M9
Color Doppler Ultrasound System
Datasheet
Release 1.0
1
Mindray Confidential
Version 1.0
Color Doppler Imaging
1 System Overview Power Doppler Imaging and
1.1 Application Directional PDI
Abdomen Pulsed Wave Doppler
TM
Cardiology iBeam (Spatial Compound
Vascular Imaging)
TM
Obstetrics iClear (Speckle Suppression
Gynecology Imaging)
TM
Small parts iTouch (Auto Image Optimization)
TM
Urology Echo Boost
Breast Zoom/iZoom (Full Screen Zoom)
Pediatrics FCI (Frequency Compound Imaging)
Nerve B steer
Critical Care ExFOV (Extended Field of View)
Emergency Medicine HDR Flow (High Dynamic Range
1.2 Transducer types Flow)
TM
Curved array HR Flow (High Resolution Flow)
Linear array Raw data processing
Phased array 1 active probe port
Pencil 128GB solid hard drive
1.3 Imaging modes 2-USB
B-Mode HDMI
TM
THI and PSH (Phase Shift Harmonic Internal WIFI
Imaging) UltraAssist (Off-line software)
M-Mode/Color M-mode ‐ iStorage
TM
Free Xros M (Anatomical M-mode) Built-in Battery
TM
Free Xros CM (Curved Anatomical Power adapter
M-mode) Control panel film with language
Color Doppler Imaging 1.5 Optional features
Power Doppler Imaging/Directional Continuous Wave Doppler
TM
PDI Free Xros M
TM
Pulsed Wave Doppler Free Xros CM
TM
Continuous Wave Doppler iScape View
+ TM
TDI UWN Contrast Imaging
+
UWN (Ultra-Wideband Non-linear Contrast Imaging QA (Quantitative
Plus) Contrast ImagingTM Analysis)IMT
Tissue Tracking QA Elastography
Stress Echo TDI (Include TVI, TVD, TVM, TEI)
Elastography TDI QA (TDI Quantitative Analysis)
TM
iScape View (Panoramic Imaging) TT QA (Tissue Tracking Quantitative
1.4 Standard features Analysis)
B-Mode LVO(Left Ventricular Opacification)
TM
THI and PSH Stress Echo
M-Mode DICOM
2
Mindray Confidential
Version 1.0
Clinical Measurement Package 15.6-inch high resolution color LED
TM
Smart OB (Auto OB measurement) monitor
TM
Smart NT (Auto NT measurement) Resolution: 1920×1080
TM
iWorks (Auto Workflow Protocol) Automatic brightness adjustment
TM
iNeedle (Needle Visualization Screen Saver
Enhancement) Open angle adjustable: 0°-150° (The
Moble Trolley: UMT-500, angle between the monitor and
UMT-500Plus control panel)
Audo/Video extend module: View angle (right/left): 89°
iDock51 2.3 Handle
ECG function 2.4 Probe port
Barcode reader: 1 port connect to a transducer or the
DS6707-SR (2D Barcode), probe extend module
SYMBOL LS2208-SR (1D Barcode) 1 pencil probe port
Footswitch: 1-pedal/2-pedal/3-pedal 2.5 Electrical power
External DVD R/W driver AC adapter Input:
1.6 Language support ‐ Voltage:100-240V~Frequency:
Software: English, Chinese, German, 50/60 Hz
Spanish, French, Italian, Portuguese, ‐ Power input: 2.0A max
Russian, Czech, Polish, Turkish, Battery: Lithium-Ion Battery Pack
Norwegian, Serbian 14.8V , 5800mAh (single battery)
Keyboard input: English, Chinese, 2.6 Operating Environment
German, Spanish, French, Italian, Ambient temperature: 0-40 °C
Portuguese, Russian, Czech, Polish Relative humidity: 30%-85% (no
Icelandic, Norwegian, Swedish, condensation)
Finnish, Turkish, Danish, Hungarian, Atmospheric pressure:
Serbian 700hPa-1060hPa
Control panel overlay: Chinese, 2.7 Storage & Transportation Environment
Italian, Portuguese, Spanish, Ambient temperature: -20~55 °C
German, Russian, French, Czech, Relative humidity: 20%-95% (no
Polish condensation)
User manual: English, Chinese, Atmospheric pressure:
German, Spanish, French, Italian, 700hPa-1060hPa
Portuguese, Russian 2.8 Alloy Enclosure
Magnesium-alloy enclosure design
2 Physical Specification
2.1 Dimension and weight
3 User Interface
Width: 390mm 3.1 Control panel
Depth: 362mm Power/Battery Indicator
Height: 59mm Alphanumeric Keys
Weight: approx. 5.8kg (with Function Keys
batteries), 5kg (no accessories or Ergonomic Soft Key Operation
batteries) Backlit keys, ensuring accurate work
2.2 Monitor in the dark room
3
Mindray Confidential
Version 1.0
8-segment TGC control Help guidance
Programmable keys, available for Dynamic Trackball indices
user-defined functions
Trackball, speed adjustment *Not all items are listed in this part, detail
Key Brightness adjustment info please refer to user manual.
