Keypadprogramming: (Section 2.5 "Keypad Assignment" On Page 4)
Keypadprogramming: (Section 2.5 "Keypad Assignment" On Page 4)
30
                                                                                                              Pr o g r a m m i n g      W o r k sh e e t s
[0 0 8 ] M a int e na nce Code (Section 5.1 “Programming Security Codes” on page 15)
 Default
  AAAA         I_______I_______I_______I_______I
[0 0 9 ] PGM Out put Progra m m ing (PGM 1 and 2 ) (Section 5.11 “PGM Output Options” on page 20)
Programmable Output Options
      01 Burglary and Fire Bell Output                               14 Ground Start Pulse
      02 For future use                                              15 Remote Operation (DLS-1 Support)
      03 Sensor Reset                                                16 LINKS1000 Support (PGM1 only)
      04 2-wire smoke                                                17 Away Armed Status
      05 System Armed Status                                         18 Stay Armed Status
      06 Ready To Arm                                                19 Command Output #1 ([*][7][1])
      07 Keypad Buzzer Follow Mode                                   20 Command Output #2 ([*][7][2])
      08 Courtesy Pulse                                              21 For future use
      09 System Trouble Output (with Trouble options)                22 For future use
      10 System Event [Strobe (with Event options)]                  23 Silent 24 Hour (PGM2 Only)
      11 System Tamper (all sources: zones, kpd, modules)            24 Audible 24 Hour (PGM2 Only)
      12 TLM and Alarm
      13 Kissoff Output
NOTE:Output types [03], [04] and [20] cannot be used together on the same system.
 Default                                               Default
    19       I_______I_______I     PGM 1                   10          I_______I_______I   PGM 2   Program PGM Option Attributes in sections [141] & [142].
                                                                                                                                                              31
[0 1 2] K e ypa d Loc k out Opt ions (Section 5.21 “Keypad Lockout Options” on page 25)
NOTE:If Keypad Lockout is active, the panel cannot be disarmed with a keyswitch.
 Default
  000          I_______I_______I_______I   Number of Invalid Codes Before Lockout (001-255 codes)
     000       I_______I_______I_______I   Lockout Duration (001-255 minutes)
[0 1 3] First Syst em Opt ion Code
 Default          Option ON                                                         Off                                         Section Page #
   OFF I________I   1    Normally Closed Loops                                      End-of-Line Resistors                         2.8     5
     OFF   I________I          2             Double End-of-Line Resistors           Single End-of-Line Resistors                  2.8     5
     ON*   I________I          3             Panel shows all troubles when armed    Panel shows only Fire troubles when armed     3.4     8
     OFF   I________I          4             Tampers/Faults do not show as open     Tampers/Faults show as open                   3.4     8
     OFF   I________I          5             For future use
     ON    I________I          6             Audible Exit Fault Enabled             Audible Exit Fault Disabled                   5.18   24
     ON    I________I          7             Event Buffer Follows Swinger Shutdown Event Buffer Logs Events Past shutdown         5.20   24
     OFF   I________I          8             Temporal Three Fire Signal Enabled**   Standard Pulsed Fire Signal                   5.13   23
* Option 3 must be OFF if LCD keypads older than v2.0 are used.
