Sensor Product Guide

Smart Sensing Control Solutions


Service and Support During Every Step of the Process.
Only Leviton has the service and support to help you create a lighting control system that
does exactly what you want it to do while saving electricity, meeting codes and standards,
and even garnering rebates.

Exclusive SUPPORT Resources:


• Occupancy sensor layout services – have a team of experts create occupancy sensor layouts at no cost
to you directly on your CAD drawings, complete with a List of Equipment within an average turnaround time of
3 business days*— go to portal.leviton.com

• Dollars & Sensors™ – get an accurate estimate of your energy-savings potential with this exclusive payback
analysis tool— go to www.dollarsandsensors.com

• ez-Learn – get sensor smart in just 90 minutes from the comfort of your home or office with this exclusive 24/7
online training — go to www.leviton.com/ezlearn

• Lighting control specialists at your disposal

• Field service engineers for top-level support

• Factory commissioning service

• Dedicated technical support via phone at 800 959-6004

* Average turnaround time based on projects for up to 200 sensors per system.
Sensing Control

2
WIRELESS SELF-POWERED SENSORS
LevNet RF 902 MHz Wireless Self-Powered Sensors are part of LevNet RF’s complete line of self-powered solutions. The
occupancy sensors have built-in solar cells that draw on available ambient light within a space to power themselves and can
operate for up to 72 hours in total darkness. The self-powered sensor design also overcomes the placement and coverage
challenges of traditional sensors. Self-powered sensors enable flexible placement, allowing sensors to be mounted wherever
needed without the complexity of moving or installing new wiring.

COMMERCIAL GRADE
Energy Harvesting Wireless Solutions
Description Cat. No. Coverage Color
LevNet RF 902 MHz Low Profile Self-Powered

360°, 1200SF
WSC12-M9N
PIR Ceiling Mount Occupancy Sensor (111.48SM) WSC12
W
LevNet RF™ 902 MHz Self-Powered 180°, 1600*SF
WSWDR-H9W
PIR Wall Mount Occupancy Sensor (148.64SM)
*Multiple lenses included, see data sheet for more coverage information
Requires a LevNet RF load receiver device to operate

Sensing Control | Self-Powered Wireless


TOP VIEW
15

LONG RANGE
Top View
10
77°

22 ft (6.7 m) 21.5° 14°


6.5°
0 11 ft (3.4 m) 27°
0 Center
Line
11 ft (3.4 m)
10
WSWDR
22 ft (6.7 m)

3 ft 7 ft 25 ft 35 ft 100 ft 150 ft
(1 m) (2.2 m) (7.6 m) (10.7 m) (30.48 m) (45.7 m)
15

Minor Motion
Side View
SIDE VIEW Major Motion
10 6-8 ft
(2.1 -2.4 m)

0 3 ft 7 ft 25 ft 35 ft 100 ft 150 ft
(1 m) (2.2 m) (7.6 m) (10.7 m) (30.48 m) (45.7 m)
16 14 11 9 4 3 0 3 4 9 11 14 16

WSC12 Field of View (in feet) WSWDR Field of View (in feet)

Leviton sensors meet the following applicable agency listings: UL, cULus, ETL, CSA and NOM.
See product data sheets for specific listings.

www.leviton.com/sensors 3
Decora® Residential Grade Wall Switch Infrared Occupancy and Vacancy Sensors
Description Cat. No. Color Rating
Decora Wall Switch PIR Occupancy Sensor, Single-Pole,
IPS02-1L W, I, T 300W Incand/FL Ballast
180° Field of View, 900SF (83.61SM) coverage
150W LED/CFL,
Decora Wall Switch PIR Vacancy Sensor, Single-Pole, 1/6 HP Motor
IPV02-1L W,T
180° Field of View, 900SF (83.61SM) coverage
Decora Wall Switch PIR Occupancy Sensor, Single-Pole,
IPS05-1L 600W Incand/FL Ballast
180° Field of View, 900SF (83.61SM) coverage
Z 150W LED/CFL, IPS05-1L
Decora Wall Switch PIR Vacancy Sensor, Single-Pole, 1/6 HP Motor
IPV05-IL
180° Field of View, 900SF (83.61SM) coverage
Decora Wall Switch PIR Occupancy Sensor, Single-Pole or 3-Way,
IPS06-1L W
180° Field of View, 900SF (83.61SM) coverage
Decora Wall Switch PIR Dimming Occupancy Sensor, 600W Incandescent,
IPSD6-1L
Single-Pole or 3-Way, 180° Field of View, 900SF (83.61SM) coverage 150W LED/CFL
Decora Wall Switch PIR Dimming Vacancy Sensor,
IPVD6-1L
Single-Pole or 3-Way, 180° Field of View, 900SF (83.61SM) coverage
Z
Decora Wall Switch Relay Occupancy Sensor, Single-Pole or 3-Way, 1800W Incandescent,
IPS15-1L
Sensing Control | Wall Switch Residential

180° Field of View, 900SF (83.61SM) coverage, neutral required 600W LED/CFL,
Decora Wall Switch Relay Vacancy Sensor, Single-Pole or 3-Way, 1800VA 30ft
Fluorescent Ballast,
IPV15-1L 1/2 HP 9.1m
180° Field of View, 900SF (83.61SM) coverage, neutral required IPVD6-1L
Sensor Remote, 120V AC, Manual-ON, Auto-OFF for use with 5ft 6ft
1.5m—
IPV0R-1L No1.8m
Load Rating
IPS15 or IPV15 Sensor
Z — Comes packaged with three colors: White, Ivory and Light Almond.
6ft 5ft
Leviton sensors meet the following applicable agency listings: UL, cULus, ETL, CSA and NOM. 1.5m
1.7m
See product data sheets for specific listings.

Visit www.leviton.com/sensors for more information.

30ft
Decora® Residential Grade Wall Switch Humidity Sensor
9.1mand Fan Control
Description Cat. No. Color Rating
600W Incandescent, 150W LED/CFL
Humidity Sensor & Fan Control IPHS5-1L W, I,T
400VA MLV/Fluorescent, 1/6 HP (3A) Fan

30ft
9.1m
5ft 6ft
1.5m 1.8m

5ft
IPHS5-W
6ft
1.7m 1.5m

27ft
8ft 8.4m
2.6m
6ft
30ft 1.7m
9.1m
7ft
4ft 2.1m
1.2m

5ft 4ft
1.5m 30ft 1.4m
9.1m

Field-of-View (Horizontal) Field-of-View (Side, Vertical)


27ft
8ft 8.4m
2.6m
6ft
1.7m
7ft
4ft 2.1m
1.2m

5ft 4ft
4 1.5m 30ft 1.4m
9.1m
Decora® Commercial Grade Wall Switch Infrared Occupancy and Vacancy Sensors*
Description Cat. No. Color ** Rating Coverage
Incandescent: 600W @ 120V,
Fluorescent: 800VA @ 120V
Decora® Wall Switch PIR Occupancy Sensor ODS06-ID W, I 1500VA @ 277V,
50/60Hz
Motor: 1/4 HP @ 120V
Incandescent: 3470W @ 347V
Decora® Wall Switch PIR Occupancy Sensor Fluorescent: 3470W @ 347V
ODS10-I3 W
347V Only Model 50/60 Hz
Motor: 1/4HP @ 347V
Decora® Wall Switch PIR Occupancy Sensor ODS10-ID W, I, T, G, E, R Incandescent: 800W @ 120V
Fluorescent: 1200VA @ 120V,
Decora Wall Switch PIR Vacancy Sensor
®
ODS10-TD W, I, T 2700VA @ 277V.
Decora® Wall Switch PIR - Occupancy Sensor 50/60Hz
ODS10-IQ W, I, E 180°, 2100SF
Auto-ON/Auto-OFF Only Model Motor: 1/4HP @ 120V
(195.10SM)
Decora® Wall Switch PIR Occupancy Sensor with Incandescent: 1800W @ 120V
ODS15-ID W, I, T, G, E
Self-Adaptive Technology Fluorescent: 1800VA @ 120V,
4000VA @ 277V
Decora® Wall Switch PIR Vacancy Sensor with

Sensing Control | Wall Switch Commercial


ODS15-TD W, I, T 50/60Hz
Self-Adaptive Technology
Motor: 1/4HP @ 120V
Primary Relay–Fluorescent:
1200VA @ 120V, 2700VA @
Decora® Dual-Relay Wall Switch PIR Occupancy 277V;
Sensor with Self-Adaptive Technology. Incandescent: 800W @ 120V.
ODS0D-ID W, I, T, G, E, R
Default setting = Conference Room Mode*** Secondary Relay–Fluorescent:
Alternate setting = Classroom mode**** 800VA @ 120V, 1200VA @ 277V;
Incandescent: 800W @ 120V.
50/60Hz
Decora® Wall Switch PIR Occupancy Sensor with Incandescent: 800W @ 120V
OSSNL-ID W, I, T, G, E
LED Night Light Fluorescent: 1200VA @ 120V,
180°, 1200SF
2700VA @ 277V
Decoraç Wall Switch PIR with LED Night (111.48SM)
OSS10-IN W, I, E 50/60Hz
Light, CA Title 24 - Vacancy Model
Motor: 1/8 HP @ 120V
Protective Cage for Wall Switch Sensors OSWWG-P0W — — —
*Consult with factory for 208, 220, 230, and 240V load ratings.
**Add to end of catalog number suffix for color of switch: White (W), Ivory (I), Light Almond (T), Gray (G), Ebony (E) and Red (R) available on select models.
Wallplates sold separately.
***In Conference Room Mode, both primary and secondary relays respond to ambient light override.
****In Classroom Mode, primary relay responds only to ambient light override
Leviton sensors meet the following applicable agency listings: UL, cULus, ETL, CSA and NOM. See product data sheets for specific listings.