Integrated speakers, audio volume
adjustment
4 Imaging Parameters
3.2 System boot-up 4.1 Overview
Boot-up from complete shut-down Digital beamformer
in about 28 sec Up to 82,944 channels
Boot-up from standby mode in 12-beam forming
about 7 sec 4.2 B-mode
Shut down in about 12 sec Display formats: Single(B),
3.3 Comments Dual(B+B), Quad(4B)
TM
Supports text input and arrow iClear : Off; On, 1-7 steps
TM
Adjustable text size and arrow size iBeam : Off; On, 1-3
TM
and direction iTouch : Auto optimization (TGC,
Supports home position Gain)
Covers various application Image quality: Pen/Gen/Res (depend
More than 800 comments items for on probe)
versatile application B steer: available on linear
User customizable transducers
3.4 Bodymark ExFOV: extended FOV available on
More than 140 bodymarks for convex and linear transducers
versatile application Depth: 1.5-40cm (depend on
User customizable transducer )
3.5 Screen information* (presettable) Frame rate (max): 1000f/s
Common info: Acoustic output power: 3.2%-100%
Mindray logo TGC: 8 pods on control panel
Hospital name LGC: 4 segments on soft menu (4
Exam date levels of preset values)
Exam time Dynamic range: 30-200, 5/step
Acoustic power Gain: 0-100, 1/step
Mechanical index Focus number: 1-4, adjustable
Tissue thermal index Focus position: Max. 16, adjustable
ID, Last name, First Name, Middle FOV (Field of View): on/off
initial, Gender, Age Line density: L/M/H/UH
Probe model Persistence: 0-7, 8 steps
ECG icon (when ECG connected) Horizontal Scale: on/off
Operator L/R flip: Right/Left
TGC Curve U/D flip: Up/Down
Focus position Rotation: 0°, 90°, 180°, 270°
Thumbnail TSI (Tissue Specific Imaging):
Imaging parameters general/muscle/fluid/fat
4
Mindray Confidential
Version 1.0
Gray Map: 8 types Acoustic output power: 3.2%-100%
Tint: on/off Gain: 0-100, 1/step
Tint map: off; 8 types Speed: 6 levels
Auto Merge: on/off Tint: on/off
4.3 THI and PSH Tint map: off; 8 types
Available on all types of Gray Map: 8 types
transducer(except CW2s and CW5s) 4.7 Color Doppler Imaging
TM
Patent PSH technology, obtains Dual live: on/off
TM
purer harmonic, better contrast HR Flow : High Resolution Flow
resolution, higher SNR, exceptional provides better image quality and
high frequency harmonic flow sensitivity
TM
iClear available Image quality: Pen/Gen/Res
Image quality: HPen/HGen/HRes Max velocity: 239cm/s
or HPen/ HPen-Gen/HGen/HRes Steer: max. 30 degrees (linear
(depends on probe) transducer)
4.4 M-mode Max frame rate: 293f/s
Display formats: V2:3, V3:2, H2:3, Acoustic output power: 3.2%-100%
V3:1,Full (V: vertical, H: horizontal, L: Gain: 0-100, 2/step
left, R: right) ROI size/position: adjustable
Color M-mode available (convex and Scale: 30 levels
phased probe only) Wall filter: 0-7, 8 steps
Acoustic output power: 3.2%-100% PRF: max. 15.5kHz, min.0.1kHz
Dynamic range: 30-180, 5/step Packet size: 0-3, 4 steps
Gain: 0-100, 1/step Flow state: L/M/H, 3 steps
Speed: 6 levels Smooth: 0-6, 7 steps
M soften: 0-4, 5 steps B/C Align: on/off
Tint: on/off Priority: 0%-100%, 1%/step
Tint map: off; 8 types Color map: V0-V10, VV0-VV9, 21
Gray Map: 8 types types (Variance)
Edge enhance: 0-3 Invert: on/off
4.5 Free Xros M (option) Persistence: 0-6, 7 steps
Display formats: V2:3, V3:2, H2:3, Line density: L/M/H/UH, 4 steps
V3:1 (V: vertical, H: horizontal, L: left, 4.8 Power Doppler Imaging
R: right) Dual live: on/off
TM
Color Free Xros M available HR Flow : High Resolution Flow
Up to 3 lines provides better image quality and
Speed: 6 levels sensitivity
Tint: on/off Support directional power doppler
Tint map: off; 8 types Image quality: Pen/Gen/Res
Gray Map: 8 types Acoustic output power: 3.2%-100%
4.6 Free Xros CM (option) Dynamic range: 10-70, 5/step
Display formats: V2:3, V3:2, H2:3, Gain: 0-100, 2/step
V3:1, (V: vertical, H: horizontal, L: left, ROI size/position: adjustable
R: right) Steer: max. 30 degrees (linear
5
Mindray Confidential
Version 1.0