**The Temporal Three Fire Signal option must be used for UL Household Fire installations.
[0 1 4] Se c ond Syst e m Opt ion Code
 Default          Option  ON                                                        Off                                         Section Page #
   OFF I________I   1     Arm / Disarm Bell Squawk enabled                          Arm / Disarm Bell Squawk disabled            5.17     23
     OFF   I________I          2             Bell Squawk During Auto Arm            No Bell Squawk During Auto Arm                5.18    24
     OFF   I________I          3             Bell Squawk On Exit Delay              No Bell Squawk On Exit Delay                  5.18    24
     OFF   I________I          4             Bell Squawk On Entry Delay             No Bell Squawk On Entry Delay                 5.18    24
     OFF   I________I          5             Bell Squawk On Trouble                 No Bell Squawk On Trouble                     3.4     8
     ON    I________I          6             Audible Exit with Urgency              Silent Exit Delay                             5.18    24
     OFF   I________I          7             Exit Delay Termination Enabled         Exit Delay Termination Disabled               5.18    24
     OFF   I________I          8             Fire Bell is Continuous                Fire Bell Follows Bell Cut-off                5.13    23
[0 1 5] T hird Syst e m Opt ion Code
 Default          Option  ON                                                        Off                                         Section Page #
    ON I________I   1     Fire Keys Enabled                                         Fire Keys Disabled                           5.16     23
     OFF   I________I          2             Panic Keys Audible (Bell / Beeps)      Panic Keys Silent                             5.16   23
     OFF   I________I          3             Quick Exit Enabled                     Quick Exit Disabled                           3.4     8
     ON*   I________I          4             Quick Arming Enabled                   Quick Arming Dis. / Function keys Req. Code   3.4     8
     OFF   I________I          5             Code Required For Bypassing            No Code Required                              3.4     8
     OFF   I________I          6             Master Code Not Changeable             Master Code Changeable                        5.1    15
     ON    I________I          7             TLM Enabled                            TLM Disabled                                  5.12   22
     OFF   I________I          8             TLM Audible (Bell) When Armed          TLM Trouble Beeps When Armed                  5.12   22
* When using a PC5132 version 2.1 or older with WLS909 Wireless Keys, option [4] must be ON for the Arm button to work.
[0 1 6] Fourt h Syst e m Opt ion Code
 Default          Option  ON                                                        Off                                         Section Page #
    ON I________I   1     AC Trouble Displayed                                      AC Trouble Not Displayed                      3.4     8
     OFF   I________I          2             Trouble Light Flashes if AC Fails      Trouble Light Does Not Follow AC Status       3.4     8
     OFF   I________I          3             Blank Keypad When Not Used             Keypad Active Always                          5.22   25
     OFF   I________I          4             Code Required to Remove Kypd BlankingNo Code Required                                5.22   25
     ON    I________I          5             Keypad Backlighting is enabled         Keypad Backlighting is disabled               5.23   25
     OFF   I________I          6             Power Save Mode enabled                Power Save Mode disabled                      5.22   25
     OFF   I________I          7             Bypass Status Displayed While Armed Bypass Status Not Displayed While Armed          5.17   23
     OFF   I________I          8             Keypad Tampers enabled                 Keypad Tampers disabled                       5.25   25
32
                                                                                            Pr o g r a m m i n g   W o r k sh e e t s
                                                                                                                                     33
Adva nc e d Syst e m Progra m m ing
Z one At t ribut es (Section 5.3 “Zone Attributes” on page 16)
Zone Attribute Defaults (Y = Option ON; N = Option OFF):
 Attribute:                           1              2           3             4            5             6              7               8
                            ON     Audible        Steady       Chime        Bypass        Force*        Swing        Tx. Delay      Wireless Zn.
                           OFF      Silent        Pulsed        No            No           No            No             No               No
 Zone Type:
 00 Null Zone                          N             N            N            N            N              N             N                 N
 01 Delay 1                            Y             Y            Y            Y            N              Y             N                 N
 02 Delay 2                            Y             Y            Y            Y            N              Y             N                 N
 03 Instant                            Y             Y            Y            Y            N              Y             N                 N
 04 Interior                           Y             Y            N            Y            N              Y             N                 N
 05 Int. Stay/Away                     Y             Y            N            Y            Y              Y             N                 N
 06 Dly. Stay/Away                     Y             Y            N            Y            Y              Y             N                 N
 07 Dly. 24hr Fire (Hardw.)            Y             N            N            N            N              N             N                 N
 08 Stand. 24hr Fire (Hardw.)          Y             N            N            N            N              N             N                 N
 09 24hr Superv.                       N             Y            N            N            Y              N             N                 N
 10 24hr Superv. Buzzer                N             Y            N            Y            N              N             N                 N
 11 24hr Burglary                      Y             Y            N            Y            N              N             N                 N
 12 24hr Holdup                        N             Y            N            N            N              N             N                 N
 13 24hr Gas                           Y             N            N            N            N              N             N                 N
 14 24hr Heating (N/C zone)            Y             N            N            N            N              N             N                 N
 15 24hr Medical                       Y             Y            N            N            N              N             N                 N
 16 24hr Panic                         Y             Y            N            N            N              N             N                 N
 17 24hr Emergency                     Y             Y            N            N            N              N             N                 N
 18 24hr Sprinkler                     Y             Y            N            N            N              N             N                 N
 19 24hr Water                         Y             Y            N            N            N              N             N                 N
 20 24hr Freeze                        Y             Y            N            N            N              N             N                 N
 21 24hr Latching Tamper               Y             Y            N            N            N              N             N                 N
 22 Momentary Keyswitch                N             N            N            N            Y              N             N                 N
 23 Maintained Keyswitch               N             N            N            N            Y              N             N                 N
 24 LINKS Answer                       N             N            N            N            Y              N             N                 N
 25 Interior Delay                     Y             Y            N            Y            N              Y             N                 N
 87 Dly. 24hr Fire (Wireless)          Y             N            N            N            N              N             N                 Y
 88 Stand. 24hr Fire (Wireless)        Y             N            N            N            N              N             N                 Y
*NOTE: For UL installations, do not change attribute 5 (Force Arming) from the default setting.
