5 CU.M/Day RO Unit Proposal KSA

This document provides specifications for a 5 cubic meter per day reverse osmosis water treatment unit. The system includes pretreatment filtration with sand and cartridge filters, a reverse osmosis unit with high-pressure pump and spiral wound polyamide membranes, and post-treatment disinfection with UV and chlorine dosing. Detailed specifications are provided for the equipment, including the filters, pumps, dosing systems, controls, and membranes. Exclusions from the proposal and requirements for installation are also listed.

Uploaded by

Zeyad Eltobgy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
193 views17 pages

5 CU.M/Day RO Unit Proposal KSA

This document provides specifications for a 5 cubic meter per day reverse osmosis water treatment unit. The system includes pretreatment filtration with sand and cartridge filters, a reverse osmosis unit with high-pressure pump and spiral wound polyamide membranes, and post-treatment disinfection with UV and chlorine dosing. Detailed specifications are provided for the equipment, including the filters, pumps, dosing systems, controls, and membranes. Exclusions from the proposal and requirements for installation are also listed.

Uploaded by

Zeyad Eltobgy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

OFFER &TECHNICAL SUBMITTAL

5 CU.M/DAY Reverse Osmosis Unit

ESPECIALLY PREPARED FOR


chuckecheesessa's
Hall Project

KINGDOM OF SAUDI ARABIA

PROPOSAL NO. 10-282-17-PR

DATE OF ISSUE: 29Aug,2017

1
INTRODUCTION
We are pleased to introduce ourselves "MIRAS Trading Est.” (Water Works), as a well-
established National Company based in Riyadh, and having diversified field of activities
specializes in Water & Wastewater Treatment. Our water and wastewater treatment division
represents a group of leading companies, from Europe and U.S.A. (enclosed representation).

We specialize in the field of Design, Engineering, Fabrication, Supply, Installation, Start-up,


Commissioning, Trouble shooting and Maintenance of water, Sewage and industrial
wastewater treatment plants and equipment.

Our scope covers the following but not limited to equipment and plants:

1. Reverse Osmosis Plants (Brackish & Seawater applications).


2. Pressure & Cartridge Filtration System (Domestic & Industrial applications).
3. Water Softening System (Domestic & Industrial applications)
4. Demineralization Systems (Domestic & Industrial applications).
5. Chlorination & Disinfection System.
6. Ozonation & UV - Sterilization equipment.
7. Surface Water Treatment.
8. Pollution Control of Municipality and Potable Water.
9. Custom designed water treatment plants.
10. Mobile & Containerized water treatment plants.
11. Instrumentation Controls.
12. Booster pumping Sets & Fire Fighting Pumps.

MIRAS welcomes this opportunity to propose the following equipment described in this
proposal and trust that your decision will be to use the resources provided by Miras's total
capability.

2
Process & Equipment Description :

Miras Plant consists of the following equipment:

1- Pretreatment filtration system:

The filtration system is provided to purify the water from the suspended
particles in the feed water and it gives an extra advantage of protecting the
Reverse Osmosis membranes.
This system is composed of one filter feed pump which is designed to pump the
required capacity of water and required pressure to feed the RO unit.
Water will pass through sand filter then cartridge filter which is fixed
downstream the sand filter to provide more purification for water.
The silt density index (SDI) will measure less than 3 in this stage, which is a
requirement for the RO unit.

2-Pretreatment:

- Anti-scalent is chemical, which should be dosed by dosing pump prior to the


RO membranes to protect the membranes from carbonate and sulfate scaling.

3-Reverse Osmosis (RO) Unit:

This is the heart of the plant where the dissolved salts are separated from the
feed water to produce the permeate water. A high-pressure pump (St.St 316 )
selected carefully for Brackish water with suitable operating parameters will
pump the water with a specific pressure to the membranes which are
assembled in reinforced fiber glass vessel .
Water will leave the membranes in two streams. The permeate stream will be
collected in the product water tank and the reject stream will be disposed to a
proper drainage system. The ratio of permeate water flow to the feed water
flow is called the recovery of the system.

