Hinge Connection Design
A Reference code IS 800-2007
B Input
Fy (shear) = 21.8 kN (Node 65; LC-102)
Fz (Tension) = 21.6 kN
Fx (Shear) = 0 kN
C Tension
no of bolts = 2
Diameter of bolts = 12 mm2
Tension per bolt Ts = 10.80 kN
Area of bolt Asb = 113.04 mm2
Tensile stress per bolt = 95.54 N/mm2
fub Ultimate strength of
= 800
the bolts
An Nominal bore area = 0.78 x pi x d2/4
= 88.17 mm2
Design Tension capacity = 0.9 x fub x An
of bolt Tnb
= 0.9 x 800 x 88.17
= 63.48 kN
Permissible tensile stress 0.60 x Tnb /
=
of the bolt Asb
= 336.96 N/mm2
SAFE
D Shear
Maximum shear force at
support 21.8 kN
Shear force per bolt Vsb 10.90 kN
Actual shear stress in
Vsb/Asb
bolt fsb
10900
113.04
96.43 N/mm2
Nominal shear capacity
x (nnAnb + nsAsb)
of bolt Vnsb
52.21 kN
Permissible shear stress
0.6 x Vnsb/Asb
in bolt fasb
277.13 N/mm2
SAFE
E Check for Combined action
(fsb/fasb)2 + (ftb/fatb)2 96.43
+
63.48
= 0.536
277.13 336.96
< 1
SAFE
Hence use 2 M12 Grade 8.8 bolts for Hinge Connection.
F Design of Plate
100
Shear in each Bolt = 10.90 kN
Moment = 1.09 kN.m
Plate Length L = 270 mm
Plate Width W = 170 mm
Plate Thk Tp = 12 mm
C/s area ( W x Tp ) = 2040 mm
Z = Tp . W3
3
= 58956000 mm
Max. Stress in steel = (P/A) + (M/Z)
= 5.36 Mpa
Max. allowable Stress = 0.87 Fy
= 217.5 Mpa …( Fy for plate 250 Mpa)
SAFE