RL201
DC COMPONENTS CO., LTD.
THRU
R
RECTIFIER SPECIALISTS
RL207
TECHNICAL SPECIFICATIONS OF GENERAL PURPOSE SILICON RECTIFIER
VOLTAGE RANGE - 50 to 1000 Volts CURRENT - 2.0 Amperes
FEATURES
* Low cost
* Low leakage
* Low forward voltage drop
* High current capability DO-15
MECHANICAL DATA
.034(0.9)
* Case: Molded plastic DIA.
.028(0.7)
* Epoxy: UL 94V-0 rated flame retardant 1.0(25.4)
MIN.
* Lead: MIL-STD-202E, Method 208 guaranteed
* Polarity: Color band denotes cathode end
* Mounting position: Any .300(7.6)
* Weight: 0.38 gram approx. .230(5.8)
.140(3.6)
DIA.
.104(2.6)
1.0(25.4)
MIN.
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
o
Ratings at 25 C ambient temperature unless otherwise specified.
Single phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
SYMBOL RL201 RL202 RL203 RL204 RL205 RL206 RL207 UNITS
Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 Volts
Maximum RMS Voltage VRMS 35 70 140 280 420 560 700 Volts
Maximum DC Blocking Voltage VDC 50 100 200 400 600 800 1000 Volts
Maximum Average Forward Rectified Current
o IO 2.0 Amps
375"(9.5mm) lead length at T A = 55 C
Peak Forward Surge Current 8.3 ms single half sine-wave
IFSM 70 Amps
superimposed on rated load (JEDEC Method)
Maximum Instantaneous Forward Voltage at 2.0A DC VF 1.1 Volts
o
Maximum DC Reverse Current at Rated @ TA=25 C 5.0
DC Blocking Voltage o
@ TA=100 C 500
IR µAmps
Maximum Full Load Reverse Current Average, Full
o 30
Cycle .375”(9.5mm) lead length at TL = 75 C
Typical Junction Capacitance (Note 1) CJ 20 pF
o
Typical Thermal Resistance (Note 2) RθJ A 40 C/ W
o
Operating and Storage Temperature Range TJ, T STG -55 to +150 C
Note 1: Measured at 1 MHz and applied reverse voltage of 4.0 volts.
Note 2: Typical thermal resistance from junction to ambient.
REV-3,MAY,2017 1 www.dccomponents.com
RATING AND CHARACTERISTIC CURVES (RL201 THRU RL207)
FIG. 1 FIG. 2
TYPICAL FORWARD CURRENT MAXIMUM NON-REPETITIVE FORWARD
DERATING CURVE SURGE CURRENT
PEAK FORWARD SURGE CURRENT, (A)
2.5 100
AVERAGE FORWARD CURRENT, (A)
8.3ms Single Half Sine-Wave
(JEDEC Method)
2.0 80
1.5 60
1.0 40
Single Phase
Half Wave 60Hz
.5 Resistive or 20
Inductive Load
0 0
0 25 50 75 100 125 150 1 2 4 6 8 10 20 40 60 80 100
O
AMBIENT TEMPERATURE, ( C) NUMBER OF CYCLES AT 60Hz
FIG. 3 FIG. 4
TYPICAL INSTANTANEOUS TYPICAL REVERSE CHARACTERISTICS
FORWARD CHARACTERISTICS
20 1000
INSTANTANEOUS FORWARD CURRENT, (A)
10
O
TJ=125 C
INSTANTANEOUS REVERSE CURRENT, (µA)
3.0
100
1.0
O
O TJ=100 C
0.3 TJ=25 C
Pulse Width=300µs
1% Duty Cycle 10
0.1
.03
.01
1
0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8
O
TJ=25 C
INSTANTANEOUS FORWARD VOLTAGE, (V)
.1
0 20 40 60 80 100 120 140
FIG. 5 PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
TYPICAL JUNCTION CAPACITANCE
200
100
JUNCTION CAPACITANCE, (pF)
60
40
20
10
O
TJ=25 C
6
4
2
1
.1 .2 .4 1.0 2 4 10 20 40 100
REVERSE VOLTAGE, (V)
REV-3,MAY,2017 2 www.dccomponents.com
Disclaimer
Any Customer or user of this document or products described herein in such applications shall assume
all risks of such use and will agree to hold DC COMPONENTS are harmless against all damages.
DC COMPONENTS disclaims any and all liability arising out of the application or use of any product, including
consequential or incidental damages. Statement regarding the suitability of products for certain types
of applications are based on DC COMPONENTS ’s knowledge of typical requirements that are often placed
on DC COMPONENTS products in generic applications. Such statements are not binding statements about
the suitability of products for aparticular application. It is the customer's responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular
application.
DC COMPONENTS reserve the right to make modifications, enhancements, improvements, corrections
or other changes without further notice to this document and any product described herein, and disclaim
any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any
other disclosure relating to any product. Parameters provided in datasheets and specifications may
vary in different applications and performance may vary over time. All operating parameters, including
typical parameters, must be validated for each customer application by the customer’s technical experts.
Product specifications do not expand or otherwise modify DC COMPONENTS ’s terms and conditions
of purchase, including but not limited to the warranty expressed therein.
Unless otherwise in writing, DC COMPONENTS products are intended for use as general electronic components
in standard applications ( eg: Consumer electronic, Computer equipment, Office equipment, etc.), and not
recommended for use in a high specific application where a failure or malfunction of the device could result
in human injury or death ( eg: Aerospace equipment, Submarine cables, Combustion equipment, Safety
devices, Life support systems, etc.)
Customers using or selling DC COMPONENTS products not expressly indicated for use in such applications
do so at their own risk. If customer intended to use DC COMPONENTS standard quality grade devices for
applications not envisioned by DC COMPONENTS, please contact our sales representatives in advance.
DC COMPONENTS CO., LTD.
R