AIR CONDITIONER
Use and Care Manual
FOR PAC-12000DB
Introduction
Thank you for choosing this air conditioner to provide you and your family with
all of the "Home Comfort" requirements for your home, cottage or office. The
appliance can be moved from room to room within you home and set-up in just
minutes.
It is a multi-functional room a i r exchanging, air-processing appliance, designed
to offer you the functions of: A i r Conditioning, Dehumidify, and Independent Fan.
This manual will provide you with valuable information necessary for the proper
care and maintenance for you new appliance. Please take a few moments and
read the instructions thoroughly. If properly maintained, your appliance will give
you many years of trouble free operation.
Electrical Specifications
1.All wiring must comply with local and national electrical codes and be installed
by a qualified electrician If you have any questions regarding the following
instructions, contact a qualified electrician.
2.Check available power supply and resolve any wiring problems before installation
and operation of this unit.
3.For your safety and protection, this unit is grounded through the power cord plug
when plugged into a matching wall outlet. If you are not sure whether the wall
outlets in your home are properly grounded, please consult a electrician. Do not
use plug adapters or extension cords with this unit If it is necessary to use an
extension cord with extension cord only. ( available at most local hardwarestores.)
Warning Improper handling can causeserious damagetotheappliance.
Readthismanualcarefully beforeoperating the unit.
Do not wet the housing or Do not cover the air Do not a llow children to play with
control panel. outlet while in use. the controls or drop any objects
into the air outlet.
Do not place objects or let Always turn the unit off and Do notattempt to remove any
any person sit on top of remove the power plug from part o f t h e c a s i n g unless by a
the unit. . The socket when cleaning. Authorised technician.
Remove the plug from the Use only the correct power Do not operate the unit with
socket if the unit is not supplyAC220V-240V/50Hz damaged plug or loose
being used for long period. socket point.
Make sure that the back o f t h e unit is at least 10cm or more from a wall.
Do not place the unit in front of curtains or drapes incase they fall against the
back air intake.
WARNING
If the power cord on this unit is damaged it must be replaced by the
manufacturer﹐its service agent or qualified persons in order to avoid
a hazard﹒
This appliance is not intended for use by children or other persons
without assistance or supervision if their physical, sensory or mental
capabilities prevent them from using it safely. Children should be
supervised to ensure that they do not play with the appliance.
Identification of parts
Identification of parts
Transparentcovertothecontrolpanel
Air outlet
Mountingbrackets(with screws)......2
Handlehole
Spanner........................................2
Front panel Wall plugs(withscrews)..................4
Support belt with hook....................2
Caster Frame for flexible connecting h o u s e 1
Protective cap for connector(M).......2
(F).......2
Screenfilter.
Airintake.
Handlehole
Outdoorunit's
mounting screw.
Covertoumbilical
connection.Always
keepcoveron.
Water drainage pipe
and pipe plug.
Power cordcompartment
Operation
Timer On / Off
WarningLight Display
Power Control
Mode Control
Timer / Temp
Fan Speed Control Set Controls
Power Control ● Fan Mode
The power control turns the unit on and off. When fan mode is selected the indicator light will
shine yellow. Air is circulated throughout the room
with no cooling.
Warning Light Note: unit does not need to be vented in Fan mode
Condensed water may accumulate in the unit. If
the internal tank becomes full, the Warning Light
will shine and the unit will not operate until the Fan Speed Control
unit has been drained. The Fan Speed Control has 3 settings: High,
Medium, and Low.
Mode Control
The Mode Control has three settings: Timer
● Cool ● Dehumidify ● Fan Auto turn off :
The settings are adjusted with Mode Control With machine in fan mode, press timer button to
button. A light will indicate which setting is select number of hours you would like the unit to
currently being used. run in air conditioning mode until it automatically
shuts off.
● Cooling Mode Auto turn on :
When cool mode is selected, the indicator light With machine powered off , press timer button to
will shine green. During the cooling mode the select number of hours until you would like the unit
air is cooled and hod air is exhausted to the to automatically start running in air conditioning mode.
outside air through the exhaust tube.Adjust fan
speed air through the temperature to suit your Timer / Temp set controls
desired comfort level. ● Used for adjusting the timer and thermostat.
Note : The air exchange hoses must vent ● The default display is room temperature.
outside the room when using cool mode. ● In cooling mode, when " ▲ " or " ▼ " button is pressed,
the set temperature is displayed and may be adjusted.