transducers) steps
Scale: 30 steps Auto calc: on/off
Wall filter: 0-7, 8 steps Auto calc cycle: 1-5, 1/step
PRF: max. 15.5kHz, min.0.1kHz Trace area: above, below, all
Packet size: 0-3, 4 steps Trace Sensitive: 0-5, 6 steps
Flow state: L/M/H Trace Smooth: 0-4, 5 steps
Smooth: 0-6, 7 steps Duplex/Triplex: on/off (both
B/C align: on/off supporting PW & CW duplex/triplex)
Priority: 0%-100%, 1%/step 4.10 Tissue Velocity/Energy Imaging
Color map: 4 types (included in TDI option)
Directional color map: 4 types Available on phased array
Persistence: 7 steps transducer
Line density: L/M/H/UH Dual live: side by side displays B and
4.9 PW/CW-Mode B+TVI
Display formats: V2:3, V3:2, H2:3, Max frame rate: 1553f/s
V3:1, Full (V: vertical, H: horizontal, L: PRF: max. 15.2kHz, min. 0.3kHz
Left) Acoustic output power: 3.2%-100%
TM
iTouch : on/off, auto optimization Gain: 0-100, 2/step
(Baseline, PRF) Dynamic range: 10-70, 5/step (TEI
Image quality: Pen, Gen, Res only)
PW velocity: max. 921cm/s ROI size/position: adjustable
CW velocity: max. 3841cm/s Scale: max. 30 steps, 5.0-150cm/s
Sample volume size: 0.5-20mm (PW Baseline: -8~8, 17 steps (TVI only)
only), 0.5-5mm/step Wall filter: 0-7, 8 steps
Sample gate depth: adjustable Packet size: 0-3, 4 steps
Scale: max. 3841cm/s Flow state: L/M/H, 3 steps
Baseline: -4~4, 9 steps Smooth: 0-6, 7 steps
PW Steer: max. 30 degrees (linear B/C Align: on/off
transducer) Priority: 0%-100%, 1%/step
Volume: 0%-100%, 2%/step Map: 10 types
PW PRF: max. 24kHz, min. 0.7kHz Invert: on/off (TVI only)
CW PRF: max. 100kHz, min. 0.7kHz Persistence: 0-6, 7 steps
Gain: 0-100, 2/step Line density: L/M/H/UH, 4 steps
Dynamic range: 24-72, 2/step 4.11 Tissue Velocity Doppler(included in
Sweep speed: 6 levels TDI option)
Wall filter: 0-6, 7 steps Available on phased array
Invert: on/off transducer
Auto invert: on/off Display formats: V2:3, V3:2, H2:3,
Angle: -89°~89°, 1/step V3:1, Full (V: vertical, H: horizontal, L:
Quick angle: 0°, -60°, 60° left, R: right)
Tint: on/off Sample volume size: 0.5-20mm , 12
Tint map: off, 8 types steps
HPRF: on/off Sample gate depth: adjustable
Time/frequency resolution: 0-4, 5 Scale: max. 368.75 cm/s
6
Mindray Confidential
Version 1.0
Baseline: -4~4, 9 steps
reduces deeper tissue artifacts,
Volume: 0%-100%, 2%/step obtains more uniform stress
PRF: max. 24.0kHz, min. 0.7kHz throughout whole field
Gain: 0-100, 2/step Stress indicator: supports frame by
Dynamic range: 24-72, 2/step frame stress indication
Speed: 6 levels Display format: Dual live, Single E
Wall filter: 0-6, 7 steps Elasto Map: 6 types
Invert: on/off Smooth: 6 steps
Angle correction: -89°~89°, 1/step Invert: on/off
Quick angle: 0°, -60°, 60° Opacity: 6 steps
Gray map: 10types 4.16 UWN+ Contrast ImagingTM* (option)
Tint: on/off Ultra Wideband Non-linear Plus
Tint map: Off; 8 types contrast imaging technology, which
Time/frequency resolution: 0-4, 5 provides exceptional contrast agent
steps detecting capability, not only
4.12 Tissue Velocity Motion (included in extracts second harmonic, but also
TDI option) non-linear fundamental signals
Display formats: V2:3, V3:2, V 3:1, Supports Low MI contrast imaging
H2:3, FULL (V: vertical, H: horizontal) Micro Flow Enhancement (MFE)
Acoustic output power: available
3.2%-100%Gain: 0-100, 2/step Available for C5-1s
M sweep speeds: 6 steps Available for Abdomen, Ped-ABD,
M soften: 5 steps ABC-Difficult
Gray Map: 8 types Timer1: on/off
Edge enhancement: 4 steps Timer2: on/off
4.13 iScapeTM View (option) Pro capture: captures prospective
Panoramic imaging image less than 480s
Available on all transducers Retro capture: captures
Acquisition method: B retrospective image less than 120s
Imaging length: 100cm Dual live: side by side displays tissue
Tint map: off; 8 types image and contrast image
Rotation: 0°~355° MFE: on/off
4.14 Zoom Destruct: instantly destroy contrast
TM
iZoom bubbles
‐ Full screen zoom iClear: off; 7 steps
