Instrumentation Cable EN 50288-7: Flame Retardant, Sunlight Resistant 90 °C / 500 V

Uploaded by

Shashank Saxena
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
272 views4 pages

Instrumentation Cable EN 50288-7: Flame Retardant, Sunlight Resistant 90 °C / 500 V

Uploaded by

Shashank Saxena
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Instrumentation Cable EN 50288-7

Flame Retardant, Sunlight Resistant 90 °C / 500 V


Single & Multi-Pair, XLPE-Insulation, Collective Screen, PVC-Sheath

ICON BASE 10100 M1 OS


Application
For transmission of analogue and digital signals in instrument and control systems; allowed for use in zone 1 and zone 2 group II classified areas (IEC
60079-14); not allowed for direct connection to low impedance source, e.g. the public mains electricity supply. (Please note possible additional or special
installation requirements of IEC 60079-14).
Recommended for indoor and outdoor installation, on racks, trays, in conduits, in dry and wet locations; not for direct burial. Indoor installations are
allowed in areas, where the construction products regulation (CPR) acc. to EN 50575 of fire class is not required. (Please note the relevant legal / local
installation requirements)
Construction
Conductor 2 2
plain annealed copper wire, stranded, size: 0,5 mm , 0,75 mm , 1,0 mm ,
2

................................................. 1,3 mm2, 1,5 mm2, 2,5 mm2


Insulation cross-linked polyethylene XLPE
.................................................
Colour black / white, continuously numbered on white core (1, 2, 3..) for multi-ele-
................................................. ment
Wrapping at least 1 layer of plastic tape
.................................................
Collective aluminium polyester foil in contact with stranded tinned copper drain wire
.................................................
Outer polyvinyl chloride PVC, black, blue for intrinsically safe systems
.................................................
Cable LEONI KERPEN ICON BASE Type Code Size 500V RP EN 50288-7 Pro-
................................................. duction Lot Code Year Length Marking
Technical data Abbreviations
Flame propagation Temperature range ICON BASE
- Test on single cable IEC 60332-1-2 -30°C up to +90°C OS overall screen
- Test on bunched cables IEC 60332-3-24 (Cat. C) (during operation)
-5°C up to +50°C
Limiting Oxygen Index (LOI) ASTM D 2863 (min. 30 %)
(during installation)
Flammability temperature (FT) ISO 4589-3 ann. A (min. +250 ° C)
Minimum bending radius
Amount of halogen acid gas IEC 60754-1 (max. 23 %)
7,5 x cable diameter
Oil resistance ICEA S-73-532
Sunlight resistance UL 1581 section 1200

Technical datasheet © LEONI Kerpen GmbH · Phone: +49 24 02 17 1 · www.leoni-process-industry.com/en/


Print date: 31.07.2020 Transfer to third parties only by authority of LEONI Kerpen GmbH Creator: TF/MY
Date of version: 27.07.2020 Printing errors excepted. Subject to alterations. Image serves as an example. Page: 1/4
For cable disposal please note the relevant local legal disposal requirements.
7E12010000_EN_50288-7_500_ICON_BASE_10100_M1_OS_black_stranded_Pair_en.pdf
Instrumentation Cable EN 50288-7

Flame Retardant, Sunlight Resistant 90 °C / 500 V


Single & Multi-Pair, XLPE-Insulation, Collective Screen, PVC-Sheath

ICON BASE 10100 M1 OS


Electrical Properties at 20 °C
Conductor nom. mm
2 0,5 0,75 1,0 1,3 1,5 2,5
cross-section
Conductor max. Ω/km 36,7 25,0 18,5 14,2 12,3 7,6
resistance
Insulation min. MΩ x km 5000
resistance
Mutual max. nF/km 150 150 150 150 150 150
capacitance
Inductance max. mH/km 1
Capacitance max. pF/500 m 500
unbalance
L/R ratio max. µH/Ω 25 40 60
Test voltage V 2000
Urms (core :
core)
Test voltage V 2000
Urms (core :
screen)
Operating V 500
voltage

Technical datasheet © LEONI Kerpen GmbH · Phone: +49 24 02 17 1 · www.leoni-process-industry.com/en/


Print date: 31.07.2020 Transfer to third parties only by authority of LEONI Kerpen GmbH Creator: TF/MY
Date of version: 27.07.2020 Printing errors excepted. Subject to alterations. Image serves as an example. Page: 2/4
For cable disposal please note the relevant local legal disposal requirements.
7E12010000_EN_50288-7_500_ICON_BASE_10100_M1_OS_black_stranded_Pair_en.pdf
Instrumentation Cable EN 50288-7