Decora® Wall Switch - Lev-Lok® Models, 20A


Description Cat. No. Color Rating
Decora® Wall Switch PIR Occupancy Sensor -
MDS10-ID Incandescent: 800W @ 120V.
Lev-Lok® Model
Fluorescent: 120VA @120V, 2700VA @ 277V.
Decora® Wall Switch PIR Occupancy Sensor - 50/60Hz Motor: 1/4HP @ 120V
MDS15-ID
Lev-Lok® Model W,I,T,G,E
Incandescent/Tungsten: 800W @ 120V.
Decora® Wall Switch Multi Technology Occupancy
MSSMT-GD Fluorescent: 1200VA @ 120V,
Sensor with No Netural - Lev-Lok® Model
2700VA @ 277V. 60Hz Motor: 1/4HP @ 120V

Wiring Modules for use with Lev-Lok® Sensors


Description Cat. No. Color
Stranded MSPSW-XST Yellow
Solid MSPSW-XSD Yellow

ODS06-INW/ODS06-IDW OSSNL-IDW ODS0D-IDW


ODS10-IDW/ODS15-IDW

www.leviton.com/sensors 5
DECORA® MULTI-TECHNOLOGY WALL SWITCH OCCUPANCY AND VACANCY SENSORS
Decora® Commercial Grade Wall Switch Multi-Technology (PIR & U/S) Occupancy and
Vacancy Sensors*
Description Cat. No. Color Rating Coverage
Decora Wall Switch Multi-
®

Technology Occupancy
OSSMT-MD W, I, T, G, E, R
Sensor with Self-Adaptive
Technology
Decora® Wall Switch Multi-
Technology Vacancy Sensor OSSMT-TM W, I, T
with Self-Adaptive Technology Incandescent/Tungsten:
800W @ 120V
Decora Wall Switch Multi- Fluorescent: 1200VA @ 120V,
Technology Occupancy 2700VA @ 277V OSSMT-MDW/OSSMT-GDW
Sensor with No Neutral - OSSMT-GQ Motor: 1/4HP @ 120V
Auto-ON/Auto-OFF Only 50/60Hz
Model
W, I, E
Decora® Wall Switch Multi-
Technology Occupancy
Sensing Control | Wall Switch Commercial

Sensor with Self-Adaptive OSSMT-MQ


Technology - Auto-ON/Auto-
OFF Only Model
Decora® Wall Switch Multi- Incandescent/Tungsten:
Technology Occupancy 800W @ 120V 180°, 2400SF
Sensor with Self-Adaptive OSSMT-M3 W, I Fluorescent: 1200VA @ 120V, (222.97SM)
Technology - 347V Only 2700VA @ 277V, 1500VA @347V
Model Motor: 1/4HP @ 120V
Decora® Wall Switch Multi-
Technology Occupancy Incandescent/Tungsten:
OSSMT-GD W, I, T, G, E, R
Sensor with no neutral wire 800W @ 120V.
required for installation Fluorescent: 1200VA @ 120V,
Decora® Wall Switch Multi- 2700VA @ 277V. OSSMD-MDW/OSSMD-GDW

Technology Vacancy Sensor OSSMT-GT W, I, T Motor: 1/4HP @ 120V, 50/60Hz


with No Neutral
Decora® Dual-Relay Wall Primary Relay —
Switch Multi-Technology OSSMD-MD Fluorescent 1200VA @ 120V,
Occupancy Sensor 2700VA @ 277V
Incandescent: 800W @ 120V
Decora® Dual-Relay Wall W, I, T, G, E Secondary Relay —
Switch Multi-Technology Fluorescent: 800VA @ 120V,
Occupancy Sensor with no OSSMD-GD 1200VA @ 277V;
neutral wire required for Incandescent: 800W @ 120V TOP VIEW
installation Motor: 1/4HP @ 120V, 50/60Hz 30
TOP VIEW
Protective Cage for Wall
OSWWG-P0W W — 30 —
20
Switch Sensors
*Consult with factory for 208, 220, 230, and 240V load ratings. TOP VIEW 20
Leviton sensors meet the following applicable agency 30
0
listings: UL, cULus, ETL, CSA and NOM. See product
data sheets for specific listings. 20
0

20

0 20 30
SIDE VIEW
5
30 4
0
20 SIDE VIEW 0 20 40
5
4
0
30 0 20 40
Major Motion, PIR Major Motion, U/S
Major Motion, PIR Major Motion, U/S
SIDE VIEW
5
4 Major Motion, PIR Major Motion, U/S
0 Major Motion, PIR Major Motion, U/S
0 20 40
OSSMD/OSSMT/MSSMT
Field of
Major Motion, PIR View
(in feet)
Major Motion, U/S
Major Motion, PIR Major Motion, U/S

6
LINE VOLTAGE OCCUPANCY/VACANCY SENSORS
Self-Contained Infrared Ceiling Mount Occupancy Sensors
Description Cat. No. Color Rating Coverage
Incandescent: 1000W @ 120V
Self-Contained Ceiling Mount
Fluorescent: 1000VA @ 120V
PIR Occupancy Sensor and ODC0S-I1W
Motor: 1HP @ 120V
Switching Relay, 120V
50/60Hz
Self-Contained Ceiling Mount Incandescent: 1000W @ 220V 360°, 530SF* ODC0S-I1W
W
PIR Occupancy Sensor and ODC0S-I2W Fluorescent: 500VA @ 220V (49.23SM)
Switching Relay, 220V For 50Hz AC only.
Self-Contained Ceiling Mount
Fluorescent: 2700VA @ 220V
PIR Occupancy Sensor and ODC0S-I7W
50/60Hz
Switching Relay, 277V

Protective Cage for


ODCCG-000 — — —
Ceiling Mount Sensors
ODCCG-000
*When surface mounted on standard, 8 foot ceiling.
Leviton sensors meet the following applicable agency listings: UL, cULus, ETL, CSA and NOM.
See product data sheets for specific listings.

Sensing Control | Line Voltage


Field of View (in feet)

TOP VIEW
13

13

SIDE VIEW
8

0
13 7 3 0 3 7 13

ODC0S-xx
Field of View (in feet)

www.leviton.com/sensors 7
LINE VOLTAGE SENSORS
Line Voltage Sensors with OPB15 Power Base Adaptor Combos
Description Cat. No. Color Rating Coverage
Line Voltage Wall Mount
1200SF
Multi-Technology Occupancy ODW12-MDW
(111.48SM)
Sensor with Power Base Combo
Line Voltage Wall Mount PIR
115°, 2500SF
Wide View Occupancy Sensor ODWWV-IDW
15A Incandescent, (232.26SM) ODW12-MDW
with Power Base Combo
Electronic or Magnetic
W Fluorescent Ballast 55ft., 7ft side
Line Voltage Wall Mount PIR
Motor: 3/4 HP @ 120V, @ 30ft high
Wide View Occupancy Sensor ODWHB-IDW
277V @ 2HP (16.76m x 2.13m
with Power Base Combo
side @ 9.14m high)
100ft, 110°
Line Voltage Wall Mount PIR
@ 10ft high
Long Range Occupancy Sensor ODWLR-IDW
(30.48m, @
with Power Base Combo
3.04m high)
Protective Cage for
OSWCG-P0W — — —
Wall Mount Sensors
Leviton sensors meet the following applicable agency listings: UL, cULus, ETL, CSA and NOM.
Sensing Control | Line Voltage

See product data sheets for specific listings.


