SILT FACTOR calculations
Silt Factor is determined as per IRC : 78. Representative samples have been taken at regular
interval of 1.5 m or change of strata. For the purpose of silt factor computation, the
weighted mean diameter of particles for representative sample of each stratum encountered
up to the maximum anticipated scour depth has been determined.
Silt Factor Ksf = 1.76 x (dm)1/2.
dm = Mean Particle Size.