EPEVER
LS-E Series
     —— Solar Charge Controller
         USER
       MANUAL
LandStar
LS-E Series
           —— Solar Charge Controller
                            LS0512E/LS1012E    12VDC
 Nominal System Voltage
                            LS1024E/LS2024E   12/24VDC
   Maximum PV Input         LS0512E/LS1012E     30V
         Voltage            LS1024E/LS2024E     50V
                            LS0512E             5A
         Nominal
                            LS1012E/LS1024E     10A
 Charge/Discharge Current
                            LS2024E             20A
                              Contents
1 Important Safety Information ..........................................1
2 General Information........................................................2
3 Installation Instructions...................................................3
     3.1 Mounting ...............................................................3
     3.2 Wiring ...................................................................4
4 Operation ........................................................................5
     4.1 LED Indicators ......................................................5
     4.2 Setting Operation ...................................................7
5 Protection and Troubleshooting ......................................8
     5.1 Protection ..............................................................8
     5.2 Troubleshooting .....................................................9
6 Technical specifications ................................................11
1 Important Safety Information
 Read all of the instructions and cautions in the manual before
  beginning installation.
 There are no user serviceable parts inside the controller. Do not
  disassemble or attempt to repair it.
 Install external fuses/breakers as required.
 Disconnect the solar module and fuse/breakers near to battery before
  installing or adjusting the controller.
 Do not allow water to enter the controller.
 Confirm that power connections are tightened to avoid excessive
  heating from loose connection.
                                    1
2 General Information
LS-E series solar charge controller, with beautiful, economic, practical,
simple and easy to use, etc. It has various unique functions:
High efficient Series PWM charging, increase the battery lifetime
  and improve the solar system performance.
 Battery LED indicator can indicates battery situation.
Support 3 charging options: Sealed, Gel and Flooded.
Adopt       temperature compensation, correct the charging and
 discharging parameters automatically and improve the battery
 lifetime.
Electronic protection: load overload and short circuit, battery over
discharging, over voltage, low voltage and reverse protection.
With humanized Settings, operation will be more comfortable and co
nvenient.
 Industrial design, wide application range.
                                   2
3 Installation Instructions
3.1 Mounting
Read through the entire installation section first before beginning
  installation.
Be very careful when working with batteries. Wear eye protection.
  Have fresh water available to wash and clean any contact with
  battery acid.
Uses insulated tools and avoid placing metal objects near the
  batteries.
Explosive battery gasses may be present during charging. Be certain
  there is sufficient ventilation to release the gasses.
Avoid direct sunlight and do not install in locations where water can
  enter the controller.
Loose power connections and/or corroded wires may result in
  resistive connections that melt wire insulation, burn surrounding
  materials, or even cause fire. Ensure tight connections and use cable
  clamps to secure cables and prevent them from swaying in mobile
  applications.
Use with Gel, Sealed or Flooded batteries only.
Battery connection may be wired to one battery or a bank of batteries.
  The following instructions refer to a singular battery, but it is
  implied that the battery connection can be made to either one
  battery or a group of batteries in a battery bank.
 Select the system cables according to 3.5A/mm2 current density.
                                     3
3.2Wiring
1. Connect components to the charge controller in the sequence as
   shown in above picture and pay much attention to the “+” and
   “-”.Always power the battery First.
2. After power the battery, check the battery indicator on the
   controller, it will be green. If it’s not green, please refer to chapter
   5.
3. The load should be DC applicant with the same rated voltage as
   battery’s. Controller offers power to loads through the battery
   voltage.
