source: http://www.reinforced-concrete.
com                              This copy will expire in 0 days
Name of Project:           hhghh                                                                             General Notes:
Job No.:                   hhghh                                                                             gkg
Client:                    yyy                                                                               uyuu
Designed by:               uuu                                                                               hgh
Date:                      tyyuy
                                                                                                 Sheet:           2           Of         2
Jerv Works Const.
STAIR DESIGN
Stair no.       2
specification
fy                                                     40000 psi
fc'                                                     3000 psi
unfactored service load
service Live Load                                         100 psf
service Dead Live                                          20 psf (excluding stair self-weight)
stair
ht. of rise, ft.                                           10   ft.
trial rise, 6.5" - 7.5"                                  6.75   in. actual rise 6.67 in.
tread, min 9 in.                                           11   in. (OK - rise and tread proportion)
slab h in.                                                  8   in. >= 7.04 in.             OK
conc. cover, suggested 3/4"                              0.75   in.
 main bar           temp. bar
   #5                  #3
                                                  to reduced deflection
                                                  suggested p = .30 of .75Pb
          reinforcement ratio
  .75Pb >          p         > 200/fy
0.02784043       0.009       >= 0.005
                                                 run = 15.58'
                      top bar
                # 5 - 8.5" c.c
                                                                               top bar
                                                                               # 5 - 8.5" c.c.
                                                                          11 in.                            rise = 10'
                 bottom bar
                 # 5 - 7" c.c.                                                                   6.67 in.   Results:
                                                                                                            1. Height of rise =    10 ft.
                                 slab h= 8 in.                                                              2. Length of run =     15.58 ft.
                                                                                                            3. Stair rise =        6.67 in.
                           temperature bar                                                                  4. Number of rise =    18
                                # 3- 7"c.c                                                                  5. Stair tread =       11 in.
                                                                                                            6. number of tread =   17
                                                                                                            7. Slab thickness =    8 in.
                NO need for shear reinforcement
calculation:
no. of rise                                                        18 no.
rise, in.                                                        6.67 in.
t, tread = t + r = 17.7                                         10.83 in. >>== 9
                                                                  OK
check, t*r = 70 to 75                             70 <      73.37     < 75
                                                                  OK
                                               (OK - rise and tread proportion)
x=                                                            15.58 ft.
y = rise - 1 stair rise                                  9.44416667 ft.
hence, stair span, ft.                                   14.6633333 ft.
considering 1-foot width
trial slab h                                                      8   in.
weight of slab w = S (√r2 + t2)(12.5/t)*1                  192.8673   plf
total WDL                                                  212.8673   plf
wu = 1.4DL+1.7LL                                          468.01422   plf
calculation of d
B1                                                             0.85
but not less than                                              0.65
hence B1 =                                                     0.85
Pb = .85fc'B1/fy[87000/(87000+fy)]                       0.03712057
Pmax = .75Pb                                             0.02784043
Pmin = 200/fy                                                 0.005
adapted P                                                     0.009
m = fy/.85fc'                                            15.6862745
Rn = Pfy(1-Pm/2)                                         334.588235 psi
                                                             s1
                                            (-)M support (+)M middle (-)M support
ACI moment coefficient                           1/16        1/10         1/16
Mu ft-lb = c*Wu*L^2                          6289 32/97 10062.9303 6289.33142
max Mu                                                   10062.9303   ft-lb
max Mn=Mu/Ǿ                                              11181.0336   ft-lb
required d = sqrt (Mn/Rn*b)                              5.78076938   in.
required h = conc. Cover+bar/2+d                               6.84   in.
simple support
min h factor = 20/[(1-(60000-fy)]/[60000+fy)                     25
min h as per ACI Code                                          7.04   in.
min. h required                                                7.04   in.
actual h                                                          8   in.
actual d = h-conc. Cover-bar/2                               6.9375   in.
re-calculate based on actual d
                                                             s1
                                              support       middle      support
Mn = Mu/.90                                 6988.14602   11181.0336   6988.14602
required Rn=Mn/bd^2                         145.196444   232.31431    145.196444
required p=1/m(1-sqrt(1-2m*Rn/fy))          0.00373959   0.00609967   0.00373959
hence p (considering min. 200/fy)              0.005     0.00609967      0.005
required As in^2 =pbd                         0.41625    0.50779746     0.41625
min. As=2.1(sqrtfc'*b*d)/fy                 0.02623687   0.02623687   0.02623687
adapted As                                    0.41625    0.50779746     0.41625
required main bar spacing in.                   8.5           7           8.5
min. bar spacing=3*t or 18"                       18           18              18
adapted spacing of bar                           8.5            7             8.5
                                             # 5- 8.5"c.c   # 5- 7"c.c    # 5- 8.5"c.c
shrinkage and temp. bar
shrinkage and temp. bar in^2 =.002*12*h                          0.192    in2
spacing of temp. bars in. = h*12/total area of temp. ba               7   in. c. c.
min. no. of bar = 1 per tread                                       18    in. c. c.
hence spacing =                                                       7   in. c. c.
                                                             # 3- 7"c.c
check for shear
max Vu=1.15*Wu*L/2                                   3946.02289 lb
concrete shear strength without shear reinforcement
 = Ǿ*2*(sqrtfc')*b*d                                  7751.6435 lb >>>===                3946.02289
                                        NO need for shear reinforcement
 main bar      area in^2      diameter in.                  temp. bar       area in^2    diameter in.
   #3            0.11            0.375                         #3             0.11          0.375
   #4             0.2             0.5                          #4              0.2           0.5
   #5            0.31            0.625                                        0.11          0.375
   #6            0.44            0.75
   #7             0.6            0.875
   #8            0.79              1
   #9              1             1.128
  # 10           1.27            1.27
  # 11           1.56            1.41
                 0.31            0.625