You are on page 1/ 203

Hydraulic Valves & Accessories

Category Page
Hydraulic Power & Control

Ball Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223


Check Valves, Pilot-Operated Check Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228
Counterbalance Valves (Overcenter Valves). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248
Cushion Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261
Directional Control Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265
Manually-Operated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265
Vickers® MPV1-10 Series 2-Way 2-Position Cartridge Valves (To 12 GPM & 3000 PSI) . . . . . . . . . . . . . . 265
Vickers® DG17V-3 Series Subplate Mounted (NFPA Size D03, ISO 4401 Size 03) . . . . . . . . . . . . . . . . . . 267
Monoblock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268
Eaton 30900 Series 1-3 Spool (To 5 GPM & 3000 PSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268
Pneumatic Power & Control

Walvoil SD4 Series (To 12 GPM Nominal, To 3600 PSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269


Walvoil SD5 Series (To 12 GPM Nominal, To 4600 PSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270
Walvoil SD11 Series (To 18 GPM Nominal, To 4600 PSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271
Brand Hydraulics AO755 Series 1 Spool (To 18 GPM & 3000 PSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273
Brand Hydraulics LS755 Series 1-Spool (To 18 GPM & 3000 PSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274
Brand Hydraulics SDCF Series 1-Spool (To 18 GPM & 3000 PSI). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275
Proportional . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276
Vickers® KDG4V-3 & -3S Series, without Feedback (NFPA Size D03, ISO 4401 Size 03) . . . . . . . . . . . . . 276
Vickers® KFDG4V-3 Series, with Feedback (NFPA Size D03, ISO 4401 Size 03) . . . . . . . . . . . . . . . . . . . 278
Sectional . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279
Walvoil SD6 Series (12 GPM Nominal, To 4600 PSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279
Husco Model 5000 (20 GPM Nominal Flow Rating, To 3000 PSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
Fluid Conveying

Walvoil SD8 Series (21 GPM Nominal Flow Rating, To 4600 PSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285
Walvoil SDS150 Series (24 GPM Nominal Flow Rating, To 4600 PSI). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289
Husco Model 6000 (40 GPM Nominal Flow Rating, To 3400 PSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
Walvoil SD16 Series (37 GPM Nominal Flow Rating, To 4600 PSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296
Walvoil SD25 Series (63 GPM Nominal Flow Rating, To 4600 PSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
Solenoid-Operated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302
Screw-In Cartridge Valves (2-way, 3-way, 4-way). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302
Vickers® DG4V-3 & -3S Series Subplate Mounted (NFPA Size D03, ISO 4401 Size 03) . . . . . . . . . . . . . . 337
Miscellaneous Products

Vickers® DG4V-3 Series Soft Shift Subplate Mounted (NFPA Size D03, ISO 4401 Size 03) . . . . . . . . . . . 342
Vickers® DG4S4-01 60 Series Subplate Mounted (NFPA Size D05, ISO 4401 Size 05) . . . . . . . . . . . . . . . 344
Vickers® DG4V4-01 10 Series High Pressure Subplate Mounted (NFPA Size D05, ISO 4401 Size 05) . . . 348
Vickers® DG4V5 20 Series High Pressure Subplate Mounted (NFPA Size D05, ISO 4401 Size 05) . . . . . 349
Vickers® DG4S4-01 60 Series Soft Shift Subplate Mounted (NFPA Size D05, ISO 4401 Size 05) . . . . . . . 351
Vickers® DG4S4-0150 Series (Air Gap) Subplate Mounted (NFPA Size D05, ISO 4401 Size 05) . . . . . . . 352
Vickers® DG5V-8 Series Subplate Mounted (NFPA Size D08, ISO 4401 Size 08) . . . . . . . . . . . . . . . . . . . 353
Vickers® DG5V-10 Series Subplate Mounted (NFPA Size D10, ISO 4401 Size 10) . . . . . . . . . . . . . . . . . . 354
Flow Control Valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 355
Logic Element Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 368
Flow Divider Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 369
Indexes & Technical Information

Gate Valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372


Needle Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
Plug Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377
Pressure Reducing Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 379
Direct-Acting (To 4 GPM & 2400 PSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 379
Pilot-Operated (To 10 GPM & 3500 PSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 380
Relief Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 382
Direct-Acting Ball Type Fast acting • Intermittent duty • Low cost • Possibly noisy • Higher overpressure . 382
Direct-Acting Poppet Type Fast acting • Continuous duty • Low cost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383
Direct-Acting Differential Poppet Type Fast acting • Intermittent duty • Contaminant tolerant . . . . . . . . . . . 385
Pilot-Operated Poppet Type Anti-Cavitation Make-Up Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 387

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
220
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Category Page

Hydraulic Power & Control


Pilot-Operated Spool Type Quiet, smooth & consistent • Continuous duty • Low overpressure . . . . . . . . . 388
Guided Piston Type Quiet • Stable • Flow Modulating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 393
Sandwich Valves (Aluminum Housings, Blanking-Linking-Spacer Plates) . . . . . . . . . . . . . . . . . . . . . . . . . 394
Selector Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 395
Slip-In Cartridge Valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 399
Stack Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400
NFPA Size D03 - ISO 4401 Size 03 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400
NFPA Size D05 - ISO 4401 Size 05 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 404
System Accessory Valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 406
Shuttle Valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 406

Pneumatic Power & Control


Truck Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 408
Hydraulic Valve Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 409
Bolt & Bolt Extender Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 409
Cartridge Valve Housings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 410
Cartridge Valve Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414
Solenoid Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415
Subplates, Manifolds, Cover Plates, Valve Adaptors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 418
Electronic Control Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 422
Valve Technical Information, Performance, Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 616
Ball Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 616
Apollo® Pressure-Temperature Graphs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 616
Directional Control Valves, Hydraulic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 619

Fluid Conveying
Brand AO755 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 619
Brand LS755 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 619
Brand SDCF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 620
Brand TS Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 621
Eaton 30900 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 622
Husco Model 5000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 623
Husco Model 6000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 624
Vickers® DG4V-3 & DG4V-3S Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 625

Miscellaneous Products
Vickers® DG4V-3 & DG4V-3S Series Soft Shift . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 628
Vickers® DG4S-01 Series, -60 Design (Wet Armature) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 629
Vickers® DG4S-01 Series Soft Shift, -60 Design, Wet Armature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 630
Vickers® DG4S-01 Series, -50 Design (Air Gap) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 631
Vickers® DG4V4-01 Series, -10 Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 632
Vickers® DG4V-5 Series, -20 Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 633
Vickers® DG5S-8 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 634
Vickers® DG5V-8 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 635
Vickers® DG5V-10 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 636
Walvoil DPC130 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 637
Walvoil SD4 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 638 Indexes & Technical Information
Walvoil SD5 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 639
Walvoil SD6 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 640
Walvoil SD8 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 641
Walvoil SD11 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 642
Walvoil SD16 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 643
Walvoil SD25 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 644
Walvoil SDS150 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 645
Relief Valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 646
Fulflo V Series Guided Piston Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 646
Stack Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 647
Vickers® NFPA-D03 SystemStak Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 647
Vickers® NFPA-D05 SystemStak Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 652
This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
221
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Category Page
Hydraulic Power & Control

Vickers® NFPA-D08 Stack Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 655


Pneumatic Power & Control
Fluid Conveying
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
222
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Ball Valves

Hydraulic Power & Control


Bronze
Apollo® 70-100 Series

Features: Chromium plated ball. RPTFE seats and stuffing box ring. Blow-out proof stem design. Adjustable
packing gland.
Standard Materials: Zinc plated steel lever (with vinyl cover) and lever nut. RPTFE seats, stem packing and stem

Pneumatic Power & Control


bearing. B16 chrome plated ball. B16 retainer (1/4 through 1 inch). B584-C84400 retainer (1-1/4 through 3
inch). B16 gland nut and stem. PTFE body seal (1-1/4 through 3 inch). B584-C84400 body.
Pressure Ratings: 600 psig WOG, Cold Non-Shock. 150 psig Saturated Steam. Vacuum service to 29 in./Hg.
Note: Valves have a reduced pressure rating at elevated temperatures. See "600# Bronze P-T Rating (Graph 4)
on page 616
Note: Numerous options are available on special order. Contact us for assistance.
Seal Kits: page 227
Bronze • Apollo® 70-100 Series
Ball
Catalog Orifice CV Price
Part No. Apollo Model Ports Dia. Rating Special Features Seal Kit Wt. Each
•C1EN78 70-101-01 1/4 NPT 0.37 8.4 70-002-01 0.58

Fluid Conveying
•C1EN82 70-103-01 1/2 NPT 0.50 15 70-003-01 0.63
•C1EN84 70-104-01 3/4 NPT 0.68 30 70-004-01 1.39
•C1EN86 70-105-01 1 NPT 0.87 43 70-005-01 1.72
C1EN94 70-108-C5 2 NPT 1.50 108 Light Lever 70-008-01 6.06
C1EN95 70-109-01 2-1/2 NPT 2.00 503 70-009-01 17.25
•C1EN77 70-100-01 3 NPT 2.50 370 70-009-01 17.25

Miscellaneous Products
Brass
Stuaff 2BVL Series

Features: Brass Hot Stamping with Chrome Plated Brass Ball. Blow Out Proof Stem. Teflon Seats, Seals & Thrust
Washer. Metal Handle.
Maximum Operating Pressure: Up to 600 PSI
Temperature Range: Indexes & Technical Information

Brass • Stuaff 2BVL Series


Maximum
Working
Catalog Pressure Price
Part No. Stauff Model Ports (psi) Special Features Wt. Each
C1KJ71 2BVL2024F 1-1/2 NPT 362 2.20
C1KJ72 2BVL2032F 2 NPT 362 4.50

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
223
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Ball Valves
Hydraulic Power & Control

Bronze (3-Way)
Apollo® 70-600 Series

Features: Chromium plated ball. RPTFE seats and stuffing box ring. Blow-out proof stem design. Adjustable
packing gland.
Standard Materials: Zinc plated steel lever (with vinyl cover) and lever nut. RPTFE seats, stem packing and stem
Pneumatic Power & Control

bearing. B16 chrome plated ball. B16 retainer (1/2 to 1 inch). B584-C84400 retainer (1-1/4 to 2 inch). B16
gland nut and stem. PTFE body seal (1-1/2 to 2 inch). B584-C84400 body.
Pressure Ratings: 400 psig WOG, Cold Non Shock.
Note: Valves have a reduced pressure rating at elevated temperatures. See "600# Bronze P-T Rating (Graph 4)
on page 616
Note: Numerous options are available on special order. Contact us for assistance.
Seal Kits: page 227
Bronze (3-Way) • Apollo® 70-600 Series
Ball
Catalog Orifice CV Price
Part No. Apollo Model Ports Dia. Rating Special Features Seal Kit Wt. Each
•C1EW29 70-602-01 3/8 NPT 0.37 8.4 70-002-01 0.89
Fluid Conveying

•C1EN96 70-603-10 1/2 NPT 0.50 5.4 SS Lever & Nut 70-003-01 0.76
•C1EN97 70-604-10 3/4 NPT 0.68 12 SS Lever & Nut 70-004-01 1.65

Steel - Barstock Body


Apollo® 73-100 Series
Miscellaneous Products

Features: Barstock design. RPTFE seats and stuffing box ring. Fire safe design when ordered with graphite
packing. Adjustable packing gland. Blow-out proof stem design. Nitride corrosion protection.
Standard Materials: Zinc plated steel lever (with vinyl cover) and lever nut. RPTFE seats, stem packing and stem
bearing. A 108-CS chrome plated ball. A 108-CS retainer. A 108-CS gland nut and stem. PTFE body seal
(1-1/4 through 2 inch). A 108-CS body.
Pressure Ratings: 1/4 to 1 inch: 2000 psig WOG, Cold Non-Shock. 1-1/4 to 2 inch: 1500 psig WOG, Cold
Non-Shock. 150 psig Saturated Steam. Vacuum service to 29 in./Hg.
Note: Valves have a reduced pressure rating at elevated temperatures. For 1/4 inch to 1 inch sizes, see "2000#
Indexes & Technical Information

CS P-T Rating (Graph 13) on page 617 . For 1-1/4 inch to 2 inch sizes, see "1500# CS P-T Rating (Graph 11)
on page 617
Note: Numerous options are available on special order. Contact us for assistance.
Seal Kits: page 227
Steel - Barstock Body • Apollo® 73-100 Series
Ball
Catalog Orifice CV Price
Part No. Apollo Model Ports Dia. Rating Special Features Seal Kit Wt. Each
C1KU53 2BVM2006S 0.53
•C1EP14 73-104-01 3/4 NPT 0.68 30 70-004-01 1.58

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
224
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Ball Valves

Hydraulic Power & Control


Steel - Barstock Body
Stauff BBVM Series

Features: Fully ported. Carbon steel body. Chrome plated brass ball. 50,000 cycle seal life. Delrin seats.
Viton® O-Rings.
Maximum Operating Pressure: Sizes 1/4 - 1/2: 7250 PSI. Sizes 3/4 - 1: 5000 PSI. Sizes 1-1/4 - 1-1/2: 3600 PSI.
Temperature Range: -14°F to 212°F.

