CNT-300

CNT-300, CNT® 50 Ohm Braided Coaxial Cable, black PE jacket

Product Classification
Product Type Braided coaxial cable

Product Brand CNT®

Product Series CNT-300

General Specifications
Braid Coverage 87 %

Cable Type CNT-300

Jacket Color Black

Dimensions
Diameter Over Dielectric 4.83 mm   |   0.19 in

Diameter Over Jacket 7.62 mm   |   0.3 in

Diameter Over Tape 5.003 mm   |   0.197 in

Inner Conductor OD 1.78 mm   |   0.07 in

Outer Conductor OD 5.66 mm   |   0.223 in

Nominal Size 0.300 in

Electrical Specifications
Cable Impedance 50 ohm

Capacitance 80.4 pF/m   |   24.506 pF/ft

dc Resistance, Inner Conductor 6.96 ohms/km   |   2.121 ohms/kft

dc Resistance, Outer Conductor 8.5 ohms/km   |   2.591 ohms/kft

dc Test Voltage 2500 V

Jacket Spark Test Voltage (rms) 3500 V

Maximum Frequency 24.5 GHz


Page 1 of 3

©2020 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: January 15, 2020
CNT-300
Operating Frequency Band 30 – 6000 MHz

Peak Power 10 kW

Shielding Effectiveness 90 dB

Velocity 83 %

Attenuation
Frequency (MHz) Attenuation (dB/100 m) Attenuation (dB/100 ft)
30.0 3.8 1.16
50.0 4.9 1.5
150.0 7.9 2.4
220.0 9.5 2.9
450.0 13.1 4
900.0 19.4 5.9
1500.0 25.3 7.7
1800.0 28.2 8.6
2000.0 29.8 9.1
2500.0 33.8 10.3
3000.0 37.4 11.4
4000.0 44.61 13.6
4500.0 47.75 14.55
5000.0 50.52 15.4
5200.0 51.83 15.8
5500.0 53.14 16.2
5800.0 54.78 16.7
6000.0 55.8 17

Material Specifications
Braid Material Tinned copper

Dielectric Material Foam PE

Jacket Material PE

Inner Conductor Material Copper

Shield Tape Material Aluminum

Mechanical Specifications
Minimum Bend Radius, single Bend 0.88 in   |   22.352 mm

Tensile Strength 55 kg   |   121.254 lb


Page 2 of 3

©2020 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: January 15, 2020
CNT-300
Bending Moment 0.5 N-m   |   4.425 in lb

Flat Plate Crush Strength 0.5 kg/mm   |   27.999 lb/in

Environmental Specifications
Installation temperature -40 °C to +85 °C (-40 °F to +185 °F)

Operating Temperature -40 °C to +85 °C (-40 °F to +185 °F)

Storage Temperature -70 °C to +85 °C (-94 °F to +185 °F)

Packaging and Weights


Cable weight 0.06 kg/m   |   0.434 lb/ft

Packaging Type Reel

Regulatory Compliance/Certifications
Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system

Page 3 of 3

©2020 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: January 15, 2020