Ultrasonic Transducers Date: 7/26/05
Dimensions: mm (In.)
Part Number:
255-400ET18 255-400ER18
17.50
Aluminum (.689)
Case
10±.304
ø18 (.394±.012)
(ø.709)
Diaphragm ø1.19x2
13.48 (ø.047x.079)
(.531)
Ultrasonic Transducers Page 1 of 2
Transmitter
Directivity 0º
330º 30º
300º 60º
270º -40º 90º
-30º
240º -20º 120º
-10º
210º -0º 150º
180º
KT-400049
Electrical Specifications: Mechanical Specifications:
• Center frequency (f0): 40.0KHz ± 1.0KHz • Type: Transmitter: 255-400ET18
• SPL @ f0: 115dB (0dB re 0.0002 µ bar) Receiver: 255-400ER18
• Sensitivity @ f0: -70dB (0dB = 1V/µ bar) • Operating temperature: -30°C ~ +80°C
• Bandwidth: 1.5KHz (-6dB) • Storage temperature: -40°C ~ +100°C
• Capacitance @ 1KHz: 2,600pF ± 20%
• Allowable input power: 0.2W
Material:
• Input voltage: 20V max.
• Water Resistant
Available from Mouser Electronics www.mouser.com (800) 346-6873
Specifications are subject to change without notice. No liability or warranty implied by this information. Environmental compliance based on producer documentation.
Ultrasonic Transducers Date: 7/26/05
Part Number:
255-400ET18 255-400ER18
Sensitivity (255-400ER18)
-50
-60
-70
dB
-80
Ultrasonic Transducers (Page 2 of 2
-90
-100
35 36 37 38 39 40 41 42 43 44 45
KHz
Sound Pressure Level (255-400ET18)
130
120
110
dB
100
90
80
35 36 37 38 39 40 41 42 43 44 45
KHz
Impedance & Phase Angle vs. Frequency
1E+05 90
45
1E+04
Ohm 0
1E+03
-45
1E+02 -90
35 36 37 38 39 40 41 42 43 44 45
KHz
Available from Mouser Electronics www.mouser.com (800) 346-6873
Specifications are subject to change without notice. No liability or warranty implied by this information. Environmental compliance based on producer documentation.