Pneumatic Power & Control


Steel - Barstock Body • Stauff BBVM Series
Maximum
Working
Catalog Pressure Price
Part No. Stauff Model Ports (psi) Special Features Wt. Each
C1ZT41 BBVM21120201M 3/4 SAE 5000 0.79 3.50
•C1FD90 BBVM20040201 1/4 NPT 7250 0.66
•C1FD91 BBVM20060201 3/8 NPT 7250 1.10
•C1FD92 BBVM20080201 1/2 NPT 7250 1.65
•C1KL30 BBVM20120200K 3/4 NPT 6000 3.60
•C1FD94 BBVM20160201 1 NPT 5000 5.06
•C1FD97 BBVM21040201 SAE-04 7250 0.66
•C1FD98 BBVM21060201 SAE-06 7250 1.10

Fluid Conveying
•C1FD99 BBVM21080201 SAE-08 7250 1.65
C1JS23 BBVM21080200M/LD SAE-08 7250 Locking Device 1.53
C1FE11 BBVM21120201 SAE-12 5000 3.65
•C1JS24 BBVM21120200M/LD SAE-12 5000 Locking Device 3.59
C1JS25 BBVM21160200M/LD SAE-16 5000 Locking Device 5.21

Miscellaneous Products
Steel - Forged Body
Stuaff FBV Series

Features: Forged Body, High Pressure Valves. Steel Handle. Delrin +MoS2 Ball Seats. Viton O-Rings. Zinc
Plated Body.
Maximum Operating Pressure: 5000 PSI
Temperature Range: -20?F to 212?F
Steel - Forged Body • Stuaff FBV Series
Maximum
Working Indexes & Technical Information
Catalog Pressure Price
Part No. Stauff Model Ports (psi) Special Features Wt. Each
C1KL79 FBV21200001MLD SAE-20 5000 Locking Device 8.60
C1KL80 FBV21240001M/LD SAE-24 5000 Locking Device 3.25

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
225
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Ball Valves
Hydraulic Power & Control

Stainless Steel
Apollo® 76-100 Series

Features: Investment cast components. RPTFE seats and stuffing box ring. Mounting pad for easy actuator
mounting. Blow-out proof stem design. Adjustable packing gland. Meets NACE MR-01-75. Stainless steel
Pneumatic Power & Control

lever & nut.


Standard Materials: 304 SS lever (with vinyl cover). 18-8 SS lever nut. RPTFE seats, stem packing and stem
bearing. A276-316 ball. A276-316 retainer (1/4 to 1 inch). A351-CF8M retainer (1-1/4 to 3 inch). A276-316
gland nut and stem. PTFE body seal (1-1/4 through 2 inch). A351-CF8M body.
Pressure Ratings: 1/4 to 1 inch: 2000 psig WOG, Cold Non-Shock. 1-1/4 to 2 inch: 1500 psig WOG, Cold
Non-Shock. 2-1/2 to 3 inch: 1000 psig WOG, Cold Non-Shock. 150 psig Saturated Steam. Vacuum service
to 29 in./Hg.
Note: Valves have a reduced pressure rating at elevated temperatures. For 1/4 to 1 inch sizes, see "2000# SS
P-T Rating (Graph 14) on page 618
Note: Numerous options are available on special order. Contact us for assistance.
Seal Kits: page 227
Stainless Steel • Apollo® 76-100 Series
Fluid Conveying

Ball
Catalog Orifice CV Price
Part No. Apollo Model Ports Dia. Rating Special Features Seal Kit Wt. Each
•C1EP21 76-101-01 1/4 NPT 0.37 8.4 70-002-01 0.58
•C1EP22 76-102-01 3/8 NPT 0.37 7.2 70-002-01 0.54
•C1EP23 76-103-01 1/2 NPT 0.50 15 70-003-01 0.63
•C1EP24 76-104-01 3/4 NPT 0.68 30 70-004-01 1.27
Miscellaneous Products

Stainless Steel (3-Way)


Apollo® 76-600 Series

Features: RPTFE seats and stuffing box ring. Meets NACE MR-01-75. Blow-out proof stem design. Adjustable
packing gland. Investment cast body.
Standard Materials: 304 SS lever (with vinyl cover). 18-8 SS lever nut. RPTFE seats, stem packing and stem
bearing. A276-316 ball. A276-316 retainer (1/2 to 1 inch). A351-CF8M retainer (1-1/2 to 2 inch). A276-316
Indexes & Technical Information

gland nut and stem. PTFE body seal (1-1/2 to 2 inch). A351-CF8M body.
Pressure Ratings: 800 psig WOG, Cold Non Shock.
Note: Valves have a reduced pressure rating at elevated temperatures. See "800# SS P-T Rating (Graph 21) on
page 618
Note: Numerous options are available on special order. Contact us for assistance.
Seal Kits: page 227
Stainless Steel (3-Way) • Apollo® 76-600 Series
Ball
Catalog Orifice CV Price
Part No. Apollo Model Ports Dia. Rating Special Features Seal Kit Wt. Each
C1EP27 76-603-01 1/2 NPT 0.50 5.4 70-003-01 0.75

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
226
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Ball Valves

Hydraulic Power & Control


Apollo® Ball Valve
Seal Kits

Apollo® Ball Valve • Seal Kits


Catalog Price
Part No. Apollo Model Description Wt. Each

Pneumatic Power & Control


70-100, 70-800, 73-100 Series (2 in. size). 77-100 Series (1-1/2 in size). 70-600 Series (2 in.
C1EN75 70-008-01 size). 0.12

Fluid Conveying
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
227
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Check Valves
Hydraulic Power & Control

Inline Check Valves


For Hydraulic (To 12 GPM) & Pneumatic Service
Pneumatic Power & Control

Features: Low pressure differential required to open & close.


Application: Free flow is permitted in the direction of the arrow; positive check in the opposite direction. Brass
valves for use in pneumatic systems and lower pressure hydraulic systems. Steel valves for use in hydraulic
systems. Pressure ratings in tables are for non-shock service.
Materials: Body: Available in Brass, Carbon Steel or Stainless Steel.
Inline Check Valves • For Hydraulic (To 12 GPM) & Pneumatic Service
Maximum
Operating
Pressure Flow Cracking
Catalog Body Non-Shock Rating CV Pressure A C E Price
Part No. Deltrol Model Size Threads Material (psi) (GPM) Factor (PSI) (in) (in) (in) Wt. Each
•C1CM26 C20B 1/4 1/4-18 NPT Brass 2000 3.0 0.54 1 to 2.5 .88 0.36 2.00 0.36
C1CM36 C30B 1/2 1/2-14 NPT Brass 2000 8.0 1.47 1 to 2.5 1.31 0.47 2.66 0.89
Fluid Conveying

Inline Check Valves


For Water, Steam, Oil, Chemicals
Miscellaneous Products

Features: Fully-formed stainless steel poppet, metal-to-metal seal, ruggedly constructed. Less than 1 psi
cracking pressure. No o-rings are used.
Application: For a wide variety of applications, including hot water, cold water, steam, oil, gas, compounds and
chemicals. Not for air compressor service.
Materials: Cast brass 1-piece body, stainless steel poppet.
Maximum Working Pressure: 200 lbs. WOG, 75 lbs. steam.
Maximum Operating Temperature: 300°F.
Indexes & Technical Information

Inline Check Valves • For Water, Steam, Oil, Chemicals


Catalog CV Price
Part No. Strataflo Model Size Ports Factor Dimensions (in) Wt. Each
•C1JR70 400-050 1/2 1/2-14 NPT 2.60 1.40 Diameter, 2.69 Long 0.65

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
228
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Check Valves

Hydraulic Power & Control


Inline Check Valves
For Hydraulic (To 55 GPM) & Pneumatic Service

Pneumatic Power & Control


Features: High flow rating. Low pressure differential required to open & close.
Application: Free flow is permitted in the direction of the arrow; positive check in the opposite direction. Brass
valves for use in pneumatic systems and lower pressure hydraulic systems. Steel valves for use in hydraulic
systems. Pressure ratings in tables are for non-shock service.
Materials: Body: Available in Brass, carbon steel or stainless steel (1" size available in naval bronze or ductile
iron). Ball and Spring: Stainless steel. Ball Follower: Delrin. Retainer: Stainless steel.
Maximum Operating Temperature: 200°F.
Inline Check Valves • For Hydraulic (To 55 GPM) & Pneumatic Service
Maximum
Operating
Pressure Flow Cracking
Catalog Body Non-Shock Rating CV Pressure E Price
Part No. Deltrol Model Size Threads Material (psi) (GPM) Factor (PSI) (in) F (in) Wt. Each

Fluid Conveying
•C1CN88 EC10B 1/8 1/8-27 NPT Brass 2000 3.0 0.75 1 to 2.5 0.63 1.69 0.15
•C1CN89 EC20B 1/4 1/4-18 NPT Brass 2000 6.0 1.47 1 to 2.5 0.75 2.00 0.22
C1CN90 EC20S 1/4 1/4-18 NPT Steel 5000 6.0 1.47 1 to 2.5 0.75 2.00 0.20
•C1CN93 EDC25B 3/8 3/8-18 NPT Brass 2000 10.0 3.30 1 to 2.5 1.00 2.50 0.49
•C1CN94 EDC25S 3/8 3/8-18 NPT Steel 5000 10.0 3.30 1 to 2.5 1.00 2.50 0.45
C1CN95 EDC30B 1/2 1/2-14 NPT Brass 2000 12.0 3.60 1 to 2.5 1.13 2.88 0.65
C1CN96 EDC30S 1/2 1/2-14 NPT Steel 5000 12.0 3.60 1 to 2.5 1.13 2.88 0.59

Miscellaneous Products
•C1CN97 EDC35B 3/4 3/4-14 NPT Brass 2000 20.0 5.41 1 to 2.5 1.38 3.25 0.98
C1CN98 EDC35S 3/4 3/4-14 NPT Steel 5000 20.0 5.41 1 to 2.5 1.38 3.25 0.98
•C1CN92 EC40S 1 1-11-1/2 NPT Steel 5000 55.0 9.60 3 to 5 1.75 4.50 2.48

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
229
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Check Valves
Hydraulic Power & Control

Inline Check Valves (Male Threads)


