Complies with NF C 17-102 Standard
Who is LPI?                                           LPI Product Offering
Lightning Protection International Pty                Lightning Protection International Pty Ltd offers a comprehensive
Ltd (        ) is a fully owned Australian            range of products and services as part of its complete solution
manufacturer and supplier of direct strike            to your lightning problems. These products cover Direct strike
lightning, surge & transient protection               protection, surge and transient protection and earthing solutions.
equipment and earthing products to a wide
                                                      • Stormaster range of ESE Air terminals, compliant to NF C 17-102
range of industries throughout the world.
                                                      • Guardian Lightning Protection System 5, tested to IEC 60-1:1989
        personnel and their associates have           • Conventional lightning protection
combined experience over many years in servicing      • Surge and Transient protection products for power lines
customers throughout the world on many types of
                                                      • Surge and Transient protection products for data,
projects in some of its most lightning prone areas.     communications and signal lines
Our personnel have vast experience in providing
                                                      • “EXOWELD” range of exothermic welding products for the
direct strike area protection, surge and transient
                                                        connection of earthing conductors
protection and earthing solutions. Our extensive
                                                      • Earth rods and accessories
experience has involved risk management, system
design, training, certification and installation and   • Earth Enhancing Compounds for the lowering of soil resistivity
commissioning in key industry groups such as:
  • Telecommunications & Broadcasting                                                                        ����������
                                                                                                             �����������
  • Petrochemical, oil & gas                                                                                 � ����
                                                                                                             ���������
  • Highrise buildings and hotels – all types of
    structures                                                                                           �������������
                                                             ����������
                                                             ����������������
  • Sporting centre and grounds – Golf courses,
    race tracks, stadiums
  • Aviation - Civil & Military                                                                             ������������
                                                                                                            ��������������
  • Mining – coal, gold, nickel, iron, copper,
    bauxite etc.
  • Industrial facilities of all kinds
  • Defence – communications, surveillance                                                                  �����������
    and storage of armaments
  • Power generation and distribution
  • Rail / transport systems
  • Monuments / Ecological sites                             �����������������                              ���������
                                                             ������������������                             ������
                                                             ������                                         ��������
                                                                                                            �����
LPI’s Stormaster ESE
The         Stormaster ESE range of terminals provides a                 The energy is conveyed to ground via downconductor(s).
safe and efficient system for the protection of your facility             When the energy enters the dedicated lightning earth, it is
from direct lightning strikes. The LPI Stormaster ESE                    safely dissipated without risk to personnel and equipment.
terminal captures the lightning energy at a preferred point.
How does the LPI Stormaster ESE Terminal work?
The Stormaster Early Streamer Emission air terminal                      which initiates the triggering of an upward streamer from
uses the naturally occurring electrical field to complete                 the Stormaster ESE terminal. The concept of earlier allows
the timely release of an upward streamer. This process                   for a larger or enhanced area of protection to be provided
provides for a safe and efficient method of controlling                   by the Stormaster ESE in comparison to a conventional rod.
dangerous lightning energy at a preferred point.
                                                                         With the release of the upward streamer from the finial
As a thunder storm gathers overhead the ambient electrical               tip earlier than other competing structural points,
field surrounding the Stormaster ESE begins to rise in                    the Stormaster ESE terminal becomes a preferred
voltage. Upon the approach of a downleader towards the                   point for the capture of the lightning discharge
protected area there is a rapid increase in the electric field            within the protected area.
The Stormaster ESE Range
         offers four models in
                                   STORMASTER-ESE-15, 30 & 50                   STORMASTER-ESE-60
it’s range of Early Streamer
Emission air terminals.
All terminals have been
tested to NF C 17-102.
  Stormaster-ESE-15
  Stormaster-ESE-15-GI
  Stormaster-ESE-30
  Stormaster-ESE-30-GI
  Stormaster-ESE-50
  Stormaster-ESE-50-GI
  Stormaster-ESE-60
                                  • GI Model - For direct mounting to 2” dia. GI Pipe.
  Stormaster-ESE-60-GI            • Stainless Steel Stormaster ESE terminals available upon request.
Lightning Strike Recorder (LSR)
        have developed a Lightning Strike Recorder (LSR) which is designed for
easy mounting on a downconductor to effectively count the number of lightning
strikes captured by the Stormaster ESE Terminal.
The LSR has a current sensitivity range of 1500A through to a maximum of 220kA
@ 8/20µs impulse and operates by sensing current by means of an inductive
pickup loop. The strike recorder has a mechanical 6 digit display secured within a
           polycarbonate IP 67 rated enclosure. The LSR is self powered and
              does not require the use of a battery or any external power source.
Certified Performance
As one of the leading companies in the field of lightning protection,
        has invested heavily in field and laboratory testing as part of
its on-going commitment to research and development.
 Throughout the product development of the Stormaster ESE the
 proto-type models were subjected to intense testing under high
 voltage conditions. Following further refinements the Stormaster
  terminals were subjected to final testing by an independently
  accredited test laboratory which completed testing in full
   compliance with the French National Standard NF C 17-102.
   The final testing of Stormaster ESE terminals showed effective
   performance as defined in the French National Standard.
       The objective of the testing under NF C 17-102 is to
          obtain a statistical result between a single reference
            rod and the ESE terminal whereby a time
               difference is obtained between the two and by
                  definition, a triggering time advance ∆T is
                    calculated. Safety margins are applied to
                      the measured values in order to provide
                        a conservative measured result.
                             Advantages of                                           •           ’s Stormaster ESE system is simple to
                                                                                         install and requires no special maintenance.