‐ Normal image, Zoom standard Mix: mix contrast image with tissue
area, Zoom image area, 3 steps image
Spot zoom (write zoom) 0.8-10x Mix map: 7 types, available when
Pan zoom (read zoom) 0.8-10x Mix mode is active
4.15 Elastography (option) Persistence: 8 steps
Available on all linear transducers MFE period: 0.1s, 0.2s, 0.4s, 0.6s, 0.8s,
Support strain ratio measurement 1.0s, MAX
Unique shell analysis function Dynamic range: 30-180, 5/step
Stress compensation technology Gray map: 8 types; inactive when
7
Mindray Confidential
Version 1.0
Mix mode is in use Image acquisition
Tint map: off; 10 types ‐ R-wave trigger
Supports U/D Flip and L/R Flip ‐ Acquire mode: Manual ROI or full
Rotation: 90 degrees/step screen
HImgPos: transpose position of ‐ Ability to acquire frames or clips in
contrast and tissue image B-mode, LVO
Line density: L/M/H/UH Image selection
DestructAP: -43.4~0 dB ‐ Attach the images with view
Destruct time: 500-2000 ms annotation label (PSLA, PSAX, A4C,
A2C, and customized views)
*The M9 is designed for Review
compatibility with commercially ‐ Automatically adjust to the
available ultrasound contrast agents. number of images user defined
Because the availability of these Wall Motion Scoring
agents is subject to government ‐ ASE 16 (with score 4-7), or ASE 17
regulation and approval, product (with score 4-7)
features intended for use with these ‐ Graphical display of scoring
agents may not be commercially (Normal, Hyperkinetic, Severely
marketed nor made available before Hyperkinetic, Akinetic, Dyskinetic)
the contrast agent is cleared for use. LV volume measurement
Contrast related product features ‐ Measurement of LV Volume in all
are enabled only on systems for phases of cardiac cycle
delivery to an authorized country or Report
region of use. Mindray medical ‐ Reporting for both Wall Motion
systems makes no claims concerning Scoring and LV volume
the safety or effectiveness of measurement
contrast agents. 4.18 LVO(option)
Available on SP5-1s
4.17 Stress Echo(option) Dedicated left ventricle contrast
Available on cardiac sector imaging tool
transducers 4.19 iBeamTM
14 factory protocols Spatial compound imaging
User-defined protocols 9 angles maximum
ECG triggered acquisition, display, Available on all convex and linear
selection, comparison, evaluation transducers
and archiving of multiple cardiac 4.20 iTouchTM
loops during various stages of a Auto image optimization
stress echo examination B-mode: gain, TGC
ASE 16 (with score 4-7), ASE 17 (with Color: gain
score 4-7) Power: gain
Customized stages: up to 6 views per PW: gain, scale, PRF, WF
stage, and up to 12 stages per study Contrast imaging: gain
View: standard views (PSLA, PSAX, 4.21 Echo BoostTM
A4C, A2C), and customized views Only for cardiac exams
8
Mindray Confidential
Version 1.0
Improve the homogeneity of cardiac A2C, PSAXB, PSAXM, PSAXAP
images through the whole field of Reload: reload cine again for new
view study
Better contrast resolution of Edit: modify trace points
myocardium tissue layers Start tracking
Better noise control in cardiac Accept & compute: start tracking
chambers and muscles myocardium movement when user
4.22 B steer accept trace result
Only for linear transducers Display effect: 0/1; at 0, tracking in
4.23 ExFov velocity vector arrow; at 1, tracking
Extended field of view in dots
Available for all convex, linear and Trace method: 3 point or manual for
volume transducers ALAX, A4C, A2C; manual for PSAXB,
4.24 Zoom PSAXM, PSAXAP
Zoom: Spot zoom (write zoom) up to Bull’s eye: trace result in bull’s eye
10x, Pan zoom (read zoom) 0.8x-10x model
iZoom: convertible 3 steps ;normal LGC: available
image, zoom standard area, zoom Valve’s open and close time index:
only image area MVC, MVC’, AVC, AVO, MVO
4.25 QSave Data export: export data in CSV file
Quick save image parameter setting Cycle: ECG triggered cardiac cycle
after image adjustment done recognition for analysis; cycle from