For Hydraulic (To 15 GPM) & Pneumatic Service
Pneumatic Power & Control

Features: Soft seat for bubble-tight seal (CMMO & CMMQ models). Compact overall length. Low pressure
differential required to open & close.
Application: Free flow is permitted in the direction of the arrow; positive check in the opposite direction. Brass
valves for use in pneumatic systems and lower pressure hydraulic systems. Steel valves for use in hydraulic
systems. Pressure ratings in tables are for non-shock service.
Materials: Body: Available in Brass, Carbon Steel or Stainless Steel. Ball: Stainless steel. Retainer: Stainless
steel.
Operating Temperature Range: -30°F to 250°F (Soft seat CMMO & CMMQ models).
Inline Check Valves (Male Threads) • For Hydraulic (To 15 GPM) & Pneumatic Service
Maximum
Operating
Pressure Flow Cracking
Catalog Body Non-Shock Rating CV Pressure A B Price
Fluid Conveying

Part No. Deltrol Model Size Threads Material (psi) (GPM) Factor (PSI) (in) (in) Wt. Each
•C1CN38 CMMQ20B 1/4 1/4-18 NPT Brass 2000 2.5 0.56 1 to 2.5 1.38 0.63 0.08
•C1CN39 CMMQ20S 1/4 1/4-18 NPT Steel 3000 2.5 0.56 1 to 2.5 1.38 0.63 0.08
•C1CN40 CMMQ30B 1/2 1/2-14 NPT Brass 1000 10.0 2.71 1 to 2.5 2.06 0.88 0.22
Note: CMMO and CMMQ models have soft seat. CMM models have metal-to-metal seat.
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
230
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Check Valves

Hydraulic Power & Control


Cartridge Type Check Valve
Vickers® CV13-10 Series • To 5000 PSI & 20 GPM

Pneumatic Power & Control


Description: This is a compact poppet type check valve ideal for use in manifolds for load sense or low flow
applications.
Operation: The valve remains closed until the spring bias is reached at port 1 at which time the poppet lifts of the
seat and allows flow from port 1 to port 2. in the other direction the valve is closed.
Rated Flow: 20 GPM.
Maximum Operating Pressure: 5000 PSI.
Temperature Range: –40° to 248° F
Recommended Filtration Level: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Internal Leakage: 5 drops/min. maximum @ 5000 psi.

Fluid Conveying
Cartridge: Model CV13-10-*, sold separately.
Housing: Cavity Size C-10-2, sold separately, see page 410
Cartridge Type Check Valve • Vickers® CV13-10 Series • To 5000 PSI & 20 GPM
Catalog Vickers Part
Part No. No. Vickers Model Cracking Pressure (psi) Housing Seal Material Wt. Price Each
C1MG21 02-200444 CV13-10-P-0-210 210 None Buna-N 0.17

Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
231
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Check Valves
Hydraulic Power & Control

Cartridge Type Check Valves


Vickers® CV1-16 Series • To 3000 PSI & 40 GPM
Pneumatic Power & Control

Application: Used in hydraulic applications to allow free flow of fluid in one direction only.
Rated Flow: 40 GPM.
Maximum Operating Pressure: 3000 PSI.
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration Level: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model CV1-16*, sold separately.
Fluid Conveying

Housing: Cavity size C-16-2, sold separately, see page 410


Cartridge Type Check Valves • Vickers® CV1-16 Series • To 3000 PSI & 40 GPM
Catalog Cracking Pressure Price
Part No. Vickers Part No. Vickers Model (psi) Seal Material Wt. Each
C1MG58 565973 CV1-16-P-0-20 20 Buna-N 0.58
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
232
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Check Valves

Hydraulic Power & Control


Cartridge Type Check Valves
Integrated Hydraulics 4CA300 Series • To 5000 PSI & 80 GPM

Pneumatic Power & Control


Application: Used in hydraulic applications to allow free flow of fluid in one direction only.
Rated Flow: 80 GPM.
Maximum Operating Pressure: 5000 PSI
Temperature Range: –22° to 194°F
Recommended Filtration Level: Cleanliness level 18/13 or better.
Cartridge: Model 3CA300-*, sold separately.

Fluid Conveying
Housing: Cavity size A13245, sold separately, see page 410
Cartridge Type Check Valves • Integrated Hydraulics 4CA300 Series • To 5000 PSI & 80 GPM
Catalog
Part No. Eaton Part No. Eaton Model Cracking Pressure (psi) Housing Seal Material Wt. Price Each
C1MG47 401AA00180A 3CA300-0.3S 4.4 None Nitrile 1.06

Miscellaneous Products
Inline Check Valves
Vickers® DS8P1 & DT8P1 Series • To 3000 PSI & 50 GPM

Application: Used in hydraulic applications to allow free flow of fluid in one direction only. Indexes & Technical Information
Construction: Steel body. No elastomer seals.
Maximum Operating Pressure: 3000 PSI (Designed for low shock service. Do NOT use this valve to check a
high velocity reverse flow resulting in shock conditions).
Inline Check Valves • Vickers® DS8P1 & DT8P1 Series • To 3000 PSI & 50 GPM
Flow Cracking
Catalog Rating Pressure Price
Part No. Vickers Part No. Vickers Model Size Threads (gpm) (psi) A B Wt. Each
C1AH96 114088 DT8P1-02-5-10 1/4 1/4 NPT 3.2 5 2.25 0.88 0.50
C1JM59 117378 DT8P1-03-5-10 3/8 3/8 NPT 8.0 5 3.00 1.00 0.75
•C1AJ60 125670 DT8P1-06-5-11 3/4 3/4 NPT 20 5 3.88 1.50 1.50
C1AJ58 125667 DT8P1-10-5-11 1-1/4 1-1/4 NPT 50 5 5.25 2.50 6.00

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
233
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Check Valves
Hydraulic Power & Control

Inline Check Valves


Stauff RV Series • To 7250 PSI
Pneumatic Power & Control

Specifications: Sizes to 2 inch. Carbon steel body, zinc plated. Working pressure to 7250 PSI (see table for
actual rating for a given size). Metal to metal seat.
Options: NPT or SAE ports. Two cracking pressures (7 PSI or 65 PSI). Special cracking pressures available on
request.
Inline Check Valves • Stauff RV Series • To 7250 PSI
Catalog D Price
Part No. Stauff Model Size Threads Operating Pressure (PSI) Cracking Pressure (psi) (in) L (in) Wt. Each
•C1HX34 RV127S 1/2 SAE-8 7250 7 1.38 2.87 1.54
•C1HX35 RV167S 3/4 SAE-12 7250 7 1.77 3.46 2.64
•C1HX36 RV207S 1 SAE-16 7250 7 1.97 5.00 4.40
Fluid Conveying

Inline Check Valves


DMIC CVH Series • To 10,000 PSI (At Reduced Safety Factor)
Miscellaneous Products

Features: Capable of sustained high pressure operation to 10,000 PSI (Smaller sizes, with reduced safety factor).
The precision ground seat and hardened poppet check element eliminate leakage. Superior check valve
retainer design prevents spring from fully packing, thereby softening the opening impact and extending service
life.
Construction: Allow steel body and piston. Black oxide coating on body. Precision hard seat piston seal. High
strength spring steel spring.
Inline Check Valves • DMIC CVH Series • To 10,000 PSI (At Reduced Safety Factor)
Minimum
Indexes & Technical Information

Working Burst
Catalog Flow Rating (GPM @ 300 PSI Pressure Pressure C D Price
Part No. DMIC Model Size Threads Drop) (psi) (psi) (in) (in) Wt. Each
•C1EK50 CVH05-1000N 1 1 NPT 158 6,000 19,500 4.27 1.81 2.13
C1EK51 CVH05-1250-N 1-1/4 1-1/4 NPT 200 6,000 19,500 4.88 2.17 3.42
CAUTION: The manufacturer's pressure and flow ratings are extremely liberal and should be interpreted with caution (Low safety factors are
used on pressure ratings, and high pressure drops are used on flow ratings).

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
234
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Check Valves

Hydraulic Power & Control


Cartridge Type Check Valves
Vickers® CV2-20-P Series • To 3000 PSI & 60 GPM

Cartridge Type Check Valves • Vickers® CV2-20-P Series • To 3000 PSI & 60 GPM
Catalog Vickers Part Price
Part No. No. Vickers Model Description Wt. Each

C1KB69 565844 CV2-20-P-0-5 Check Valve Cartridge, Cartridge Only, C-20-2 Cavity Size, 5 PSI Cracking 1.06
Pressure, Buna-N Seals

Pneumatic Power & Control


Note: Please contact us for technical & application information on these valves.

Right Angle Check Valves


Vickers® C2-8 Series • To 3000 PSI • To 100 GPM

Fluid Conveying
Miscellaneous Products
Right Angle Check Valves are designed for higher flows with less pressure drop. The valves' seat and poppet are
of hardened and ground steel for improved cycle life.
Maximum Operating Pressure: 3000 PSI.
Right Angle Check Valves • Vickers® C2-8 Series • To 3000 PSI • To 100 GPM
Nominal Apprx Indexes & Technical Information
Cracking Flow Pressure
Catalog Vickers Vickers Pressure Rating Drop at Rated Seals & Price
Part No. Part No. Model Ports (PSI) (GPM) Flow (PSI) Options Dimensions (in) Wt. Each

C1HH55 094029 C2-815 3/4 NPT 5 16 20 Buna-N A=3.88 B=1.75 C=2.00 5.00
D=2.75 E=1.81 F=3.19
C1HL46 094043 C2-820 1 NPT 5 28 14 Buna-N A=4.56 B=1.84 C=2.25 7.44
D=3.25 E=2.25 F=3.88

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
235
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Check Valves
Hydraulic Power & Control

Subplate/Manifold Mount Check Valves


Vickers® C5G & C5GV Series • To 5000 PSI • To 100 GPM
Pneumatic Power & Control
Fluid Conveying

Description: Subplate mounted check valve, allows flow in one direction only. Can be used with hydraulic oils,
water-in-oil emulsions and water glycols.
Pressure & Flow Ratings: See table below.
Temperature Range: -4°F to 176°F.
Recommended Filtration Level: ISO 4406 Cleanliness Level 20/18/15 or cleaner.
Subplate/Manifold Mount Check Valves • Vickers® C5G & C5GV Series • To 5000 PSI • To 100 GPM
Nominal
Flow Pressure Cracking
Miscellaneous Products

Catalog Vickers Part Rating Rating Pressure Other Price


Part No. No. Vickers Model Nominal Size (gpm) (psi) (psi) Seals Features Wt. Each
Dual
Metric/Inch
C1JM54 614374 C5GV-825UG 1-1/4 100 5000 5 Buna-N Hold Down 12.80
Bolt Facility
Dual
C1JM55 614382 C5GV-825UG-S8 1-1/4 100 5000 75 Buna-N Metric/Inch 12.95
Hold Down
Bolt Facility
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
236
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Pilot Operated Check Valves

Hydraulic Power & Control


Introduction to Pilot-Operated Check Valves (Lock Valves)
Application: Pilot Operated Check Valves (Lock Valves) are designed to lock a cylinder, without leakage, while a
control valve is in a neutral position. Lock Valves function as Check Valves, allowing flow to a cylinder and
blocking reverse flow until pilot pressure is applied to unlock the circuit. These valves may be used to prevent
movement of a load while the pressure source is inactive. A 4-way control valve is required for all lock valve
circuits, including single acting cylinders, in order to apply unlocking pressure to the pilot circuit. A control valve
with a free-flow (motor) spool should be used on any circuit which includes a lock valve to prevent pressure
build-up between the lock valve and the control valve.

Pneumatic Power & Control


Unlocking Pressure (Single Acting Cylinders): Pressure required in the pilot circuit = 25% of the locked
pressure.

Unlocking Pressure (Double Acting Cylinders): To unlock Blind End of cylinder, pressure required in the pilot
circuit = Blind End Locked Pressure/[4.0 - (Rod End Locked Pressure/((Cyl Area - Rod Area)/Cyl Area)]. To
unlock Rod End of cylinder, pressure required in the pilot circuit = Rod End Locked Pressure/[4.0 - (Head End
Locked Pressure/((Cyl Area - Rod Area)/Cyl Area)].