Section Zone #        Zone              1            2            3             4             5             6            7               8
                     Type*
[101]         1      (    )          I________I   I________|   I________|    I________|    I________|   I________|     I________|     I________I
34
                                                                                                                                                Pr o g r a m m i n g                          W o r k sh e e t s
PGM Out put At t ribut e s (Section 5.11 “PGM Output Options” on page 20)
Program only the following attributes for the PGM options listed. All others will be ignored. PGM options are programmed in [009].
PGM Attribute Defaults (Y = Attribute ON; N = Attribute OFF):
Attribute:                                    1                    2                   3                      4                       5
                          ON           Output enabled              —           True Output          Follows Timer              Code Req.
Attribute:                                   1                    2                    3                      4                       5                       6                     7                      8
PGM Option
                             ON          Serv. req.             AC Fail         TLM Fault                   FTC                Zone Fault                  Zone Tmp.           Zn. Low Bat.          Loss of Clock
                             OFF         Disabled          Disabled               Disabled                 Disabled                Disabled                Disabled             Disabled                Disabled
[09] System Trouble                          Y                    Y                    Y                      Y                       Y                       Y                     Y                      Y
                             ON         Burg. Evnt.        Fire Evnt.           Panic Evnt.           Med. Evnt.               Supv. Evnt.            Priority Evnt.           Holdup Evnt.          Follows Timer*
                             OFF         Disabled          Disabled               Disabled             Disabled                    Disabled                Disabled             Disabled                Latched
[10] System Event                            Y                    Y                    Y                      Y                       Y                       Y                     Y                      N
                                       *If attribute [8] is turned ON, attributes [1-7] must also be turned ON.
                                                                                                                                                                                                                         35
Section PGM                         Output                  1                        2                      3                          4                          5                          6                       7                         8
         #                          Type*
[141]    1                          (    )              I________I                I________|            I________|                  I________|                 I________|                I________|               I________|                I________I
[3 0 2] Se c ond Te le phone N um be r (3 2 Digit s) (Section 5.7 “Communicator – Telephone Numbers” on page 17)
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
[3 0 3] T hird Te le phone N um be r (3 2 Digit s) (Section 5.7 “Communicator – Telephone Numbers” on page 17)
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
[3 1 0] First /T hird Te le phone N um be r Ac c ount Code (Section 5.6 “Communicator – Account Numbers” on page 17)
I_______I_______I_______I_______I
[3 1 1] Se c ond Te le phone N um be r Ac c ount Code (Section 5.6 “Communicator – Account Numbers” on page 17)
I_______I_______I_______I_______I
36
                                                                                                                               Pr o g r a m m i n g            W o r k sh e e t s
Ala rm Re port ing Code s, Z one s 1 -32 (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
Section
  [320]   Zone 1        Zone 2          Zone 3           Zone 4          Zone 5          Zone 6          Zone 7                                                             Zone 8
                I_______I_______I    I_______I_______I   I_______I_______I            I_______I_______I    I_______I_______I        I_______I_______I   I_______I_______I   I_______I_______I
Ala rm Re st ora l Re port ing Code s, Z one s 1 -3 2 (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
Section
  [324]   Zone 1           Zone 2        Zone 3           Zone 4         Zone 5            Zone 6          Zone 7          Zone 8
                I_______I_______I    I_______I_______I   I_______I_______I            I_______I_______I    I_______I_______I        I_______I_______I   I_______I_______I   I_______I_______I
[3 2 8 ] M isc e lla ne ous Ala rm Re port ing Code s (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