Field of View (in feet)
TOP VIEW
58
Field of View (in feet)

TOP VIEW
58
31

16
11.5 29

11.5 0
16

31
29

58 Minor Motion, IR
58
Major Motion, IR
8 SIDE VIEW SIDE VIEW Minor Motion, IR
Minor Motion, Ultrasonic 8
Major Motion, IR
Major Motion, Ultrasonic

0 Minor Motion, Ultrasonic


0
0 3 8 15 31 68
0 3 8 15 31 68 Major Motion, Ultrasonic
23 32

ODW12-M0W Field of View (in feet) ODWWV Field of View (in feet)

Field of View (in feet) Field of View (in feet)

TOP VIEW TOP VIEW


3.5 16.6
0
3.5
0

30 SIDE VIEW

16.6

10 SIDE VIEW

0
0 3 13 25 52 0 14 42 71 100

ODWHB Field of View (in feet) ODWLR Field of View (in feet)

8
PROVOLT™ SELF-CONTAINED CEILING MOUNT OCCUPANCY SENSORS—
DAYLIGHT HARVESTING CAPABLE
Provolt Self-Contained Passive Infrared Ceiling Mount Occupancy Sensors — Daylight Harvesting Capable
Description Cat. No. Coverage Color Input Voltage, Rating
120V, 50/60Hz
8A, Electronic Ballast,
Provolt Line Voltage Ceiling Mount PIR Occupancy ODC04-IDW 800W/VA, Tungsten Ballast,
450SF
Sensor w/Integrated Photocell, High-Density Lens O2C04-IDW 1/4 HP Motor
(41.80SM)
installed, Mid-Range Lens included (Dual Relay)
230V, 50Hz
6A/6AX, Electronic Ballast,
W
Magnetic Ballast, 1200W/VA,
1/3 HP Motor
Provolt Line Voltage Ceiling Mount PIR Occupancy ODC15-IDW
1500SF
Sensor w/Integrated Photocell, Extended Range O2C15-IDW 277V, 50/60Hz
(139.35SM)
Lens installed, Mid-Range Lens included (Dual Relay) 6A, Electronic Ballast,
1200VA,
1/3 HP Motor
Leviton sensors meet the following applicable agency listings: UL, cULus, ETL, CSA and NOM.
See product data sheets for specific listings.

Sensing Control | Line Voltage


TOP VIEW TOP VIEW TOP VIEW
12 20 15

10

10
5
5

0 0
0

5
5
10
10

15
12 SIDE VIEW
20
SIDE VIEW Minor Motion, Infrared 20
Major Motion, Infrared
12
SIDE VIEW
12

0
12 9 7 5 3 0 3 5 7 9 12 20 15 11 9 5.6 3 0 3 5.6 9 11 15 20 30 25 20 15 10 5 0 5 10 15 20 25 30

ODC04-IDW, O2C04-IDW ODC15-IDW, O3C15-IDW, Mid-Range Lens (mounting up to 20 feet)


(High Density: Blue Lens) O2C15-IDW, O4C15-IDW (Included with all PIR and Multi-Tech Models)
(Extended Range: Black Lens)

www.leviton.com/sensors 9
PROVOLT™ SELF-CONTAINED CEILING MOUNT OCCUPANCY SENSORS—
DAYLIGHT HARVESTING CAPABLE
Provolt Self-Contained Ultrasonic Ceiling Mount Occupancy Sensors — Daylight Harvesting Capable
Description Cat. No. Coverage Color Input Voltage, Rating

Provolt Line Voltage Ceiling Mount U/S Occupancy ODC05-UDW 277V, 50/60Hz
500SF 5A, Electronic Ballast,
Sensor w/Integrated Photocell, Extended Range O2C05-UDW
(46.45SM) 800W/VA, Tungsten Ballast,
Lens installed (Dual Relay)
1/3 HP Motor

Provolt Line Voltage Ceiling Mount U/S Occupancy ODC10-UDW 230V, 50Hz
1000SF 6A/6AX, Electronic Ballast,
Sensor w/Integrated Photocell, Extended Range O2C10-UDW W
(92.90SM) Magnetic Ballast, 1200W/VA,
Lens installed (Dual Relay)
1/3 HP Motor

Provolt Line Voltage Ceiling Mount U/S Occupancy ODC20-UDW 277V, 50/60Hz
2000SF 5A, Electronic Ballast,
Sensor w/Integrated Photocell, Extended Range O2C20-UDW
(185.81SM) 1200VA,
Lens installed (Dual Relay)
1/3 HP Motor
Sensing Control | Line Voltage

TOP VIEW

11.5
TOP VIEW
8.5
11.5
8.5

0
0

8.5
8.5
11.5
11.5

Minor Motion, Ultrasonic


Minor Motion, Ultrasonic
Major Motion, Ultrasonic
Major Motion, Ultrasonic

5 0 10 20 0
17 23 23 17 17 23

ODC05-UDW, O2C05-UDW ODC10-UDW, O2C10-UDW

TOP VIEW

16

11.5

11.5

16

Minor Motion, Ultrasonic


Major Motion, Ultrasonic

0
32 22.5 22.5 32

ODC20-UDW, O2C20-UDW

10
Provolt Self-Contained Multi-Technology Ceiling Mount Occupancy Sensors — Daylight Harvesting Capable
Description Cat. No. Coverage Color Input Voltage, Rating
120V, 50/60Hz
Provolt Line Voltage Ceiling Mount Multi-Technology ODC05-MDW
500SF 8A, Electronic Ballast,
Occupancy Sensor w/Integrated Photocell, Extended O2C05-MDW
(46.45SM) 800W/VA, Tungsten Ballast,
Range Lens installed (Dual Relay)
1/4 HP Motor

Provolt Line Voltage Ceiling Mount Multi-Technology ODC10-MDW 230V, 50Hz


1000SF
Occupancy Sensor w/Integrated Photocell, Extended O2C10-MDW 6A/6AX, Electronic Ballast,
(92.90SM) W
Range Lens installed, Mid-Range Lens included (Dual Relay) Magnetic Ballast, 1200W/VA,
1/3 HP Motor

Provolt Line Voltage Ceiling Mount Multi-Technology ODC20-MDW 277V, 50/60Hz


2000SF 5A, Electronic Ballast,
Occupancy Sensor w/Integrated Photocell, Extended O2C20-MDW
(185.81SM) 1200VA,
Range Lens installed, Mid-Range Lens included (Dual Relay)
1/3 HP Motor

Leviton sensors meet the following applicable agency listings: UL, cULus, ETL, CSA and NOM. See product data sheets for specific listings.

Sensing Control | Line Voltage


TOP VIEW
TOP VIEW
20 20

11.5
11.5
8.5
8.5

0
0

8.5

8.5 11.5
11.5

20 Major Motion, IR
Major Motion, IR Minor Motion, Ultrasonic
20
SIDE VIEW
SIDE VIEW
8 Minor Motion, Ultrasonic Major Motion, Ultrasonic
8
Major Motion, Ultrasonic

0 0
0 3 5.6 9 11 15 20 20 15 11 9 5.6 3 0 3 5.6 9 11 15 20
17 23 17 17 23
23

ODC05-MDW, O2C05-MDW ODC10-MDW, O3C10-MDW, O2C10-MDW,O4C10-MDW


(High Density: Blue Lens) (Extended Range: Black Lens)

TOP VIEW
15

TOP VIEW
20
10

16
5
11.5

0
5

10
11.5

8.5 15
SIDE VIEW
20
Major Motion, IR 20
Minor Motion, Ultrasonic
SIDE VIEW Major Motion, Ultrasonic
8

0
20 15 11 9 5.5 3 0 3 5.5 9 11 15 20 30 25 20 15 10 5 0 5 10 15 20 25 30
32 22.5 22.5 32

ODC20-MDW, O3C20-MDW, Mid-Range Lens (mounting up to 20 feet)


O2C20-MDW, O4C20-MDW (Included with all PIR and Multi-Tech Models)

www.leviton.com/sensors 11
PROVOLT SELF-CONTAINED CEILING MOUNT VACANCY SENSORS
Provolt Self-Contained Ceiling Mount Vacancy Sensors
Description Cat. No. Coverage Color Input Voltage, Rating
120V, 50/60Hz
Provolt Line Voltage Ceiling Mount 03C15-IDW 04C15-IDW 1500SF 8A, Electronic Ballast,
PIR Vacancy Sensor (Dual Relay) (139.35SM) 800W/VA, Tungsten Ballast,
1/4 HP Motor

230V, 50Hz
Provolt Line Voltage Ceiling Mount 03C10-MDW 04C10-MDW 1000SF 6A/6AX, Electronic Ballast,
PIR Vacancy Sensor (Dual Relay) (92.90SM) W
Magnetic Ballast, 1200W/VA,
1/3 HP Motor

277V, 50/60Hz
Provolt Line Voltage Ceiling Mount 03C20-MDW 04C20-MDW 2000SF 5A, Electronic Ballast,
PIR Vacancy Sensor (Dual Relay) (185.81SM) 1200VA,
1/3 HP Motor
Leviton sensors meet the following applicable agency listings: UL, cULus, ETL, CSA and NOM.
See product data sheets for specific listings.
Sensing Control | Line Voltage

ODC20-MDW

OXCXX-IDW

Flat Light Pipe

Angled Light Pipe

ODC20-MDW (top view)

