0% found this document useful (0 votes)
275 views3 pages

H 9

inert gas manual - 1

Uploaded by

Nestor Mospan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
275 views3 pages

H 9

inert gas manual - 1

Uploaded by

Nestor Mospan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 3
53.2 533 534 Inert Gas Generator KANGRIM Every 250 hrs (Component Mainterance Description [Remarks Pilot burner Dismount and clean oil nozzle Distance between electrodes Part No. 0870 [Check and clean spark plug lapprox. 3~4 mm. Main burner Dismount and clean oil nozzle Part No. 0860 Check cone damage [Fuel oil filter Drain sump Fuel off filter manual IPart No. 6010 Tnstrument air filter Disassemble and efean [Part No. 2620 Filter of pressure regulators Part No. 0023, 0063, (Clean filter element Annually [Component “Mainterance Description [Remarks [Demister [Clean it [Part No. 1300, 1310, 1320 [Water spray nozzles inspect and clean IFnecessary Part No. 1170 [Temperature & pressure Check the calibration leauges PLC battery Replace battery See replacing the PLC battery PLC manual Safety devices [Clean filter element See the settings in the part lists After every stop (Component Mainterance Description [Remarks [Compbusion chamber cooling jacket [Rinse with fresh water [DO NOT USE SALT WATER| Replacing the PLC battery The PLC is almost maintenance free. There are only a few points for maintenance. ‘The battery must be replaced every year. When the battery is not inserted, (or inserted in the correct manner), the PLC will not work properly. Make sure there is always a spare battery on board the ship for each CPU unit. Replacement of the battery: 1. Make sure the power on the PLC is turned on (green or red light on), 2. Switch the RUN/STOP switch in position STOP, the red light will light up. 3. Pull the battery cover open and remove the battery by pulling the plastic strip, the yellow light with light up. 4, Put the new battery in its place. Check the polarity. 5. The yellow light will go out. If not, the battery is defective or has been inserted incorrectly. 6. If the yellow light is out, switch the PLC to run mode. The red light will go out and the green light will light up. KANGRIM INDUSTRIES CO., LTD. 45 5.3.6 Lubricating Inert Gas Generator schedule KaANGRIM For lubricating instructions of the E-motors, consult the instructions in the Sub-suppliers documentati [interval Driven end Every 800 hrs [Non driven end Every 800 hrs [Component [E-motors, Part No. 10307 1040 [E-motors, Part No. 1030 7 1040 oy [See Motor L.O. chart [See Motor L.O. Bearing type [See Motor technical table Lubricant [See Motor L.O. chart Reference [Sub-suppliers documentation * Remark : If grease of another maker will be used it is recommended to remove the consisting grease completely from the bearing(s) before the new grease is used. KANGRIM INDUSTRIES CO., LTD. 46 Inert Gas Generator KANGRIM 6. Some possible causes to faults during start and operation KANGRIM INDUSTRIES CO.,LTD.

You might also like