Vendor Supplied
Document
                        Contents:
                        Hardware Installation Manual
                        ABB RDCO-01/02/03 DDCS Communication Option Modules
                        ABB Manual # 3AFE-64492209 REV A
                        Effective: March 1, 2002
THIS DOCUMENT CONTAINS PROPRIETARY AND CONFIDENTIAL INFORMATION WHICH BELONGS
TO NATIONAL-OILWELL, L.P. IT IS LOANED FOR LIMITED PURPOSES ONLY AND REMAINS THE
PROPERTY OF NATIONAL-OILWELL, L.P. REPRODUCTION, IN WHOLE OR IN PART OR USE OF
THIS DESIGN OR DISTRIBUTION OF THIS INFORMATION TO OTHERS IS NOT PERMITTED WITHOUT
THE EXPRESS WRITTEN CONSENT OF NATIONAL-OILWELL, L.P. THIS DOCUMENT IS TO BE
RETURNED TO NATIONAL-OILWELL, L.P. UPON REQUEST AND IN ANY EVENT UPON COMPLETION
OF THE USE FOR WHICH IT WAS LOANED. THIS DOCUMENT AND THE INFORMATION CONTAINED
AND REPRESENTED IS THE COPYRIGHTED PROPERTY OF NATIONAL-OILWELL, L.P.
                                                                                     TITLE                      Vendor Supplied Document
                        CURRENT                             INITIAL
DRAWN                                                                                  ABB RDCO-01/02/03 DDCS Communication
                                                           Jane Kellstrom
CHECKED
                                                                                          Option Modules, Installation Manual
                                                           John R. Moffitt
                                                                                      SIZE    DWG NO                                                    REV
APPVD
                                                               Hyoung Lim              A                        3VDR00175                                -
DATE
                                                            Sept 13, 2006            SCALE   1/1       WT LBS     N/A          SHEET       1   OF   3
                                                                                                                                           DCF0045 (REV B)
RDCO-01/02/03                                                      Module layout
DDCS Communication
Option Modules                                                                                CH 0
                                                                                      GND
                                                                                              CH 1
Overview                                                                Fixing                            Fibre optic channels
The RDCO-0x DDCS Communication Options are add-on                      screws
                                                                                              CH 2
modules for the RMIO Motor Control and I/O Board, used in
ACS 800 family frequency converters. RDCO modules are
available factory-installed as well as retrofit kits.
                                                                                      CHGND   CH 3
The RDCO module includes the connectors for fibre optic
DDCS channels CH0, CH1, CH2 and CH3. The usage of these
channels is determined by the application program; see the
Firmware Manual of the drive. However, the channels are
normally assigned as follows:
CH0 – overriding system (e.g. fieldbus adapter)                    Installation
CH1 – I/O extensions                                                             WARNING! All electrical installation and
CH2 – Master/Follower link                                                       maintenance work on the drive should be carried
CH3 – PC tools (such as DriveWare).                                              out by qualified electricians only.
There are several types of the RDCO. The difference between                    The drive and adjoining equipment must be
the types is the optical components. In addition, each type is     properly earthed.
available with a coated circuit board, this being indicated by a
“C” suffix, e.g. RDCO-03C.                                         Do not work on a powered drive. Before installation, switch off
                                                                   the mains and other dangerous voltages (e.g. from external
                            Optical Component Type                 control circuits) to the drive. After switching off the mains,
    Module Type                                                    always allow the intermediate circuit capacitors 5 minutes to
                     CH0        CH1         CH2         CH3        discharge before starting work on the frequency converter. It is
                                                                   a good practice to check (with a voltage indicating instrument)
    RDCO-01(C)     10 MBd      5 MBd       10 MBd     10 MBd
                                                                   that the drive is in fact discharged before beginning work.
    RDCO-02(C)      5 MBd      5 MBd       10 MBd     10 MBd       There may be dangerous voltages inside the drive from
                                                                   external control circuits even when the drive mains power is
    RDCO-03(C)      5 MBd      5 MBd       5 MBd       5 MBd
                                                                   shut off. Exercise appropriate care when working on the unit.
