Data Sheet IMHNP075EN

NEW: HNP075 Series Oil Purifier


For fluid viscosities to 700 cSt

Water in hydraulic, lubrication, power


transmission and insulating fluids adversely
affects fluid performance and is a threat
to system reliability.
Water contamination promotes corrosion and fluid system
component wear, resulting in reduced component life and
increased maintenance costs. It also degrades fluid
properties, leading to reduced lubricity and load carrying
ability, oil oxidation and the resultant formation of acids,
and additive precipitation. The consequences are reduced
fluid service life, increased fluid procurement and
disposal costs.
The ‘Pall’ HNP075 Series Oil purifier is designed for use
with medium to large oil systems, particularly where high
viscosity fluids are employed.
The Pall HNP fluid conditioning purifier uses vacuum
dehydration to remove 100 % free water and as much as
90 % of dissolved water. It will also remove 100 % of free
and entrained gases and up to 80 % dissolved gases.
HNP075 Series (mobile) Oil Purifier
Vacuum dehydration is the most effective method of water
removal at minimum cost and ease of use. Unlike other Select the HNP075 oil purifier for:
methods it removes both free and dissolved water and • High performance water, gas and particulate removal
cannot burn or otherwise significantly alter the properties
• Extension of fluid service life
of the oil.
• Minimized corrosion within systems
Particulate contaminant removal is achieved using high
performance rated Ultipleat® SRT filter elements. • Reduced fluid disposal

In addition, a water sensor measures water content and • Reduced operating costs
temperature at the purifier inlet, allowing the • Increased equipment reliability
purifier to operate only when the water content rises • Simple automated operation
above a pre-determined level. • Remote monitoring option
Removing free water is never enough!
1 Initial water content is above saturation
1 Typical Oil
(free water).
Saturation
Curve 2 Maximum water removal capability of
Water Content (PPM)

“free water removal” devices (coalescers,


centrifuges, etc.) is to the oil’s saturation point.
5 2 3 Water content achieved with mass transfer
dehydration is significantly below the oil’s
Oil Saturation
Oil Saturation saturation point.
Point at Initial
Point after Cooler Temperature 4 Water content achieved with mass transfer
dehydration remains below the oil’s saturation
point even after oil is cooled by the system
heat exchanger. This prevents the formation
4 3 of free water which is detrimental to fluid
system components and the fluid.
5 If only free water is removed at initial
Oil Temperature temperature, when oil is cooled the
Temperature Initial Oil
amount of free water in the oil
after Cooler Temperature
can increase significantly.
Specifications Ordering Information
Dimensions (max): 725 x 1585 x 1820 mm
(28.5" x 62.4" x 71.7") Purifier P/N: HNP075 1 3 2 3 4 5 6
Dry mass: 385 kg (849 lbs) approx
Inlet connections: 2" BSPP or 2" NPT Table 1 - Standard Voltage/Frequency Options
Outlet connections: 1½" BSPP or 1½" NPT Code Voltage Frequency
Flow rate: 71 L/min (21.8 USgpm) R 380 VAC 50 Hz, 3 phase

Inlet pressure: 1.5 bar g S 400 VAC 50 Hz, 3 phase

(150 kPag / 44 psig) maximum


System back pressure: 3.5 bar g Table 2 - Seal Type Table 5 - Language Options
(350 kPag / 50.8 psig) maximum Code Material Code Language
Fluid operating H Nitrile and Fluorocarbon DE German
temperature: +10ºC to +70ºC (50°F to 158°F) Z Fluorocarbon EN English
Fluid viscosity: 700 cSt (3300 SUS) maximum ES Spanish
Operating vacuum: -0.6 to -0.9 barg (adjustable) Table 3 - Mounting Options FI Finnish
(-60 kPag / -8.7 psi g to FR French
-90 kPag / -13.1 psi g) Code Mounting Type
IT Italian
Power supply: See Table 1 of Purifier P/N C
Mobile (2 fixed and
NL Dutch
2 swivel castors)
Total Motor power: 6.4 kW PL Polish
N Static (skid mounted)
RU Russian
Materials of Construction SV Swedish
Table 4 - Process Port
Base frame: Epoxy painted carbon steel Connection Options Table 6 - Optional Factory
Vacuum vessel: 304 Stainless Steel 2" Inlet / 1½ Outlet Fitted Kits
Fittings & fasteners: Corrosion protected carbon steel Code
Connections Code Kit
Control box: Epoxy painted carbon steel P BSP ISO 228 threads A No optional kit(s) fitted
Hydraulic Hoses: AQP Elastomer Tube T NPT SAE threads B Electrical Connection Kit

Note: Pall HNP075 series fluid conditioning purifiers comply with all applicable
EC directives and bear the CE mark.
Optional inlet & outlet hose 5m P/N: HNP075HZ
Fig. 1 Typical static option

Element P/N: UE 619 1 40Z


Note: Z indicates fluorocarbon seals are standard.
Other options are available; contact Pall.
1820mm (71.7in) - mobile option
1695mm (66.7in) - static option

Table 1 - Element Rating


Code ßx(c) ≥1000 based on ISO 16889
AZ 3
Fluid Inlet AP 5
AN 7
AS 12

Fluid Outlet
AT 22

Replacement Air Breather P/N: HC0293SEE5


720mm
1580mm
28.35in
62.2in

25 Harbor Park Drive Visit us on the Web at www.pall.com


Port Washington, NY 11050
Pall Corporation has offices and plants throughout the world. For Pall representatives in your
+1 516 484 3600 telephone area, please go to www.pall.com/contact
+1 888 333 7255 toll free US
Because of technological developments related to the products, systems, and/or services
Portsmouth - UK described herein, the data and procedures are subject to change without notice. Please
consult your Pall representative or visit www.pall.com to verify that this information remains
+44 (0)23 9230 3303 telephone valid. Products in this document may be covered by one or more of the following patent
+44 (0)23 9230 2507 fax numbers: EP 667,800; EP 982,061; EP 1,380,331; US 5,543,047; US 5,690,765; US 5,725,784;
US 6,113,784; US 7,083,564; US 7,318,800.
© Copyright 2012, Pall Corporation. Pall, , and Ultipleat are trademarks of Pall Corporation.
® Indicates a trademark registered in the USA. ENABLING A GREENER FUTURE and
Filtration. Separation. Solution.SM are service marks of Pall Corporation.
*AQP Elastomer Tube is a trademark of Aeroquip® Corporation.

IMHNP075EN Produced in the UK. January 2012