         I_______I_______I 1. Duress Alarm            I_______I_______I 4. Zone Expander Supervisory Alarm
       I_______I_______I    2. Opening After Alarm                           I_______I_______I     5. Zone Expander Supervisory Restoral
       I_______I_______I    3. Recent Closing                                I_______I_______I     6. Cross Zone Police Code Alarm
[3 2 9 ] Priorit y Ala rm a nd Re st ora l (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
         I_______I_______I 1. Keypad Fire Alarm           I_______I_______I 5. Keypad Fire Restoral
       I_______I_______I   2. Keypad Auxiliary Alarm                         I_______I_______I     6. Keypad Auxiliary Restoral
       I_______I_______I   3. Keypad Panic Alarm                             I_______I_______I     7. Keypad Panic Restoral
       I_______I_______I   4. PGM2 Alarm                                     I_______I_______I     8. PGM2 Restoral
Tam pe r Re port ing Code s, Z one s 1 -3 2 (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
 Section
  [330]   Zone 1        Zone 2           Zone 3            Zone 4         Zone 5          Zone 6          Zone 7                                                            Zone 8
                I_______I_______I    I_______I_______I   I_______I_______I            I_______I_______I    I_______I_______I        I_______I_______I   I_______I_______I   I_______I_______I
Tam pe r Re st ora l Re port ing Code s, Z one s 1 -8 (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
 Section
  [334]   Zone 1          Zone 2         Zone 3          Zone 4          Zone 5            Zone 6          Zone 7          Zone 8
                I_______I_______I    I_______I_______I   I_______I_______I            I_______I_______I    I_______I_______I        I_______I_______I   I_______I_______I   I_______I_______I
                                                                                                                                                                                        37
[3 3 8] Misc e lla ne ous Ta m pe r Re port ing Code s (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
        I_______I_______I 1. General System Tamper
[3 4 8] Misc e lla ne ous Ope ning (Disa rm ing) Re port ing Code s
(Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
         I_______I_______I   1. Opening by Duress Code 33                       I_______I_______I      5. Opening by Supervisory Code 42
         I_______I_______I   2. Opening by Duress Code 34                       I_______I_______I      6. Auto Arm Cancellation
         I_______I_______I   3. Opening by Master Code 40                       I_______I_______I      7. Special Opening
         I_______I_______I   4. Opening by Supervisory Code 41
[3 4 9] Ma int e na nc e Ala rm Re port ing Code s (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
        I_______I_______I 1. Battery Trouble Alarm   I_______I_______I 5. Auxiliary Power Supply Trouble Alarm
         I_______I_______I   2. AC Failure Trouble Alarm                        I_______I_______I      6. TLM Trouble Code (via LINKS)
         I_______I_______I   3. Bell Circuit Trouble Alarm                      I_______I_______I      7. For future use
         I_______I_______I   4. Fire Trouble Alarm                              I_______I_______I      8. General System Supervisory
[3 5 0] Ma int e na nc e Re st oral Re port ing Code s (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
        I_______I_______I 1. Battery Trouble Restoral I_______I_______I 5. Auxiliary Power Supply Trouble Restoral
         I_______I_______I    2. AC Failure Trouble Restoral                    I_______I_______I      6. TLM Restoral
         I_______I_______I    3. Bell Circuit Trouble Restoral                  I_______I_______I      7. For future use
         I_______I_______I    4. Fire Trouble Restoral                          I_______I_______I      8. General System Supervisory Restore
38
                                                                                                            Pr o g r a m m i n g   W o r k sh e e t s
[3 5 1 ] M isc e lla ne ous M a int e na nc e Report ing Code s (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
         I_______I_______I 1. Telephone Number 1 FTC Restore     I_______I_______I 5. DLS Lead OUT
        I_______I_______I       2. Telephone Number 2 FTC Restore              I_______I_______I   6. Zone Fault Alarm
        I_______I_______I       3. Event Buffer 75% Full Since Last Upload     I_______I_______I   7. Zone Fault Restore
        I_______I_______I       4. DLS Lead IN                                 I_______I_______I   8. Delinquency Code
[3 5 2 ] Te st Tra nsm ission Re port ing Code s (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
         I_______I_______I 1. Periodic Test Transmission      I_______I_______I 3. LINKS1000 Test Transmission Code*
                   2. System Test
        I_______I_______I
        *The LINKS Test Transmission Code must be programmed as “00” for the LINKS Test Transmission to be disabled.
