PROJECT : PAGE :
CLIENT : DESIGN BY :
JOB NO. : DATE: REVIEW BY :
Wind Girt Deflection Analysis of Wood, Metal Stud, and/or Steel Tube
INPUT DATA & ANALYSIS RESULTS
DIMENSIONS
L= 12 ft
H1 = 4 ft
H2 = 6 ft
H3 = ft 8
GIRT SECTIONS
LINTEL = 6 x 8 - Douglas Fir-Larch No. 1
SILL = (2) - 2 x 6 - No. 1
JAMB = HSS6X2X1/4
WIND LOAD
I= 1 (ASCE 7-05 Tab 6-1)
EXPOSURE = C
MEAN ROOF HEIGHT = 36 ft, (ASCE 7-05 Tab 6-3)
V= 90 mph, (IBC 06 Tab 1609.3.1)
BUILDING CORNER ? Yes (Zone 5, ASCE 7-05 Fig 6-11& 6-17)
THE DESIGN IS ADEQUATE.
DEFLECTION LIMITATION (IBC 06 Tab 1604.3) L / 240
ANALYSIS
OUT-OF-PLANE WIND FORCE (ASCE 7-05, Eq.6-22)
p q h G C P G C Pi 0.00256 K h K Zt K dV 2I G C P G C Pi = 22.4 psf USE 16 psf
(IBC 06 Table 1604.3 note: f )
Where Kh = 1.02 , (ASCE Tab. 6-3)
Kd = 0.85 , (ASCE Tab. 6-4)
Effective Area = 84.00 ft2, (ASCE Fig. 6-11A or 6-17)
GCp = -1.07 , (ASCE Fig. 6-11A or 6-17)
GCpi = 0.18 , (ASCE Fig. 6-5)
KZt = 1 Flat, (ASCE 6.5.7.2)
CHECK LINTEL DEFLECTION
5wL4
0.31 in < L / 240 = 0.60 in [Satisfactory]
384 EI
Where w = 0.11 kips / ft
E = 1600 ksi
I = 104 in4
CHECK SILL DEFLECTION
5wL4
0.53 in < L / 240 = 0.60 in [Satisfactory]
384 EI
Where w = 0.08 kips / ft
E = 1700 ksi
I = 42 in4
CHECK JAMB DEFLECTION
D max = 0.53 in, at 9.00 ft from top, < H / 240 = 0.90 in [Satisfactory]
Where Rlintel = 0.67 kips
Rsill = 0.48 kips
E = 29000 ksi
I = 13 in4
NOTE : Since girt size controlled by deflection, not by capacity, the wind coefficient w, 1.3, does not apply. (IBC 06 Section 1605.3.2)