                                                                   Neglecting these instructions may cause physical injury or
The optical components at both ends of a fibre optic link must
                                                                   death.
be of the same type for the light intensity and receiver
sensitivity levels to match. Plastic optical fibre (POF) cables               WARNING! The component boards of the drive
can be used with both 5 MBd and 10 MBd optical components.                    contain integrated circuits that are extremely
10 MBd components also enable the use of Hard Clad Silica                     sensitive to electrostatic discharge (ESD). Wear
(HCS) cables, which allow longer connection distances thanks                  an earthing wrist band when handling component
to their lower attenuation.                                                   boards. Do not touch the boards unnecessarily.
                                                                   Do not remove any board from its antistatic packaging until
                                                                   required.
Note: The optical component type does not reflect the actual
                                                                                WARNING! Handle the fibre optic cables with
communication speed.
                                                                                care. The maximum long term tensile load is 1 N;
                                                                                the minimum short term bend radius is 35 mm.
                                                                                Do not touch the ends of the fibres with bare
Delivery check                                                                  hands as the fibre is extremely sensitive to dirt.
                                                                   Use rubber grommets at cable entries to protect the cables.
The option package contains:
•     RDCO-0x module                                               The RDCO-0x module is to be inserted into the position
•     Two screws (M3×8)                                            marked “DDCS” on the drive. On installation, the signal and
•     This document.                                               power connection to the drive (RMIO board) is automatically
                                                                   made through a 20-pin connector.
Compatibility                                                      The module is held in place with plastic retaining clips and two
                                                                   screws. The screws also provide the earthing of module, and
The RDCO-0x is compatible with the motor control and I/O           interconnect the GND signals of the module and the RMIO
board (RMIO) of the ACS 800.                                       board.
                                                                                                          (continued overleaf)
Installation Procedure                                                    Connectors:
1.   Access the optional module slots on the drive. Whenever              •   20-pin pinheader
     necessary, refer to the Hardware Manual of the drive for             •   4 transmitter/receiver connector pairs for fibre optic cable.
     instructions on removing any covers.                                     Type: Agilent Technologies Versatile Link. Communication
2.   Insert the module carefully into the slot marked “DDCS”                  speed: 1, 2 or 4 Mbit/s
     on the RMIO board until the retaining clips lock the                 Operating voltage: +5 V DC ±10%, supplied by the RMIO
     module into position.                                                board of the drive
3.   Fasten the screws included in the package. Note that                 Current consumption: 200 mA max.
     correct installation of the screws is essential for fulfilling
     the EMC requirements and for proper operation of the                 Electromagnetic immunity: IEC 1000-4-2 (limits: industrial,
     module.                                                              second environment); IEC 1000-4-3; IEC 1000-4-4;
                                                                          IEC 1000-4-6
4.   Lead the fibre optic cables from the external device to the
     appropriate channel(s) of the RDCO. Inside the drive,                Electromagnetic emissions: EN 50081-2; CISPR 11
     route the cables as shown in its Hardware Manual. Make               Dimensions (mm):
     sure the cables are not kinked or laid against sharp
     edges. Observe colour coding so that transmitters are                         30                           34
     connected to receivers and vice versa. In case multiple
     devices are to be connected to one channel, they must
     be connected in a ring.
Technical data
Module types: RDCO-01(C), RDCO-02(C), RDCO-03(C)
                                                                                                     95
Degree of protection: IP 20
Ambient conditions: The applicable ambient conditions
specified for the drive in its Hardware Manual are in effect.
                                                                                                           20
                                                                                                                               3AFE 64492209 REV A EN
                                                                                                                               EFFECTIVE: 1.3.2002
ABB Oy                                                  ABB Inc.
AC Drives                                               Drives & Power Products
P.O. Box 184                                            16250 West Glendale Drive
FIN-00381 Helsinki                                      New Berlin, WI 53151
FINLAND                                                 USA
                                                                                                                               RDCO-0x
Telephone:     +358 10 22 11                            Telephone:      262 785-8378
Fax:           +358 10 222 2681                                         800 243-4384
Internet:      www.abb.com                              Fax:            262 780-5135