0% found this document useful (0 votes)
262 views11 pages

Nepal National Building Code: Provisional Recommendation On Fire Safety

This document is the Nepal National Building Code provisional recommendation on fire safety from 1994. It outlines some basic requirements for fire safety in building design, including requirements for fireplaces, fire extinguishers, fire zones, access provisions, exit requirements, and lightning arresters/conductors. The recommendations are meant to provide minimum fire safety standards but account for limitations in Nepal. It focuses on ensuring adequate exits from and access to residential buildings to protect from fire hazards.

Uploaded by

Sujan Lamichhane
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
262 views11 pages

Nepal National Building Code: Provisional Recommendation On Fire Safety

This document is the Nepal National Building Code provisional recommendation on fire safety from 1994. It outlines some basic requirements for fire safety in building design, including requirements for fireplaces, fire extinguishers, fire zones, access provisions, exit requirements, and lightning arresters/conductors. The recommendations are meant to provide minimum fire safety standards but account for limitations in Nepal. It focuses on ensuring adequate exits from and access to residential buildings to protect from fire hazards.

Uploaded by

Sujan Lamichhane
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 11

NEPAL NATIONAL BUILDING CODE

NBC 107 : 1994

PROVISIONAL RECOMMENDATION ON
FIRE SAFETY

NBC107V0.RV8 12 May 1994


His Majesty's Government of Nepal
Ministry of Physical Planning and Works
Department of Urban Development and Building Construction
Babar Mahal, Kathmandu, NEPAL
2060

NEPAL NATIONAL BUILDING CODE

NBC 107 : 1994

PROVISIONAL RECOMMENDATION ON
FIRE SAFETY

This publication represents a standard of good practice and therefore


takes the form of recommendations. Compliance with it does not confer
immunity from relevant legal requirements, including bylaws

>L % sf] ;/sf/ -dlGqkl/ifb\_ sf] ldlt @)^).$.!@ sf] lg0f{ofg';f/ :jLs[t

NBC107V0.RV8 12 May 1994


His Majesty's Government of Nepal
Ministry of Physical Planning and Works
Department of Urban Development and Building Construction
Babar Mahal, Kathmandu, NEPAL
2060

NBC107V0.RV8 12 May 1994


i

Preface

This Nepal Standard was prepared during 1993 as part of a project to prepare a draft National Building
Code for Nepal.

In 1988 the Ministry of Housing and Physical Planning (MHPP), conscious of the growing needs of
Nepal's urban and shelter sectors, requested technical assistance from the United Nations Development
Programme and their executing agency, United Nations Centre for Human Settlements (UNCHS).

A programme of Policy and Technical Support was set up within the Ministry (UNDP Project
NEP/88/054) and a number of activities have been undertaken within this framework.

The 1988 earthquake in Nepal, and the resulting deaths and damage to both housing and schools, again
drew attention to the need for changes and improvement in current building construction and design
methods.

Until now, Nepal has not had any regulations or documents of its own setting out either requirements
or good practice for achieving satisfactory strength in buildings.

In late 1991 the MHPP and UNCHS requested proposals for the development of such regulations and
documents from international organisations in response to terms of reference prepared by a panel of
experts.

This document has been prepared by the subcontractor's team working within the Department of
Building, the team including members of the Department and the MHPP. As part of the proposed
management and implementation strategy, it has been prepared so as to conform with the general
presentation requirements of the Nepal Bureau of Standards and Metrology.

The subproject has been undertaken under the aegis of an Advisory Panel to the MHPP.

The Advisory Panel consisted of :

Mr. UB Malla, Joint Secretary, MHPP Chairman


Director General, Department of Building
(Mr. LR Upadhyay) Member
Mr. AR Pant, Under Secretary, MHPP Member
Director General, Department of Mines & Geology
(Mr. PL Shrestha) Member
Director General, Nepal Bureau of Standards & Metrology
(Mr. PB Manandhar) Member
Dean, Institute of Engineering, Tribhuvan University
(Dr. SB Mathe) Member
Project Chief, Earthquake Areas Rehabilitation &
Reconstruction Project Member
President, Nepal Engineers Association Member
Law Officer, MHPP (Mr. RB Dange) Member
Representative, Society of Consulting Architectural &
Engineering Firms (SCAEF) Member
Representative, Society of Nepalese Architects (SONA) Member
Deputy Director General, Department of Building,
(Mr. JP Pradhan) Member-Secretary
ii