12
SELF-CONTAINED FIXTURE MOUNT HIGH-BAY PIR AND INTEGRAL LUMINAIRE
OCCUPANCY SENSORS
Self-Contained PIR High Bay Occupancy Sensors*
Coverage
360° high-bay lens — 2:1 spacing to mounting height under 20 ft. and 1.5:1 spacing to mounting height @ 40 ft.
360° low-bay lens — 2:1 spacing to mounting height @ 8 ft. to 20 ft.
Description Cat. No. Models Rating
OSFHU-ITW 120-230-277-347V
Fluorescent: 800VA @ 120V,
Fixture Mount High-Bay PIR Occupancy OSFHU-CTW 120-230-277-347V, Cold Storage Fluorescent: 1200VA @ 277V,
Sensor with Two Interchangeable Lenses, Fluorescent: 1500VA @ 347V,
for 360º High-Bay, 360º Low Bay OSFHU-I4W 240/480V 50/60Hz (OSFHU-x4W models only)
Motor: 1/4 HP @ 120V
OSFHU-C4W 240/480V, Cold Storage

Fixture Mount High-Bay PIR Occupancy Input: 20mA


Sensor with Two Interchangeable Lenses OSFHP-ILW 24V Output: 120mA
and Light Sensor, Low Voltage HVAC: 1A, 30V DC

OSFHP-ITW 120-230-277-347V

Fixture Mount High-Bay PIR Occupancy OSFHP-I4W 240/480V Fluorescent: 800VA @ 120V,
Fluorescent: 1000VA @ 230V AC,

Sensing Control | Line Voltage


Sensor with Two Interchangeable Lenses
OSFHD-ITW 120-230-277-347V, Dual Relay
and Light Sensor Fluorescent: 1200VA @ 277V AC,
120-230-277-347V, Fluorescent: 1500VA @ 347V AC,
OSFHD-CTW
Dual Relay, Cold Storage Fluorescent: 2000VA @ 480V AC,
50/60Hz.
Fixture Mount High-Bay PIR Occupancy OSFHD-IAW 120-230-277V Motor: 1/4 HP @ 120V
Sensor with Two Interchangeable Lenses
and Alternating Relay OSFHD-CAW Cold Storage

Fluorescent: 800VA @ 120V,


Surface Mount High-Bay PIR Occupancy Fluorescent: 1200VA @ 277V AC,
OSFHS-ITW 120-230-277-347V
Sensor Fluorescent: 1500VA @ 347V AC,
Motor: 1/4 HP @ 120V
Coverage
360º — 1:1 spacing to mounting height up to 8 ft.

Description Cat. No. Models Rating


OSFHU-I0W 120-230-277V (Integrated Unit) Incandescent: 598W @ 120V.
OSF10-IUW 120-230-277V, Sensor Head Fluorescent: 800VA @ 120V,
Integral Luminaire Fixture Mount
Fluorescent: 1000VA @ 230V AC,
PIR Occupancy Sensor OSF10-PPW 120-230-277V, Power Pack
Fluorescent: 1200VA @ 277V AC,
OSFCA-36W 36” Connection Cable 50/60Hz
*Consult with factory for 208, 220, 230, and 240V load ratings.
Leviton sensors meet the following applicable agency listings: UL, cULus, ETL, CSA and NOM. See product data sheets for specific listings.

OSFHU-ITW OSFHP OSFHD OSFHS OSF10-xxx

www.leviton.com/sensors 13
30 ft

20 ft
High Bay Aisl e
360˚ 10 ft Top View
Top View
0 Black Lens
SELF-CONTAINED FIXTURE MOUNT HIGH-BAY PIR White
ANDLens
INTEGRAL
10 ft
LUMINAIRE OCCUPANCY SENSORS
20 ft

Self-Contained Infrared High Bay Occupancy Sensor Accessories 30 ft


Description Cat. No. 0
Side View Side View
High-Bay Lens for High-Bay Sensors OSFLN-00W
Low-Bay Lens for High-Bay Sensors OSFLN-00B 20 ft
30 ft
Aisle Lens for High-Bay Sensors OSFLN-00E
40 ft
Offset Adaptor Accessory for Fixture-Mount Occupancy Sensor OSFOA-00W 30 ft 20 ft 10 ft OSFOA
0 10 ft 20 ft 30 ft

Offset Adaptor Accessory for High-Bay Occupancy Sensor OSFLO-00W


Protective Cage for High-Bay Mount Sensors OSFCG-00W

30 ft 30
30ftft

20 ft 20
20ftft
High Bay LowAisl
Baye
360˚ 10 ft 360°View
Top 10
10ftft
Top View Top View
0 00
Black Lens
White Lens 10 ft
Blue Lens 10
10ftft
Sensing Control | Line Voltage

20 ft 20
20ftft

30 ft 30
30ftft

0 00
Side View Side
SideView
View
8 ft S
H
S
H
E E
20 ft 20 ft L L
V V
E E
30 ft 20
30ftft S S

40 ft 25
40ftft
30 ft 20 ft 10 ft 0 10 ft 20 ft 30 ft 30ftft 20
30 20ftft 10
10ftft 00 10
10ftft20
20ftft30
30ftft

OSFHU/OSFHP/OSFHD Field of View (in feet)

30 ft
10' 8' 6' 4' 2' 0' 2' 4' 6' 8' 10'

20 ft
Low Bay 8'
360° 10 ft
Top View 6'
0
4'
Blue Lens 10 ft 2'

20 ft 0'

30 ft 2'

0 4'
Side View
8 ft 6'

8'
20 ft
10'
25 ft
30 ft 20 ft 10 ft 0 10 ft 20 ft 30 ft 0'

2'

4'

6'

8'

OSF10 Field of View (in feet)

14
CEILING MOUNT MULTI-TECHNOLOGY OCCUPANCY SENSORS
Ceiling Mount Multi-Technology Occupancy Sensors and Accessories For Use with
Leviton Power Pack or Power Base Adaptor
Operating
Description Cat. No. Rating Color
Frequency
Ceiling Mount Multi-Technology 180°, 500SF
OSC05-M0W
Occupancy Sensor (46.45SM)
40kHz
Ceiling Mount Multi-Technology 360°, 1000SF OSC05-M0W
OSC10-M0W Off-White
Occupancy Sensor (92.90SM)
Ceiling Mount Multi-Technology 360°, 2000SF
OSC20-M0W 32kHz
Occupancy Sensor (185.81SM)
Ceiling Mount Multi-Technology 180°, 500SF
OSC05-RMW
Occupancy Sensor with Isolated Relay (464.52SM)
40kHz
Ceiling Mount Multi-Technology 360°, 1000SF White
OSC10-RMW
Occupancy Sensor with Isolated Relay (92.90SM)
Ceiling Mount Multi-Technology 360°, 2000SF
OSC20-RMW 32kHz
Occupancy Sensor with Isolated Relay (185.81SM)
OSC10/OSC20-MDW
Power Base Adaptor OPB15-0DW
Off-White
Cosmetic Adaptor OPBCA-00W — —

Sensing Control | Low Voltage


Protective Cage for Ceiling-Mount Sensors ODCCG-000 —
Note: Use low-voltage wiring to connect sensors to OPP20 or OSPxx Power Pack or OPB15 Power Base Adaptor
Leviton sensors meet the following applicable agency listings: UL, cULus, ETL, CSA and NOM. See product data sheets for specific listings.

TOP VIEW
8 20 TOP VIEW TOP VIEW
20
11.5 16
11.5
8.5 11.5
8.5

0 0 0

8.5 8.5
11.5 11.5 11.5
16
20 20
20
SIDE VIEW SIDE VIEW SIDE VIEW
8 8
8

0 0
0 3 5.6 9 11 15 20 20 15 11 9 5.6 3 0 3 5.6 9 11 15 20 20 15 11 9 5.5 3 0 3 5.5 9 11 15 20
17 23 23 17 17 23 32 22.5 22.5 32

OSC05-M0W Field of View (in feet) OSC10-M0W Field of View (in feet) OSC20-M0W Field of View (in feet)
Minor Motion, IR
Major Motion, IR

Minor Motion, Ultrasonic


Major Motion, Ultrasonic

www.leviton.com/sensors 15
CEILING MOUNT PIR OCCUPANCY SENSORS
Infrared Ceiling Mount Occupancy Sensors and Accessories For Use with Leviton Power
Pack or Power Base Adaptor
Description Cat. No. Coverage Color
360°, 450SF
Ceiling Mount PIR Occupancy Sensor OSC04-I0W
(41.80sm)
Off-White
360°, 1500SF
Ceiling Mount PIR Occupancy Sensor OSC15-I0W
(139.35sm) OSC04-I0W
Ceiling Mount PIR 360°, 450SF
OSC04-RIW
Occupancy Sensor with Isolated Relay (41.80sm)
White
Ceiling Mount PIR 360°, 1500SF
OSC15-RIW
Occupancy Sensor with Isolated Relay (139.35sm)
Power Base Adaptor OPB15-0DW
Off-White
Cosmetic Adaptor OPBCA-00W —
Protective Cage for Ceiling Mount Sensors ODCCG-000 White
Note: Use low-voltage wiring to connect sensors to OSPXX Power Pack OPP20 or OSPxx Power Pack or OPB15 Power Base Adaptor.
Leviton sensors meet the following applicable agency listings: UL, cULus, ETL, CSA and NOM.
See product data sheets for specific listings.
Sensing Control | Low Voltage

