MOMENT CONNECTIONS
PROJECT : CHERAT CEMENT CO. LTD.
DEPARTMENT : COAL MILL.
ELEVATION :
MEMBER # : A1 (Typical Connection)
SECTION PROPERTIES:                                                      NOTE:      Cells in                  to be input by the user.
                                              inches          mm                    All units are FPS except mentioned.
Total Depth                         h         10.827          275
Width of Flange                    bf          5.315          135
Flange Thickness                    tf         0.394           10
Web Thickness                      tw          0.236            6
Gross Moment of Inertia            Ig         133.856      55715062.5
VALUES FOR ANALYSIS:                                                                                  M   =     52.88     KN-m
                                                                                                      V   =     35.58     KN
Moment                              M          39.00
Shear                               V          8.00                       if Vu < 6 k, use Vu = 6 k
Allowable Stresses                  Ft         19.14
Shear Capacity (Single)          V (cap)       7.51      refer. 'AISC' Table I-D
Ultimate Tensile Stress            Fu           58
CHECK FOR STRESSES:
FLANGE
Diameter of bolts (req.)             d          0.79                    Diameter of bolts (provided) =           0.75
Gross Area of Flange            Af (gross)   2.09250419
Net Area of Flange               Af (net)    1.43974828
% Loss                              %L          31.19
Excess Loss from 15%                 L          16.19   refer. 'AISC' Manual P5-30
Net Moment of Inertia             I (net)    115.412589
Section Modulous                 S (net)        21.32
Stresses                             fb         21.95   SAFE!
Tension in Flange                    T       43.2250735
FLANGE PLATE
Area of Plate (required)         A(req.)        2.26                     Thickness of Plate (pro.) =              1
Width of Plate (required)        b(req.)        3.88                     Width of Plate (prov.)   =             5.315
Area of Plate (net)              A(net)         3.69                     Area of Plate (provided) =             5.31
check for 15% reduction due to holes:           4.52     SAFE!
CONNECTIONS:
a) Flange connection
No. of Bolts (required)             n           5.76
                                                              Page 1 of 2
b) Web connection                                                                 Shear cap.(Double) =       15         ref. 'AISC' Table I-D
                                                                                  Single bolt load cap.=    29.4        ref. 'AISC' Table I-F
No. of Bolts (required)                      n       0.53                         Diameter of Bolts =       0.75
                                                                                  No. of Bolts (prov.) =      2
Load cap. = No.of bolts prov.x tw xsingle bolt load cap.=          13.89          SAFE!
IF SHEAR CONNECTION PROVIDED WITH CLEAT ANGLES:
ANGLE LEG LENGTH:
a) for leg connected with beam web
                                                                                  Edge distance    =         1.5
leg length = gauge + edge distance           =        4                           Gauge length     =         2.5         ref. 'AISC' Table
                                                                                  Angle th.        =       0.3125         II-A & II-C
                                                                                  Nut th.          =        0.75
b) for outstanding leg connected to col. Flange
leg length = angle th. + washer th. + nut th. + bolt projection + wrench clearance +edge dist. =           4.4375
Check Allowable Shear Force in connection Angles:
From AISC Table II-C :
Allowable Shear Force =                  194      SAFE!
If beam is coped :
From AISC Table I-G :                   C1 =          1.7
                                        C2 =         2.96
                                        Rbs =     63.8456693 SAFE!
IF SHEAR CONNECTION PROVIDED WITH WELDED PLATE:
DESIGN OF PLATE WELDED AT ONE END & BOLTED AT OTHER:
Thickness of Plate:
     tp (req.) = (tw + 1/16)/2 =        0.149                           tp (provided) =           0.394
Length of Plate:
0.3 x Fu x A (net) > Vu (max)          (i)
where,
A (net) = Ag (plate) - Ag (holes)
                     Ag1 (holes) =      0.296                 for one bolt only
                     Ag2 (holes) =      0.591                 for two bolts
                     Ag3 (holes) =      0.591                 for no. of bolts
                     Ag (plate) =       bp x tp
using above relation ( i ) , we have
                          A (net) =     0.230
That is
           bp x tp - Ag(holes) =        0.230
therefore,
                             bp1 =      1.333                 use this length when only single bolt is in shear plane
                             bp2 =      2.083                 use this length when two bolts are in shear plane
                             bp3 =      2.083                 use this length when all bolts are in shear plane
Therefore, providing two plates of
                                                                   Page 2 of 2