The Subcontractor was BECA WORLEY INTERNATIONAL CONSULTANTS LTD. of New


Zealand in conjunction with subconsultants who included :

Golder Associates Ltd., Canada


SILT Consultants P. Ltd., Nepal
TAEC Consult (P.) Ltd., Nepal
Urban Regional Research, USA

Principal inputs to this Standard came from :

Mr. YK Parajuli, TAEC


Mr. JR Pokharel, TAEC

Revisions and Updated to this code came from :

Mr. Purna P. Kadariya, DG, DUDBC


Mr. Kishore Thapa, DDG DUDBC
Mr. Mani Ratna Tuladhar, Sr. Div. Engineer, DUDBC
Mr. Jyoti Prasad Pradhan, Ex. DDG, DOB
Mr. Bhubaneswor Lal Shrestha, Ex. DDG, DOB
Mr. Uttam Shrestha, Architect, Architects’ Module Pvt. Ltd.
Mr. Manohar Lal Rajbhandhari, Sr. Structural Engineer, MR Associates
Mr. Amrit Man Tuladhar, Civil Engineer, DUDBC
iii

TABLE OF CONTENTS

Preface................................................................................................................................................ i

0 Foreword................................................................................................................................ iv

1 Scope...................................................................................................................................... 1

2 Interpretation........................................................................................................................ 1

2.1 General....................................................................................................................... 1
2.2 Terminology............................................................................................................... 1

3 Types of Construction and Appliances................................................................................ 1

3.1 Fire Places.................................................................................................................. 1


3.2 Fire Extinguishers..................................................................................................... 2

4 Fire Zones.............................................................................................................................. 2

5 General Requirements.......................................................................................................... 2

5.1 Provision of a Proper Access..................................................................................... 2


5.2 Provision of Wide Doors........................................................................................... 2
5.3 Provision of Fire Escape Ways................................................................................. 2
5.4 Provision of Open Space........................................................................................... 3

6 Exit Requirements................................................................................................................. 3

6.1 General Requirements.............................................................................................. 3


6.2 Number of Exits......................................................................................................... 3

6.2.1 Stairs.................................................................................................................. 3
6.2.2 Fire Escapes...................................................................................................... 3
6.2.3 Exit Doors......................................................................................................... 4

7 Access to a Building............................................................................................................... 4

8 Lightning Arresters/Conductors.......................................................................................... 4

9 References.............................................................................................................................. 4
iv

0. Foreword

0.1 This Standard covers the basic requirements for fire safety in the design of ordinary
buildings.

0.2 This Standard, with due consideration to the severe limitations on the issue of fire
protection in Nepali conditions, takes a modest approach. It deals only with the
minimum requirements of exits from and access to ordinary residential buildings from
the fire safety point of view. Designers are encouraged, wherever possible, to
incorporate higher levels of fire safety in their designs by following other relevant
reference, Standards or Codes.
1

1 Scope

1.1 This Standard provides fundamental requirements for fire safety in ordinary buildings.
These requirements do not necessarily cover the fire safety provisions needed for other
buildings. For the design of such other buildings, other relevant Codes and Standards
which might be followed have been suggested.

2 Interpretation

2.1 General

2.1.1 In this Standard the word "shall" indicates a requirement that is to be adopted in
order to comply with the Standard, while the word "should" indicates
recommended practice.

2.1.2 Commentary clauses are prefaced by the letter C and the number of the
appropriate clause subject to comment.

2.1.3 Words implying the singular also include the plural and vice-versa where the
context requires it.

2.2 Terminology

For the purpose of this Standard, the following definitions shall apply, unless
inconsistent with the context :

IMPORTANT BUILDINGS means those buildings which either house facilities


essential before and after disaster (eg, hospitals, fire and police stations,
communication centres, etc), or which by their very purpose have to house several
persons at one time (eg, cinema halls, schools, convention centres, etc), or will have
national and international importance (eg, palaces, etc), or which house hazardous
facilities (eg, toxic or explosive facilities, etc).

ORDINARY BUILDINGS are the buildings, which do not come under the category
of important buildings. They include commercial and office buildings.

3 Types of Construction and Appliances

3.1 Fire Places

All buildings having a kitchen should be provided with a fireplace and a chimney in
order to reduce the possibilities of the occurrence of accidental fire. Open hearths
should be discouraged and eliminated wherever possible. Timber construction should
not be placed near the fire place, nor should it remain exposed in the vicinity of fire.
Such surfaces should remain encased by plaster, whether of mud or other binders,
suitable for the purpose.