TOP VIEW TOP VIEW


12 20

5 10

0 0

5
10

12 20
SIDE VIEW
8
SIDE VIEW
8

0
12 9 7 5 3 0 3 5 7 9 12 20 15 11 9 5.6 3 0 3 5.6 9 11 15 20

OSC04-I0W Field of View (in feet) OSC15-I0W Field of View (in feet)

Minor Motion, IR
Major Motion, IR

Minor Motion, Ultrasonic


Major Motion, Ultrasonic

16
CEILING MOUNT ULTRASONIC OCCUPANCY SENSORS
Ceiling Mount Ultrasonic Occupancy Sensors and Accessories For Use with Leviton Power
Pack or Power Base Adaptor
Operating
Description Cat. No. Coverage Color
Frequency
Ceiling Mount Ultrasonic 180°, 500SF
OSC05-U0W
Occupancy Sensor (46.45SM)
40kHz
Ceiling Mount Ultrasonic 360º, 1000SF OSC05-U0W
OSC10-U0W Off-White
Occupancy Sensor (92.90SM)
Ceiling Mount Ultrasonic 360°, 2000SF
OSC20-U0W 32kHz
Occupancy Sensor (185.81SM)
Ceiling Mount Ultrasonic 180º, 500SF
OSC05-RUW
Occupancy Sensor with Isolated Relay (46.45SM)
40kHz
Ceiling Mount Ultrasonic 360º, 1000SF
OSC10-RUW White
Occupancy Sensor with Isolated Relay (92.90SM)
Ceiling Mount Ultrasonic 360º, 2000SF
OSC20-RUW 32kHz
Occupancy Sensor with Isolated Relay (185.81SM)
Power Base Adaptor OPB15-0DW
Off-White
Cosmetic Adaptor OPBCA-00W

Sensing Control | Low Voltage


— —
Protective Cage for
ODCCG-000 White
Ceiling-Mount Sensors
Note: Use low-voltage wiring to connect sensors to OPP20 or OSPxx Power Pack or OPB15 Power Base Adaptor
Leviton sensors meet the following applicable agency listings: UL, cULus, ETL, CSA and NOM. See product data sheets for specific listings.

11.5 11.5 16
8.5 8.5 11.5

0
0

81.5 11.5
8.5
11.5 16
11.5

5 0 10 20 32 22.5 0 22.5 32
17 23 23 17 0 17 23

OSC05-U0W Field of View (in feet) OSC10-U0W Field


Minor of View
Motion, IR (in feet) OSC20-U0W Field of View (in feet)

Major Motion, IR

Minor Motion, Ultrasonic


Major Motion, Ultrasonic

www.leviton.com/sensors 17
WALL MOUNT PIR OCCUPANCY SENSORS
Infrared Indoor Wall-Mount Occupancy Sensors and Accessories For Use with Leviton
Power Pack or Power Base Adaptor
Description Cat. No. Coverage Color
Wide-View Wall Mount PIR 115°, 2500SF
OSWWW-I0W
Occupancy Sensor (232.26SM)
High-Bay Wall Mount PIR 55 ft. x 7 ft. wide @ 10 ft. high
OSWHB-I0W Off-White
Occupancy Sensor (16.76m x 4.26m wide @ 3.04m high)
Long-Range Wall Mount PIR 100 ft. x 14 ft. @ 10 ft. high
OSWLR-I0W
Occupancy Sensor (30.48m x 4.26m @ 3.04m high) OSWHB-I0W

Wide-View Wall Mount PIR


115°, 2500SF
Occupancy Sensor with OSWWV-RIW
(232.26SM)
Isolated Relay
High-Bay Wall Mount PIR
55 ft. x 7 ft. wide @ 30 ft. high
Occupancy Sensor with OSWHB-RIW White
(16.76m x 4.26m wide @ 9.14m high)
Isolated Relay
Long-Range Wall Mount PIR
100 ft., 110º @ 10 ft. high
Occupancy Sensor with OSWLR-RIW
(30.48m, @ 3.04m high)
Isolated Relay
Wall-Mount Multi-Technology
OSW12-M0W Off-White
Sensing Control | Low Voltage

Occupancy Sensor
115°, 1200SF
Wall-Mount Multi-Technology (111.48SM)
Occupancy Sensor with OSW12-RMW White OSW12-M0W
Isolated Relay Wall Mount
Power Base Adaptor OPB15-0DW
Off-White
Cosmetic Adaptor OPBCA-00W

Protective Cage for
OSWCG-P0W White
Ceiling-Mount Sensors

Note: Use low-voltage wiring to connect sensors to OPP20 or OSPxx Power Pack or OPB15 Power Base Adaptor
Leviton sensorsField
meetofthe following applicable agency listings: UL, cULus, ETL, CSA and NOM. See product data sheets for specific listings
View (in feet)

TOP VIEW
3.5
0 Minor Motion, IR
3.5
Major Motion, IR

30 SIDE VIEW Minor Motion, IR Minor Motion, Ultrasonic


Major Motion, IR Major Motion, Ultrasonic

Minor Motion, Ultrasonic


Field of View (in feet) Field of View (in feet)
Major Motion, Ultrasonic
TOP VIEW
TOP VIEW
58 58

0 3 13 25 52
29 31
OSWHB
Field of View (in feet) 16
Field of View (in feet) 11.5

0 0
TOP VIEW
16.6
11.5
16

0
29
31

16.6
58
58
10 SIDE VIEW

SIDE VIEW 8 SIDE VIEW


8

0 0 0
0 14 42 71 100 0 3 8 15 31 68 0 3 8 15 31 68
23 32

OSWLR OSWWV OSW12-M0W


Field of View (in feet) Field of View (in feet) Field of View (in feet)

18
POWER PACKS AND POWER BASE ADAPTOR
COMMERCIAL GRADE OCCUPANCY SENSOR POWER PACKS
Occupancy Sensor Power Packs
Control Pow Supply
Description Cat. No. Power Input* Relay Rating
Input Output
Super Duty Power Pack with 20A, 2400W @ 120V – Resistive
Auto-ON, Manual-ON, and 20A, 2400W @ 120V – General Purpose
OPP20-0D2
Local Switch Inputs, 20A, 2400W @ 120V – Incandescent
CA Title 24 20A, 2400W @ 120V – Fluorescent
225mA,
Super Duty Power Pack with 20A, 5540W @ 277V – Resistive 2mA,
OPP20-RD3 24VDC,
Auto-ON and Photocell Input 20A, 5540W @ 277V – General Purpose 24VDC
5.4W
Super Duty Power Pack with 20A, 5540VA @ 277V – Fluorescent
120-230-277VAC,
Auto-ON, Manual-ON, Switch, 16A, 4430VA @ 277V – Electronic Ballasts
OPP20-RD4 ** 50/60 Hz
and Photocell Input, 1/2 HP @ 120V – Motor Load
CA Title 24 2 HP @ 240/277V – Motor Load
20A Incandescent @ 120V,
Power Pack with HVAC Relay 20A Fluorescent @ 120-230- 225mA,
withAuto-ON and Manual-ON OSP20-RDH 277/347VAC; 1/2HP @ 120V, 24VDC
Inputs for Occupancy Sensors 2HP @ 240-277V;
HVAC: 0.5A @ 120VAC, 1A @ 30VDC 5mA,

Sensing Control | Power Packs


15A fluorescent @ 347V; 24VDC 120mA,
Power Pack with
OSP15-R30 347VAC, 60Hz 1HP @ 120V, 2HP @ 240V; 24VDC
HVAC Relay
HVAC: 0.5A @ 120VAC, 1A @ 30VDC
Add-A-Relay Unit with 15A incandescent @ 120V,
OSA20-R00 — —
HVAC Relay HVAC: 0.5A @ 125VAC, 1A @ 30VDC
*Consult with factory for 208, 220, and 240V models
Leviton power packs meet the following applicable agency listings: UL, cULus, ETL, CSA and NOM. See product data sheets for specific listings.
**OPP20-RD4 is for general purpose plug load control - 20A, 2400W @ 120V - complies with ASHRAE 90.1 and CA Title 24 Plug Load Control Requirements

OPP20 OSP20

www.leviton.com/sensors 19
POWER PACK CAPACITY FORMULA
Leviton power packs can be used to provide power to one or more sensors. Since current consumptions of sensors may vary,
the best way to ensure you order the correct number of power packs and Add-A-Relays is by using this formula:

Sensor Current Consumption


OSC04-I, OSC15-I, OSWHB-I, Number of Number of
10-15mA Number of
OSWLR-I, OSWWV-I Model A sensors Model B sensors
Add-A-Relays
OSC05-M, OSC05-U, OSW12-M 25mA X + X + < 225mA
X
OSC10-M, OSC10-U 35mA Sensor A current Sensor B current
50mA
consumption rating consumption rating
OSC20-M, OSC20-U 50mA
OSA20-R00 Add-A-Relay 50mA

SELF-CONTAINED POWER BASE ADAPTOR


Converts any Leviton low voltage ceiling or wall-mount occupancy sensor to a self-contained, line voltage unit with 15A,
120/277V load capacity.