Flame Retardant, Sunlight Resistant 90 °C / 500 V


Single & Multi-Pair, XLPE-Insulation, Collective Screen, PVC-Sheath

ICON BASE 10100 M1 OS


Geometrical data
No. of elements RT of insulation RT of outer sheath Outer dia. Weight Part No.
min. nom. approx. approx. Colour
mm mm mm kg/km black
2
0,5 mm /7
1 0,44 0,9 6,2 44 LKX7128F0010000
2 0,44 1,0 9,2 80 LKX7128F0040000
4 0,44 1,0 10,6 110 LKX7128F0070000
5 0,44 1,0 11,2 126 LKX7128F1510000
6 0,44 1,1 12,9 164 LKX7128F0100000
8 0,44 1,2 13,9 196 LKX7128F0130000
10 0,44 1,2 15,7 239 LKX7128F0160000
12 0,44 1,3 16,6 281 LKX7128F0190000
16 0,44 1,2 18,5 351 LKX7128F0220000
20 0,44 1,3 19,7 403 LKX7128F0250000
24 0,44 1,5 22,7 520 LKX7128F0280000
2
0,75 mm /7
1 0,44 0,9 6,5 50 LKX7128F0310000
2 0,44 1,0 9,8 93 LKX7128F0340000
4 0,44 1,1 11,6 138 LKX7128F0370000
5 0,44 1,1 12,2 160 LKX7128F1540000
6 0,44 1,2 14,0 204 LKX7128F0400000
8 0,44 1,2 14,9 241 LKX7128F0430000
10 0,44 1,3 17,0 301 LKX7128F0460000
12 0,44 1,3 17,8 351 LKX7128F0490000
16 0,44 1,4 20,3 460 LKX7128F0520000
20 0,44 1,5 22,6 559 LKX7128F0550000
24 0,44 1,6 24,6 665 LKX7128F0580000
2
1,0 mm /7
1 0,44 0,9 6,9 59 LKX7128F0610000
2 0,44 1,0 10,4 111 LKX7128F0640000
4 0,44 1,0 12,1 159 LKX7128F0670000
5 0,44 1,1 13,5 201 LKX7128F1570000
6 0,44 1,1 14,7 237 LKX7128F0700000
8 0,44 1,2 15,8 289 LKX7128F0730000
10 0,44 1,2 18,0 357 LKX7128F0760000
12 0,44 1,3 19,0 421 LKX7128F0790000
16 0,44 1,3 21,5 547 LKX7128F0820000
20 0,44 1,4 23,9 664 LKX7128F0850000
24 0,44 1,5 26,1 800 LKX7128F0880000
2
1,3 mm /7
1 0,44 0,9 7,4 67 LKX7128F0910000
2 0,44 1,1 11,6 135 LKX7128F0940000
4 0,44 1,2 13,6 204 LKX7128F0970000
5 0,44 1,2 15,0 250 LKX7128F1600000
6 0,44 1,3 16,5 301 LKX7128F1000000

Technical datasheet © LEONI Kerpen GmbH · Phone: +49 24 02 17 1 · www.leoni-process-industry.com/en/


Print date: 31.07.2020 Transfer to third parties only by authority of LEONI Kerpen GmbH Creator: TF/MY
Date of version: 27.07.2020 Printing errors excepted. Subject to alterations. Image serves as an example. Page: 3/4
For cable disposal please note the relevant local legal disposal requirements.
7E12010000_EN_50288-7_500_ICON_BASE_10100_M1_OS_black_stranded_Pair_en.pdf
Instrumentation Cable EN 50288-7

Flame Retardant, Sunlight Resistant 90 °C / 500 V


Single & Multi-Pair, XLPE-Insulation, Collective Screen, PVC-Sheath

ICON BASE 10100 M1 OS


Geometrical data
No. of elements RT of insulation RT of outer sheath Outer dia. Weight Part No.
min. nom. approx. approx. Colour
mm mm mm kg/km black
8 0,44 1,3 17,6 363 LKX7128F1030000
10 0,44 1,4 20,2 456 LKX7128F1060000
12 0,44 1,4 21,1 529 LKX7128F1090000
16 0,44 1,5 24,1 698 LKX7128F1120000
20 0,44 1,5 25,7 800 LKX7128F1150000
24 0,44 1,6 28,0 951 LKX7128F1180000
2
1,5 mm /7
1 0,44 0,9 7,5 70 LKX7128F1210000
2 0,44 1,1 12,0 149 LKX7128F1240000
4 0,44 1,2 14,1 225 LKX7128F1270000
5 0,44 1,2 15,5 277 LKX7128F1630000
6 0,44 1,3 17,1 335 LKX7128F1300000
8 0,44 1,2 18,0 396 LKX7128F1330000
10 0,44 1,4 21,0 511 LKX7128F1360000
12 0,44 1,5 22,1 602 LKX7128F1390000
16 0,44 1,4 24,9 775 LKX7128F1420000
20 0,44 1,5 26,8 883 LKX7128F1450000
24 0,44 1,6 29,2 1083 LKX7128F1480000
2
2,5 mm /7
1 0,53 0,9 8,6 95 LKX7128F9550000
2 0,53 1,1 13,6 192 LKX7128F9560000
4 0,53 1,2 16,1 307 LKX7128F9570000
5 0,53 1,2 17,7 379 LKX7128F9580000
6 0,53 1,3 19,6 454 LKX7128F9590000
8 0,53 1,4 21,1 576 LKX7128F9600000
10 0,53 1,5 24,2 735 LKX7128F9610000
12 0,53 1,5 25,4 839 LKX7128F9620000
16 0,53 1,6 29,0 1111 LKX7128F9630000
20 0,53 1,7 32,2 1348 LKX7128F9640000
24 0,53 1,8 35,1 1597 LKX7128F9650000
RT = Radial Thickness

Technical datasheet © LEONI Kerpen GmbH · Phone: +49 24 02 17 1 · www.leoni-process-industry.com/en/


Print date: 31.07.2020 Transfer to third parties only by authority of LEONI Kerpen GmbH Creator: TF/MY
Date of version: 27.07.2020 Printing errors excepted. Subject to alterations. Image serves as an example. Page: 4/4
For cable disposal please note the relevant local legal disposal requirements.
7E12010000_EN_50288-7_500_ICON_BASE_10100_M1_OS_black_stranded_Pair_en.pdf

You might also like