Caution: When the rod end of a double acting cylinder is locked, if the rod diameter exceeds approximately 75%
of the cylinder diameter, unlocking pressure becomes excessive and a lock valve should not be used.

Important Lock Valve Basics: Always follow catalog recommendations and application directions • Consult with
our representative or the factory when in doubt • When applying lock valves to life carrying machines such as

Fluid Conveying
boom/utility type equipment, do not separate the valve from the actuator... close-couple the valve to the actuator
• Do not use pilot operated check valves in load holding applications where either overrunning loads are
possible, or load release speed is critical • Care should be taken to ensure the load is supported by mechanical
means when servicing or removing the valve (CAUTION: When servicing the equipment, trapped pressure may
be present in the holding valve circuit. Carefully bleed down the trapped pressure before disassembly) • The
cylinder and it's seals must be in good condition.

Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
237
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Pilot Operated Check Valves
Hydraulic Power & Control

Cartridge Type Single Pilot Operated Check Valves


Vickers® SPC2-10 Series • To 3000 PSI & 6 GPM
Pneumatic Power & Control

Application & Operation: See Introduction to Pilot-Operated Check Valves (Lock Valves) at the beginning of this
section.
Fluid Conveying

Ratio of Pilot Piston Area to Check Valve Seat Area: 4:1.


Rated Flow: 6 GPM.
Maximum Operating Pressure: 3000 PSI.
Recommended Fluid Temperature Range: -4°F to 150°F (180°F is extreme condition upper limit).
Recommended Filtration Level: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SPC2-10*, sold separately.
Housing: Cavity size C-10-3, sold separately, see page 411
Miscellaneous Products

Cartridge Type Single Pilot Operated Check Valves • Vickers® SPC2-10 Series • To 3000 PSI & 6 GPM
Catalog Cracking Pressure Price
Part No. Vickers Part No. Vickers Model (psi) Seal Material Wt. Each
C1EN54 565619 SPC2-10-P-0-25 25 Buna-N 0.22
Note: Housing not included.
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
238
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Pilot Operated Check Valves

Hydraulic Power & Control


Cartridge Type Single Pilot Operated Check Valves
Integrated Hydraulics 4CK30 Series • To 5000 PSI & 8 GPM

Pneumatic Power & Control


Application & Operation: See Instruction to Pilot-Operated Check Valves (Lock Valves) at the beginning of
section.
Ratio of Pilot Piston to Check Valve Seat Area: 3:1
Rated Flow: 8 GPM
Maximum Operating Pressure: 5000 PSI
Recommended Fluid Temperature Range: -22° to +194°F

Fluid Conveying
Recommended Filtration Level: Cleanliness level 19/13 or better
Cartridge: Model 4CK30, sold separately
Housing: Cavity Size A6610, sold separately. For single valve housings, see page 411 For dual valve housings,
see page 412
Cartridge Type Single Pilot Operated Check Valves • Integrated Hydraulics 4CK30 Series • To 5000 PSI &
8 GPM
Catalog Price
Part No. Eaton Part No. Eaton Model Cracking Pressure (psi) Seal Material Special Features Wt. Each

Miscellaneous Products
C1MG43 401AA00001A 4CK301S 29 Nitrile None
C1MG44 401AA00002A 4CK301S3 29 Nitrile Pilot Seal

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
239
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Pilot Operated Check Valves
Hydraulic Power & Control

Inline Single Pilot Operated Check Valves


Vickers® SPC1-10 Series • To 3000 PSI & 12 GPM
Pneumatic Power & Control
Fluid Conveying

Application & Operation: See Introduction to Pilot-Operated Check Valves (Lock Valves) at the beginning of this
section.
Ratio of Pilot Piston Area to Check Valve Seat Area: 4:1.
Rated Flow: 12 GPM.
Maximum Operating Pressure: 3000 PSI.
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration Level: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Miscellaneous Products

Cracking Pressure: 15 PSI.


Inline Single Pilot Operated Check Valves • Vickers® SPC1-10 Series • To 3000 PSI & 12 GPM
Pilot
Catalog Pilot Port Piston Price
Part No. Vickers Part No. Vickers Model Valve & Cylinder Port Size Size Seal Seals Wt. Each
•C1DU37 02-161199 SPC1-10-P-6T SAE-6 SAE-4 No Buna-N 1.13
•C1FD38 565875 SPC1-10-P-8T SAE-8 SAE-4 No Buna-N 1.12
Note: These valves are sold as a complete assembly.
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
240
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Pilot Operated Check Valves

Hydraulic Power & Control


Cylinder Port Single Pilot Operated Check Valves
Brand PC-50 Series • To 3000 PSI & 16 GPM

Pneumatic Power & Control


Application & Operation: See Introduction to Pilot-Operated Check Valves (Lock Valves) at the beginning of this
section.
Ratio of Pilot Piston Area to Check Valve Seat Area: 4:1.
Construction: Cast iron body. Chrome alloy steel ball. Delrin check seat. Buna-N O-Rings.
Nominal Flow Rating: Varies with size. See table below.
Maximum Operating Pressure: 3000 PSI.
Cylinder Port Single Pilot Operated Check Valves • Brand PC-50 Series • To 3000 PSI & 16 GPM
Catalog Price
Part No. Brand Model Main Ports Pilot Port Nominal Flow Rating (GPM) Wt. Each

Fluid Conveying
•C1HG65 PC37C 3/8 NPT 1/4 NPT 8 GPM 0.82
•C1EF82 PC-50C 1/2 NPT 1/4 NPT 16 GPM 1.45

Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
241
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Pilot Operated Check Valves
Hydraulic Power & Control

Cartridge Type Single Pilot Operated Check Valves


Integrated Hydraulics 4CKD90 Series • To 6000 PSI & 24 GPM
Pneumatic Power & Control
Fluid Conveying

Application & Operation: A decompression pilot check can be used in most applications that use a standard pilot
operated check. Free flow in one direction and load holding in the other. The decompression feature allows
locked-in pressure to decay in a controlled fashion, reducing hydraulic noise and instability caused by the rapid
loss of energy from the actuator. The valve is effective in clamping circuits and when used with intensifiers or
when there are high load induced pressures.
Miscellaneous Products

Pilot Ratio: 25:1 decompression stage, 3:1 main stage


Rated Flow: 24 GPM
Maximum Operating Pressure: Cylinder Port 1: 6000 psi, Ports 2 & 3: 5000 psi
Operating Temperature: -22° to +194°F
Recommended Filtrations Level: 18/13
Cartridge: Model 4CKD90, sold seperately
Housing: Cavity Size A12336, sold separately.
Cartridge Type Single Pilot Operated Check Valves • Integrated Hydraulics 4CKD90 Series • To 6000 PSI &
24 GPM
Integrated
Catalog Hydraulics Part Price
Indexes & Technical Information

Part No. No. Integrated Hydraulics Model Pilot Ratio Seal Material Wt. Each
C1LX24 401AA00006A 4CKD901S3 25:1 Nitrile

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
242
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Pilot Operated Check Valves

Hydraulic Power & Control


Inline Single Pilot Operated Check Valves
Vickers® SPC1-16 Series • To 3000 PSI & 40 GPM

Pneumatic Power & Control


Fluid Conveying
Application & Operation: See Introduction to Pilot-Operated Check Valves (Lock Valves) at the beginning of this

Miscellaneous Products
section.
Ratio of Pilot Piston Area to Check Valve Seat Area: 4:1.
Rated Flow: 40 GPM.
Maximum Operating Pressure: 3000 PSI.
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration Level: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cracking Pressure: 20 PSI.
Inline Single Pilot Operated Check Valves • Vickers® SPC1-16 Series • To 3000 PSI & 40 GPM
Pilot
Catalog Pilot Port Piston Price
Part No. Vickers Part No. Vickers Model Valve & Cylinder Port Size Size Seal Seals Wt. Each Indexes & Technical Information
•C1FR18 02-112763 SPC1-16-P-12T SAE-12 SAE-6 No Buna-N 4.17
Note: These valves are sold as a complete assembly.

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
243
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Pilot Operated Check Valves
Hydraulic Power & Control

Cartridge Type Single Pilot Operated Check Valves


Integrated Hydraulics 4CK300 Series • To 5000 PSI & 80 GPM
Pneumatic Power & Control

Application & Operation: See Instruction to Pilot-Operated Check Valves (Lock Valves) at the beginning of
section.
Ratio of Pilot Piston to Check Valve Seat Area: 3:1
Rated Flow: 80 GPM.
Maximum Operating Pressure: 5000 PSI.
Recommended Fluid Temperature Range: -22° to +194°F
Fluid Conveying

Recommended Filtration Level: Cleanliness level 19/13 or better


Cartridge: Model 4CK300, sold separately.
Housing: Cavity Size A6935, sold separately. For single valve housings, see page 411 For dual valve housings,
see page 412
Cartridge Type Single Pilot Operated Check Valves • Integrated Hydraulics 4CK300 Series • To 5000 PSI &
80 GPM
Catalog Special
Part No. Eaton Part No. Eaton Model Cracking Pressure (psi) Seal Material Features Wt. Price Each
Miscellaneous Products

C1MG45 401AA00010A 4CK3001S3 29 Niltrile Pilot Seal 0.62


Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
244
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Pilot Operated Check Valves

Hydraulic Power & Control


Cartridge Type Dual Pilot Operated Check Valves with Thermal
Relief
Integrated Hydraulics 4CKKT Series • To 4350 PSI & 6.6 GPM

Pneumatic Power & Control


Features: Hardened and ground poppet gives excellent flow capability for valve size, positive sealing and long
working life. Cartridge construction allows installation in actuators, manifold blocks and Hydraulic Integrated
Circuits. Requires a machined C-10-4 cavity or housing for installation.
Application: Pilot check valves allow flow to pass in one direction, with a low pressure drop, then prevent reverse
flow until pilot pressure is applied. There are many applications for this valve type, the most common being to
lock and hold a cylinder, or another hydraulic actuator, in position. A pilot relief valve will protect the cylinder and

Fluid Conveying
hoses from thermal expansion of the hydraulic fluid. See Introduction to Pilot-Operated Check Valves (Lock
Valves) at the beginning of this section.
Specifications: 6.6 gpm rated flow. 4350 psi maximum setting. CAUTION: Pressures over 3000 psi require a
steel housing. -22° to +194°F operating temperature range. 5 drops per minute max internal leakage between
ports 1 and 2. 15 drops per minute max internal leakage between ports 3 and 4. Based on oil temperature of
104°F and 150 SSU.
Recommended Filtration Level: ISO level 18/13 or better.
Installation: 22 ft-lbs torque cartridge into cavity. Unrestricted mounting position. For compatible C-10-4 bodies

Miscellaneous Products
see page 413
Cartridge Type Dual Pilot Operated Check Valves with Thermal Relief • Integrated Hydraulics 4CKKT
Series • To 4350 PSI & 6.6 GPM
Integrated Integrated
Catalog Hydraulics Part Hydraulics Pressure Setting Seal Price
Part No. No. Model Pilot Ratio (psi) Pilot Seal Body Material Wt. Each
C1JZ75 401AA00011A 4CKKT503S328 3:1 4000 Standard None Nitrile 0.18

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
245
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Pilot Operated Check Valves
Hydraulic Power & Control

Inline Double Pilot Operated Check Valves


Vickers® DPC1-10 Series • To 3000 PSI & 12 GPM
Pneumatic Power & Control
Fluid Conveying

Application & Operation: See Introduction to Pilot-Operated Check Valves (Lock Valves) at the beginning of this
Miscellaneous Products

section.
Ratio of Pilot Piston Area to Check Valve Seat Area: 4:1.
Rated Flow: 12 GPM.
Maximum Operating Pressure: 3000 PSI.
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration Level: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cracking Pressure: 15 PSI
Inline Double Pilot Operated Check Valves • Vickers® DPC1-10 Series • To 3000 PSI & 12 GPM
Catalog Seal Price
Part No. Vickers Part No. Vickers Model Port Size Pilot Piston Seal Material Wt. Each
Indexes & Technical Information

•C1BT61 566314 DPC1-10-P-6T SAE-6 No Buna-N 1.58


Note: These valves are sold as a complete assembly.

