1) This certificate documents the calibration of a pressure gauge for Omera Cylinders Limited. 2) The pressure gauge was calibrated against laboratory reference standards traceable to international standards. 3) The calibration results showed the pressure gauge measurements were within tolerance, taking into account the measurement uncertainties.

Uploaded by

Islam Sahafayat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
212 views3 pages

Ots Calibration

1) This certificate documents the calibration of a pressure gauge for Omera Cylinders Limited. 2) The pressure gauge was calibrated against laboratory reference standards traceable to international standards. 3) The calibration results showed the pressure gauge measurements were within tolerance, taking into account the measurement uncertainties.

Uploaded by

Islam Sahafayat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

_-)TS tgll

when accuracy matters.. ml


@ 0059

CERTI FICATE of CALI BRATION


rssued by OTS (Pvt.l Limited
Navana DH Tcwer, Level3,6 Panthapath, Dhaka-1215
Tel: +88-02-9126028, 9124003, 01755585553-7
Fax: +88 02 58156739, E-mail: info@otsbd.com, www.otsbd.com
cerhficat. No. c-0s02 & c.1352

certificateNo. o17ll17-o6114443a
lssu€ Date ra/o612o17

customer Details:

Na ma Omera Cylinders Limited


Mirpur, Natunbazar, Post Office: Shatiajuri,
Upazilar Bahubal, Zila: Habiganj,
Eangladesh.

Tel +8801787 671882, +8801787 671883


E-mail shawki jamal@omeracylinders.com, samiul.allm@omeracylinders.com

Details of Unit Under Calibration (UUC):

Description Pressure Gauge


MAG
K1.2,5
SerialNumber
lD No. ocL-PG-010
Ran8e/workins Ranse (bar) 0to16
Ieast Count (bar) 1

Location o{ Calibration Laboratory


OK

Date of lnst. Receipt 17 /0612011


1/ /A6/201 t
suggested oue Date 17/0612018
Service Request No. 44434

Calibration Procedure Thecalibration has been performed under controLled conditions usingOTS Laboratory reference
siandards, which are periodically refer€nced tooneormoreoftheprimarystandardstraceableto
NPVN ST or other national physical measures as equrvalent by NIST. The calibration had been
performed in accordance with calibration procedure COP/oTS/wl 03M lProcedure based on OKD-R6'
1).

Calibration Result The details of stJnoJrd equ pment used lor cahbratior & 'esull ol calibral,on are Srven rn
page 2 & 3.

Conclusion Forthe status ofmeasurements please referto the gurdance notes.

Environment: (certified against calibrated digital temperature & humidity meter)

remperature l'c) 2311


Eelative Humidity {%RHl 40 to 60

Change rn temperature and relative humidity of the Laboratory d!rlng the calibration was less than 0-3'C per hour and
5.0% pcr 4 hours respectively.

Thrs certificate rs issued strictlyln accordance with the requlrementsoflSO 17025r2005. Allcalbration equipmentsare
tr:rceable tothe nternationalStandards. Documentary evldence i5available upon request.

o11 ll17 -06)/4443A Page 1 of 3


ffir
@E@
a.difi cde \.'0,
()(lse
ull3/1677c

CERTIFICATE of CALIBRATION ,fA*ox


rssued by OTS (Pvt.) Limited q@9
Navana DH Tcwer, Level 3, 6 Panthapath, Dhaka-1215
Teli +88-02-9126028, 9124003, 01755585553-7
Fax: +88 02 58156739, E-mail: info@otsbd.com, www.otsbd.com
>K
cerifrcate No. c 0902 & a 1162

Oetails of Standard Equipment Used for Catibration:

Sl. No. Description Make lnst. Sl. /rD NO, Certificate No. Validity Calibrated 8y

01 Dead Werght Tester T11F153 cTtJ/c^t/fi-as/046 10/os/2019 c&t


Temp. & RH Data
02 Supco oTs/DL/01 501,6077 12/02l2Or8 BELZ

siatus A The measurement is wrthin tolcrance, due allowances having been made for the uncertainty of the measurement.

status a Thc mcasurement may be out of tolerance, due alowances having been made for the uncertainty of the measurernent.

Status C The measurementis outoftolerance, due allowances having been madeforthe uncertaintyofthe measurement,

Status o No concl!sron can be drawn, because the standard{, do(es)not specify a to erance for this measurement.

OBSERVATION: (verified against calibrated instruments)

Order
LJUC Value 5TO Avg. Value
Sl. No. Error (bar) Status
(ba4 (ba4
01 0.00 0.00 0.00 N/s D

02 5.00 5.03 -0.03 N/s D

03 10.00 1A AJ '0.07 N/S D ,1-2% af .de.


a4 12.00 12.09 0.09 N/S u
05 16.00 16.13 -0.13 N/S

UUC Value STD Avg. Value


Sl. No. Error (bar) Tolerance Status Uncertainty
(bar) (bar)
0l 16.00 16.13 -0.11 N/s D

o2 12.00 12.10 0.10 N/s o


03 10.00 10.08 -0.08 N/s D L.2% af ,de.
a4 5.00 5_04 o.o4 N/S D

05 0.00 o.o1 0.01 N/S D

o17 /117 06)14443A Pdde 2 ol l


cerlifet No, c{902 & Gr3E2

The overall uncertainty shatl be calculated as per lso


"Gulde to the Expression oft ncertalnty in Measuremene (6uM). The uncertalnty
represents an expanded uncertainty using a coverage factor k=2 to
approximate a 95% confldence level.

Notes:
1. The values mentioned above arethe mean readings.
2. No adjustmentwas done durlngthe caltbration.
3. Anysection marked, "N/A" means NotApplicablE "N/t/ means Not provided, .N/R, means Not Readable,.N/S" means NotSpecified.

Calibrdted By: Checked gy:

r.4*-raEii-
Md. xamran Md.qsadull.h Ghalib
(Calibratlon EnStneer)
F02( 5.4/01/C) tssue No. Ot Oateoftssue: Orlol2012

Page 3 of3