3
4-Instrumentation:

R.O Plant is furnished with measuring devices and monitoring meters to allow
the system to operate with more automatic mode, gives the main readings, and
alarms necessary for the operator and for the protection of the plant. The
operator task is to record these data and match with the plant readings
according to the start up data at the time of commissioning and watch the
signals given so that he can do the required action.
This is in addition to his usual routine duty like filling up the chemicals,
backwash the filters and other works as explained in the operation sheet. These
instruments include TDS Meter, flow meters and Pressure gauges to indicate the
malfunctioned parameter like low & high level switches, and others.

5- Post Treatment chemicals:


The permeate water is further treated according to the customer required uses
Chlorine is added by dosing pump for disinfecting.
*The chemical pumps are Germany made and materials are Teflon and Kynar.
The plant contains other features and it is a high quality system designed for the
customer satisfaction.

4
6- Design & Operating Data of the R.O. Plant

Feed water T.D.S : < 700ppm ( From Tap )

Permeate water T.D.S : <50ppm

Product Flow Rate : 0.208L / Hr ( 5 M3/Day )

Raw Water Temp. : 25 – 350C

Free Chlorine (to : Nil


membrane)

H2S : Nil

Iron : < 0.05 ppm

Electric : 220. - 60Hz

5
7- EQUIPMENT SPECIFICATIONS

ITEM DETAILS SPECIFICATIONS QTY.


NO.
1 Horizontal Feed Pressure Pump 1.375 m3/hr & 3 Bar 2
Brand : Grundfos& Lowara
2 Chemical Dosing System with 2 L/Hr 2
Chemical Tank (Prominent – Germany)
- Anti Scalant Set
- Post Chlorination Set
3 Plastic Filter with Sediment Origin : USA 2
Cartridges 5 micron 20" L
4 UV Unit ( 5 GPM ) Brand : Sterilight 1
- Stainless Steel Origin : Canada
5 High Pressure Pump St.St. 316 1.375 M3/h @ 8 Bar 1
Brand : DP & Lowara
6 Membrane Vessel 4" Dia x 1 Element 1
Codeline
7 RO Membrane 4" Dia x 40" 1
Origin : USA Brand : Filmtec &
Hydranautics
8 TDS Meter ( Product Line ) 0-999 ppm 1
9 Flow Meter Product & Reject 1+1
10 Pressure Gauges 0-6 Bar ( 3 Pcs) Glycerin Filled Lot
0-16 Bar (3 Pcs)
11 Control Panel Complete with all 220 -60 Hz 1
accessories.
* Visible Alarms for :
- Pressure Pumps Fault
- water tanks
full & Empty and others

6
9-Exclusions:

1- Raw water temperature should not exceed 40 C0.


2- Supply of consumables or chemicals after commissioning period 15 Days)
3- Piping or electrical supply or any works outside the plant room.
4- The quotation dose not includes treatment of oil if there are any content
in the water.
5- Power supply should be connected to our RO Control Panel
6- Plant room should have (A) feed, product and drainage lines (B) Power
Box. (C) Air Condition

7
Equipment Specifications

1- U. V Unit :

Qty. : One

Mode of adjustment : automatically start up with the RO Unit

Material : St.Steel

Capacity : 5G/M

Voltage : 220 V

Brand & Origin : Sterilight & Canada

8
2- Filter Feed & Backwash Pumps:

Quantity : Two ( 1 Duty & 1 St. By )


Type : Vertical , Multistage

Total Flow : 1.375 M3 / Hr @ 3-4 Bar

Brand : Grundfos & Lowara

Material of construction
Chamber : Stainless Steel
Impeller : Stainless Steel

Shaft : Stainless Steel

Voltage : 220 – 60 Hz

Accessories : Pressure Gauge, Pipes

Protection : IP 54

9
3- Scale Inhibitor Dosing System

Quantity : One

Type of Pump : Positive Displacement Electronic Diaphragm

Mode of adjustment : Manually adjusted with and automatically start


up with the RO Unit

Material : P.P & Kynar

Capacity : 0.2- 3.9 L/Hr

Voltage : 220 V

Power : 10W

Tank : Vertical, cylindrical 100 L

Tank Qty. : One

Accessories : Inlet and outlet tubing & Foot valve assembly &
Injection valve

Brand & Origin : Prominent & Germany

10
4-Sediment Filter:

Quantity : Two

Material of Housing : Plastic

Model : 1 X 20" Ht.