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
246
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Counterbalance Valves (Overcenter Valves)

Hydraulic Power & Control


Introduction to Counterbalance Valves (Overcenter Valves)
Overview: There are now many types of overcenter or counterbalance valves available to the designer of
hydraulically operated machines, each one has its own place and specific benefits to the user. The function of
these valves can be divided into three basic groups. 1. Load Holding; where the overcenter valve prevents the
movement of a load when the directional valve is in the neutral position. Permitting the use of open center
directional valves and negating leakage past the spool of closed centre directional valves. 2. Load Control;
where the overcenter valve prevents the actuator running ahead of the pump due to the load induced energy
thereby eliminating cavitation in the actuator and loss of control. 3. Load Safety. In the case of hose failure an

Pneumatic Power & Control


overcenter valve mounted onto or into an actuator will prevent uncontrolled movement of the load. When a boom
is used as a crane then hose failure protection is vital as the loss of load control could cause damage to people
or property. Each of these functions is applicable to linear or rotary motion.

Application: Overcenter valves give static and dynamic control of loads by regulating the flow into and out of
hydraulic actuators. When installed close to or within an actuator, the overcenter valve will stop runaway in the
event of hose burst and if open center directional control valves are used, will allow thermal expansion relief of
the hydraulic fluid. The overcenter cartridge is ideal for mounting directly into a cavity machined in the body of
the cylinder, motor or rotary actuator. The cartridge can also be mounted directly to the ports via a specifically
machined body as part of an integrated circuit or single unit, or contained within one of the standard line bodies.
Single overcenter valves are normally used when the load is unidirectional, for example an aerial platform or
crane and dual overcenter valves are used for controlling loads in both directions for motor applications or for
cylinders going over center.

Fluid Conveying
Back Pressure: Overcenter valves should not be subjected to back pressure, as this will affect performance and
can cause unstable operation. If back pressure cannot be avoided, as an option, a vented spring cavity design
should be selected.

Operation: The standard overcenter valve can be described as a pilot assisted relief valve with an integral free
flow check. The difference between this design of valve and a pilot check is that the check valve will open fully
as soon as the pilot pressure is sufficient to open the valve because the only resistance to opening is the

Miscellaneous Products
pressure locked in to the cylinder port. With an overcenter valve the pilot pressure has to overcome the force of
the spring which is reduced by load pressure. This ensures a gradual opening and a metering of the flow as it
passes the poppet. Overcenter valves consist of a poppet that seals flow from an actuator, a check element,
which permits free flow to the actuator and a pilot section that opens the poppet allowing flow from the actuator
at a controlled rate.

Pilot Ratios: Generally, lower pilot ratios consume more energy for load control but provide more stability. Pilot
ratios should then be selected to give good controlability with a minimum of energy loss. Overcenter valves are
available with various pilot ratios.

Equal Area Valves: The equal area valve is used when pilot pressure must be set independent of any Indexes & Technical Information
load-induced pressure, such as on a winch with a brake, where brake release pressure must be obtained before
motion is allowed.

Pilot Pressure Formula: The check section allows free flow into the actuator then holds and locks the load
against movement. The pilot assisted relief valve section will give controlled movement when pilot pressure is
applied. For most applications the relief setting should be approximately 1.3 times higher than the maximum
load induced pressure. This ensures that with the maximum load on the actuator the valve will remain closed
until pilot pressure is applied. The pilot pressure required to open the valve will depend on the pilot ratio that is
the ratio between the relief area and the pilot area. The pilot pressure can be calculated: Pilot pressure = (Valve
Setting - Load Pressure)/Pilot Ratio. Example: Valve Setting is 4000 PSI. Load Pressure is 1000 PSI. Valve
Ratio is 3:1. Pilot Pressure = (4000-1000)/3, resulting in 1000 PSI required to start to move the load.

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
247
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Counterbalance Valves (Overcenter Valves)
Hydraulic Power & Control

Important Holding Valve Basics: Apply in circuits to prevent loads from dropping faster than input flow would
allow • Use on the outlet of the controlled device (meter out) • Always follow catalog recommendations and
application directions • Consult with our representative or the factory when in doubt • NEVER apply a holding
valve with a an unequal area to outriggers or stabilizers • Do not expect motors to hold without mechanical
gearing or brakes. Motors have internal clearances which will allow rotation to occur even when the overcenter
valve does not leak • When applying overcenter valves to life carrying machines such as boom/utility type
equipment, do not separate the valve from the actuator... close-couple the valve to the actuator • Care should be
taken to ensure the load is supported by mechanical means when servicing or removing the valve (CAUTION:
When servicing the equipment, trapped pressure may be present in the overcenter valve circuit. Carefully bleed
down the trapped pressure before disassembly) • When rebuilding machinery, you should replace rather than
Pneumatic Power & Control

repair the overcenter valve • The cylinder and it's seals must be in good condition.

Cartridge Type Counterbalance Valves


Integrated Hydraulics 1CE20 Series • To 5000 PSI & 5 GPM
Fluid Conveying

Features: The 1CE20 is a 3 port, externally piloted, screw-in cartridge-type counterbalance (overcenter) valve.
Requires a machined A22903 cavity or housing for installation.
Miscellaneous Products

Application: To control moving loads and prevent load runaway, giving load holding and hose failure safety. See
Introduction to Counterbalance (Overcenter) Valves at the beginning of this section.
Pilot Ratios: 3:1 - Best suited for extremely unstable applications such as long booms or flexible frameworks.
4.5:1 - Best suited for applications where load varies and machine structure can induce instability.
8:1 - Best suited for applications where the load remains relatively constant.
Specifications: 5 gpm rated flow. 4000 psi max load induced pressure, 5000 psi max relief pressure. CAUTION:
Pressures over 3000 psi require a steel housing. -22° to +194°F operating temperature range. 5 drops per
minute max internal leakage. Based on oil temperature of 104°F and 150 SSU.
Recommended Filtration Level: ISO level 18/13 or better.
Installation: 30 ft-lbs torque cartridge into cavity. Unrestricted mounting position.
Indexes & Technical Information

Housing: Cavity size A22903, sold separately. For single valve housings, see page 411 For dual valve housings,
see page 412
Cartridge Type Counterbalance Valves • Integrated Hydraulics 1CE20 Series • To 5000 PSI & 5 GPM
Integrated Factory
Catalog Hydraulics Part Integrated Hydraulics Pilot Adjustment Pressure Setting Seal Price
Part No. No. Model Ratio Means Range (PSI) (psi) Body Material Wt. Each

Screw with None


C1JZ78 406AA00002A 1CE20F35S4 4.5:1 2900-5075 3045 (Select Nitrile 0.35
Locknut below)

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
248
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Counterbalance Valves (Overcenter Valves)

Hydraulic Power & Control


Cartridge Type Counterbalance Valves
Integrated Hydraulics 1CE30 Series • To 5000 PSI & 8 GPM

Pneumatic Power & Control


Features: The 1CE30 is a 3 port, externally piloted, screw-in cartridge-type counterbalance (overcenter) valve.
Requires a machined A6610 cavity or housing for installation.
Application: To control moving loads and prevent load runaway, giving load holding and hose failure safety. See
Introduction to Counterbalance (Overcenter) Valves at the beginning of this section.
Pilot Ratios: 2.5:1 - Best suited for extremely unstable applications such as long booms or flexible frameworks.
5:1 - (standard) Best suited for applications where load varies and machine structure can induce instability.
10:1 - Best suited for applications where the load remains relatively constant.

Fluid Conveying
Specifications: 8 gpm rated flow. 4000 psi max load induced pressure, 5000 psi max relief pressure. CAUTION:
Pressures over 3000 psi require a steel housing. -22° to +194°F operating temperature range. 5 drops per
minute max internal leakage. Based on oil temperature of 104°F and 150 SSU.
Recommended Filtration Level: ISO level 18/13 or better.
Installation: 33 ft-lbs torque cartridge into cavity. Unrestricted mounting position.
Housings: Single valve housings, see page 411 Dual valve housings, see page 412
Cartridge Type Counterbalance Valves • Integrated Hydraulics 1CE30 Series • To 5000 PSI & 8 GPM
Integrated Factory

Miscellaneous Products
Catalog Hydraulics Part Integrated Hydraulics Pilot Adjustment Pressure Setting Seal Price
Part No. No. Model Ratio Means Range (PSI) (psi) Body Material Wt. Each
Screw with
C1MG50 406AA00004A 1CE30F35S2 2.5:1 Locknut 1740-5075 3045 None Nitrile 0.33

C1JZ79 406AA00005A 1CE30F35S5 5:1 Screw with 1740-5075 3045 None Nitrile 0.41
Locknut
C1JZ80 406AA00006A 1CE30F35S10 10:1 Screw with 1740-5075 3045 None Nitrile 0.40
Locknut

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
249
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Counterbalance Valves (Overcenter Valves)
Hydraulic Power & Control

Cartridge Type Counterbalance Valves


Integrated Hydraulics 1CEB30 Series • To 4000 PSI & 8 GPM
Pneumatic Power & Control

Features: The 1CEB30 is a 3 port, externally piloted, pressure balanced screw-in cartridge-type counterbalance
(overcenter) valve. Requires a machined A6610 cavity or housing for installation.
Application: The pressure balanced valve is unaffected by back pressure, allowing service line reliefs to operate
and for the valve to be used in regenerative or proportional valve systems.
Pilot Ratio: 5:1 - (standard) Best suited for applications where load varies and machine structure can induce
instability.
Fluid Conveying

Specifications: 8 gpm rated flow. 4000 psi max load induced pressure, 4350 psi max relief pressure. CAUTION:
Pressures over 3000 psi require a steel housing. -22° to +194°F operating temperature range. 5 drops per
minute max internal leakage. Based on oil temperature of 104°F and 150 SSU.
Recommended Filtration Level: ISO level 18/13 or better.
Installation: 33 ft-lbs torque cartridge into cavity. Unrestricted mounting position.
Cartridge: Model 1CEB30, sold separately.
Housing: A6610 cavity, sold separately. For single valve housings, see page 411 For dual valve housings, see
page 412
Miscellaneous Products

Cartridge Type Counterbalance Valves • Integrated Hydraulics 1CEB30 Series • To 4000 PSI & 8 GPM
Integrated Integrated Pre-Set
Catalog Hydraulics Part Hydraulics Control Adjustment Adjustment Pressure
Part No. No. Model Ratio Style Range (psi) (psi) Housing Seal Material Wt. Price Each
C1MG51 406AA00010A 1CEB30F35S5 5:1 Screw 1450-5076 3045 None Nitrile 0.30
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
250
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Counterbalance Valves (Overcenter Valves)

Hydraulic Power & Control


Cartridge Type Counterbalance Valves
Integrated Hydraulics 1CEV30 Series • To 4000 PSI & 8 GPM

Pneumatic Power & Control


Features: The 1CEV30 is a 3 port, externally piloted, pressure balanced screw-in cartridge-type counterbalance
(overcenter) valve. Requires a machined C-10-3S cavity or housing for installation.
Application: The pressure balanced valve is unaffected by back pressure, allowing service line reliefs to operate
and for the valve to be used in regenerative or proportional valve systems.
Pilot Ratio: 5:1 - (standard) Best suited for applications where load varies and machine structure can induce
instability. 7:1 - Best suited for applications where the load remains relatively constant.

