OVERVIEW
SR.NO.                                                       
   1     RULE-1   QUANTITATIVE CRITERIA                      
   a      R1-1    Frequency Limit.                          The resonance frequency of the thermowell shall be s
   b      R1-2    Dynamic Stress Limit.                     The maximum primary dynamic stress shall not excee
   c      R1-3    Static Stress Limit.                      The maximum steady-state stress on the thermowell
   d      R1-4    Hydrostatic Pressure Limit.               The external pressure shall not exceed the pressure ra
   e      R1-4    In addition, the suitability of the thermowell material for the process environment (section 5)
   2     RULE-2   FLUID PROPERTIES                          COLLECT THE FOLLOWING FLUID PROPERTIES
                  SYMBOL                                    PARAMETERS
   1                                   P                    operating pressure, Pa (psi)
   2                                   T                    operating temperature, °C (°F)
   3                                   V                    process-fluid velocity, m/s (in./sec)
   4                                   v                    specific volume (reciprocal of the fluid density ρ),m3/
   5                                   μ                    dynamic fluid viscosity, Pa⋅s (lbf⋅sec/ft2),
   6                                   ν                    kinematic fluid viscosity, m2/s (ft2/sec)
   7                                   ρ                    fluid density, kg/m3 (lb/in.3)