Modbus RTU/ASCII To HART Gateway: Utility Features

The HRT-710 gateway allows a Modbus master device to communicate with HART slave devices like transmitters and actuators. It supports both HART short and long frames in point-to-point or multi-drop topology. The included utility software allows users to configure the gateway and map HART commands to Modbus addresses for easy integration of HART devices into a Modbus network.

Uploaded by

joao victor
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
104 views2 pages

Modbus RTU/ASCII To HART Gateway: Utility Features

The HRT-710 gateway allows a Modbus master device to communicate with HART slave devices like transmitters and actuators. It supports both HART short and long frames in point-to-point or multi-drop topology. The included utility software allows users to configure the gateway and map HART commands to Modbus addresses for easy integration of HART devices into a Modbus network.

Uploaded by

joao victor
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Modbus RTU/ASCII to HART Gateway

HRT-710
The HRT-710 Gateway is specially designed for the master device of HART protocol. It allows the
Modbus master device to access the HART slave devices. These HART devices may be a transmitter,
an actuator, a current output device and so forth. In addition, we also provide the utility software for
users to configure the HRT-710. By using this module, users can integrate their HART devices into
Modbus network easily.

Utility Features
Support HART Short/Long frame Read/Write HART device by HART command
Support HART Burst mode Provide diagnostic Information
Allow two HART Masters Read/Write module configuration of the HRT-710
Working in point-to-point or multi-drop HART mode Show Modbus address of HART command
Connecting up to 15 HART modules
Support Modbus RTU and ASCII format
Support Modbus Slave mode
Isolated COM 1: RS-232/422/485
Provide LED indicators
Built-in Watchdog
4KV ESD Protection

Modbus Support
Support the following Modbus commands. Pin Assignments

1
Hardware
Watchdog Watchdog IC
ESD Protection 4 kV class A
UART Interface
COM 1 RS-232(3 wire)/RS-422/RS-485
COM 1 Connector 9-pin screwed terminal block
Baud Rate (bps) 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Protocol Modbus RTU / Modbus ASCII
HART Interface
HART Channel 1
HART Interface 2-pin screwed terminal block
HART Device 2-wired or 4-wired HART devices
HART Topology Point to Point or Multi-Drop
HART Data Only Digital Data
HART Frame Type Short and Long Frame
Burst Mode Supported
Max. HART Device 15
Loop Resistor 250 Ω resistor by Jumper
Isolation Follow UL1577 Spec.
Power
Power supply Unregulated +10 ~ +30 VDC
Protection Power reverse polarity protection, Over-voltage brown-out protection
Power Consumption 1W
Mechanism
Installation DIN-Rail or Wall Mounting
Dimensions 72 mm x 35 mm x 121 mm (W x L x H) Detail
Environment
Operating Temp. -25 ℃ ~ +75 ℃
Storage Temp. -30 ℃ ~ +85 ℃
Humidity 5% ~ 95% RH, non-condensing

Applications

Ordering Information