Siphon Tubes
Application Siphon tubes protect the pressure gauges
against excessive heating due to the
temperature of the measuring fluid.
The gauge is mounted directly on the
siphon tube or connected in serie with
a shut-off device.
Condensate is formed in the bent part and
this prevents excessive heating. We re-
commend to fill the tube with liquid before
starting. At extremely high temperatures,
a sufficiently long capillary should be used.
Materials Steel
Stainless steel
Execution DIN 16282 or common commercial-
shapes
Selection Chart
Dimensions Connections Operational data Material Ident. Number
Entry Exit Pressure bar Temp. °C
Steel N 05013.0000
Tappet Clamp muff 100 120
connection connection 80 300
G 1/2 G 1/2 63 400 Stainless steel N 05013.0001
DIN 16282 form A
Steel N 05013.0002
Clamp muff 100 120
Welding end
connection 80 300
ø 20
G 1/2 63 400 Stainless steel N 05013.0003
DIN 16282 form B
Steel N 05014.0000
Tappet Clamp muff 100 120
connection connection 80 300
G 1/2 G 1/2 63 400 Stainless steel N 05014.0001
DIN 16282 form C
www.baumerprocess.com Data-sheet A 53 D5.205
Design and specification subject to change without notice. Page
Selection chart
Dimensions Connections Operational data Material Ident. Number
Entry Exit Pressure bar Temp. °C
Steel N 05014.0002
Clamp muff 100 120
Welding end
connection 80 300
ø 20
G 1/2 63 400 Stainless steel N 05014.0003
DIN 16282 form D
Steel J 66865.0001
25 20
Tappet Tappet 16 120
connection connection 10 200
G 1/2 G 1/2 6 250 Stainless steel J 66865.0002
UK/2007-08-29 This data sheet may only be reproduced in full.
2,5 300
25 20
Tappet Clamp muff Steel J 66866.0001
16 120
connection connection
10 200
G 1/2 G 1/2
6 250
2,5 300
20
25
Tappet Tappet 120 Steel J 66867.0001
16
connection connection 200
10
G 1/2 G 1/2 250
6
300
2,5
25 20
Tappet Clamp muff Steel J 66868.0001
16 120
connection connection
10 200
G 1/2 G 1/2
6 250
2,5 300
www.baumerprocess.com Data-sheet A 53 D5.205
Design and specification subject to change without notice. Page