Fluid Conveying
Specifications: 8 gpm rated flow. 3000 psi max load induced pressure, 4000 psi max relief pressure. CAUTION:
Pressures over 3000 psi require a steel housing. -22° to +194°F operating temperature range. 5 drops per
minute max internal leakage. Based on oil temperature of 104°F and 150 SSU.
Recommended Filtration Level: ISO level 18/13 or better.
Installation: 33 ft-lbs torque cartridge into cavity. Unrestricted mounting position.
Cartridge: Model 1CEV30-*, sold separately.
Housing: C-10-3S cavity, sold separately. For single valve housings, see page 411 For dual valve housings, see
page 412

Miscellaneous Products
Cartridge Type Counterbalance Valves • Integrated Hydraulics 1CEV30 Series • To 4000 PSI & 8 GPM
Integrated Pre-Set
Catalog Hydraulics Part Integrated Control Adjustment Adjustment Pressure Price
Part No. No. Hydraulics Model Ratio Style Range (psi) (psi) Housing Seal Material Wt. Each

C1MG52 406AA02901A 1CEV30-F-30S-5 5:1 Screw 1000-3000 2030 None Viton 0.30

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
251
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Counterbalance Valves (Overcenter Valves)
Hydraulic Power & Control

Cartridge Type Counterbalance Valves


Integrated Hydraulics 1SE30 Series • To 5000 PSI & 8 GPM
Pneumatic Power & Control

Features: The 1SE30 is a 3 port, externally piloted, screw-in cartridge-type counterbalance (overcenter) valve.
Requires a machined T11A Sun cavity or housing for installation.
Application: To control moving loads and prevent load runaway, giving load holding and hose failure safety. See
Introduction to Counterbalance (Overcenter) Valves at the beginning of this section.
Pilot Ratios: 2.5:1 - Best suited for extremely unstable applications such as long booms or flexible frameworks.
5:1 - (standard) Best suited for applications where load varies and machine structure can induce instability.
10:1 - Best suited for applications where the load remains relatively constant.
Fluid Conveying

Specifications: 8 gpm rated flow. 4000 psi max load induced pressure, 5000 psi max relief pressure. CAUTION:
Pressures over 3000 psi require a steel housing. -22° to +194°F operating temperature range. 5 drops per
minute max internal leakage. Based on oil temperature of 104°F and 150 SSU.
Recommended Filtration Level: ISO level 18/13 or better.
Installation: 33 ft-lbs torque cartridge into cavity. Unrestricted mounting position.
Cartridge Type Counterbalance Valves • Integrated Hydraulics 1SE30 Series • To 5000 PSI & 8 GPM
Integrated Factory
Catalog Hydraulics Part Integrated Hydraulics Pilot Adjustment Pressure Setting Seal Price
Miscellaneous Products

Part No. No. Model Ratio Means Range (PSI) (psi) Body Material Wt. Each
Screw with
C1JZ83 406AA00049A 1SE30F35S5 5:1 Locknut 1015-5075 3045 None Nitrile 0.45
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
252
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Counterbalance Valves (Overcenter Valves)

Hydraulic Power & Control


Cartridge Type Counterbalance Valves
Integrated Hydraulics 1SEB30 Series • To 5000 PSI & 8 GPM

Pneumatic Power & Control


Features: The 1SEB30 is a 3 port, externally piloted, screw-in cartridge-type counterbalance (overcenter) valve
with a spring chamber vented to atmosphere. Requires a machined T11A Sun cavity or housing for installation.
Application: To control moving loads and prevent load runaway, giving load holding and hose failure safety. This
pressure balanced valve is unaffected by back pressure, allowing service line reliefs to operate and for the valve
to be used in regenerative or proportional valve systems. See Introduction to Counterbalance (Overcenter)
Valves at the beginning of this section.
Pilot Ratios: 5:1 - Best suited for applications where load varies and machine structure can induce instability.

Fluid Conveying
Specifications: 8 gpm rated flow. 4000 psi max load induced pressure, 5000 psi max relief pressure. CAUTION:
Pressures over 3000 psi require a steel housing. -22° to +194°F operating temperature range. 5 drops per
minute max internal leakage. Based on oil temperature of 104°F and 150 SSU.
Recommended Filtration Level: ISO level 18/13 or better.
Installation: 33 ft-lbs torque cartridge into cavity. Unrestricted mounting position.
Cartridge Type Counterbalance Valves • Integrated Hydraulics 1SEB30 Series • To 5000 PSI & 8 GPM
Integrated Factory
Catalog Hydraulics Part Integrated Hydraulics Pilot Adjustment Pressure Setting Seal Price

Miscellaneous Products
Part No. No. Model Ratio Means Range (PSI) (psi) Body Material Wt. Each
Screw with
C1JZ84 406AA00052A 1SEB30F35S5 5:1 Locknut 1087-5075 3045 None Nitrile 0.50

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
253
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Counterbalance Valves (Overcenter Valves)
Hydraulic Power & Control

Cartridge Type Counterbalance Valves


Vickers® CBV1/2-10 Series • To 5000 PSI & 15 GPM
Pneumatic Power & Control

Features: Cartridge style (Requires a machined cavity or housing for installation).


Application & Operation: See Introduction to Counterbalance Valves at the beginning of this section.
Pressure Rating: 5000 PSI (CAUTION: Pressures over 3000 PSI require steel housing).
Rated Flow: 15 GPM.
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration Level: ISO level 18/16/13 or cleaner.
Cartridge: Model CBV1-10*, sold separately.
Housing: Cavity size C-10-3S, sold separately. For single valve housings, see page 411 For dual valve
housings, see page 412
Fluid Conveying

Cartridge Type Counterbalance Valves • Vickers® CBV1/2-10 Series • To 5000 PSI & 15 GPM
Free Flow
Crack Pre-Set
Catalog Vickers Control Adjustment Pressure Adjustment Pressure Seal Price
Part No. Part No. Vickers Model Ratio Style (psi) Range (psi) (psi) Housing Material Wt. Each

Cap Over None


•C1AD25 02-171990 CBV1-10-C-0-A-30/ 4:1 20 900-3000 -- (Select Buna-N 0.53
Screw below)
Miscellaneous Products

Dual
Line-Moun
CBV1-10-S-DA10T-A-3 Screw with ted, Light
C1JU43 02-173219 0/ 4:1 Locknut 20 900-3000 -- Duty Buna-N 2.86
Aluminum,
SAE-10
Ports
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
254
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Counterbalance Valves (Overcenter Valves)

Hydraulic Power & Control


Cartridge Type Counterbalance Valves
Integrated Hydraulics 1SE90 Series • To 5000 PSI & 23 GPM

Pneumatic Power & Control


Features: The 1SE90 is a 3 port, externally piloted, screw-in cartridge-type counterbalance (overcenter) valve.
Requires a machined T2A Sun cavity or housing for installation.
Application: To control moving loads and prevent load runaway, giving load holding and hose failure safety. See
Introduction to Counterbalance (Overcenter) Valves at the beginning of this section.
Pilot Ratios: 4:1 - Best suited for applications where the load remains relatively constant.
Specifications: 23 gpm rated flow. 4000 psi max load induced pressure, 5000 psi max relief pressure. CAUTION:
Pressures over 3000 psi require a steel housing. -22° to +194°F operating temperature range. 5 drops per

Fluid Conveying
minute max internal leakage. Based on oil temperature of 104°F and 150 SSU.
Recommended Filtration Level: ISO level 18/13 or better.
Installation: 44 ft-lbs torque cartridge into cavity. Unrestricted mounting position.
Cartridge Type Counterbalance Valves • Integrated Hydraulics 1SE90 Series • To 5000 PSI & 23 GPM
Integrated Factory
Catalog Hydraulics Part Integrated Hydraulics Pilot Adjustment Pressure Setting Seal Price
Part No. No. Model Ratio Means Range (PSI) (psi) Body Material Wt. Each
Screw with
C1JZ85 406AA00054A 1SE90F35S4 4:1 Locknut 2537-5075 3045 None Nitrile 0.90

Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
255
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Counterbalance Valves (Overcenter Valves)
Hydraulic Power & Control

Cartridge Type Counterbalance Valves


Integrated Hydraulics 1SEB90 • To 4000 PSI & 23 GPM
Pneumatic Power & Control

Features: The 1SEB90 is a 3 port, externally piloted, screw-in cartridge-type counterbalance (overcenter) valve
Fluid Conveying

with a spring chamber vented to atmosphere. Requires a machined T2A Sun cavity or housing for installation.
Application: To control moving loads and prevent load runaway, giving load holding and hose failure safety. This
pressure balanced valve is unaffected by back pressure, allowing service line reliefs to operate and for the valve
to be used in regenerative or proportional valve systems. See Introduction to Counterbalance (Overcenter)
Valves at the beginning of this section.
Pilot Ratios: 4:1 Best suited for applications where the load remains relatively constant.
Pressure Rating: Max Relief Setting: 5000 PSI. Max Load Induced Pressure: 4000 PSI
Rated Flow: 23 GPM
Miscellaneous Products

Temperature Range: -22° to +194°F


Recommended Filtration Level: 18/13
Cartridge: Model 1SEB90, sold separately
Housing: A20092-T2A or Sun T2A, sold separately
Cartridge Type Counterbalance Valves • Integrated Hydraulics 1SEB90 • To 4000 PSI & 23 GPM
Pre-Set
Catalog Vickers Part Control Adjustment Adjustment Pressure Seal
Part No. No. Vickers Model Ratio Style Range (psi) (psi) Housing Material Wt. Price Each
C1LX28 406AA00056A 1SEB90F35S4 4:1 Screw 1088-5076 3046 None Nitrile 0.92
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
256
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Counterbalance Valves (Overcenter Valves)

Hydraulic Power & Control


Cartridge Type Counterbalance Valves
Integrated Hydraulics 1CE90 Series • To 4000 PSI & 23 GPM

Pneumatic Power & Control


Features: Overcenter valves give static and dynamic control of loads by regulating the flow into and out of
hydraulic actuators. The check section allows free flow into the actuator then holds and locks the load against
movement. The pilot assisted relief valve section will give controlled movement when pilot pressure is applied.
Application: Single overcenter valves are normally used when the load is unidirectional, for example an aerial
platform or crane and dual overcenter valves are used for controlling loads in both directional for motor

Fluid Conveying
applications or for cylinders going over center.
Pilot Ratios: 4:1 Best suited for applications where load varies and machine structure can induce instability. 8:1
Best suited for applications where the load remains relatively constant.
Pressure Rating: 5000 PSI (CAUTION: Pressures over 3000 PSI require steel housing)
Rated Flow: 23 GPM
Temperature Range: -22° to +194°F
Recommended Filtration Level: 18/13
Cartridge: Model 1CE90, sold separately

Miscellaneous Products
Housing: Cavity size A12336, sold separately
Cartridge Type Counterbalance Valves • Integrated Hydraulics 1CE90 Series • To 4000 PSI & 23 GPM
Integrated Integrated Pre-Set
Catalog Hydraulics Part Hydraulics Control Adjustment Adjustment Pressure
Part No. No. Model Ratio Style Range (psi) (psi) Housing Seal Material Wt. Price Each
C1LX27 406AA00016A 1CE90F35S4 4:1 Screw 2900-5076 3045 None Nitrile 0.63

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
257
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Counterbalance Valves (Overcenter Valves)
Hydraulic Power & Control

Cartridge Type Counterbalance Valves


Vickers® CBV1/2-12 Series • To 5000 PSI & 30 GPM
Pneumatic Power & Control

Features: The CBV*-12 is a 3 port, externally piloted, screw-in cartridge type counterbalance valve. Cartridge
style (Requires a machined cavity or housing for installation).
Fluid Conveying

Application & Operation: See Introduction to Counterbalance Valves at the beginning of this section. The
counterbalance valve allows free flow from port 2 to port 1. Flow from port 1 to port 2 is blocked until either the
predetermined pressure setting has been reached or sufficient pilot pressure has been applied to port 2 (pilot
port).
Pressure Rating: 5000 PSI (CAUTION: Pressures over 3000 PSI require steel housing).
Rated Flow: 30 GPM.
Temperature Range: -40°F to 248°F (Extreme Limits).
Miscellaneous Products

Recommended Filtration Level: ISO level 18/16/13 or cleaner.