● Dehumidify Mode After 15 seconds the display will revert back to room
When dehumidify mode is selected, the indicator temperature. Temperature is only adjustable in cool
light will shine orange. Air is dehumidified as it mode. The time is adjustable between 1~12 hours.
passes through the unit, without being in full Note : By pressing both Timer / Temp set buttons at the
cooling mode. The fan will operate inmed speed. same time, the display will toggle between Celsius and
Fan speed is not adjustable in dehumidify mode. Fahrenheit.
Note : The air exchange hoses must vent inside
the room when using dehumidify mode.
After switching the air conditioner off, you must wait 3 minutes before switching it b ack on again.
Operation
(OPTION)
Air Conditioner Remote Control
The functions work the same as your air conditioner's touch controls.
: lamp is on whenin
cooling mode
On/Off
: lamp is on whenin
dehumidification mode
ON/OFF Mode
:lampisonwhenin
fan mode
FanSpeed Up
:HIGH :MED :LOW
Timer / Temperature Keys
Timer Down
● Used for adjusting the timer and
temperature.
● The default display is room temperature.
● -
When " + " or " " key is pressed,
the set temperature is displayed and
may be adjusted. After 15 seconds the
Inrunningmode: display will revert back to room
Auto switchoff temperature.
Instandby mode: ● Timer setting is available from 1-12 hours
Auto switchon by pressing the key "+"on " - ".
Battery replacement : Remove the cover on the back of the remote control and insert the batteries with the
( + ) and ( - ) poles pointing i n the proper direction.
CAUTION
Use only AAA or IEC R03 1.5V batteries.
Remove the batteries if the remote control is not used for a month or longer.
Do not attempt to recharge the supplied batteries.
All batteries should be replaced at the same time, do not mix old battery .
Do not dispose of the batteries in a fire as they may explode.
Remove and connection
of the quick connector This procedure should be carried out by a professional
person to avoid expensive mistakes.
6.Use the 2spanners provided to
Steps in disassembly disconnect the 2 pipes.
1.Turn off the air conditioner, a n d Caution
remove the plug from thepowersuck. Make sure the tubes and connectors
are kept level while disconnecting
Caution to avoid coolant leaking.
Upon turning off the air conditioner,
leave it idle for at least 30 minutes;
the disassembly can then be
implemented after the system has
been stabilized.
7.Screw the protective caps onto the
ends after disconnection of each
pipe.
8.Separate the clamping tie on the
black water pipe. Graduallyrelease
the water pipe and place your finger
2.Use a philips-head screw driverto over the end to prevent water in the
remove the cover. tube coming out. Have a container
ready to collect any excess water
from the tube.
3.Disconnect the electrical connector
by pressing clip holders.
Steps in connection
Always remember to keep the
connecting pipes level with the
connecting point when
re-assembling.
4.Remove the metal holding brackets. Caution
When re-connecting the unit follow
the above steps in reverse.
Use your fingers to connect the
threads and then tighten with
spanners provided.
5.Remove the insulating foam around After connection please use soap
the upper connector. suds to check for leaks in the coolant
pipe.
Please remember this procedure must
be followed each time.
Installations IMPORTANT: Do not have any sharp bends or twisting
it the umbilical cord.
For permanent installation follow instructions.
If you are not sure contact a service company.
The Indoor Unit
METHOD I :
The umbilical cord can pass through partly open door or window.
Caution
The location of the indoor unit must have at
lease 1 0 c m s p a c e a t t h e r e a r a n d a w a y
from curtains/drapes.
METHOD II :
The umbilical cord can pass through a hole in the window or the window frame were a gap
has been shaped out.
Caution
When u sing the later use the plastic frame
supplied. When the air conditioner is being
stored a way cap can be placed over the
frame t o s e a l t h e h o l e o f f .
METHOD III :
For fitting through a hole in the wall disconnect the umbilical cord as described on page 8
a and p a s s ! Cord through the hole from the outside. Use the plastic frame for theumbilical
cord when using method.
Caution
If you a re not sure or happy disconnecting
and reconnecting the cord contact a local
service person.
Remember to use soap suds to check for
refrigerant leaks after connection each time.
Warning
Each time you bring the outdoor unit inside always turn the air conditioner off at t h e power
supply. If you do not and move the inside unit the dehumidified water in the container inside
the unit could activate the water pump and discard water from the tube on outdoor unit.
The Outdoor Unit
METHOD I :
The outdoor unit may be placed on outdoor patio or flower planer directly, thus it d o e s n o t
require using the special mounting brackets.
