Stair Design Specifications

1. This document provides the design details for a stair with a height of 10 feet and a run of 15.58 feet. 2. The stair specifications include a rise of 6.67 inches and a tread of 11 inches. 3. The calculations show the stair design meets the code requirements for rise and tread proportions, minimum slab thickness, reinforcement ratios, and shear strength.

Uploaded by

Renvil Pedernal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
156 views3 pages

Stair Design Specifications

1. This document provides the design details for a stair with a height of 10 feet and a run of 15.58 feet. 2. The stair specifications include a rise of 6.67 inches and a tread of 11 inches. 3. The calculations show the stair design meets the code requirements for rise and tread proportions, minimum slab thickness, reinforcement ratios, and shear strength.

Uploaded by

Renvil Pedernal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 3

source: http://www.reinforced-concrete.

com This copy will expire in 0 days


Name of Project: hhghh General Notes:
Job No.: hhghh gkg
Client: yyy uyuu
Designed by: uuu hgh
Date: tyyuy
Sheet: 2 Of 2
Jerv Works Const.

STAIR DESIGN

Stair no. 2

specification
fy 40000 psi
fc' 3000 psi

unfactored service load


service Live Load 100 psf
service Dead Live 20 psf (excluding stair self-weight)

stair
ht. of rise, ft. 10 ft.
trial rise, 6.5" - 7.5" 6.75 in. actual rise 6.67 in.
tread, min 9 in. 11 in. (OK - rise and tread proportion)
slab h in. 8 in. >= 7.04 in. OK
conc. cover, suggested 3/4" 0.75 in.

main bar temp. bar


#5 #3
to reduced deflection
suggested p = .30 of .75Pb
reinforcement ratio
.75Pb > p > 200/fy
0.02784043 0.009 >= 0.005

run = 15.58'

top bar
# 5 - 8.5" c.c

top bar
# 5 - 8.5" c.c.

11 in. rise = 10'


bottom bar
# 5 - 7" c.c. 6.67 in. Results:
1. Height of rise = 10 ft.
slab h= 8 in. 2. Length of run = 15.58 ft.
3. Stair rise = 6.67 in.
temperature bar 4. Number of rise = 18
# 3- 7"c.c 5. Stair tread = 11 in.
6. number of tread = 17
7. Slab thickness = 8 in.
NO need for shear reinforcement
calculation:
no. of rise 18 no.
rise, in. 6.67 in.
t, tread = t + r = 17.7 10.83 in. >>== 9
OK
check, t*r = 70 to 75 70 < 73.37 < 75
OK
(OK - rise and tread proportion)

x= 15.58 ft.
y = rise - 1 stair rise 9.44416667 ft.
hence, stair span, ft. 14.6633333 ft.
considering 1-foot width
trial slab h 8 in.
weight of slab w = S (√r2 + t2)(12.5/t)*1 192.8673 plf
total WDL 212.8673 plf
wu = 1.4DL+1.7LL 468.01422 plf

calculation of d
B1 0.85
but not less than 0.65
hence B1 = 0.85
Pb = .85fc'B1/fy[87000/(87000+fy)] 0.03712057
Pmax = .75Pb 0.02784043
Pmin = 200/fy 0.005
adapted P 0.009
m = fy/.85fc' 15.6862745
Rn = Pfy(1-Pm/2) 334.588235 psi

s1
(-)M support (+)M middle (-)M support
ACI moment coefficient 1/16 1/10 1/16
Mu ft-lb = c*Wu*L^2 6289 32/97 10062.9303 6289.33142

max Mu 10062.9303 ft-lb


max Mn=Mu/Ǿ 11181.0336 ft-lb
required d = sqrt (Mn/Rn*b) 5.78076938 in.
required h = conc. Cover+bar/2+d 6.84 in.
simple support
min h factor = 20/[(1-(60000-fy)]/[60000+fy) 25
min h as per ACI Code 7.04 in.
min. h required 7.04 in.
actual h 8 in.
actual d = h-conc. Cover-bar/2 6.9375 in.

re-calculate based on actual d


s1
support middle support
Mn = Mu/.90 6988.14602 11181.0336 6988.14602
required Rn=Mn/bd^2 145.196444 232.31431 145.196444
required p=1/m(1-sqrt(1-2m*Rn/fy)) 0.00373959 0.00609967 0.00373959
hence p (considering min. 200/fy) 0.005 0.00609967 0.005
required As in^2 =pbd 0.41625 0.50779746 0.41625
min. As=2.1(sqrtfc'*b*d)/fy 0.02623687 0.02623687 0.02623687
adapted As 0.41625 0.50779746 0.41625
required main bar spacing in. 8.5 7 8.5
min. bar spacing=3*t or 18" 18 18 18
adapted spacing of bar 8.5 7 8.5
# 5- 8.5"c.c # 5- 7"c.c # 5- 8.5"c.c

shrinkage and temp. bar


shrinkage and temp. bar in^2 =.002*12*h 0.192 in2
spacing of temp. bars in. = h*12/total area of temp. ba 7 in. c. c.
min. no. of bar = 1 per tread 18 in. c. c.
hence spacing = 7 in. c. c.
# 3- 7"c.c
check for shear
max Vu=1.15*Wu*L/2 3946.02289 lb
concrete shear strength without shear reinforcement
= Ǿ*2*(sqrtfc')*b*d 7751.6435 lb >>>=== 3946.02289
NO need for shear reinforcement

main bar area in^2 diameter in. temp. bar area in^2 diameter in.
#3 0.11 0.375 #3 0.11 0.375
#4 0.2 0.5 #4 0.2 0.5
#5 0.31 0.625 0.11 0.375
#6 0.44 0.75
#7 0.6 0.875
#8 0.79 1
#9 1 1.128
# 10 1.27 1.27
# 11 1.56 1.41
0.31 0.625