Cartridge: Model CBV1/2-12*, sold separately.
Housing: Cavity size C-12-3S, sold separately, see page 411
Cartridge Type Counterbalance Valves • Vickers® CBV1/2-12 Series • To 5000 PSI & 30 GPM
Free Flow
Crack
Catalog Vickers Control Adjustment Pressure Adjustment Pre-Set Seal Price
Part No. Part No. Vickers Model Ratio Style (psi) Range (psi) Pressure Housing Material Wt. Each

C1FQ52 02-172086 CBV1-12-S-0-A-30/ 4:1 Screw with 25 900-3000 -- None Buna-N 0.79
Locknut
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
258
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Counterbalance Valves (Overcenter Valves)

Hydraulic Power & Control


Cartridge Type Counterbalance Valves
Integrated Hydraulics 1CE140 Series • To 6090 PSI & 37 GPM

Pneumatic Power & Control


Features: The 1CE140 is a 3 port, externally piloted, screw-in cartridge-type counterbalance (overcenter) valve.
Requires a machined A20081 cavity or housing for installation.
Application: To control moving loads and prevent load runaway, giving load holding and hose failure safety. See
Introduction to Counterbalance (Overcenter) Valves at the beginning of this section.
Pilot Ratios: 4:1 - Best suited for applications where load varies and machine structure can induce instability.
6:1 - Best suited for applications where the load remains relatively constant.
Specifications: 37 gpm rated flow. 4930 psi max load induced pressure, 6090 psi max relief pressure. CAUTION:

Fluid Conveying
Pressures over 3000 psi require a steel housing. -22° to +194°F operating temperature range. 5 drops per
minute max internal leakage. Based on oil temperature of 104°F and 150 SSU.
Recommended Filtration Level: ISO level 18/13 or better.
Installation: 110 ft-lbs torque cartridge into cavity. Unrestricted mounting position.
Housing: Cavity size A20081, sold separately. For single valve housings, see page 411 For dual valve housings,
see page 412
Cartridge Type Counterbalance Valves • Integrated Hydraulics 1CE140 Series • To 6090 PSI & 37 GPM
Integrated Factory

Miscellaneous Products
Catalog Hydraulics Part Integrated Hydraulics Pilot Adjustment Pressure Setting Seal Price
Part No. No. Model Ratio Means Range (PSI) (psi) Body Material Wt. Each
None
C1JZ81 406AA00026A 1CE140F30S4 4:1 Screw with 3190-4785 3915 (Select Nitrile 2.70
Locknut
below)

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
259
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Counterbalance Valves (Overcenter Valves)
Hydraulic Power & Control

Cartridge Type Counterbalance Valves


Integrated Hydraulics 1CE300 Series • To 5000 PSI & 80 GPM
Pneumatic Power & Control

Features: The 1CE300 is a 3 port, externally piloted, screw-in cartridge-type counterbalance (overcenter) valve.
Requires a machined A6935 cavity or housing for installation.
Application: To control moving loads and prevent load runaway, giving load holding and hose failure safety. See
Introduction to Counterbalance (Overcenter) Valves at the beginning of this section.
Pilot Ratios: 3:1 - Best suited for applications where load varies and machine structure can induce instability.
8:1 - Best suited for applications where the load remains relatively constant.
Specifications: 80 gpm rated flow. 4000 psi max load induced pressure, 5000 psi max relief pressure. CAUTION:
Fluid Conveying

Pressures over 3000 psi require a steel housing. -22° to +194°F operating temperature range. 60 drops per
minute max internal leakage. Based on oil temperature of 104°F and 150 SSU.
Recommended Filtration Level: ISO level 18/13 or better.
Installation: 110 ft-lbs torque cartridge into cavity. Unrestricted mounting position.
Housing: Cavity size A6935 sold separately. For single valve housings, see page 411 For dual valve housings,
see page 412
Cartridge Type Counterbalance Valves • Integrated Hydraulics 1CE300 Series • To 5000 PSI & 80 GPM
Integrated Factory
Miscellaneous Products

Catalog Hydraulics Part Integrated Hydraulics Pilot Adjustment Pressure Setting Seal Price
Part No. No. Model Ratio Means Range (PSI) (psi) Body Material Wt. Each
None
C1JZ82 406AA00031A 1CE300F35S3 3:1 Screw with 1015-5075 3045 (Select Nitrile 0.70
Locknut
below)
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
260
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Cushion Valves

Hydraulic Power & Control


Cushion Valves (Double Relief Valves)
Integrated Hydraulics 1CLLR50 Series • To 3500 PSI & 12 GPM

Pneumatic Power & Control


Features: Single cartridge relieving in both directions cutting down space requirements, giving full adjustment
through its range on both pressures at the same time. Requires a machined C-10-2 cavity or housing for
installation.
Application: To protect both lines in a circuit from over pressurization by relieving oil to the other line. Ideal for use
with motors or directional valves as a safety relief. Differential area, fast acting, poppet valve.
Specifications:
Recommended Filtration Level: ISO level 18/13 or better.

Fluid Conveying
Installation: 44 ft-lbs torque cartridge into cavity. Unrestricted mounting position. For compatible C-10-2 bodies
see page 410
Cushion Valves (Double Relief Valves) • Integrated Hydraulics 1CLLR50 Series • To 3500 PSI & 12 GPM
Integrated Factory
Catalog Hydraulics Part Integrated Pressure Setting Adjustment Seal Price
Part No. No. Hydraulics Model Range (PSI) (psi) Means Body Material Wt. Each
C1JZ86 407AA00013A 1CLLR50F25S 1100-2900 1740 Screw None Nitrile 0.50

Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
261
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Cushion Valves
Hydraulic Power & Control

Cushion Valves (Double Relief Valves)


Vickers® CRV-10 Series • To 3000 PSI & 20 GPM
Pneumatic Power & Control

Features: Components can be purchased separately, see Note below. Aluminum in-line type housing. Relief
cartridges can be removed from the housing without disturbing the plumbing.
Application: Cushion valves are used to provide pressure relief for bi-directional motors and cylinders. (For
cylinder applications, cylinder displacement must be equal in both directions for oil to relieve from one side to the
Fluid Conveying

other).
Rated Flow: 20 GPM.
Maximum Operating Pressure: 3000 PSI.
Re-Seat Pressure: 90% of cracking pressure.
Temperature Range: -40°F to 248°F (Extreme limits).
Recommended Filtration Level: ISO 4406 Cleanliness Level 18/16/13 or better.
Note: Components can be purchased separately. One (1) Housing, Two (2) Cartridges and Two (2) Seal Kits are
required to make the cushion valve assembly. For each cartridge, remove the standard back-up ring and install
Miscellaneous Products

two (2) half-thickness back-up rings, one on each side of o-ring.


Cushion Valves (Double Relief Valves) • Vickers® CRV-10 Series • To 3000 PSI & 20 GPM
Catalog Price
Part No. Vickers Part No. Vickers Model Description Wt. Each
Complete Assembly. Aluminum Housing with SAE-8 Ports, 2ea Relief
C1JR22 02-178481 CRV-10-S-A8T-36/ Cartridges with 600-3600 PSI adjustment range (not for use above 3000 2.43
PSI in this application), Adjusting screw with locknut, Buna-N seals.
•C1CA63 889185 Aluminum Housing with SAE-8 Ports (1 required per assembly) 1.26
Relief Cartridge, 50-300 PSI adjustment range, Adjusting screw with
C1ET93 566688 RV3-10-S-0-3/ locknut, Buna-N seals (2 required per assembly) 0.51
Relief Cartridge, 600-3600 PSI adjustment range (not for use above 3000
•C1BT34 565568 RV3-10-S-0-36/ PSI in this application), Adjusting screw with locknut, Buna-N seals (2 0.53
Indexes & Technical Information

required per assembly)


C1FK22 565806 SK2-10-2 Buna-N Seal Kit (2 required per assembly) 0.01
Note: Components can be purchased separately. One (1) Housing, Two (2) Cartridges and Two (2) Seal Kits are required to make the cushion
valve assembly. For each cartridge, remove the standard back-up ring and install two (2) half-thickness back-up rings, one on each side of
o-ring.

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
262
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Cushion Valves

Hydraulic Power & Control


Cushion Valves (Double Relief Valves)
Cross Series RC • To 3000 PSI & 30 GPM

Pneumatic Power & Control


Features: Cartridge type hydraulically dampened poppet design. Quiet. Smaller differential between cracking
and full-flow pressures.
Application: Cross model RC Cushion Valves are designed to protect equal displacement cylinders or motors
from external or shock loads. Fluid which passes through one relief valve flows directly to the opposite side or
circuit of the valve, thus preventing cavitation of the cylinder or motor as a result of relief discharge. (For cylinder

Fluid Conveying
applications, cylinder displacement must be equal in both directions for oil to relieve from one side to the other).
Materials: High tensile gray iron housing. Hardened and ground steel poppet. Buna-N seals.
Maximum Flow Rate: 30 GPM Maximum.
Maximum Operating Pressure: 3000 PSI.
Cushion Valves (Double Relief Valves) • Cross Series RC • To 3000 PSI & 30 GPM
Catalog Adjustment Range Pressure Setting Price
Part No. Cross Model Port Size Adjustment Type (psi) (psi) Wt. Each
Screw Adjustment with
•C1DJ87 RC12BB 3/4 NPT 500-1500 1000 4.00

Miscellaneous Products
Acorn Nut

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
263
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Cushion Valves
Hydraulic Power & Control

Cushion Valves (Double Relief Valves)


Integrated Hydraulics 1CLLR100 Series • To 5000 PSI & 40 GPM
Pneumatic Power & Control

Features: Single cartridge relieving in both directions cutting down space requirements, giving full adjustment
through its range on both pressures at the same time. Requires a machined A878 cavity or housing for
installation.
Application: To protect both lines in a circuit from over pressurization by relieving oil to the other line. Ideal for use
with motors or directional valves as a safety relief. Differential area, fast acting, poppet valve.
Specifications: 40 gpm rated flow. 5000 psi maximum setting. CAUTION: Pressures over 3000 psi require a steel
housing. -22° to +194°F operating temperature range. 0.31 cubic inches per minute max internal leakage. Based
Fluid Conveying

on oil temperature of 104°F and 150 SSU. 12 gpm rated flow. 3500 psi maximum setting. CAUTION: Pressures
over 3000 psi require a steel housing. -22° to +194°F operating temperature range. 0.31 cubic inches per minute
max internal leakage. Based on oil temperature of 104°F and 150 SSU.
Recommended Filtration Level: ISO level 18/13 or better.
Installation: 44 ft-lbs torque cartridge into cavity. Unrestricted mounting position.
Housing: A878 cavity, sold separately, see page 411
Cushion Valves (Double Relief Valves) • Integrated Hydraulics 1CLLR100 Series • To 5000 PSI & 40 GPM
Integrated Factory
Miscellaneous Products

Catalog Hydraulics Part Integrated Pressure Setting Adjustment Seal Price


Part No. No. Hydraulics Model Range (PSI) (psi) Means Body Material Wt. Each
C1JZ87 407AA00014A 1CLLR100F35S 1650-5075 4060 Screw None Nitrile 0.52
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
264
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Manually Operated

Hydraulic Power & Control


2-Way 2-Position Pull-To-Open Manual Valves
Vickers® MPV1-10 Series • To 3000 PSI & 12 GPM
Features: Cartridge style (Requires a machined cavity or housing for installation). Pull-to-open
knob.
Application: For on-off control of a single stream of fluid. Pull-to-open. Release to close (spring
returns valve to closed).
Maximum Operating Pressure: 3000 PSI.
Rated Flow: 12 GPM.