Caution
Please make sure that the drainage pipe is
not pressed by the outdoor unit!
METHOD II :
The outdoor unit may be mounted on the wall by utilizing the enclosed accessories
(mounting brackets, wall plug and the screws).
Caution
When u sing this method you can extend
the drainage tube and direct it to w e r e you
wish the water to discharge. You can lift
the outside unit off the brackets at any time.
If you intend a permanent fitting for the
outside unit we recommend to make a
cover for it to prevent water getting inside
in heavy rains.
METHOD III :
For short-tem application, please use the enclosed belts to hang the outdoor unit outside
the window.
Caution
With this method we recommend in heavy
rain storms and wind to tun the unit suitably
covered.Always use the belts on the
mounting brackets, do not tie belts on
handle.
Troubleshooting Amajority of malfunctions are minute, and
triggered by problems that can easily be resolved;
before calling for service, please refer to the
following table for sequential inspection.
PROBLEM CAUSES RESOLUTIONS
Air conditioner stops Power failure. Wait for the power to come
operating back on.
The plug has not been plugged Insert the plug.
in.
The timer setting dial has not Set the timer setting dial to
been set. proper position.
The fan speed control dial has Set the fan speed control d ail
not been set. to correct position.
The warning light is on the Turn all switches off and w a i t
internal safety switch has been 5 mins and turn on again, if
activated. still not working contact place
of purchase.
Air conditioner stops The indoor t emperature has Reset the temperature.
in the middle of the reached the designated
operation. temperature.
The designated operating time Reset the timer.
is up.
The warning light is on the Contact the service center.
unit's internal safety switch
has been activated.
Air conditioner pauses on The outdoor unit's electrical Disconnect power and take
and off irregularly. connector has not been umbilical cover off to check
connectedsecurely. if electrical connector is firm.
Malfunction. If thiskeepshappening call
the distributor.
Air conditioner functions Window or d oor is left open in Close all window and door.
but the room is not cooled. the room.
Heat source in the room or Eliminate heat source.
excessive n u m b e r o f p e o p l e in
it.
Saturated filter. Clean the filter.
Temperature setting too high. Lower the temperature
setting.
Motorrunning sound The water p u m p i s e m p t y i n g This will automatically stop in
when unit has turned off. excess water from the a few minutes.
container inside the unit.
Troubleshooting
Appliance maintenance Air filter maintenance
Cut off the power supply It is necessary to clean the air filter
after using it for about 100 hours.
Turn off the appliance Clean it as follows:
first before disconnecting
from power supply Stop the appliance and
remove the air filter.
Wipe with a soft
ant dry cloth.
Stop the appliance
Uselukewarm water
first, then pull back
(below 40℃) toclean the air filter.
the appliance is verydirty.
Never use volatile substance
such as gasoline or polishing Clean and reinstall the air filter
powder to clean the appliance. If the dirt is conspicuous,
wash it with a solution of
detergent in lukewarm water.
After cleaning, dry it in a
shaded and cool place, then
reinstall it....
Never sprinkle water onto the
main unit.
Clean the air filter every two weeks
Dangerous! If the air conditioner operates in an
Electric extremely dusty environment.
shock!
Maintenance after using
1.If the appliance will not be used for a long time, be sure to Pull out the rubber
plug of the drain port underside, in order to drain the water.
2.Keep the appliance running with fan only for a half day in a sunshiny day to
dry the appliance inside and prevent form going moldy .
3.Stop the appliance and pull out the power supply plug, then take out the
batteries of remote controller and keep it well.
4.Clean the air filter and reinstall it.
5.Remove the air hoses and keep them well, and cover the hole tightly.
Specifications
Figures noted, in the contents are for reference only; variation may result due to application in
different countries or regions, and shall be based o n t h e best of practical operation.
Description of p roduct Air Conditioner
Model PAC-12000DB
Voltage/Frequency AC 220-240V / 50Hz
Input power 1400 W
Operating cycle 6.4 A
12000 B.T.U.
Cooling capacity
3.5 kW
Dehumidifying capacity 2.0 L/hour
Coolant R-407C
Timer 12 h o u r
3
Air flow volume 380 m /hour
Dimensions Indoor unit 52.4cmX 89.7cmX 34.7cm
(W) X(H)X ( D )
Outdoor unit 44cmX 48cmX 30cm
Indoor unit 36 kgs
Weight (N.W.)
Outdoor unit 13 kgs
"Waste electrical products should not be disposed of with household waste.