SOLENOID OPERATED VALVES
Continuous Duty Coils-ED 100%
 Ordering Code:                  EC-04W-X-Y-Z
                                     48
             36                            21.5               3
                                                                                   TECHNICAL DATA
                                     26                                Weight:                     0.22 kg
                                    26                                 HEAT INSULATION CLASS H:
                                   12.7                                    356℉             (180℃)
                                                                       Ambient temperature range:
                                                                         -22+140℉        (-30+60℃)
                                                                       Available on request:
        38.5
               36.1
                                                                       Different Voltages -
                                                                       Different connectors.
                                                                       Inlet voltage fluctuations must not
                                                                       exceed ± 10﹪of nominal voltage to
                                                                       obtain correct operation and long
                           While installing, please be sure
                                                                       life of coils.
                           that this side is toward to
UNIT:mm                    the solenoid cartridge valve.               CE approved
  X                            Power (W)                           Y                 Connections
200              20 Watt.                                          H   DIN43650-ISO4400
               Voltage (V)                    Resistance (Ω)                 Current (A)
  Z
                  Nominal                       20~25 C                Cold Coil      Hot Coil
 C                    24V RAC                     23.2±7﹪                 0.95            0.63
 B                    110V RAC                     470±7﹪                 0.19            0.14
 A                    220V RAC                    1910±7﹪                 0.09            0.07
 F                    10V DC                       5.0±8﹪                 1.98            1.28
 E                    12V DC                        7.5±7﹪                1.66            1.06
 M                    14V DC                       9.3±7﹪                 1.48            0.96
 N                    20V DC                         20±7﹪                0.99            0.65
 D                    24V DC                      28.6±7﹪                 0.88            0.53
 G                    26V DC                      34.2±7﹪                 0.77            0.52
 J                    28V DC                      39.2±7﹪                 0.71            0.50
 L                    36V DC                        64±7﹪                 0.56            0.36
 H                    48V DC                       110±7﹪                 0.45            0.28
Rev.160930                                                                                             H.101.300