Power Base Adaptor


Description Cat. No. Power Input/Output Rating Color
Sensing Control | Power Packs

Power Input: 120-230-277VAC, 50/60Hz


Converts select Leviton low-voltage Control Input: 24VDC, 5mA
ceiling or wall mount occupancy Power Output: 120VAC @15A incandescent;
OPB15-0DW 15A
sensor models to a self-contained 277VAC @ 15A fluorescent; Off-White
line voltage unit Motor: 120VAC 3/4HP, 277VAC 2HP
Control Output: 24VDC, 40mA
Cosmetic Adaptor OPBCA-00W — —
Agency Listings & Code Compliance: NOM Certified.
*Available in Off-White only.
Consult with factory for 208, 220, 230 and 240V load ratings.
Note: Converts OSCxx-I, OSCxx-M and OSCxx-U. Does not convert OSCxx-R

OPB15-0DW (Occupancy Sensor not included)

20
WIRELESS SENSORS
Commercial Grade

Specifications WSC12-M9N WSWDR-H9W


Features
Technology Passive Infrared
Mounting Ceiling Wall
Long Range: 1600 SF Minor, 3300 SF Major
Coverage (SF) 1200
Wide Angle: 2000 SF Minor, 3960 SF Major
Pattern 360° 180°
Mounting Height Up to 10’ 6-8’
Adjustment Manual
Time Delay 2m-30m
Voltage Self-Powered, Energy Harvesting
Wattage/VA Self-Powered, Energy Harvesting
Occupancy or Vacancy Occupancy

Sensing Control | Self-Powered


Auto or Manual Both - auto or manual selected in load receiver during pairing
Ambient Light Override —
Energy Harvesting, Self-Powered,
Other
Wireless Up to 100’
Mechanical
Switching Technology Relay - when paired with load receiver
Neutral Required No
Ground Required No
Power External Power Not Required
Consumption (mA) Self-Powered, Energy Harvesting
Photocell Not Applicable
HVAC Relay Not Applicable
Environmental
Operating 0 to 50°C/ 0 to 50°C/
Temperature/ 20 to 95% 20 to 95%
Humidity
Certifications
CA Title 24
Yes
Compliant

www.leviton.com/sensors 21
WALL SWITCH
Residential Grade

Specifications IPS02-1L IPV02-1L IPS05-1L IPV05-1L


Features
Technology Passive Infrared
Mounting Wall
Coverage (SF) 900
Pattern 180°
Mounting Height 4’
Adjustment Manual
Time Delay 30s-30m
Voltage 120VAC, 60 Hz
Wattage/VA 200VA 600W
Sensing Control | Wall Switch Residential

Occupancy or Vacancy Occupancy Vacancy Occupancy Vacancy


Auto or Manual Auto Manual Auto Manual
Ambient Light Override Yes No Yes No
Other Single Pole
Mechanical
Switching Technology Relay
Neutral Required No
Ground Required Yes
Power Pack External Power Pack Not Required
Consumption No
Photocell Internal
HVAC Relay Not Applicable
0 to 40°C/
Environmental Operating 20 to 90%
Temperature/Humidity Non-Condensing
Indoor Use Only
Certifications
CA Title 20
Yes
Compliant
CA Title 24
No Yes No Yes
Compliant

22
WALL SWITCH
Residential
Grade

Specifications IPS06-1L IPSD6-1L IPVD6-1L IPS15-1L IPV15-1L IPHS5-W


Features
Technology Passive Infrared Digital Sensor
Mounting Wall
Coverage (SF) 900 —
Pattern 180° —
Mounting Height 4’
Adjustment Manual
Time Delay 30s-30m 10m-45m
Voltage 120VAC, 60 Hz
Wattage/VA — 1800VA 600W

Sensing Control | Wall Switch Residential


Occupancy or
Occupancy Vacancy Occupancy Vacancy Occupancy
Vacancy
Auto or Manual Auto Manual Auto Manual Auto
Ambient Light
Yes No Yes No
Override
Single Pole/3-Way
Other Single Pole/3-Way Single Pole
with IPVOR Remote Sensor
Mechanical
Switching
Triac Relay
Technology
Neutral Required No Yes
Ground Required No
Power Pack Not
Power Pack External Power Pack Not Required
Required
Consumption No
Photocell Internal None
HVAC Relay Not Applicable
Environmental 0 to 40°C/
Operating 20 to 90%
Temperature/ Non-Condensing
Humidity Indoor Use Only
Certifications
Listing UL
CA Title 20
Yes No
Compliant
CA Title 24
No Yes No Yes
Compliant

www.leviton.com/sensors 23
WALL SWITCH
Commercial
Grade

Specifications ODS06-ID ODS10-ID ODS10-I3 ODS10-IQ MDS10-ID


Features
Technology Passive Infrared
Mounting Wall
Coverage (SF) 2100
Pattern 60°-180°
Mounting Height 4’
Adjustment Manual
Time Delay 30s-30m
Voltage 120-230-277 VAC 347 VAC 120-230-277 VAC
Wattage/VA 800/1500 3470 1800/4000
Sensing Control | Wall Switch Commercial

Occupancy or Vacancy Occupancy Vacancy Occupancy


Auto or Manual Both Auto Both
Ambient Light Override Yes
Single Pole, Multi-Location; Select Models Feature Auto-ON/Auto-OFF Only (ODS10-IQ), Self-Adaptive
Other
(MDS10, ODS15, MDS15, ODS0D), or Lev-Lok (MDS10, MDS15) Technology
Mechanical
Switching
Relay
Technology
Neutral Required No
Ground Required Yes
Power Pack External Power Pack Not Required

Consumption 100-250mW

Photocell Internal
HVAC Relay Not Applicable
0 to 40°C/ 0 to 50°C/
Environmental Operating 0 to 95% 20 to 90%
Temperature/Humidity Non-Condensing Non-Condensing
Indoor Use Only Indoor Use Only
Photocell Internal
Certifications
Listing UL cUL UL

CA Title 20
Yes No Yes
Compliant
CA Title 24
Yes No Yes
Compliant

24
WALL SWITCH
Commercial
Grade

Specifications ODS15-ID ODS15-TD MDS15-ID ODS0D-ID OSSNL-ID OSS10-IN


Features
Technology Passive Infrared
Mounting Wall
Coverage (SF) 2100
Pattern 60°-180°
Mounting Height 4’
Adjustment Self-Adjusting Manual
Time Delay 30s-20m or 5m-30m 30s-2h 30s-30m
Voltage 120-230-277 VAC

Sensing Control | Wall Switch Commercial


Wattage/VA 1800/400 800/2700 1200/2700
Occupancy or Vacancy Vacancy Occupancy Vacancy
Auto or Manual Manual Both Manual
Ambient Light Override Yes No
Single Pole, Multi-Location;
Select Models Feature Auto-ON/
Single Pole,
Auto-OFF Only (ODS10-IQ), Dual Relay, Single Pole, Multi-Location,
Other Multi-Location,
Self-Adaptive (MDS10, ODS15, Self-Adaptive LED Night Light
Lev-Lok
MDS15, ODS0D), or Lev-Lok
(MDS10, MDS15) Technology
Mechanical
Switching
Relay
Technology
Neutral Required No
Ground Required Yes
Power Pack External Power Pack Not Required
Consumption 120-280mW 110-270mW 190-410mW
Photocell Internal None
HVAC Relay Not Applicable
Environmental Operat- 0 to 40°C/ 0 to 50°C/
ing 0 to 95% 20 to 90%
Temperature/ Non-Condensing Non-Condensing
Humidity Indoor Use Only Indoor Use Only
Photocell Internal None

Certifications
Listing UL
CA Title 20
Yes
Compliant
CA Title 24
Yes
Compliant

www.leviton.com/sensors 25
WALL SWITCH
Commercial
Grade

Specifications OSSMT-MD OSSMT-GD OSSMT-M3 OSSMT-MQ OSSMT-GQ OSSMT-TM


Features
Technology Multi-Technology
Mounting Wall
Coverage (SF) 2400
Pattern 60°-180°
Mounting Height 4’
Adjustment Self-Adjusting
Time Delay 30s-30m
Voltage 120-230-277 VAC 347 VAC 120-230-277 VAC
Wattage/VA 800/2700 1200/2700
Sensing Control | Wall Switch Commercial