[3 5 3 ] Wire less M a int e na nc e Re port ing Code s (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
         I_______I_______I 1. Wireless Device Low Battery Alarm I_______I_______I 2. Wireless Device Low Battery Restore
[3 6 0 ] Com m unic a t or Forma t Opt ions (Section 5.9 “Communicator – Reporting Formats” on page 19)
NOTE:The Third telephone number follows the format of the First telephone number.
 Default
   02            I_______I_______I        1st/3rd Telephone Number
   02            I_______I_______I        2nd Telephone Number
   01 20 BPS, 1400 HZ handshake                            04 SIA FSK
   02 20 BPS, 2300 HZ handshake                            05 Pager
   03 DTMF CONTACT ID
[3 6 1 ] Ala rm /Re st ore Comm unic a t or Ca ll Dire c t ions (Section 5.5 “Communicator – Dialing” on page 17)
 Default                Option ON                                                 OFF
    ON        I_______I   1    1st Telephone Number                               Disabled
  OFF            I_______I           2           2nd Telephone Number                                   Disabled
  OFF            I_______I           3           1st Telephone Number (via LINKS)                       Disabled
  OFF            I_______I           4           2nd Telephone Number (via LINKS)                       Disabled
  OFF            I_______I           5-8         For future use
[3 6 3 ] Ta mpe r/Re st ore Com munic a t or Ca ll Dire c t ions (Section 5.5 “Communicator – Dialing” on page 17)
 Default                Option ON                                                 OFF
    ON       I________I   1    1st Telephone Number                               Disabled
  OFF            I________I           2          2nd Telephone Number                                   Disabled
  OFF            I________I           3          1st Telephone Number (via LINKS)                       Disabled
  OFF            I________I           4          2nd Telephone Number (via LINKS)                       Disabled
  OFF            I________I          5-8         For future use
[3 6 5 ] Ope ning/Closing Com m unic a t or Ca ll Dire c t ions (Section 5.5 “Communicator – Dialing” on page 17)
 Default               Option ON                                                 OFF
    ON      I________I   1    1st Telephone Number                               Disabled
  OFF            I________I           2          2nd Telephone Number                                   Disabled
  OFF            I________I           3          1st Telephone Number (via LINKS)                       Disabled
  OFF            I________I           4          2nd Telephone Number (via LINKS)                       Disabled
  OFF            I________I          5-8         For future use
[367] System Maintenance Alarm/Restore Communicator Call Directions (Section 5.5 “Communicator – Dialing” on page 17)
 Default             Option ON                                   OFF
   ON     I________I   1    1st Telephone Number                 Disabled
  OFF            I________I           2          2nd Telephone Number                                   Disabled
  OFF            I________I           3          1st Telephone Number (via LINKS)                       Disabled
  OFF            I________I           4          2nd Telephone Number (via LINKS)                       Disabled
  OFF            I________I          5-8         For future use
                                                                                                                                                  39
[3 6 8] Syst e m Te st Tra nsm issions Com m unic a t or Ca ll Dire c t ions (Section 5.5 “Communicator – Dialing” on page 17)
 Default              Option  ON                                               OFF
    ON     I________I   1     1st Telephone Number                             Disabled
     OFF       I________I           2         2nd Telephone Number                              Disabled
     OFF       I________I           3         1st Telephone Number (via LINKS)                  Disabled
     OFF       I________I           4         2nd Telephone Number (via LINKS)                  Disabled
  OFF    I________I 5-8  For future use
NOTE:The LINKS1000 backup call directions will only back up their respective telephone numbers.
