PATROL-803PET FEATURES DETECTOR INSTALLATION INSTALLATION
®
PATROL - 803PET The PATROL-803PET is a • HI-TECH DESIGN Fix the detector vertically
LIMITATIONS
combination of PIR and on solid, flat wall surface. • Do not install the detector on
COMBINED acoustic glass break detector. • DUAL TECHNOLOGY The installation height is unstable or vibrating surfaces.
PIR & GLASS PIR & MICROPHONE
The PATROL-803PET is a 2 – 2.5 meters.
BREAK DETECTOR digital passive infrared • Do not install the detector
• HIGH RFI & EMI IMMUNITY For corner or ceiling
WITH PET IMMUNITY detector with dual element close to curtains, blinds or
• DIGITAL PROGRAM installations, you can use other items that vibrate with
UP TO 30KG pyrosensor, which provides
universal brackets – models:
the most efficient security ALGORITHM OF SIGNAL air movement.
INSTALLATION PROCESSING "UBL-1112" or "UBL-1115."
INSTRUCTIONS of residential and industrial • Do not install the detector
(Additional purchase!)
premises. • IMMUNE TO PETS UP TO 30KG close to air conditioners, air
The PIR detector analyzes For corner installation, blast sources or above heat
the environment and detects • TEST MODE FOR TWO use knockouts located on the
ACOUSTIC CHANNELS sources.
the person's motion crossing sloping part of the detector
the infrared beam. • INDIVIDUAL PIR SENSITIVITY base. • Do not install the detector
The acoustic glass break ADJUSTMENT or route power wires and
For protecting several
detector identifies the sounds alarm loops next to high
• HIGH LIGHT IMMUNITY windows, mount the detector
of glass impact and breakage. voltage cables.
at optimal distance from them.
Two independent optoelectronic • HERMETICALLY SEALED If heavy blinds of curtains
relays of the PIR and glass break PYROELECTRIC SENSOR cover the glass, locate the
detectors, allow connecting the detector so the blinds will not
detectors to two independent • LOW OPERATING
TEMPERATURE block the sound.
zones in the control panel.
The detector ignores pets of • AUTOMATIC TEMPERATURE
up to 30kg and 1m height. COMPENSATION
1 2 3 4 5
TERMINAL BLOCK DETECTOR ADJUSTMENT LED INDICATION ON SELECTING COVERAGE
CONNECTION ALARM. RANGE
1. Remove the front cover. + 12V TAMPER RELAY 1 RELAY 2
Connect the wires according 2. Set regulator S2
LED LED
Set the jumper W2 according
to the scheme. (PET IMMUNITY) according to ON ON
J1 to the distance to the
OFF OFF
animal weight. protected glass.
+ 12V - TAMPER RELAY 1 RELAY 2 W3 W3 C18
GLASS
ACOUSTIC 6m
SENSITIVITY
+
D4
30KG S1
S2 20KG
Jumper W3 will enable/disable LED
R17
RANGE 9m
ADJUSTMENT 12m
10KG the alarm LED.
W3 PATROL SHOCK &
GLASS TEST W2
Terminals “+12V-“ - for If W3 is ON – LED will operate 803PET OPERATING
3. Connect the power and PET
MODE
PROTECTED GLASS TYPES
connection to the power supply on alarm. 30KG
GLASS TEST
wait for LED to stop flashing W1
of the control unit. If W3 OFF – LED will
20KG
Min. Max.
(warm-up time 60 sec). 10KG
ACOUSTIC
Glass Type
Thickness Thickness
Terminals “Tamper” - for 4. Replace the cover. not operate on alarm. S2
PIR
RANGE
ADJUSTMENT
Plate 2 mm 14 mm
SENSITIVITY
6M
connection to a 24-hour
+
5. Pass in the field of view W2 9M Tempered 3 mm 10 mm
normally closed protective zone detector. The RED LED
R18
12M Patterned 3 mm 12 mm
in the control unit. should actively respond to your
Laminated¹ 3.2 mm 14.3mm
Wired¹ 5 mm 6.4 mm
Terminals “Relay 1”- relay movement. Coated (Triplex)¹ 2.5 mm 8.4 mm
output of the PIR detector. 6. If necessary, increase the W1 – Jumper to select operating Sealed insulating¹ 3.2 mm 6.4 mm
and test modes
detector PIR sensitivity,
Terminals “Relay 2”- relay W2 – Acoustic range adjustment ¹The detection range of the
using R18 potentiometer
output of the glass break acoustic glass break detector
“PIR Sensitivity”. S2 – Animal weight regulator
detector. is reduced up to 10 meters for
PIR
SENSITIVITY R17 – Glass sensitivity regulator the following glass types:
+
R18 – PIR sensitivity regulator Laminated, Wired, Coated
R18 S1 – Tamper button (Triplex), Sealed Insulating.
