0% found this document useful (0 votes)
56 views1 page

Submersible Pump Cable Specs

The document describes CLEAN CABLE round cables that are used for submersible pump motors. The cables can be installed at depths of up to 250 meters in both dirty and drinking waters. They have bare copper conductors and insulation made of XLPE or PVC. The cables are approved for use in applications requiring ACS, KTW, WRAS, and D.M.174 compliance.

Uploaded by

Alex Khobta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views1 page

Submersible Pump Cable Specs

The document describes CLEAN CABLE round cables that are used for submersible pump motors. The cables can be installed at depths of up to 250 meters in both dirty and drinking waters. They have bare copper conductors and insulation made of XLPE or PVC. The cables are approved for use in applications requiring ACS, KTW, WRAS, and D.M.174 compliance.

Uploaded by

Alex Khobta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

CLEAN CABLE

Round cables for submersible pumps

CLEAN CABLE 4G1.5

Technical data CLEAN CABLE -

1 .
, CEI Bare copper complying with
EN 60228 (CEI 20-29) CEI EN 60228 (CEI 20-29) 250 , ,
Conductor
5 class 5 .
: ACS, KTW, WRAS, D.M.174.

2 XLPE or PVC. Coloured cores


(XLPE) . according to HD 308 Family cables CLEAN CABLE are round
Insulation and core HD (UNEL 00722) cables devoted for submersible pump motor
identification 308 (UNEL 00722) feeders. It may be installed for depthness
down to 250 m about, both in dirty waters
3 and drinking waters.
. Cross-linked rubber. Approvals: ACS, KTW, WRAS, D.M.174.
Jacket RAL 5015 Colour blue RAL 5015

450/750 450/750V PVC


Operating voltage 0,6/1 XLPE 0,6/1KV XLPE

2500 2500 V PVC


Test voltage 4000 XLPE 4000 V XLPE
• Submersible pump cables

> 20 MΩ· PVC > 20 MΩ·km PVC


Insulation resistance > 200 MΩ· XLPE > 200 MΩ·km XLPE

Fixed application
-40 ÷ 90 °C XLPE -40 ÷ 90 °C XLPE
-30 ÷ 70 °C -30 ÷ 70 °C PVC
Operating temperature
-25 ÷ 90 °C XLPE Flexible application
-5 ÷ 70 °C -25 ÷ 90 °C XLPE
-5 ÷ 70 °C PVC

5x 5 x outer diameter
Minimum bending radius

0,5% IEC 60754, CEI ≤ 0,5% IEC 60754, CEI EN


EN 50267-2 50267-2 Rubber
Halogen gas emission 18% IEC 60754, CEI EN ≤ 18% IEC 60754, CEI EN
50267-2 50267-2 PVC