DWG PART
QTY DESCRIPTION MATERIAL
REF NUMBER
SHELL
Filament Wound Epoxy/Glass composite - Head
01 1 99302 SHELL
locking grooves integrally wound in place.
HEAD
02 2 51051 Bearing Plate 6061-T6 As per SB-221
03 2 96003 Sealing Plate Engineering Thermoplastic.
04 2 50567 Feed/Conc Port SS-316L As per SA-312
05 2 45090 Port Retainer Set CF8M Cast SS,Two-piece set
06 2 50569 Permeate Port Engineering Thermoplastic.
07 2 45066 Port Nut Engineering Thermoplastic.
08 2 96000 Head Seal Ethylene Propylene - O Ring.
09 4 45312 Port Seal Ethylene Propylene - O Ring.
HEAD INTERLOCK
10 2 47336 Retaining Ring SS-316 As per SA-479
VESSEL SUPPORT
11 2+ 52169 Saddle Engineering Thermoplastic.
12 2+ 45042 Strap Assy. 304 Stainless Steel - PVC cushion
13 4++ 46265 Strap screw. 5/16-18 UNC,2.5'' L, 18-8 Stainless Steel.
ELEMENT INTERFACE
14 2 A/R Adapter Engineering Thermoplastic.
15 4 A/R PWT Seal Ethylene Propylene - O - Ring
16 2 52245 Adapter seal Ethylene Propylene - O - Ring
17 1 45069 Thrust Ring Engineering Thermoplastic.
+ ++
3& 6 Each Furnished With Length code 4, 5, 6 & 7.
RATING: PRECAUTIONS:
ORDERING:
DESIGN PRESSURE……………………..450 PSI DO…read, understand and follow all instructions;
Please note that we require your
(3.1 MPa) failure to take every precaution will void warranty Using the chart below, please check the
membrane brand and model number
MAX. OPERATING TEMP……...…….…...120°F and may result in vessel failure features you require and fax them with
when ordering. If this information is not
(49°C) DO…mount the shell on horizontal members at span your purchase order to our customer
initially available, you may provide it at
MIN. OPERATING TEMP……...…………...20°F “S” using complaint vessel supports furnished; service department for expedited
a later date by checking the appropriate
(-7°C) tighten hold down straps just snug processing.
box below.
FACTORY TEST PRESSURE……….CE / ASME DO…provide overpressure protection for vessel set at For optional materials and/or features
675 PSI / 495 PSI not more than 105% of design pressure not listed below, please consult factory
(4.65Mpa) / (3.41 MPa) DO…inspect end closures regularly; replace for pricing and availability.
BURST PRESSURE……..………………2700 PSI components that have deteriorated and correct
(18.62 MPa) causes of corrosion
INTENDED USE:
VESSEL LENGTH CODE – please check one
The CodeLine Model 80E45 Fiberglass RO DO NOT… make rigid piping connections to ports or
Pressure Vessel is designed for continuous, long- MODEL 80E45 ¨ -1 ¨ -2 ¨ -3 ¨ -4 ¨ -5 ¨ -6 ¨ -7 ¨ -8
clamp vessel in any way that resists growth of
term use as housing for reverse osmosis membrane fiberglass shell under pressure; ∆DIA = 0.02 in.
elements to desalt typical brackish waters at (0.5mm) and ∆L = 0.2 in. (5mm) for a length
pressures up to 450 psi. Any make of eight-inch
MEMBRANE BRAND AND MODEL – please check one and fill in
code –6 vessel
nominal diameter spiral-wound element is easily DO NOT… hang piping manifolds from ports or use
information
accommodated; the appropriate interfacing vessel in any way to support other components;
hardware for the element specified is furnished ¨ Please supply adapters for the following membrane brand and specific model
branch connection piping may be simply
with the vessel. Brand_________________________Model_______________________
supported between the header and port; maximum
The CodeLine Model 80E45 must be installed weight of branch piping; feed/concentrate – 16 lbs
operated and maintained in accordance with the (7 kg); permeate – 8 lbs (4 kg) CERTIFICATION REQUIRED
listed precautions and good industrial practice to DO NOT… operate vessel at pressures and
assure safe operation over a long service life. temperatures in excess of its rating ¨ ASME Stamped and National Board Registered (please consult factory for pricing)
The CodeLine Model 80E45 is designed in DO NOT… operate vessel without permeate ports (ASME Section X)
accordance with the engineering standards of the internally connected with a complete set of ¨ CE Marked
Boiler and Pressure Vessel Code of the American elements and interconnecting hardware ¨ Standard, Certified by Pentair.
Society of Mechanical Engineers (ASME Code) DO NOT… operate vessel with permeate pressure in
Section X. At small additional cost, vessels can be excess of 125 psi at 120°F (0.86 MPa @ 49°C)
inspected during construction by an ASME DO NOT… overtighten the connection to the
Authorized inspector and ASME Code stamped. permeate port (hand-tighten plus one-quarter turn,
EXTERIOR FINISH – please check one
The high performance reinforced plastic shell must check for leaks)
be allowed to expand under pressure; undue DO NOT… tolerate leaks or allow end closures to be ¨ Standard – white high-gloss polyurethane coating.
restraint at support points or piping connections routinely wetted in any way ¨ Option – optional colors are available for 50 or more vessels per order.
can cause leaks to develop in the shell. The end DO NOT… pressurize vessel until double-checking to Call factory for pricing details.
closure, incorporating close fitting, interlocking verify that the retaining ring is completely inside
metal components, must be kept dry and free of the groove MATERIAL OPTIONS
corrosion; deterioration can lead to catastrophic DO NOT… work on any component until first
mechanical failure of the head. verifying that pressure is relieved from vessel ¨ Standard – All materials as per drawing 99112 on the first page.
DO NOT… operate outside the pH range 3-11 ¨ Customer specified materials: -
The end closures, incorporating close-fitting,
(Please consult the factory, as these options will affect pricing and vessel lead-time.)
interlocking metal components, must be kept dry
and free from corrosion; deterioration can lead to
catastrophic mechanical failure of the heads. For complete information on proper use of
this vessel please refer to the 80E series
Pentair will assist the purchaser in determining the USER’S GUIDE Bulletin 523004.
suitability of this standard vessel for their specific
operating conditions. The final determination
however, including evaluation of the standard
material of construction for compatibility with the
specific corrosive environment, shall be the
responsibility of the purchaser.
Specifications are subject to change without notice.
DWG. NO. 99112-T, © Pentair Page 2 of 2.