[3 7 0] Com m unic a t ion Va ria ble s
 Default                                                                                                                       Section    Page #
    003   I_______I_______I_______I Swinger Shutdown (Alarms and Rest) (001-014 Transmissions, 000=disabled)                    5.19        24
     003     I_______I_______I_______I   Swinger Shutdown (Tampers and Rest)(001-014 Transmissions, 000=disabled)                5.19       24
     003     I_______I_______I_______I   Swinger Shutdown (Maint and Rest)     (001-014 Transmissions, 000=disabled)             5.19      24
     000     I_______I_______I_______I   Transmission Delay                    (001-255 seconds)                                 5.15      23
     030     I_______I_______I_______I   AC Failure Communication Delay        (001-255 minutes)                                  5.8      18
     003     I_______I_______I_______I   TLM Trouble Delay                     (No. of checks required - valid entries 003 - 255) 5.12     22
     030     I_______I_______I_______I   Test Transmission Cycle (land line)   (001-255 days)                                    5.14      23
     030     I_______I_______I_______I   Test Transmission Cycle (LINKS)       (001-255 days)                                    5.14      23
     007     I_______I_______I_______I   Zone Low Battery Transmission Delay (000-255 days)                                       5.8      18
  030    I_______I_______I_______I Delinquency Transmission Cycle (000-255 days/hours)                                            5.8      18
NOTE: To disable the AC failure communications delay, program [000].
[3 7 1] Te st Tra nsm ission T ime of Da y (Section 5.14 “Test Transmission” on page 23)
 Default
   9999      I_______I_______I_______I_______I (Valid entries are 0000-2359, 9999 to disable)
[3 8 0] First Com m unic at or Opt ion Code
 Default         Option   ON                                                        Off                                          Section Page #
    ON I_______I   1      Communications Enabled                                    Communications Disabled                        5.5     17
     OFF   I_______I            2          Restorals on Bell Time-out               Restorals Follow Zones                          5.8    18
     OFF   I_______I            3          Pulse Dialing                            DTMF Dialing                                    5.5    17
     ON    I_______I            4          Switch to Pulse Dialing on 5th Attempt   DTMF Dial For All Attempts                      5.5    17
     OFF   I_______I            5          3rd Telephone Number enabled             3rd Telephone Number disabled                   5.7    17
     OFF   I_______I            6          Alternate Dial (1st and 3rd)             Call 1st Number, Backup to 3rd                  5.7    17
     OFF   I_______I            7          Call LINKS as well as Land Line          LINKS is Backup of Land Line(s)                5.26    25
     OFF   I_______I            8          Delinquency Follows Zone Activity (Hours)Delinquency Follows Arming (Days)               5.8    18
[3 8 1] Se c ond Comm unic a t or Opt ion Code
 Default         Option ON                                                              Off                                    Section Page #
   OFF I_______I   1    Open After Alarm Kypd Ringback enabled                          Open After Alrm Kypd Ringback disabled  5.17     23
     OFF   I_______I            2        Open After Alarm Bell Ringback enabled         Open After Alrm Bell Ringback disabled     5.17    23
     OFF   I_______I            3        SIA Sends Programmed Rep. Codes                SIA Sends Automatic Rep. Codes              5.9    19
     OFF   I_______I            4        Closing Confirmation Enabled                   Closing Confirmation Disabled              5.17    23
     OFF   I_______I         5-6         For future use                                 —
     ON    I_______I            7        Contact ID Uses Programmed Reporting CodesContact ID Uses Auto Reporting Codes             5.9    19