NBC107V0.RV8 12 May 1994


2

3.2 Fire Extinguishers

Occupants are encouraged to install appropriate portable fire extinguishers in their


building.

Where open hearth or kerosene stoves are used for cooking, sufficient water should be
stored in containers for emergency use in case of fire.

4 Fire Zones

In urban areas, the demarcation of fire zones should be carried out in consultation with the
relevant municipal authority as and when deemed necessary.

These shall conform to the requirements specified by the Department of Urban


Development and Building Construction or any other agency responsible for developing and
demarcating such fire zones.

5 General Requirements

All buildings shall be designed in such a way that they can contribute to the containment of a
fire and thus reduce its spread to other buildings.

5.1 Provision of a Proper Access

Every building should have an access as defined by Architectural Design


Requirements (NBC 206) and should be wide enouth to enable the fireman to easily
approach to the building site.

5.2 Provision of Wide Doors

The entry door shall be as defined by Architectural Design Requirements (NBC 206)
and should be sufficiently wide and tall so that easy access in available to the fire man.

5.3 Provision of Fire Escape Ways

All buildings should have sufficient ways as defined by Architectural Design


Requirements (NBC 206) so as to allow the rapid evacuation of all occupants in the
event of fire, if any. In addition to the main entrance, the side and/or rear entrance
shall be incorporated in the design.

The set back and/ or open space shall conform to the planning and building by-laws
adopted by the concerned and authorized territorial authority.

5.4 Provision of Open Space

The front entrance should have enough open space as defined by Architectural Design
Requirements (NBC 206) so that a number of people can gather and contribute in
extinguishing the fire, if any.

NBC107V0.RV8 12 May 1994


3

6 Exit Requirements

6.1 General Requirements

An exit normally shall consist of either a doorway, corridor or passageway to an


internal staircase, to an external staircase, to a verandah leading to the street, to the roof
of a building, or to the street. The exit may also lead to another building in the
neighbourhood. The exit should :

a) be able to allow the evacuation of all the occupants in a relatively short time;

b) meet the minimum requirements as to size;

c) be free of any obstructions and shall not provide any resistance to movement;

d) be clearly visible, preferably with proper signs;

e) be continuous and shall not intrude into private space.

6.2 Number of Exits

6.2.1 Stairs

The number of stairs in any building, especially when it exceeds 500 square
metres in plinth area, shall be a minimum of two, one internal and the other an
external fire escape. Additional stairs shall be provided in proportion to any
increase in the plinth area.

In the case of residential buildings, the minimum width of the stairs shall be 90
cm. For other buildings, the minimum width shall be 1.5 m. The distance
from any point in a passageway to a staircase in a building shall not exceed 20
metres.

6.2.2 Fire Escapes

Every building more than five storeys high shall have a separate fire escape
having a minimum width of 75 cm. The fire escape shall have a minimum
tread width of 20 cm and each riser shall be not more than 19 cm high. The
number of risers per flight shall not be more than 15. Such a fire escape shall
carry users towards an open space.

6.2.3 Exit Doors

Exit doors shall open to a passageway or to a corridor.

They should open outwards, but without restricting the movement of people
passing outside the door.

The maximum distance of such an exit doorway from any point in a passage
shall be 20 m.

NBC107V0.RV8 12 May 1994


4

The exit doorway shall neither be smaller than 90 cm in width, nor 180 cm in
height.

7 Access to a Building

It shall comply with all applicable zoning requirements and by-laws of the local planning and
building authority.

The access leading to a building should preferably be by a road at least four metres wide, and
no such road should lead to a dead end. The road should not have such sharp or restricted
turns that the passage of a fire engine is made difficult in the event of fire.

8 Lightning Arresters/Conductors

There have been many incidents in Nepal when lightning strikes have resulted in fire in
buildings and a consequential loss of life and property. The need to install lightning
arresters/conductors is therefore important.

A lightning arrester shall be located in the highest part of every building and it shall be
connected by a conductor to an earth rod buried in the earth. The lightning arrester shall be so
located that as much as possible of the building lies inside the surface of an imaginary cone
having a vertex angle of 45 degrees and its apex at the top of the arrester.

9 Referances

 National Building Code of India 1983, Part IV, Bureau of Indian Standards, New
Delhi.

 United Building Code (UBC), Part VII, Chapters 33 & 37, USA.

 MV Lisitsyan and EC Pronin, "Architectural Design for Dwelling Houses", Moscow,


1990 (available in Russian and English).

NBC107V0.RV8 12 May 1994

You might also like