                                    4
4 Operation
4.1 Features
              Load status indicator       LED2         LED4
 Charging status indicator            LED1      LED3
                                                                       Setting
                                                                       button
                                                                       Mounting
                                                                        Holes
             Solar Module Battery Load
             Terminals        Terminals Terminals
 Charging and load status indicator
                                                                     Table 4-1
                      Indicator     System
  Indicator                                                   Note
                        Status       Status
                         On       Charging         Normal
  Charging
  status               Fast            Over
                                                   Refer to section 5
  indicator          Flashing         voltage
                        On            Load ON
                                                   Normal
  Load status          OFF            Load OFF
  indicator           Slowly                   When the load amp is
                                      Overload
                     Flashing                  1.25times of rated
                                      5
                                                  current for 60 seconds,
                                                  or the load amp is 1.5
                                                  times of rated current for
                                                  5 seconds
                   Fast
                                   Short Circuit Refer to section 5
                   Flashing
Battery status indicator(LED1、LED2、LED3、LED4)
Battery LED indicator(The parameters in the table below is for 12VDC
system at 25℃, for 24VDC system ,the parameters is doubled)
                                                                  Table 4-2
    LED1           LED2       LED3       LED4            Battery Status
   Slowly
                   ×       ×          ×            Under voltage
  Flashing
     Fast
                   ×       ×          ×           Over discharged
  Flashing
          Battery LED indicator status during voltage is up
      ○               ○        ×         ×           12.8V< Ubat<13.4V
      ○               ○        ○         ×           13.4V< Ubat<14.1V
      ○               ○        ○         ○              14.1V < Ubat
          Battery LED indicator status during voltage is down
      ○               ○        ○         ×           12.8V<Ubat<13.4V
      ○               ○        ×         ×           12.4V<Ubat<12.8V
      ○               ×        ×         ×                Ubat<12.4V
“○”LED indicates on        “×”LED indicates off        “Ubat”battery voltage
                                     6
4.2 Setting Operation
 Load Work Mode Setting
When the controller is powered on, press the setting button to control
the load output. Press the button once, the ON/OFF status will be
changed corresponding.
 Battery Type Setting
Press the setting button for more than 5 seconds, battery indicator
LED1, LED2, LED3 will be flashing correspondingly. Then press the
setting button to choose Sealed, Gel, and Flooded battery type, when
you finish choosing, stop pressing the button, the setting is finished till
the digital tube stop flashing. The parameters indicated are shown
below:
         Battery type selection                           Table4-4
     LED1           LED2          LED3             Battery type
         ○            ×            ×       Sealed lead acid battery
         ○            ○            ×               Gel battery
         ○            ○            ○             Flooded battery
         “○”LED indicator on                   “×”LED indicator off
                                       7
5 Protection and Troubleshooting
5.1 Protection
·
Load Overload
If the load current exceeds 1.25 times of rated current for 60 seconds,
or the load amp is 1.5 times of rated current for 5 seconds, the
controller will disconnect the load. Overload must be cleared up
through powering on again or pressing the setting button.
·
Load Short Circuit
Fully protected from load wiring short circuit (exceeds 2 times of
rated current) automatically. One automatic load reconnect attempt,
the fault must be cleared by reapply power or pressing the setting
button.
·
Battery Reverse Polarity
Fully protection form battery reverse polarity, no damage to the
controller will result. Correct the mistake of wiring to resume normal
operation.
·
Damaged Local Temperature Sensor
If the temperature sensor short-circuited or damaged, the controller
will be charging or discharging at the default temperature 25℃ to
prevent the battery damaged from overcharging or over discharged.
                                   8
·
High Voltage Transients
PV is protected from high voltage transients. In lightning prone areas,
additional external suppression is recommended.
5.2 Troubleshooting
 Trouble Shooting                                               Table 5-1
                            Possible
      Faults                                        Troubleshooting
                            reasons
  Charging LED         PV                  Check if PV and battery wire
  indicator off        array               connections are correct and
  during daytime       disconnection       tight.
  when sunshine
  falls on PV
  modules
  properly.
  Charging LED         Battery voltage     Check if battery voltage is
  indicator     fast   higher       than   over high. Disconnect the
  flashing             over      voltage   solar module.
                       disconnect
                       voltage(OVD)
  Battery LED1         Battery             When load output is normal,
  indicator            under               LED status will return to ON
  SLOWLY               voltage             automatically when fully
  FLASHING                                 charged.
                                       9
Battery LED1        Battery               When the controller cut off
indicator           over                  the output automatically,
FAST                discharged            LED status will return to ON
FLASHING.                                 automatically when fully
                                          charged.
Load        LED     Over      load        Please reduce the load and
indicator                                 press the button once, the
SLOWLY                                    controller will resume to
FLASHING                                  work after 3s.