     OFF   I_______I            8        For future use                             —
[3 9 0] LI N K S Pre a m ble (First Te le phone N um be r) (Section 5.26 “LINKS1000 Cellular Communicator*” on page 25)
Default: FFFF       I_______I_______I_______I_______I (Program all unused digits with Hex F)
[3 9 1] LI N K S Pre a m ble (Se c ond Te le phone N um ber) (Section 5.26 “LINKS1000 Cellular Communicator*” on page 25)
Default: FFFF       I_______I_______I_______I_______I (Program all unused digits with Hex F)
40
                                                                                                                                                                                    Pr o g r a m m i n g   W o r k sh e e t s
[3 9 2 ] LI N K S Pre a m ble (T hird Te le phone N um be r) (Section 5.26 “LINKS1000 Cellular Communicator*” on page 25)
Default: FFFF        I_______I_______I_______I_______I (Program all unused digits with Hex F)
[3 9 3 ] LI N K S Spe c ia l Func t ion Pre a m ble (All Te le phone N um be rs) (Section 5.26 “LINKS1000 Cellular Communicator*” on
page 25)
Default: FFFFFF                          I_______I_______I_______I_______I_______I_______I    (Program all unused digits with Hex F)
                 •Enter [*][2][*] (HEX B) to dial [*]                                                            • Enter [*][3][*] (HEX C) to dial [#]
[4 0 3 ] Dow nloa ding Ac c ess Code (Section 5.10 “Downloading” on page 20)
Default: 1555 I_______I_______I_______I_______I Enter 4 HEX digits
[4 0 4 ] Pa ne l I de nt ific a t ion Code (Section 5.10 “Downloading” on page 20)
Default: 1555 I_______I_______I_______I_______I Enter 4 HEX digits
[4 0 5 ] Answ e ring Ma c hine Double -c a ll T im e r (Section 5.10 “Downloading” on page 20)
Default: 060 I_______I_______I_______I (Valid entries are 001-255 seconds)
[4 0 6 ] N um be r of Rings t o Answ e r On (Section 5.10 “Downloading” on page 20)
Default: 000 I_______I_______I_______I (Valid entries are 000-255 rings)
[4 9 0 ] LI N K S Pre a m ble (Dow nloa ding Te le phone N um ber) (Section 5.10 “Downloading” on page 20)
Default: FFFF I_______I_______I_______I_______I (Program all unused digits with Hex F)
[4 9 9 ] [I nst a lle r’s Code ] [4 9 9 ] I nit ia t e PC-Link (Loc a l Dow nloa ding) (Section 5.10 “Downloading” on page 20)
                                                                                                                                                                                                                             41
Spe c ia l I nst a lle r Func t ions
[9 0 1] I nst a ller Wa lk Te st M ode Ena ble / Disa ble (Section 5.30 “Walk Test (Installer)” on page 26)
[9 0 2] Module Supe rvision Re se t (Section 2.7 “Removing Modules” on page 5)
[9 0 3] Module Supe rvision Fie ld (Section 2.6 “Supervision” on page 5)
[9 0 4] Wire le ss Module Pla c e m e nt Te st
For more information, please refer to your PC5132 Installation Manual
• Select the module / transmitter (Zones 01-32).
• Press [#] to Cancel.
Placement              Led Keypad                        LCD Keypad                     Bell / Buzzer
Good                   Light 1 ON Steady                 “GOOD”                         1 Beep / Squawk
Fair                   Light 2 ON Steady                 “FAIR”                         2 Beeps / Squawks
Bad                    Light 3 ON Steady                 “BAD”                          3 Beeps / Squawks
[9 9 0] I nst a ller Loc kout Ena ble (Section 5.29 “Installer’s Lockout” on page 26)
[9 9 1] I nst a ller Loc kout Disa ble (Section 5.29 “Installer’s Lockout” on page 26)
[9 9 3] Re st ore Alt e rna t ive Comm unic a t or t o Fa c t ory De fa ult Progra m ming
(Section 5.28 “Resetting Factory Defaults” on page 26)
[9 9 6] Re st ore PC5 1 3 2 t o Fa c t ory De fa ult Progra m m ing (Section 5.28 “Resetting Factory Defaults” on page 26)
[9 9 7] Re st ore PC5 4 0 0 t o Fa c t ory De fa ult Progra m m ing (Section 5.28 “Resetting Factory Defaults” on page 26)
[9 9 9] Re st ore PC1 5 5 5 t o Fa c t ory De fa ult Progra m m ing (Section 5.28 “Resetting Factory Defaults” on page 26)
42