Support Save, Save as, Restore 1-10, 1/step
4.26 TDI QA (option) Auto play: stop, X1/10, X1/5, X1/4,
Dedicated quantification tool for TDI X1/3, X1/2, X1, X2, X3
velocity, strain, strain rate analysis Thickness: 1-30mm, 1mm/step;
Ellipse ROI, Standard ROI adjust trace thickness
Up to 8 of ROI Track point: 20-40, 1/step
Delete all Parameter: Volume, Speed,
Delete current Displacement, L Strain, L Strain R, T
ROI tracking: tracking ROI along Strain, T Strain R, Area, R Strain, R
with cardiac movement Strain R, C Strain, C Strain R
Smooth: 1-7, 1/step Smooth: 0-4, 1/step
X scale: 1-5,1/step 4.28 Contrast Imaging QA (option)
Std.Height: 1.5-50 mm Support Time-Intensity Curve
Std.Width: 1.5-50 mm analysis
Std.Angle: -89-90 degrees Table display: display data in table
Export: export current data as CSV Freehand ROI: manually deploy ROI
format file on the cine
4.27 TT QA (option) Up to 8 ROIs
Tissue tracking quantitative analysis Delete all
Mandatory ECG connection before Delete current
TT QA cine acquisition Fit curve
Six views for analysis: ALAX, A4C, Raw curve
9
Mindray Confidential
Version 1.0
Motion tracking: Reduce the effect
Gain
of tissue movement Dynamic range
XScale: 5 steps Gray map
4.29 iNeedleTM (option) Tint map
Needle visualization enhancement Flip
Best angle indicator Rotation
Available on all linear transducers M-mode:
Needle steer: -50, -40, -30, -20, 20, 30, Speed
40, 50 degrees Dynamic range,
Gain,
5 Cine Review and Post Processing Gray map,
5.1 Cine review Tint map,
Available in all modes Edge enhancement
Frame by frame manual cineloop Color:
review or auto playback with Gain
variable speed Invert
Independent cine review in 2D Dual Smooth
and Quad mode one by one Baseline
Maximum cine memory is up to Color map
38037 frames or 335.8s (depend on Priority
the mode) Velocity tag
Retrospective storage (1-120s, or PW:
1-120 cycles, pre-settable) and Baseline
prospective storage (1-480s, or Wall filter
1-390cycles, pre-settable) Speed
Frame compare: compare different Angel correction
frames for one cine in dual format Quick angel
Cine compare: compare two or more Invert
than two cines in dual or quad Audio
format T/F Res
Jump to first and jump to last: one Dynamic range
keystroke review the first or last Gray map
frame Tint map
Start point and end point: selectable
5.2 Raw data processing
6 Measurement/Analysis and
B-mode:
iClearTM
Report*
Zoom 6.1 Generic measurements
TGC 2D-mode
LGC ‐ Depth
HScale ‐ Distance
Dual live ‐ Area: Ellipse, Trace, Spline, Cross
Auto merge ‐ Trace Length
iTouch brighness ‐ Double Distance
10
Mindray Confidential
Version 1.0
‐ Parallel ‐ Spleen
‐ Volume :3-Distance, Ellipse, Ellipse ‐ Left/Right Kidney: Length, Width,
+ Distance) Height, Volume, Cortical Thickness
‐ Length Ratio ‐ Left/Right Adrenal Gland: Length,
‐ Area Ratio Width, Height
‐ IMT ‐ Abdominal Aorta Diameter
‐ B Histogram ‐ Abdominal Aorta Bifurcate
‐ B Profile Diameter
‐ Volume Flow ‐ Iliac Diameter
‐ Color Velocity ‐ Bladder: Length, Width, Height,
M-mode Volume, micturition volume
‐ Distance ‐ Common Hepatic Artery
‐ Time ‐ Hepatic Artery
‐ Slope ‐ Portal Vein, Main Portal Vein
‐ Heart Rate ‐ Hepatic Vein, Left Hepatic Vein,
‐ Velocity Middle Hepatic Vein, Right Hepatic
Doppler mode Vein
‐ D Velocity ‐ Splenic Artery
‐ Time ‐ Splenic Vein
‐ Heart Rate ‐ Left/Right Renal Artery, Main Renal
‐ Acceleration Artery, Renal Artery Origin,
‐ D Trace Arcuate Artery, Segmental Artery,
‐ PS/ED Interlobar Artery, Renal Vein
‐ Volume Flow ‐ Abdominal Aorta
Automatic Doppler Spectrum ‐ Celiac Axis
Analysis ‐ Superior Mesenteric Artery
‐ Heart cycle pre-settable (1, 2, 3, 4, ‐ Inferior Vena Cava
5) ‐ Superior Mesenteric Vein
‐ Automatic real-time and Gynecology
retrospective tracing ‐ Cervix: Length, Width, Width
‐ User configurable display of items ‐ Uterus: Length, Width, Height,
‐ Support PI, RI, TAMAX, TAMEAN, Volume, Uterus body,
Volume Flow calculations Endometrium Thickness