Load        LED     Short     circuit     When the first short-circuit
indicator                                 occurs, the controller will
FAST                                      automatically resume to work
FLASHING                                  after 10s; when a second
                                          short-circuit occurs, press the
                                          button, the controller will
                                          resume to work after 3s.
No          LED     battery voltage       Measure battery voltage with
indicator           lower than 6V         multi-meter. Min.6V can start
                                          up the controller.
No       charging   input voltage of      Measure the input voltage of
status      LED     solar     module      solar   module,      the    input
indicator with      lower        than     voltage must be higher than
normal              battery voltage       battery voltage.
connection
                                     10
6 Technical specifications
Electrical Parameters                                           Table 7-1
            Description                 Type                 Parameter
                                  LS0512E/LS1012E             12VDC
  Nominal System Voltage
                                  LS1024E/LS2024E            12/24VDC
  Max.batt.Volt.to the            LS0512E/LS101E               16V
  controller                      LS1024E/LS202E               32V
                                       LS0512E                  5A
  Rated Battery Current           LS1012E/LS102E               10A
                                       LS2024E                 20A
  Charge Circuit Voltage Drop           ALL                   ≤0.26V
  Discharge Circuit Voltage
                                        ALL                   ≤0.15V
  Drop
  Self-consumption                      ALL                    ≤6mA
Temperature Compensation Coefficient                             Table7-2
            Description                          Parameter
    Temperature Compensation
                                               -5mV/℃/2V (ref)
     Coefficient(TEMPCO)*
* Compensation of equalize, boost, float and low voltage disconnect
voltage
Environmental parameters                                        Table 7-3
  Environmental parameters                         Parameter
          Working temperature                    -35℃~+55℃
          Storage temperature                    -35℃~+80℃
               Humidity                           ≤95% N.C.
               Enclosure                             IP30
                                  11
(The parameters in the table below is for 12VDC system at 25℃, for 24VDC
system ,the parameters is doubled)
 Battery Voltage Parameters                                       Table 7-4
                              Charging     Parameters
  Battery charging setting            Sealed             Gel      Flooded
  Over Voltage Disconnect
                                          16V           16V        16V
  Voltage
  Charging Limit Voltage              15.5V             15.5V     15.5V
  Over Voltage Reconnect
                                          15V           15V        15V
  Voltage
  Equalize Charging Voltage           14.6V             -------   14.8V
  Boost Charging Voltage              14.4V             14.2V     14.6V
  Float Charging Voltage              13.8V             13.8V     13.8V
  Boost Reconnect Charging
                                      13.2V             13.2V     13.2V
  Voltage
  Low Voltage Reconnect
                                      12.6V             12.6V     12.6V
  Voltage
  Under Voltage Warning
                                      12.2V             12.2V     12.2V
  Reconnect Voltage
  Under Voltage Warning
                                          12V           12V        12V
  Voltage
  Low Voltage Disconnect
                                      11.1V             11.1V     11.1V
  Voltage
  Discharging Limit Voltage           10.5V             10.5V     10.5V
  Equalize Duration                  2 hours            -------   2 hours
  Boost Duration                     2 hours        2 hours       2 hours
                                     12
Mechanical Parameters                                Table 7-5
           Type               LS0512E          LS1012E
    Overall Dimension     92.8x65x20.2mm   101.2x67x21.8mm
   Mounting dimension         84.4mm            92.7mm
    Mounting hole size         Φ4.5              Φ4.5
         Terminal             2.5mm²            4mm²
          Weight                74g             82.5g
Mechanical Parameters                                  Table 7-6
          Type              LS1024E           LS2024E
    Overall Dimension    101.2x67x21.8mm   128x85.6x34.8mm
   Mounting dimension        92.7mm            118mm
    Mounting hole size        Φ4.5              Φ4.5
        Terminal              4mm²             6mm²
         Weight                82g             151.6g
                              13
Final interpretation right of the manual belongs to our company.
               Any changes without prior notice!
                                           Version number: V1.7
BEIJING EPSOLAR TECHNOLOGY CO., LTD.
Tel:+86-10-82894112 / 82894962
Fax:+86-10-82894882
E-mail:info@epsolarpv.com
Website: http://www.epsolarpv.com