OFFER &TECHNICAL SUBMITTAL
5 CU.M/DAY Reverse Osmosis Unit
ESPECIALLY PREPARED FOR
chuckecheesessa's
Hall Project
KINGDOM OF SAUDI ARABIA
PROPOSAL NO. 10-282-17-PR
DATE OF ISSUE: 29Aug,2017
1
INTRODUCTION
We are pleased to introduce ourselves "MIRAS Trading Est.” (Water Works), as a well-
established National Company based in Riyadh, and having diversified field of activities
specializes in Water & Wastewater Treatment. Our water and wastewater treatment division
represents a group of leading companies, from Europe and U.S.A. (enclosed representation).
We specialize in the field of Design, Engineering, Fabrication, Supply, Installation, Start-up,
Commissioning, Trouble shooting and Maintenance of water, Sewage and industrial
wastewater treatment plants and equipment.
Our scope covers the following but not limited to equipment and plants:
1. Reverse Osmosis Plants (Brackish & Seawater applications).
2. Pressure & Cartridge Filtration System (Domestic & Industrial applications).
3. Water Softening System (Domestic & Industrial applications)
4. Demineralization Systems (Domestic & Industrial applications).
5. Chlorination & Disinfection System.
6. Ozonation & UV - Sterilization equipment.
7. Surface Water Treatment.
8. Pollution Control of Municipality and Potable Water.
9. Custom designed water treatment plants.
10. Mobile & Containerized water treatment plants.
11. Instrumentation Controls.
12. Booster pumping Sets & Fire Fighting Pumps.
MIRAS welcomes this opportunity to propose the following equipment described in this
proposal and trust that your decision will be to use the resources provided by Miras's total
capability.
2
Process & Equipment Description :
Miras Plant consists of the following equipment:
1- Pretreatment filtration system:
The filtration system is provided to purify the water from the suspended
particles in the feed water and it gives an extra advantage of protecting the
Reverse Osmosis membranes.
This system is composed of one filter feed pump which is designed to pump the
required capacity of water and required pressure to feed the RO unit.
Water will pass through sand filter then cartridge filter which is fixed
downstream the sand filter to provide more purification for water.
The silt density index (SDI) will measure less than 3 in this stage, which is a
requirement for the RO unit.
2-Pretreatment:
- Anti-scalent is chemical, which should be dosed by dosing pump prior to the
RO membranes to protect the membranes from carbonate and sulfate scaling.
3-Reverse Osmosis (RO) Unit:
This is the heart of the plant where the dissolved salts are separated from the
feed water to produce the permeate water. A high-pressure pump (St.St 316 )
selected carefully for Brackish water with suitable operating parameters will
pump the water with a specific pressure to the membranes which are
assembled in reinforced fiber glass vessel .
Water will leave the membranes in two streams. The permeate stream will be
collected in the product water tank and the reject stream will be disposed to a
proper drainage system. The ratio of permeate water flow to the feed water
flow is called the recovery of the system.
3
4-Instrumentation:
R.O Plant is furnished with measuring devices and monitoring meters to allow
the system to operate with more automatic mode, gives the main readings, and
alarms necessary for the operator and for the protection of the plant. The
operator task is to record these data and match with the plant readings
according to the start up data at the time of commissioning and watch the
signals given so that he can do the required action.
This is in addition to his usual routine duty like filling up the chemicals,
backwash the filters and other works as explained in the operation sheet. These
instruments include TDS Meter, flow meters and Pressure gauges to indicate the
malfunctioned parameter like low & high level switches, and others.
5- Post Treatment chemicals:
The permeate water is further treated according to the customer required uses
Chlorine is added by dosing pump for disinfecting.
*The chemical pumps are Germany made and materials are Teflon and Kynar.
The plant contains other features and it is a high quality system designed for the
customer satisfaction.
4
6- Design & Operating Data of the R.O. Plant
Feed water T.D.S : < 700ppm ( From Tap )
Permeate water T.D.S : <50ppm
Product Flow Rate : 0.208L / Hr ( 5 M3/Day )
Raw Water Temp. : 25 – 350C
Free Chlorine (to : Nil
membrane)
H2S : Nil
Iron : < 0.05 ppm
Electric : 220. - 60Hz
5
7- EQUIPMENT SPECIFICATIONS
ITEM DETAILS SPECIFICATIONS QTY.
NO.
1 Horizontal Feed Pressure Pump 1.375 m3/hr & 3 Bar 2
Brand : Grundfos& Lowara
2 Chemical Dosing System with 2 L/Hr 2
Chemical Tank (Prominent – Germany)
- Anti Scalant Set
- Post Chlorination Set
3 Plastic Filter with Sediment Origin : USA 2
Cartridges 5 micron 20" L
4 UV Unit ( 5 GPM ) Brand : Sterilight 1
- Stainless Steel Origin : Canada
5 High Pressure Pump St.St. 316 1.375 M3/h @ 8 Bar 1
Brand : DP & Lowara
6 Membrane Vessel 4" Dia x 1 Element 1
Codeline
7 RO Membrane 4" Dia x 40" 1
Origin : USA Brand : Filmtec &
Hydranautics
8 TDS Meter ( Product Line ) 0-999 ppm 1
9 Flow Meter Product & Reject 1+1
10 Pressure Gauges 0-6 Bar ( 3 Pcs) Glycerin Filled Lot
0-16 Bar (3 Pcs)
11 Control Panel Complete with all 220 -60 Hz 1
accessories.