‐ Appropriate factory setting ‐ UT-L/CX-L
according to applications ‐ Ovary: Length, Width, Height,
6.2 Clinical option measurement package Volume
Abdominal ‐ Follicle: Length, Width, Height,
‐ Liver Average Diameter, Volume
‐ Common Hepatic Duct Obstetrics
‐ Portal Vein Diameter ‐ Early OB: GS, YS, CRL, BPD, FL, NT,
‐ Gall Bladder: Length, Height, Wall Amniotic Fluid
Thickness ‐ 2nd- 3rd Trimester: BPD, HC, OFD,
‐ Common Bile Duct FL, AC, AF, NF, PL Thickness, TAD,
‐ Pancreas: Head, Body, Tail, Duct APAD, TCD, Cisterna Magna, HW,
11
Mindray Confidential
Version 1.0
OOD, IOD, Orbit, HUM, Ulna, RAD, ‐ Left/Right Kidney: Length, Width,
Tibia, FIB, CLAV, Vertebrae, MP, Height, Volume, Cortical Thickness
Foot, Ear, APTD, TTD, FTA, THD, ‐ Left/Right Adrenal Gland: Length,
HrtC, TC, Umb VD, F-Kidney, Mat Width, Height
Kidney, Cervix L(Trace available) ‐ Left/Right Testis: Length, Width,
‐ Fetal Heart: LVIDd, LVIDs, LV Diam, Height
LA Diam, RVIDd, RVIDs, RV Diam, ‐ Left/Right Seminal Vesicle: Length,
RA Diam, IVSd, IVSs, IVS, LV Area, Width, Height
RV Area, RA Area, Ao Diam, MPA Vascular
Diam, LVOT Diam, RVOT Diam, ‐ Carotid: CCA, ECA, ICA, Bulb, Vert A,
‐ Gestational Age Subclav A
‐ Fetal Growth ‐ Upper Extremity Artery: Subclav A,
‐ Fetal Trend Graph Axill A, Brachial A, Radial A, Ulnar A,
‐ Estimated Fetal Weight Innom A
‐ Multi-gestational Calculations ‐ Upper Extremity Vein: Cephalic V,
‐ Fetal Biophysical Profile Basilic V, Ulnar V, Radial V
‐ User definable OB tables ‐ Lower Extremity Artery: CFA, SFA,
‐ Z-score Pop A, TP Trunk A, Peroneal A, P.TIb
Cardiology A, A.Tib A, Dors. Ped A,
‐ LV Function: Teichholz, Cube, ‐ Lower Extremity Vein: C.Iliac V,
Gibson, Simpson Single-plane, Ex.Iliac V, Femoral V, Saph V, Pop V,
Simpson Bi-plane, Modified TP Trunk V, Sural V, Soleal V,
Simpson, Bullet, S-P Ellipse, B-P Peroneal V, P.Tib V, A.Tib V
Ellipse ‐ TCD (Transcranial Doppler): ACA,
‐ Auto LV: auto measurement in MCA, PCA, Basilar, A Comb.A, P
Simpson method Comb.A, Vertebral A, Basilar A
‐ LV Mass: Area-Length Method, Small Parts
Truncated-Ellipsoid Method, Cube ‐ Thyroid: Length, Height, Width,
Method Volume
‐ Atrial Volume: LA Vol(A-L), LA ‐ Isthmus Height
Vol(Simpson), RA Vol(Simpson) ‐ Testis: Length, Height, Width
‐ LVIMP ‐ Mass: Length, Height, Width, Nip.
‐ LV TEI, RV TEI Distance, Skin Distance
‐ Qp/Qs ‐ Superior Thyroid Artery
‐ PISA MR, AR, TR, PR ‐ Inferior Thyroid Artery
‐ MVA(VTI), AVA(VTI) Orthopedics
‐ MV medial/lateral (TDI) ‐ Hip
Urology ‐ d/D
‐ Prostate: Length, Width, Height, 6.3 Report
Volume Specific report template by
‐ PPSA, PSAD application
‐ Ureter Diameter User-defined report template
‐ Bladder: Length, Width, Height, Editable value in report
Volume, micturition volume Images selectable
12
Mindray Confidential
Version 1.0
Able to Export as PDF/RTF file ‐ Standard area:120*910
6.4 IMT ‐ Full-screen: 1920*1080
Intima-Media Thickness 7.2 Exam management
TM
Measurement iStation workstation dedicated for
Automatic detection of IMT when patient exam management
ROI is set Patient exam query/retrieve
Support CCA, ICA, ECA, Bulb IMT Support review of current and past
Near wall and far wall detection exam
Angle selectable New exam, Active exam, Continue
Support IMT growth curve exam functions, End exam are
6.5 Smart OBTM available
Auto measurement for OB, a special Support measurements and
tool for easy OB scan, and greatly calculations on archived exam and
reduce time and increase images
productivity Export image as
Support BPD, HC, OFD, FL, AC BMP/JPG/TIFF/DCM/FRM format
Better get GA before start auto AC (FRM: system format)
Measurement result can be modified Export cine as DCM/AVI/CIN format
by user (CIN: system format)
6.6 Smart NT Support backup/send to USB
NT auto measurement devices, DVD-RW media
Auto detection of NT inside ROI 7.3 iWorksTM (option)
6.7 iStorage (included in UltraAssist) Auto workflow protocol
