0% found this document useful (0 votes)
35 views1 page

Overview of Calcualtions: SR - NO. 1 RULE-1 Quantitative Criteria

This document outlines rules for thermowell selection and fluid property collection. Rule 1 specifies quantitative criteria for thermowell resonance frequency, dynamic stress limits, static stress limits, and hydrostatic pressure limits. Rule 2 indicates that the following fluid properties should be collected: operating pressure, operating temperature, process fluid velocity, specific volume, dynamic fluid viscosity, kinematic fluid viscosity, and fluid density.

Uploaded by

Susheel Wankhede
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
35 views1 page

Overview of Calcualtions: SR - NO. 1 RULE-1 Quantitative Criteria

This document outlines rules for thermowell selection and fluid property collection. Rule 1 specifies quantitative criteria for thermowell resonance frequency, dynamic stress limits, static stress limits, and hydrostatic pressure limits. Rule 2 indicates that the following fluid properties should be collected: operating pressure, operating temperature, process fluid velocity, specific volume, dynamic fluid viscosity, kinematic fluid viscosity, and fluid density.

Uploaded by

Susheel Wankhede
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

OVERVIEW

SR.NO.      
1 RULE-1 QUANTITATIVE CRITERIA  
a R1-1 Frequency Limit. The resonance frequency of the thermowell shall be s
b R1-2 Dynamic Stress Limit. The maximum primary dynamic stress shall not excee
c R1-3 Static Stress Limit. The maximum steady-state stress on the thermowell
d R1-4 Hydrostatic Pressure Limit. The external pressure shall not exceed the pressure ra
e R1-4 In addition, the suitability of the thermowell material for the process environment (section 5)
2 RULE-2 FLUID PROPERTIES COLLECT THE FOLLOWING FLUID PROPERTIES
    SYMBOL PARAMETERS
1   P operating pressure, Pa (psi)
2   T operating temperature, °C (°F)
3   V process-fluid velocity, m/s (in./sec)
4   v specific volume (reciprocal of the fluid density ρ),m3/
5   μ dynamic fluid viscosity, Pa⋅s (lbf⋅sec/ft2),
6   ν kinematic fluid viscosity, m2/s (ft2/sec)
7   ρ fluid density, kg/m3 (lb/in.3)