H1.
25 Batching Plant Lubrication Plant
Compressor
Make Elgi
Oil Quantity 750ML
Recommended Oil ELGI AIR LUBE
KW/ HP 7.5 / 10
First Change 150 RUNNING HOURS
SUBSEQUENT OIL CHANGE SHOULD BE EVERY 500 WORKING HOURS OR EVERY
Subsequent Change MONTH.
FRL UNIT
Oil Quantity 150ML
Recommended Oil VG 32
Subsequent Change WHENEVER THE OIL LEVEL IS LOW
Screw Conveyor
Make WAM (219 Dia Cement screw)
Oil Quantity 1.8 Liters 75% of gear box sight glass level.
Recommended Oil VG 220 MINERAL OIL (Refer the operating & maintenance manual for oil brand)
KW/ HP 11 KW 15HP
First Change FIRST OIL CHANGE SHOULD BE 500 RUNNING HOURS
Subsequent Change SUBSEQUENT OIL CHANGE SHOULD BE 2500 OPERATING HOURS.
Weighing Belt Conveyor
Make NORD
Oil Quantity 21.5Liters
Recommended Oil VG 220 MINERAL OIL (Refer the operating & maintenance manual for oil brand)
KW/ HP 15KW / 20HP
First Change 100 HOURS
Subsequent Change SUBSEQUENT OIL CHANGE SHOULD BE 1000 OPERATING HOURS OR YEARLY ONCE
SKIP
Make SEW
Oil Quantity 25LITERS
Recommended Oil VG 220 MINERAL OIL (Refer the operating & maintenance manual for oil brand)
KW/ HP 18.5KW /25HP
First Change 100 HOURS
Subsequent Change SUBSEQUENT OIL CHANGE SHOULD BE 3 YEARS ONCE
Stetter Mixer
Make ACMotoren
Oil Quantity 24.25 LITERS Each Gear Box total 48.5 liters (75% of gear box sight glass level).
Recommended Oil ISO VG 220 Synthetic oil
KW/ HP 45KW /60HP
First Change 400 HOURS
Subsequent Change EVERY 4000 WORKING HOURS OR 24MONTHS WHICHEVER IS EARLIER
Admixture Dosing & Discharge Pump.
Make ANALA
Oil Quantity 50% OF SHAFT LEVEL 100ML (APPROX)
Recommended Oil SAE 20W 40
KW/ HP 0.75KW / 1HP
First Change 100 HOURS
Subsequent Change 6 MONTH ONCE / Top up oil if required.
GREASING FOR MIXER AND PLANT
RECOMMENDED GREASE SHELL ALUVANIA RL2 , ARAL ARALUB HL2, BP ENERGREASE LS2 ,MOBIL MOBILUX EP2.