6 7 8 9 10
GLASS BREAK TEST SHOCK & GLASS BREAK WIDE ANGLE LENS. VERTICAL BARRIER LENS LONG RANGE LENS
(ADJUSTMENT) TEST
TOP VIEW
1. Set the jumper W1 to the 1. Set the jumper W1 to 10m
“GLASS TEST “position. "SHOCK & GLASS TEST" (33ft)
position.
1m
SHOCK & GLASS
12.5m
TEST
(41ft)
OPERATING SHOCK & GLASS
MODE TEST 5m
GLASS TEST OPERATING (16ft)
W1 MODE
GLASS TEST
The PIR detector is off; W1
The RELAY 1 and RELAY 2 The PIR detector is off; 0 120°
are opened.
The RELAY 1 is opened.
2. Replace the cover. The RELAY 2 is closed.
3. Use glass break simulator to 2. Replace the cover. 5m
(2.6ft) (5.3ft) (11ft)
0.8m 1.6m 3.4m
SIDE VIEW
(16ft)
simulate the high frequency
TOP VIEW
signal of the glass breakage. 3. Tap gently the protected
The red LED will flash with glass and activate the glass
each simulator activation. break simulator at the same 10m
time. The relay output of (33ft)
4. Use the trimmer R17 marked
0.9m
0.9m
(3ft)
(3ft)
2.4m
SIDE VIEW
(8ft)
the glass break detector
0
“GLASS SENSITIVITY” to adjust 2.3m
will open for 3 sec. (7.5ft)
in detector with more sensitivity.
The red LED will be ON.
GLASS
SENSITIVITY 4. After testing, set the jumper 0m 1.6m 3.8m 7m 10.7m
(0ft) (5.5ft) (12.5ft) (23ft) (35ft)
15.6m
(51ft)
+
W1 to the “OPERATING
R17 MODE” position. *ADDITIONAL PURCHASE *ADDITIONAL PURCHASE
11 12 13 14 15
UNIVERSAL BRACKET SUNSHIELD FILTER TECHNICAL Light immunity without sunshield WARRANTY
MODELS: SPECIFICATIONS filter:………....no less than 6500lux
GSN Electronic Company Ltd.
“UBL-1112”, “UBL-1115”. Light immunity with sunshield
Input voltage…………….8.5 – 16V warrants the product to be free
filter:………………..more 30000lux from defects in materials and
Current consumption:
Operating temperature workmanship under condition
In standby mode: …………17.7mA
In alarm mode:………………19mА range:……………….– 30°C +60°C of observance of service
regulations and to be repaired
Warm up period:…..………...60sec Storage temperature
or replaced under absence of
range:....................– 50°C – +80°C
PIR detection range:..15.6m x 120º
mechanical damages for a
Sunshield filter for extra RFI immunity: 30V/м limited period of five years
protection of pyroelectric PIR detection speed at a frequency range 30MHz-1GHz from the date of sale.
sensor of detector from range:…………………0.3 – 3m/sec
EMI immunity……………..50,000V
sunlight and car headlights. Glass break detection
range:……….……........12m x 160º Dimensions:………………………... 7 ATARA ST.
……………54mm x 33mm x 99mm NAZARETH ILLIT 17802
Relay output:………………………. P.O.BOX 17719
……….........NC; 60V; 100mA; 16Ω Weight:…………….…………...82gr.
ISRAEL
Tamper output:…………...NC; 10Ω TEL: + (972) 4 6467152
FAX: + (972) 4 6562414
Alarm period:….......................3sec
WWW.GSNCOMPANY.COM
Reset time:………………..5 ± 1sec
6 7 8 9 10
GSN@GSNCOMPANY.COM
PET mode:……………..10/20/30kg
Installation height:……...2.0 – 2.5m
OC03
*ADDITIONAL PURCHASE *ADDITIONAL PURCHASE P/N: USM0EPAT803PET_REV.A
16 17 18 19 20