Data transfer Templates are user configurable
6.8 iReport (embedded in M9) Functions: pause, stop, replace,
User-defined report template repeat, skip, insert single step,
software return and continue, steps in
thumbnail, iNSertTM another
* Not all measurements are listed in this template
part; For more detailed information iWorks setup mode:
please refer to User Manual B/Dual/B+Color/B+
PW/B+Color+PW/B+CW/B+Color+C
7 Exam Storage and Management W/ B+M
7.1 Exam storage iWorks setup annotation: support up
128GB hard drive. More than 76GB to 2 annotations, location and font
internal hard drive reserved for size are configurable
patient data storage iWorks setup bodymark: select
Capable of storage up to existing library, and probe indicator
approximately 109875 single frames is pre-settable
(FRM format) iWorks setup measurement: select
Storage area existing measurement library
‐ Pre-settable: image area, standard Template import and export are
area, full-screen available
‐ Image area: 1000*790
8 Connectivity
13
Mindray Confidential
Version 1.0
8.1 Ethernet Network Connection 6.0 MHz
Wired connection ‐ Doppler Frequencies: 2.0, 2.5 MHz
Wireless connection: Wireless ‐ Biopsy Guide: NGB-022, available,
Ethernet adapter(option) multi angle, reusable
8.2 DICOM 3.0 V11-3Ws
DICOM Basic (option) ‐ Application: Gynecology,
‐ Verify (SCU, SCP) Obstetrics, Urology
‐ Print ‐ Bandwidth: 3-11.2 MHz (-20dB)
‐ Store ‐ Number of Elements: 160
‐ Storage Commitment ‐ FOV (max): 173°
‐ Media Exchange ‐ Extended FOV: 180°
DICOM Worklist (option) ‐ Convex Radius: 11 mm
DICOM Query/Retrieve (option) ‐ Physical Footprint: 24.9mm
DICOM Modality Performed ×21.8mm
Procedure Step - MPPS (option) ‐ Footprint: 24mm×9mm
DICOM OB/GYN structure report ‐ B-mode Frequencies: 2.6-6.5,
(option) 3.2-7.9, 4.7-12.8MHz
DICOM Cardiac structure report ‐ Harmonic Frequencies: 7.0, 8.0,
(option) 9.0MHz
DICOM Vascular structure report ‐ Doppler Frequencies: 4.4, 5.0MHz
(option) ‐ Biopsy Guide: NGB-004, available,
DICOM Breast structure report single angle, reusable
(option) C11-3s
8.3 iStorage (included in UltraAssist) ‐ Application: Abdomen, Pediatrics,
Direct network storage tool between Transcranial, Vascular, Small parts,
ultrasound system and personal Musculoskeletal
computer ‐ Bandwidth: 3-11.2MHz (-20dB)
‐ Number of Elements: 128
9 Probes ‐ FOV (max): 100°
9.1 Curved array ‐ Extended FOV: 121°
C5-1s ‐ Convex Radius: 15mm
‐ Application: Adult Abdomen, ‐ Physical Footprint: 32.8mm×25mm
Gynecology, Obstetrics ‐ Footprint: 27.4mm×8.4mm
‐ Bandwidth: 1.4-5.1 MHz (-20dB) ‐ B-mode Frequencies: 2.6-6.5,
‐ Number of Elements: 128 3.2-7.9, 4.7-12.8MHz
‐ FOV (max): 61° ‐ Harmonic Frequencies: 7.0, 8.0,
‐ Extended FOV: 101° 9.0MHz
‐ Convex Radius: 60mm ‐ Doppler Frequencies: 4.4, 5.0MHz
‐ Physical Footprint: 76.5mm× ‐ Biopsy Guide: NGB-018, available,
28mm multi angle, reusable
‐ Footprint: 64.9mm × 16.2mm 9.2 Linear array
‐ B-mode Frequencies: 1.3-3.2, L12-4s
1.9-4.6, 2.3-5.7 MHz ‐ Application: Small parts, Vascular,
‐ Harmonic Frequencies: 3.5, 4.0, 5.0, Pediatrics, Superficial,
14
Mindray Confidential
Version 1.0
Musculoskeletal, Neurology ‐ Physical Footprint:
‐ Bandwidth: 3-13MHz (-20dB) 38.2mm×30.5mm
‐ Number of Elements: 192 ‐ Footprint: 23.4mm×15.2mm
‐ Field of View (max): 38mm ‐ B-mode Frequencies: 1.0-3.5,
‐ Steered Angle: ±6°/±12° (B Steer), 2.0-4.0, 2.5-5.0MHz
±10°/±20°/±30° (Color/PW Steer) ‐ Harmonic Frequencies: 3.0, 3.4,
‐ Physical Footprint: 3.8MHz
45.7mm×10.9mm ‐ Doppler Frequencies: 2.0, 2.3,
‐ Footprint: 44.2mm×8.5mm 2.5MHz; TDI 3.0, 3.8MHz
‐ B-mode Frequencies: 4.4-9.6, ‐ CW Frequency: 2MHz
5.4-11.5, 6.6-13.5MHz ‐ Biopsy Guide: NGB-011, available,
‐ Harmonic Frequencies: 8.0, 9.0, multi angle, reusable
10.0MHz P10-4s
‐ Doppler Frequencies: 4.4, 5.0, ‐ Application: Neonatal Cardiac,
5.7MHz Transcranial
‐ Biopsy Guide: available, multi ‐ Bandwidth: 2.9-10.5MHz (-20dB)
angle, reusable ‐ Number of Elements: 96