                             the Stormaster
                              ESE Terminal                                           •           ’s Stormaster ESE system is a cost
                                                                                         effective solution for providing your lightning
                               A typical Stormaster ESE installation                     protection whilst providing superior safety.
                               consists of a single Stormaster
                              ESE terminal with an enhanced                          • The Stormaster ESE range of terminals have
                              area of protection and one or more                         been fully tested in accordance with NF C 17-102
                             downconductors connected to a                               in a high voltage laboratory.
                            dedicated low impedance lightning earth.
        Ground Resistance
        Improvement Powder (GRIP)
        Ground Resistance Improvement Powder is an earth enhancing material
        which is applied in and around an earthing system to reduce the soil
        resistivity and lower ground impedance. GRIP is supplied in 10kg and
        40kg kits and is particularly useful in difficult sites such as sandy soils
        and rocky ground. LPI recommends the installation of a radial lightning
        earth to aid in the efficient dissipation of the lightning energy.
        Contact          or an authorised representative for design assistance and
        for further details on LPI’s complete range of earth enhancing compounds.
Protection Performance
The protection radius (Rp) of a Stormaster ESE terminal is calculated using the                                  Rp3
                                                                                                      h1         Rp2
following formula as defined by the French National Standard NF C 17-102 (July                              Rp1
1995).                                                                                           h2
Rp = √h(2D-h) + ∆T(2D + ∆T) for ≥5m where:
                                                                                           h3
The following key parameters determine the calculation of RP.
• ∆T as established during the test.
  Stormaster-ESE-15 = ∆T (µs) 15
  Stormaster-ESE-30 = ∆T (µs) 30
  Stormaster-ESE-50 = ∆T (µs) 50
  Stormaster-ESE-60 = ∆T (µs) 60
• h = actual height of Stormaster terminal above the area to be protected (m).
• D (in m) depends on the selected level of protection, protection
  levels are specified in annex B of the standard NF C 17-102.
  D = 20m for protection level 1 (High Protection)
  D = 45m for protection level 2 (Medium protection)
  D = 60m for protection level 3 (Standard protection)
                                  PROTECTION RADIUS (M) - (Rp)
  h = height of Stormaster terminal          2    4    5     6     10    15    20    45    60
  above area to be protected (m)
  Protection Level 1 (High Protection)
  Stormaster 15                              13   25   32    32    33    34    35    35    35
  Stormaster 30                              19   28   48    48    49    50    50    50    50
  Stormaster 50                              28   55   68    69    69    70    70    70    70
  Stormaster 60                              32   64   79    79    79    80    80    80    80
  Protection Level 2 (Medium Protection)
  Stormaster 15                              18   36   45    46    49    52    55    60    60
  Stormaster 30                              25   50   63    64    66    68    71    75    75
  Stormaster 50                              35   69   86    87    88    90    92    95    95
  Stormaster 60                              40   78   97    97    99    101   102   105   105
  Protection Level 3 (Standard Protection)
  Stormaster 15                              20   41   51    52    56    60    63    73    75
  Stormaster 30                              28   57   71    72    75    77    81    89    90
  Stormaster 50                              38   76   95    96    98    100   102   110   110
  Stormaster 60                              44   87   107   107   109   111   113   120   120
Research and Development
The company has an ongoing commitment to Research and Development.
         personnel and its associates have been involved in a number of field
trials throughout lightning prone regions of the world. This experience has
extended throughout such countries as Australia, Indonesia, Sri Lanka the
USA and South Korea.
LPI Customers                                                                 LPI’s 4-Step Approach to
       Proudly services customers from the following                          Lightning Protection
countries:
                                                                              It is the strategic aim of our company to be able to provide a
                                                                              complete packaged solution.          has identified 4 key steps
                                                                              when considering the complete approach to lightning protection,
    •   Australia              •   Japan                      • Philippines
                                                                              ask for our LPI 4 Step approach to lightning protection.
    •   Bahrain                •   Kuwait                     • Qatar
    •   Bangladesh             •   Laos                       • Saudi
                                                                Arabia                                     Our system design
    •   Brunei                 •   Mainland
                                   China                      • Singapore                                  approach includes:
    •   Burundi
                               •   Malaysia                   • South
    •   Cambodia
                                                                Korea              1    Definition and provision of area protection
    •   Chile                  •   Maldives
                               •   Maurtitius                 • Sri Lanka          2    Creation of a bonded earthing system
    •   Costa Rica
                               •   Myanmar                    • Taiwan
    •   Ecuador                                                                    3    Protection of power lines
                               •   New Zealand                • Thailand
    •   Guatemala                                                                  4    Protection of signal, data and communication lines
                               •   Nigeria                    • UAE
    •   Haiti
                               •   Oman                       • United
    •   Hong Kong                                               Kingdom
    •   India                  •   Papua New
                                   Guinea                     • USA
    •   Indonesia                                             • Vietnam
                               •   Peru
    •   Iran
Disclaimer
                                                                              LIGHTNING PROTECTION INTERNATIONAL PTY. LTD.
• LPI maintains a policy of on-going product development,                                                                       ABN 11 099 190 897
  specifications are subject to change without notice.
• Application detail, illustrations and schematic drawings are                                               16 Mertonvale Circuit, Kingston
  representative only and should be used as guides.                                                         Tasmania, Australia 7050.
• It should noted that 100% (100 percent) protection level                                                  Telephone: + 61 3 6227 1955
  for direct strike lightning and surge and transient protection                                            Facsimile: + 61 3 6229 1900
  equipment is not possible and cannot be provided due to the                                               Email:     info@lpi.com.au
  lightning discharge process being a natural atmospheric event.
                                                                                                            Web:         www.lpi.com.au
©Copyright 2007 Lightning Protection International Pty Ltd.                                                                            BR-STORM-V4