Origin : USA

Material of Candles : Polypropylene

Length of Cartridge : 20 inches

Number of Cartridge : One

Filtration Size : 5 Micron

11
5- High Pressure Pump

Quantity : One
Type : Vertical , Multistage

Capacity : 1.375 M3 / Hr @ 8 Bar


(Due to complete water analysis)

Speed : 3500 rpm

Material of construction
Body : Stainless Steel 316
Impeller : Stainless Steel 316

Shaft : Stainless Steel 316

Voltage : 220/380 V– 3ph – 60 Hz

Accessoires : Pressure Gauge, Pipes

Protection : IP 54

12
6- Reverse Osmosis Unit:

6.1- Membranes:

Membrane Type : Thin film composite polyamide


Spiral wound for brackish water
Membrane Brand : Filmtec & Hydranautics
Membrane Quantity : 1 Membranes
Membrane Size 4” Dia x 40” Length

6.2- Pressure Vessels

Vessel Body : Glass Fiber Epoxy Resin


Brand : CodeLine
Quantity : 1 Vessels
Stage : (1 V X 1 Elements)
Pressure : 300 PSI
Temperature : <450 C
Feed tube (High Pressure) : Stainless Steel 316
Product tube (L. Pressure) : UPVC Schedule 80
Accessories : Fittings, Sample Valves

13
7- Measuring and Control Devices

Pressure Gauge : 1 Indication range 0-10 bar for filter feed / backwash
(Liquid Filled) pumps outlet.

: 1 Indication range 0-10 bar for Sand Filter


: 1 Indication range 0-10 bar for Carbon Filter
: 1 Indication range 0-10 bar for Sediment Filter
: 2 (1 for each unit) Indication range 0-25 bars for high
pressure pump outlet
: 4 (2 for each unit) Indication range 0-25 bars for control
of the pressure preceding.

Rota meter : 2 (For measuring the permeate and reject water


(Flow Meter) indication

LPS : 1 In Feed Water

TDS Meter : 1 With sensor in permeate line

14
9 - Control Panel:
Qty: One with following specs. :
- Floor mounted control panel completely assembled.
- Panel is fabricated in steel sheets.
- Panel is complete with all fuses, selector switches, contactors, relays,
indicating lights, timers, etc.
- Accessories:
 Main Circuit Breaker
 Control circuit
 Overload relay
 Shutdown circuit for: dry run and motor overload
 Starters for drives
 Plant running
- Major Accessories : Telemechanic

- Visible Signal Lights for :


 Filter feed / backwash pumps operation

 Filter feed / backwash pumps fault

 High pressure pump operation / Fault

 Product Water Tank Full

 Feed Water Tank Empty

 Others

15
10- Internal Piping, Fittings, Valves

Consisting of all necessary piping, fittings and valves with the scope of
supply inside plant room

Internal Piping, Fittings

Material :
 Low Pressure Piping : UPVC Sch 80
 High pressure Piping : SS 316
 Permeate Line : UPVC Sch 80
 Reject line piping : UPVC Sch 80

11- Electrical Cabling

Scope of supply:

Consisting of all necessary cabling within the supplied equipment’s inside the
RO- Plant room.
Main cable will be supplied to our RO control panel by client.

12- Battery Limits


 From suction line of feed pumps & drain line from sand filter
 To reject and product line within the plant room

16
13-Plant Price (5 M3/Day):

24,000.00 ( Twenty For Thousand Only )


The Price Included 1000L Storage Tank & Automatic transfer Pump

-Delivery Period:

2 Weeks from receiving down payment.

- Installation Period:

1days from receiving delivery payment after delivery period if site is ready.

-Payment Terms:

50 % against Order
50 % against Installation and Commissioning

17