L14-6Ns ‐ Field of View (max): 90°
‐ Application: Small parts, Vascular, ‐ Physical Footprint:
Pediatrics, Superficial, 15.1mm×10.2mm
Musculoskeletal, Neurology ‐ Footprint: 15.0mm×9.1mm
‐ Bandwidth: 3.5-16 MHz (-20dB) ‐ B-mode Frequencies: 3.2-6.8,
‐ Number of Elements: 192 3.8-10.2, 4.6-11.4MHz
‐ Field of View (max): 38mm ‐ Harmonic Frequencies: 7.5, 8.0,
‐ Steered Angle: ±6°/±12° (B Steer), 9.0MHz
±10°/±20°/±30° (Color/PW Steer) ‐ Doppler Frequencies: 4.0, 5.0,
‐ Physical Footprint: 5.7MHz; TDI 5.7, 6.2MHz
45.7mm×10.9mm ‐ CW Frequency: 5MHz
‐ Footprint: 44.2mm×8.5mm ‐ Biopsy Guide: not available
‐ B-mode Frequencies: 5.4-11.6, P7-3Ts
6.0-12.6, 6.6-13.5MHz ‐ Application: Transesophageal Echo
‐ Harmonic Frequencies: 8.0, 10.0, ‐ Bandwidth: 1.9-8.2MHz (-20dB);
12.0MHz ‐ Number of Elements: 64
‐ Doppler Frequencies: 5.0, 5.7, ‐ Field of View (max): 90°
6.6MHz ‐ Physical Footprint: 14mm×12mm
‐ Biopsy Guide: NGB-007, available, ‐ Footprint: 14mm×12mm
multi-angle, resuable ‐ B-mode Frequencies: 2.3-5.4,
9.3 Phased array 2.8-6.4, 3.3-7.2MHz
SP5-1s ‐ Harmonic Frequencies: 6.0, 6.5,
‐ Application: Adult Cardiac, 7.0MHz
Transcranial, Pediatric Abdomen ‐ Doppler Frequencies: 2.7, 3.3,
‐ Bandwidth: 1.1-4.4MHz (-20dB) 4.0MHz; TDI 5.0, 6.2
‐ Number of Elements: 80 ‐ CW Frequency: 2.5MHz
‐ Field of View (max): 90° ‐ Biopsy Guide: not available
15
Mindray Confidential
Version 1.0
9.4 CW probe UMT-500
CW2s ‐ External DVD R/W Storage
‐ Application: Transcranial, Cardiac, ‐ Platform Height: 809-1059mm
Pediatrics adjustable
‐ Number of Elements: 2 UMT-500Plus
‐ CW Frequency: 2.0MHz ‐ Power supply module
‐ Biopsy Guide: not available ‐ External DVD R/W Storage
CW5s ‐ Platform Height: 809-1059mm
‐ Application: Vascular adjustable
‐ Number of Elements: 2 ‐ Built-in battery for trolley,
‐ CW Frequency: 5.0MHz continuous work time: about 2h in
‐ Biopsy Guide: not available B mode
10.8 Barcode reader
‐ 1-D barcode reader: SYMBOL
10 Peripheral Devices and LS2208
‐ 2-D barcode reader: SYMBOL
Accessories (Option) DS6707
10.1 Probe extend module:PEM-51
One extend three probe ports
11 System Inputs and Outputs
10.2 Black/white digital video printer 11.1 I/O Port
SONY UP-D897 USB3.0: 2 ports
MITSUBISHI P95DW-N ECG: 1 port
10.3 Color digital video printer HDMI: 1 port
SONY UP-D25MD 11.2 Video/Audio Extend port
10.4 Digital graph/text printer Video/Audio Extend module
HP Deskjet 1050 J410 series iDock51 (option)
HP OfficeJet 7000 wide format ‐ S-Video Output: 1 port
HP OfficeJet Pro 8100 ‐ VGA: 1 port
10.5 Footswitch ‐ Audio Output: 1 port
USB port: 971-SWNOM
(2-pedal/3-pedal)
12 Safety and Conformance
USB port: FS-81-SP (1-pedal) 12.1 Quality standards
Support User-definable functions ISO 9001
(Freeze, Save, Print) ISO 13485
10.6 Built-in Battery for Main Unit 12.2 Design standards
Replaceable and rechargeable CSA C22.2 No. 601-1
lithium battery EN 60601-1 and IEC 60601-1
Full battery lasts more than 24h in EN 60601-1-2 and IEC 60601-1-2
standby mode EN 60601-1-6 and IEC 60601-1-6
Empty battery recharged to full in EN 60601-2-37 and IEC60601-2-37
4h EN 62304 and IEC 62304
Continuous work time: about 1.5 EN 62366 and IEC 62366
hour in B mode EN ISO 17664 and ISO 17664
10.7 Mobile Trolley 12.3 CE declaration
16
Mindray Confidential
Version 1.0
M9/M9CV system is fully in
conformance with the Council
Directive 93/42/EEC Concerning
Medical Devices, as amended by
2007/47/EC. The number adjacent to
the CE marking (0123) is the number of
the EU-notified body that certified
meeting the requirements of Annex II
of the Directive.
NOTICE:
Not all features or specifications described
in this document may be available in all
probes and/or modes.
Mindray reserves the right to make
changes in specifications and features
shown herein, or discontinue the product
at any time without notice or obligation.
Contact Mindray Representative for the
most current information
17
Mindray Confidential
Version 1.0