Occupancy or
Occupancy Vacancy
Vacancy
Auto or Manual Both Auto Manual
Ambient Light
Yes
Override
Single Pole, Multi-Location; Select Models Feature No Neutral (OSSMT-GT, OSSMT-GQ, MSSMT-GD,
Other
OSSMD-GD), Auto-ON/Auto-OFF Only (OSSMT-MQ, OSSMT-GQ), or Lev-Lok (MSSMT) Technology
Mechanical
Switching
Relay
Technology
Neutral Required Yes No Yes No Yes
Ground Required Yes
Power Pack External Power Pack Not Required
Consumption 190-480mW 190-480mW 350-500mW 190-480mW 70-340mW 190-480mW
Photocell Internal
HVAC Relay Not Applicable
Environmental 0 to 40°C/
Operating 20 to 90%
Temperature/ Non-Condensing
Humidity Indoor Use Only
Photocell Internal
Certifications
Listing UL ETL CETL UL ETL UL
CA Title 20
Yes
Compliant
CA Title 24
Yes
Compliant

26
WALL SWITCH
Commercial
Grade

Specifications OSSMT-GT MSSMT-GD OSSMD-MD OSSMD-GD


Features
Technology Multi-Technology
Mounting Wall
Coverage (SF) 2400
Pattern 60°-180°
Mounting Height 4’
Adjustment Self-Adjusting
Time Delay 30s-30m
Voltage 120-230-277 VAC
Primary Relay: 1200/2700,

Sensing Control | Wall Switch Commercial


Wattage/VA 1200/2700
Secondary Relay: 800/1200
Occupancy or
Vacancy Occupancy
Vacancy
Auto or Manual Manual Both
Ambient Light
Yes
Override
Single Pole, Multi-Location, Single Pole, Multi-Location, Dual Relay,
Other
No Neutral Required, Lev-Lok (MSSMT) No Neutral Required (OSSMD-GD)
Mechanical
Switching
Relay
Technology
Neutral Required No Yes No
Ground Required Yes
Power Pack External Power Pack Not Required
Consumption 70-340mW 210-410mW 140-360mW
Photocell Internal
HVAC Relay Not Applicable
Environmental 0 to 40°C/
Operating 20 to 90%
Temperature/ Non-Condensing
Humidity Indoor Use Only
Photocell Internal
Certifications
Listing ETL
CA Title 20
Yes
Compliant
CA Title 24
Yes
Compliant

www.leviton.com/sensors 27
LINE VOLTAGE
Commercial
Grade
ODC04-IDW O2C04-IDW
Specifications O3C15-IDW O4C15-IDW
ODC15-IDW O2C15-IDW
Features
Technology Passive Infrared
Mounting Ceiling
Coverage (SF) 450; 1500 1500 450; 1500 1500
Pattern 360°
Mounting Height 8’-12’
Adjustment Self Adjusting
Time Delay 30s -30m
Voltage 120-220/277 VAC, 50/60Hz
Wattage/VA 800W/VA
Occupancy or
Occupancy Vacancy Occupancy Vacancy
Vacancy
Sensing Control | Line Voltage

Auto or Manual Both Manual Both Manual


Ambient Light
Yes
Override
Open/Closed Loop Dual Relay; Open/Closed
Dual Relay;
Daylight Harvesting Loop Daylight Harvesting
Momentary or
with Manual/AutoCal Momentary or Maintained with Manual/AutoCal
Maintained Manual
Other Configuration; Momentary Manual Switch Input; BMS/ Configuration; Momentary
Switch Input;
or Maintained Manual Switch Emergency Interface or Maintained Manual Switch
BMS/Emergency
Input; BMS/Emergency Input; BMS/Emergency
Interface
Interface Interface
Mechanical
Switching
Zero Cross
Technology
Neutral
Yes
Required
Ground
No
Required
Power Pack Not Required
Consumption 60-30ma
Photocell AutoCal No Internal No
HVAC Relay Not Applicable
Environmental 0 to 40°C/
Operating 0 to 90%
Temperature/ Non-Condensing
Humidity Indoor Use Only
Certifications
Listing UL
CA Title 20
Yes
Compliant
CA Title 24
Yes
Compliant

28
LINE VOLTAGE
Commercial
Grade
ODC05-UDW O2C05-UDW ODC05-MDW O2C05-MDW
O3C10-MDW O4C10-MDW
Specifications ODC10-UDW O2C10-UDW ODC10-MDW O2C10-MDW
O3C20-MDW O4C20-MDW
ODC20-UDW O2C20-UDW ODC20-MDW O2C20-MDW
Features
Technology Ultrasonic Multi-Technology Multi-Technology
Mounting Ceiling
Coverage (SF) 500; 1000; 2000 1000; 2000 500; 1000; 2000 1000; 2000
Pattern 360°
Mounting Height 8’-12’
Adjustment Self-Adjusting
Time Delay 30s-30m
Voltage 120-220/277 VAC, 50/60Hz
Wattage/VA 800W/VA
Occupancy or
Occupancy Vacancy Occupancy Vacancy
Vacancy

Sensing Control | Line Voltage


Auto or Manual Both Manual Both Manual
Ambient Light
Yes
Override
Dual Relay; Open/Closed Dual Relay;
Momentary
Loop Daylight Harvesting Momentary
Open/Closed Loop Daylight Harvesting or Maintained
with Manual/AutoCal or Maintained
with Manual/AutoCal Configuration; Manual Switch
Other Configuration; Momentary Manual Switch
Momentary or Maintained Manual Switch Input; Input; BMS/
or Maintained Manual Input; BMS/
BMS/Emergency Interface Emergency
Switch Input; Emergency
Interface
BMS/Emergency Interface Interface
Mechanical
Switching
Zero Cross
Technology
Neutral
Yes
Required
Ground
No
Required
Power Pack Not Required
Consumption 60-30mA
Photocell AutoCal No Internal No
HVAC Relay Not Applicable
Environmental 0 to 40°C/
Operating 0 to 90%
Temperature/ Non-Condensing
Humidity Indoor Use Only
Certifications
LIsting UL
CA Title 20
Yes
Compliant
CA Title 24
Yes
Compliant

www.leviton.com/sensors 29
LINE VOLTAGE
Commercial
Grade
ODC0S-I1W
Specifications ODC0S-I2W ODWWV-IDW ODWHB-IDW ODWLR-IDW ODW12-MDW
ODC0S-I7W
Features
Technology Passive Infrared Multi-Technology
Mounting Ceiling Wall, Corner or Ceiling
Coverage (SF) 530 2500 55x7 100 1200
110° @
Pattern 360° 8° 110°
10ft high
Mounting Height 8’-15’ 8’-12’ 10’-30’ 8’-10’
Adjustment Manual
Time Delay 20s-15m
Voltage 120-220/277 VAC; 60Hz; 50Hz; 60Hz
Wattage/VA 1000VA; 500VA; 2700VA
Occupancy or
Occupancy Vacancy Occupancy
Vacancy
Sensing Control | Line Voltage

Auto or Manual Auto Manual Both


Ambient Light
Yes
Override
Wide View, High Bay, Long Range, Multi-Use,
Self-
Other Includes Includes Includes Includes
Contained
Power Base Power Base Power Base Power Base
Mechanical
Switching
Relay Zero Cross Relay
Technology
Neutral
Yes
Required
Ground
No
Required
Power Pack Not Required
Consumption 4W 60-30ma 0.7W-2.34W
20-3000
Photocell Internal No
Lux Adjustable
HVAC Relay Not Applicable
Environmental 0 to 40°C/
Operating 0 to 95%
Temperature/ Non-Condensing,
Humidity Indoor Use Only
Certifications
Listing UL
CA Title 20
No Yes
Compliant
CA Title 24
Yes Yes
Compliant

30
LINE VOLTAGE
Commercial
Grade
OSF10-I0W
Specifications OSFHP OSFHD OSFHS
OSF10-IUW
Features
Technology Passive Infrared
Mounting Fixture
Coverage (SF) 400-1600 6x10
Pattern 360° & Aisle Ways 360°
Mounting Height Up to 40’ Up to 8’
Adjustment Manual
Time Delay 30s-30m
Voltage 120-230-277-347/480 VAC, 50/60Hz 120-230-277-347V 50/60 Hz 120-277 VAC, 50/60Hz
Wattage/VA 800W/VA
Occupancy or
Occupancy
Vacancy
Auto or Manual Auto
Ambient Light
No Yes No

