler
A.   Startup Procedures
      1.   Check to ensure the breakers are on.
      2.   Start the clinker transport system.
      3.   Start cooler bearing air.
      4.   Start the clinker breaker.
      5.   Start the #1 drive fans.
      6.   Start the undergrate fans on #2, 3, and 4 drives.
      7.   Start # 4, 3, 2, and 1 drives.
B. Shutdown Procedures (Normal/Emergency)
      a. Normal Procedures
              1.     The cooler will be shutdown in the reverse order of the
                     startup procedures.
              2.     The cooler and transport system should be run for four hours
                     after the kiln feed has stopped to ensure that it is empty
                     before any maintenance is performed.
      b. Emergency Procedures
              1.     The same procedures will be followed as in a normal
                     shutdown, though some steps may be bypassed depending
                     on the nature and of the emergency.
C.   Malfunctions
     Malfunction         May Results In                Corrective                Documentation
     Description                                  Actions/Procedures
Failure of #1 drive      Shutdown of         Inspect and repair and/or          Malfunction
position sensor          cooler              replace sensor, as necessary.      Report Generated
                         Excess Emissions
Fan failures (bearings   Clinker cooled at   Shut down kiln and/or cooler,      Malfunction
and electrical faults)   a reduced rate,     as necessary. Inspect and          Report Generated
                         cooler does not     repair fan, as necessary. If
                         provide             available, use stand-by
                         secondary air to    undergrate fan.
                         kiln
                         Excess Emissions
Loss of hydraulic        Motion loss of      Shut down and inspect to           Malfunction
pressure to #1 drive     grates              determine cause of failure.        Report Generated
                         Excess Emissions    Repair as necessary.
Loss of hydraulic oil    Motion loss of      Shut down and inspect              Malfunction
cooling system           grates              cooling system and repair, as      Report Generated
                         Excess Emissions    necessary.
Failure of tipping       Inability of        Inspect valves and/or shut         Malfunction
valves                   cooler to           down cooler, as necessary.         Report Generated
                         discharge clinker   Repair and/or replace valves
                         Excess Emissions    as necessary.
Plant power failure      Shut down of        Inspect to determine cause of      Malfunction
                         cooler              failure. Repair, if possible, or   Report Generated
                         Excess Emissions    notify proper authorities.
Loss of grate            Buildup of          Inspect for broken or missing      Malfunction
                         clinker in bottom   grate. Repair and/or replace       Report Generated
                         of cooler           as necessary.
                         Excess Emissions
Broken support beam      Excess Emissions    Shut down and inspect for          Malfunction
                                             broken beam. Repair and/or         Report Generated
                                             replace as necessary.
Bearing failure          Loss of drive       Shut down and inspect              Malfunction
                         shaft               bearing. Repair and/or             Report Generated
                         Excess Emissions    replace as necessary.
Failure of adjustable    Excess Emissions    Inspect drive to determine         Malfunction
frequency drive                              cause of failure. Repair           Report Generated
                                             and/or replace as necessary.
Failure of drive gear    Excess Emissions    Shut down and inspect              Malfunction
reducer                                      reducer to determine cause of      Report Generated
                                             failure. Repair and/or replace
                                             as necessary.
Motion indicator         Excess Emissions    Inspect indicator and/or shut      Malfunction
failure                                      down cooler, as necessary.         Report Generated
                                             Repair and/or replace as
                                             necessary.
Motor failure          Loss of power to Shut down and inspect motor        Malfunction
                       cooler drive       to determine cause of failure.   Report Generated
                       Excess Emissions Repair and/or replace as
                                          necessary.
PLC failure            Shut down of       Inspect to determine cause of    Malfunction
                       cooler             failure. Repair as necessary.    Report Generated
                       Excess Emissions
Failure of DC drive    Excess Emissions Shut down and inspect drive        Malfunction
                                          to determine cause of failure.   Report Generated
                                          Repair and/or replace as
                                          necessary.
Loss of wire(s)        Excess Emissions Inspect to determine cause of
                                          failure. Shut down cooler as
                                          necessary. Repair and/or
                                          replace wire(s), as necessary.
Clinker cooler drives  Shut down of       Inspect to determine cause of    Malfunction
failure                cooler and/or kiln failure and repair and/or        Report Generated
                       Excess Emissions replace as necessary.
Cooler clinker breaker Slowing or         Inspect to determine cause of    Malfunction
failure                stopping kiln      failure and repair and/or        Report Generated
                       Excess Emissions replace as necessary.
Clinker bucket         Shut down of kiln Inspect to determine cause of     Malfunction
elevators failure      Excess Emissions failure and repair and/or          Report Generated
                                          replace as necessary.
Clinker tunnel         Shut down of kiln Inspect to determine cause of     Malfunction
conveyors failure      Excess Emissions failure and repair and/or          Report Generated
                                          replace as necessary.
Lube system failure    Excess Emissions Inspect to determine cause of      Malfunction
                                          failure and repair and/or        Report Generated
                                          replace as necessary.
Water spray system     Excess Emissions Inspect to determine cause of      Malfunction
failure                                   failure and repair and/or        Report Generated
                                          replace as necessary.
Plant air failure      Excess Emissions Inspect to determine cause of      Malfunction
                                          failure and repair and/or        Report Generated
                                          replace as necessary.