FOUNDATIONS
P2 P3 P2
C4
P3 P3
P3
P2 P2 P2
P2 P2 P2
P2
P2 P2
*M-20 & FE 500D
* SAFE LOAD ON SINGLE PILE 30 T
6-#16
125 C/C
1.125
1.725
2-#10 0.750
6-#16
0.700
P2
300
FOR PILE CAP-P2
GRADE 16 # @ 150 C/C
1.725
2.555 BEAM BOTHWAYS
0.150 0.150
3 1.880
1.125 3
G.L. 8 # 4 LEGD STPS/MTR
0.525
.300 0.850@ 250 C/C
1.0
10 # 3 NOS.
500
0.867
all round the cap
1.300
75 MM TH.PCC 1:3:6 #16@
16
20 ## @ 150
@ 125
150 C/C
C/C
100 MM TH.SAND FILLING
BOTHWAYS
BOTHWAYS
0.600
0.675
PILE CAP - P3 SECTION:3-3
FOR PILE CAP-P3
Column Details
C3 C4 C3
C2 C4 C2
C1 C1 C1
C1 C1 C1
C1 C1 C1
C1-250X375- 8-#12
#8@150 C/C
C2-250X375-
4-#16+4-#12
#8@150 C/C
C4-250X375-
C3-250X375- 8-#16
4-#20+4-#16
#8@150 C/C
#8@150 C/C
PLINTH BEAM DETAILS
PB2 PB2
PB3
PB3
PB2
PB2
PB2
PB4 PB4
PB1 PB1
PB2
PB2
PB1 PB1 PB2
PB3
PB3
PB3
PB3
PB1 PB4
PB3
PB3
PB3
PB1
PB4
PLINTH BEAMS
2-T12+1-T16 2-T12+1-T16 2-T12+3-T16
2-T12
3-T16 3-T16
3-T12 3-T12
CENTER SUPPORT
CENTER SUPPORT
#8@125 C/C #8@75C/C
#8@150 C/C #8@125 C/C
PB2-250X375
PB1-250X350
2-T12 3-T12 3-T12 5-T12
3-T12 5-T12 3-T12
3-T12
CENTER SUPPORT CENTER SUPPORT
#8@150 C/C #8@150C/C #8@150 C/C #8@125 C/C
PB3-250X300 PB4-250X350
P2