* Visible Alarms for :
- Pressure Pumps Fault
- water tanks
full & Empty and others
6
9-Exclusions:
1- Raw water temperature should not exceed 40 C0.
2- Supply of consumables or chemicals after commissioning period 15 Days)
3- Piping or electrical supply or any works outside the plant room.
4- The quotation dose not includes treatment of oil if there are any content
in the water.
5- Power supply should be connected to our RO Control Panel
6- Plant room should have (A) feed, product and drainage lines (B) Power
Box. (C) Air Condition
7
Equipment Specifications
1- U. V Unit :
Qty. : One
Mode of adjustment : automatically start up with the RO Unit
Material : St.Steel
Capacity : 5G/M
Voltage : 220 V
Brand & Origin : Sterilight & Canada
8
2- Filter Feed & Backwash Pumps:
Quantity : Two ( 1 Duty & 1 St. By )
Type : Vertical , Multistage
Total Flow : 1.375 M3 / Hr @ 3-4 Bar
Brand : Grundfos & Lowara
Material of construction
Chamber : Stainless Steel
Impeller : Stainless Steel
Shaft : Stainless Steel
Voltage : 220 – 60 Hz
Accessories : Pressure Gauge, Pipes
Protection : IP 54
9
3- Scale Inhibitor Dosing System
Quantity : One
Type of Pump : Positive Displacement Electronic Diaphragm
Mode of adjustment : Manually adjusted with and automatically start
up with the RO Unit
Material : P.P & Kynar
Capacity : 0.2- 3.9 L/Hr
Voltage : 220 V
Power : 10W
Tank : Vertical, cylindrical 100 L
Tank Qty. : One
Accessories : Inlet and outlet tubing & Foot valve assembly &
Injection valve
Brand & Origin : Prominent & Germany
10
4-Sediment Filter:
Quantity : Two
Material of Housing : Plastic
Model : 1 X 20" Ht.
Origin : USA
Material of Candles : Polypropylene
Length of Cartridge : 20 inches
Number of Cartridge : One
Filtration Size : 5 Micron
11
5- High Pressure Pump
Quantity : One
Type : Vertical , Multistage
Capacity : 1.375 M3 / Hr @ 8 Bar
(Due to complete water analysis)
Speed : 3500 rpm
Material of construction
Body : Stainless Steel 316
Impeller : Stainless Steel 316
Shaft : Stainless Steel 316
Voltage : 220/380 V– 3ph – 60 Hz
Accessoires : Pressure Gauge, Pipes
Protection : IP 54
12
6- Reverse Osmosis Unit:
6.1- Membranes:
Membrane Type : Thin film composite polyamide
Spiral wound for brackish water
Membrane Brand : Filmtec & Hydranautics
Membrane Quantity : 1 Membranes
Membrane Size 4” Dia x 40” Length
6.2- Pressure Vessels
Vessel Body : Glass Fiber Epoxy Resin
Brand : CodeLine
Quantity : 1 Vessels
Stage : (1 V X 1 Elements)
Pressure : 300 PSI
Temperature : <450 C
Feed tube (High Pressure) : Stainless Steel 316
Product tube (L. Pressure) : UPVC Schedule 80
Accessories : Fittings, Sample Valves
13
7- Measuring and Control Devices
Pressure Gauge : 1 Indication range 0-10 bar for filter feed / backwash
(Liquid Filled) pumps outlet.
: 1 Indication range 0-10 bar for Sand Filter
: 1 Indication range 0-10 bar for Carbon Filter
: 1 Indication range 0-10 bar for Sediment Filter
: 2 (1 for each unit) Indication range 0-25 bars for high
pressure pump outlet
: 4 (2 for each unit) Indication range 0-25 bars for control
of the pressure preceding.
Rota meter : 2 (For measuring the permeate and reject water
(Flow Meter) indication
LPS : 1 In Feed Water
TDS Meter : 1 With sensor in permeate line
14
9 - Control Panel:
Qty: One with following specs. :
- Floor mounted control panel completely assembled.
- Panel is fabricated in steel sheets.
- Panel is complete with all fuses, selector switches, contactors, relays,
indicating lights, timers, etc.
- Accessories:
Main Circuit Breaker
Control circuit
Overload relay
Shutdown circuit for: dry run and motor overload
Starters for drives
Plant running
- Major Accessories : Telemechanic
- Visible Signal Lights for :
Filter feed / backwash pumps operation
Filter feed / backwash pumps fault
High pressure pump operation / Fault
Product Water Tank Full
Feed Water Tank Empty
Others
15
10- Internal Piping, Fittings, Valves
Consisting of all necessary piping, fittings and valves with the scope of
supply inside plant room
Internal Piping, Fittings
Material :
Low Pressure Piping : UPVC Sch 80
High pressure Piping : SS 316
Permeate Line : UPVC Sch 80
Reject line piping : UPVC Sch 80
11- Electrical Cabling
Scope of supply:
Consisting of all necessary cabling within the supplied equipment’s inside the
RO- Plant room.
Main cable will be supplied to our RO control panel by client.
12- Battery Limits
From suction line of feed pumps & drain line from sand filter
To reject and product line within the plant room
16
13-Plant Price (5 M3/Day):
24,000.00 ( Twenty For Thousand Only )
The Price Included 1000L Storage Tank & Automatic transfer Pump
-Delivery Period:
2 Weeks from receiving down payment.
- Installation Period:
1days from receiving delivery payment after delivery period if site is ready.
-Payment Terms:
50 % against Order
50 % against Installation and Commissioning
17