Sensing Control | Line Voltage


Override
Includes 2 Lenses for High Bay & Low Bay; Select Models Feature Integrated
Other Light Sensor, Alternating Relay, Dual Relay, Cold Storage Technology and 38” Leads
Triple Mount Options
Mechanical
Switching
Zero Cross
Technology
Neutral
Yes
Required
Ground
No
Required
Power Pack Not Required
Consumption 60-30ma
20-3000 Lux
Photocell No No
Adjustable
HVAC Relay Not Applicable
Environmental -10 to 71°C/ 0 to 71°C/ 0 to 5°C/
Operating 20 to 90% 10 to 90% 20 to 95%
Temperature/ Non-Condensing Non-Condensing Non-Condensing
Humidity Indoor Use Only Indoor Use Only Indoor Use Only
Certifications
Listing UL
CA Title 20
Yes
Compliant
CA Title 24
Yes
Compliant

www.leviton.com/sensors 31
LOW VOLTAGE
Commercial
Grade

Specifications OSC04-I0W OSC04-RIW OSC15-I0W OSC15-RIW


Features
Technology Passive Infrared
Mounting Ceiling
Coverage (SF) 450 1500
Pattern 360°
Mounting Height 8’-10’ 8’-12’ or 12’-20’ 8’-10’ 8’-12’ or 12’-20’
Adjustment Self-Adjusting, Self-Calibrating
Time Delay 30s-30m
Voltage Use with OPP20 Power Pack
Wattage/VA Unlimited Through Use of Power Packs and Add-A-Relays
Occupancy or
Occupancy
Vacancy
Auto or Manual Auto
Sensing Control | Low Voltage

Ambient Light
Yes No Yes No
Override
Other Low Profile, Custom White Color for Shaded Spaces, -R Models Feature Isolated Relay
Mechanical
Switching
Relay
Technology
Neutral Required Yes
Ground Required Yes
Power Pack 24VDC Required
Consumption DC: 10mA AC: 30mA DC: 15mA DC: 10mA AC: 30mA DC: 15mA
20-3000 20-3000
Photocell None None
Lux Adjustable Lux Adjustable
Use OSCxxx-RxW Use OSCxxx-RxW
HVAC Relay Included Included
w/Isolated Relay w/Isolated Relay
Environmental 0 to 40°C/
Operating 0 to 95%
Temperature/ Non-Condensing
Humidity Indoor Use Only
Certifications
Listing UL
CA Title 20
No
Compliant
CA Title 20
Yes
Compliant

32
LOW VOLTAGE
Commercial
Grade

Specifications OSC05-U0W OSC05-RUW OSC10-U0W OSC10-RUW OSC20-U0W OSC20-RUW


Features
Technology Ultrasonic
Mounting Ceiling
Coverage (SF) 500 1000 2000
Pattern 180° 360°
Mounting Height 8’-12’ 8’-20’ 8’-12’ 8’-20’ 8’-12’ 8’-20’
Adjustment Self-Adjusting, Self-Calibrating
Time Delay 30s-30m
Voltage Use with OPP20 Power Pack
Wattage/VA Unlimited Through Use of Power Packs and Add-A-Relays
Occupancy or
Occupancy
Vacancy
Auto or Manual Auto
Ambient Light

Sensing Control | Low Voltage


Yes No Yes No Yes No
Override
Other Low Profile, Custom White Color for Shaded Spaces, -R Models Feature Isolated Relay
Mechanical
Switching
Relay
Technology
Neutral Required Yes
Ground Required Yes
Power Pack 24VDC Required
AC: 45mA DC: AC: 50mA DC: AC: 50mA DC:
Consumption 25mA 35mA 30mA
25mA 30mA 30mA
20-3000 Lux 20-3000 Lux 20-3000 Lux
Photocell None None None
Adjustable Adjustable Adjustable
Use OSCxxx-RxW Use OSCxxx-RxW Use OSCxxx-RxW
HVAC Relay Included Included Included
w/Isolated Relay w/Isolated Relay w/Isolated Relay
Environmental 0 to 40°C/
Operating 0% to 95%
Temperature/ Non-Condensing
Humidity Indoor Use Only
Certifications
UL Yes
CA Title 20
No
Compliant
CA Title 24
Yes
Compliant

www.leviton.com/sensors 33
LOW VOLTAGE
Commercial
Grade

Specifications OSC05-M0W OSC05-RMW OSC10-M0W OSC10-RMW OSC20-M0W OSC20-RMW


Features
Technology Multi-Technology
Mounting Ceiling
Coverage (SF) 500 1000 2000
Pattern 180° 360°
Mounting Height 8’-12’ 8’-12’ or 12’-20’ 8’-12’ 8’-12’ or 12’-20’ 8’-12’ 8’-12’ or 12’-20’
Adjustment Self-Adjusting, Self-Calibrating
Time Delay 30s-30m
Voltage Use with OPP20 Power Pack
Wattage/VA Unlimited Through Use of Power Packs and Add-A-Relays
Occupancy or
Occupancy
Vacancy
Auto or Manual Auto
Sensing Control | Low Voltage

Ambient Light
Yes No Yes No Yes No
Override
Other Low Profile, Custom White Color for Shaded Spaces, -R Models Feature Isolated Relay
Mechanical
Switching Technology Relay
Neutral Required Yes
Ground Required Yes
Power Pack 24VDC Required
AC: 45mA AC: 50mA AC: 50mA
Consumption DC: 25mA DC: 35mA DC: 35mA
DC: 25mA DC: 30mA DC: 30mA
20-3000 20-3000 20-3000
Photocell None None None
Lux Adjustable Lux Adjustable Lux Adjustable
Use Use
Use
OSCxxx-RxW OSCxxx-RxW
HVAC Relay Included OSCxxx-RxW Included Included
w/Isolated w/Isolated
w/Isolated Relay
Relay Relay
Environmental
Operating
0° to 40°C/ 0% to 95% Non-Condensing, Indoor Use Only
Temperature/
Humidity
Certifications
Listing UL
CA Title 20
No
Compliant
CA Title 24
Yes
Compliant

34
LOW VOLTAGE
Commercial
Grade

Specifications OSWWV-I0W OSWWV-RIW OSWHB-I0W OSWHB-RIW OSWLR-I0W OSWLR-RIW OSW12-M0W OSW12-RMW


Features
Technology Passive Infrared Multi-Technology

Mounting Wall, Corner or Ceiling


Coverage (SF) 2500 55x7 100x33.2 1200
Pattern 110° 8° 27°-180° 110°
Mounting Height 8’-10’ 10’-30’ 8’-10’
Adjustment Self-Adjusting, Self-Calibrating
Time Delay 30s-30m
Voltage Use with OPP20 Power Pack
Wattage/VA Unlimited Through Use of Power Packs and Add-A-Relays
Occupancy or
Occupancy
Vacancy
Auto or Manual Auto

Sensing Control | Low Voltage


Ambient Light
Yes No Yes No Yes No Yes No
Override

Wide View, High Bay, Long Range, Multi-Use,


Other -R Models Feature -R Models Feature -R Models Feature -R Models Feature
Isolated Relay Isolated Relay Isolated Relay Isolated Relay

Mechanical
Switching
Relay
Technology
Neutral Required
Yes
Ground Required
Power Pack 24VDC Required
AC:30mA AC:30mA DC: AC:30mA AC: 45mA
Consumption DC: 15mA DC: 15mA DC: 15mA DC: 25mA
DC: 15mA 15mA DC: 15mA DC: 24mA

20-3000 Lux 20-3000 Lux 20-3000 Lux 20-3000 Lux


Photocell None None None None
Adjustable Adjustable Adjustable Adjustable

Use Use Use Use


OSCxxx-RxW OSCxxx-RxW OSCxxx-RxW OSCxxx-RxW
HVAC Relay Included Included Included Included
w/Isolated w/Isolated w/Isolated w/Isolated
Relay Relay Relay Relay
Environmental 0 to 40°C/
Operating 0 to 95%
Temperature/ Non-Condensing
Humidity Indoor Use Only
Certifications

Listing UL

CA Title 20
No
Compliant
CA Title 20
Yes
Compliant

www.leviton.com/sensors 35
Leviton Manufacturing Co., Inc. Global Headquarters
201 N. Service Rd., Melville, NY 11747-3138
tech line 1-800-824-3005 fax 1-800-832-9538

Leviton Manufacturing Co., Inc. Lighting & Energy Solutions


20497 SW Teton Avenue, Tualatin, OR 97062
tel 503-404-5500 fax 503-404-5594
tech line (6:00am–4:00pm PST Monday-Friday) 800-959-6004

facebook.com/leviton twitter.com/leviton youtube.com/levitonmfg

Visit our Website at: www.leviton.com/les

G-7164L/D15-ak
REV APR 2015

©2015 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.
‘USGBC’ and related logo is a trademark owned by the U.S. Green Building Council and is used by permission

The American Recovery And Reinvestment Act of 2009 (“ARRA”) provides federal grants and loans for projects throughout the country. Section 1605 of the Act, named the “Buy American” provision, requires
that certain materials and manufactured products used in projects funded by the Act be manufactured in the United States. The appearance of the Recovery Act Logo in relation to a Leviton product is only
intended to reflect that such product may be used in an ARRA funded project. It does not mean that such product or Leviton is sponsored or endorsed by, or that Leviton receives funds from, the federal
government or the Recovery Accountability and Transparency Board. Nothing in Leviton’s use of the logo is intended to suggest anything regarding the requirements for funding under ARRA.

You might also like