Pneumatic Power & Control


Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration Level: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model MPV1-10*, sold separately.
Housing: Cavity size C-10-2, sold separately, see page 410

Fluid Conveying
Miscellaneous Products
2-Way 2-Position Pull-To-Open Manual Valves • Vickers® MPV1-10 Series • To 3000 PSI & 12 GPM
Catalog Price
Part No. Vickers Part No. Vickers Model Housing Seal Material Wt. Each
•C1BT36 565589 MPV1-10-K-0 None Buna-N 0.25

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
265
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Manually Operated
Hydraulic Power & Control

2-Way 2-Position Pull-To-Open Manual Valves


Integrated Hydraulics 3CP2 Series • To 3000 PSI & 4 GPM
Features: These cartridges permit a small regulated flow to pass when the hand knob is depressed.
Application: A typical application would be on an access platform to lower the boom in the event of
a power failure.
Maximum Operating Pressure: 3000 PSI.
Rated Flow: 0.9 mm orifice 1.4 US gpm, 1.5 mm orifice 4 US gpm.
Temperature Range: -22° to 194°F
Pneumatic Power & Control

Recommended Filtration Level: Cleanliness level 18/13 or better


Cartridge: Model 3CP2*, sold separately.
Housing: Cavity size A879, sold separately, see page 410
Fluid Conveying
Miscellaneous Products

2-Way 2-Position Pull-To-Open Manual Valves • Integrated Hydraulics 3CP2 Series • To 3000 PSI & 4 GPM
Catalog Price
Part No. Eaton Part No. Eaton Model Orifice Size (mm) Flow Rate (GPM) Housing Seals Wt. Each
C1MG46 401AA00053A 3CP2-1.5S 1.5 4 None Nitrile 0.11
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
266
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Manually Operated

Hydraulic Power & Control


Subplate/Manifold Mount NFPA Size D03 Manual Valves
Vickers® DG17V-3 Series • To 5000 PSI & 20 GPM
Features: Subplate mounted. Viton® seals standard.
Application: Compact high-pressure manual control valve for double acting cylinders
or reversible motors.
Maximum Flow Capacity: 20 GPM.
Maximum Operating Pressure: 5000 PSI Ports P, A and B. 100 PSI Port T
(Intermittent to 1450 PSI) (CAUTION: Need steel subplate or manifold for pressures

Pneumatic Power & Control


over 3000 PSI).
Recommended Filtration Level: ISO level 18/15 or cleaner.
Mounting Bolts: Standard mounting bolts are (4) 10-24 x 1-1/4 Grade 8 socket head capscrews (Vickers Bolt Kit
590716), torqued to 40-50 lb. in. See Bolt Kits on page 409
Size D03 Subplates & Manifolds: page 418

Fluid Conveying
Miscellaneous Products
Indexes & Technical Information

Subplate/Manifold Mount NFPA Size D03 Manual Valves • Vickers® DG17V-3 Series • To 5000 PSI & 20
GPM
Catalog Vickers Spool Price
Part No. Part No. Key Vickers Model Type Action Spool Type Other Features Wt. Each

C1AC70 02-135316 A DG17V-3-6C-60 4-way Spring In Center, P Blocked, A & B to 4.10


3-position Centered Tank

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
267
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Monoblock
Hydraulic Power & Control

1-2-3 Spool Monoblock Valves


Eaton 30900 Series • To 3000 PSI & 5 GPM
Features: Open Center Parallel Circuit design. Available in single spool, two spool and
three spool configurations. Available in a variety of spool types and spool actions.
Built-in load checks (not on Motor spools). Available with or without adjustable main relief
valve, standard setting 2000 PSI.
Application: For general mobile and industrial hydraulic applications. 3-way models
control a single acting cylinder or uni-directional motor. 4-way models control a double
Pneumatic Power & Control

acting cylinder or reversible hydraulic motor.


Materials: Cast iron bodies. Precision ground induction hardened spools with chrome plating on exposed ends.
Pressure Ratings: Rated Pressure: 3000 PSI. Maximum Inlet Pressure: 3500 PSI. Maximum Work Port
Pressure: 4500 PSI.
Flow Rating: 5 GPM.
Maximum System Temperature: 225°F.
Power Beyond: Body is bored for Power Beyond and is plugged. Valves can be converted to Power Beyond
(High Pressure Carryover) with an option kit (31900-321 for SAE-6, 31900-341 for SAE-8). This option allows
the installation of another valve downstream from the first valve. Hydraulic oil is available to the downstream
valve only when the spool in the upstream valve is in neutral. A separate tank line is required from each control
valve.
Closed Center: Valves can be converted to Closed Center with an option kit (31900-319).
Fluid Conveying

Dimensions & Technical Information: page 622


Miscellaneous Products

1-2-3 Spool Monoblock Valves • Eaton 30900 Series • To 3000 PSI & 5 GPM
Relief
Catalog Power Spool Setting Price
Part No. Eaton Model Spools Spool Type Beyond Work Ports Inlet Port Outlet Port Action (PSI) Wt. Each
4-way
•C1ES92 30922-DSC 2-Spool 3-position Plugged SAE-6 SAE-8 SAE-8 Spring 2000 6.23
Indexes & Technical Information

Tandem Centered
Center
Note: Handles are NOT included with valve, and are sold separately.

Parts & Accessories for Eaton 31900 Monoblock Directional Valves


Catalog Price
Part No. Part Number Description Wt. Each
•C1EV79 30950-901 Handle Kit 0.21

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
268
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Monoblock

Hydraulic Power & Control


1-Spool Monoblock Valves
Walvoil SD4 Series •To 3600 PSI & 12 GPM
Features: Simple, compact design, one-spool valve for open and closed center hydraulic
systems • Main pressure relief valve • Optional rotary and detent kick-out controls • Optional
cable control • Interchangeable spools.
Nominal Flow Rating: 12 GPM.
Maximum Operating Pressure: 3600 PSI.
Maximum Back Pressure: 360 PSI on outlet port T.

Pneumatic Power & Control


Internal Leakage A(B) to T: 0.18 in³/min at 1450 PSI differential pressure.
Fluid Temperature Range: -4°F to 176°F with standard Buna-N seals.
Ambient Temperature Range: -40°F to 140°F.
Viscosity: 80 to 400 SSU Operating, 70 SSU Minimum, 1950 SSU Maximum.
Maximum Level of Contamination: ISO 4406 19/16.
Note: Performance data measured with mineral oil of 215 SSU viscosity at 104°F.
Dimensions & Technical Information: page 638

Fluid Conveying
Miscellaneous Products
1-Spool Monoblock Valves • Walvoil SD4 Series •To 3600 PSI & 12 GPM
Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
Valve assy (SD4/1SV/68L-SAE), closed ctr, 4-way 3-pos, A & B closed in neutral,
•C1HV44 FVL101119018 (1) spring cent, no rlv. Rlv blanking plug (2), std lever box (5) does NOT include M8 thread 4.43 Indexes & Technical Information
handlever (II). SAE-8 ports P & T, SAE-6 ports A & B.
•C1HV78 XTAP623282 (2) Inlet relief valve blanking plug (Type SV) 0.60
•C1HV51 FVL5V11104000 (4) "A" side spool positioner (Type 11), with detent in positions 1, neutral and 2 0.26

•C1AL39 170011012 (II) Handlever (Type AL01/M8x120), for standard leverbox, M8 thread x 120mm long, with 0.10
black knob

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
269
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Monoblock
Hydraulic Power & Control

1 to 7 Spool Monoblock Valves


Walvoil SD5 Series •To 4600 PSI & 12 GPM
Features: Simple , compact and heavy duty designed monoblock valves from 1 to 7
sections for open and closed center hydraulic systems.• Fitted with a main pressure relief
valve and a load check valve. • Available with parallel, series or tandem circuit. • Optional
power beyond port (only for parallel or tandem circuit). • Diameter 0.63 inch
interchangeable spools. • A wide variety of service port valve options. • Actuation is
manual, pneumatic, electro-pneumatic, hydraulic, electro-hydraulic, with solenoid and
Pneumatic Power & Control

remote with flexible cables spool control kits.


Nominal Flow Rating: 12 GPM.
Maximum Operating Pressure: 4600 PSI (Parallel or Tandem circuit), 3600 PSI (Series
circuit).
Maximum Back Pressure: 360 PSI on outlet port T.
Internal Leakage A(B) to T: 0.18 in³/min at 1450 PSI differential pressure.
Fluid Temperature Range: -4°F to 176°F with standard Buna-N seals.
Ambient Temperature Range: -40°F to 140°F.
Viscosity: 80 to 400 SSU Operating, 70 SSU Minimum, 1950 SSU Maximum.
Maximum Level of Contamination: ISO 4406 19/16.
Note: Performance data measured with mineral oil of 215 SSU viscosity at 104°F.
Dimensions & Technical Information: page 639
Fluid Conveying
Miscellaneous Products
Indexes & Technical Information

1 to 7 Spool Monoblock Valves • Walvoil SD5 Series •To 4600 PSI & 12 GPM
Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each

SD51PKG328LAE Valve assy (SD5/1-P(KG3-120)/28L/AE-SAE), power beyond, 1-spool, 4-way 3-pos,


C1JG37 SAE (1) A&B open to tank in neutral, spring center, relief valve 900-2900 psi set 1750 psi, Std 8.16
FVL9510007 lever box (5) does NOT include M8 handlever (II). SAE-8 ports P,T,C, SAE-6 ports
A&B.
•C1HV78 XTAP623282 (2) Inlet relief valve blanking plug (Type SV) 0.60

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
270
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Monoblock

Hydraulic Power & Control


1 to 7 Spool Monoblock Valves • Walvoil SD5 Series •To 4600 PSI & 12 GPM
Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
"A" side spool positioner (Type 8ED3), On/Off electro-hydraulic, 12VDC (Requires 2ea
C1HU72 5V08105350 (4) solenoid connectors, needs external pilot and drain unless Collector Kit is used.) 3.40
Contact us for technical assistance with this option.
Handlever (Type AL01/M8x120), for standard leverbox, M8 thread x 120mm long, with
•C1AL39 170011012 (II) black knob 0.10

1 to 6 Spool Monoblock Valves

Pneumatic Power & Control


Walvoil SD11 Series •To 4600 PSI & 18 GPM
Features: Simple, compact and heavy duty designed monoblock valves from 1 to 6 spools for
open and closed center hydraulic systems • Main pressure relief valve and load check valve •
Available with parallel or series circuit • Optional power beyond port (for parallel circuit) •
Interchangeable spools • Wide variety of service ports and circuit valves • Spool control kits
for manual, pneumatic, hydraulic, electro-hydraulic and remote with flexible cable controls.
Nominal Flow Rating: 18 GPM.
Maximum Operating Pressure: 4600 PSI (Parallel circuit), 3600 PSI (Series circuit).
Maximum Back Pressure: 360 PSI on outlet port T.
Internal Leakage A(B) to T: 0.18 in³/min at 1450 PSI differential pressure.
Fluid Temperature Range: -4°F to 176°F with standard Buna-N seals.

Fluid Conveying
Ambient Temperature Range: -40°F to 140°F.
Viscosity: 80 to 400 SSU Operating, 70 SSU Minimum, 1950 SSU Maximum.
Maximum Level of Contamination: ISO 4406 19/16.
Note: Performance data measured with mineral oil of 215 SSU viscosity at 104°F.
Dimensions & Technical Information: page 642

Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
271
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Monoblock
Hydraulic Power & Control

1 to 6 Spool Monoblock Valves • Walvoil SD11 Series •To 4600 PSI & 18 GPM
Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
Valve assy (SD11/1-P(KG4-220)/18L/AET-SAE), open ctr 1-spool, parallel 4way3pos
•C1HX82 FVL104130102 (1) A&B closed in neutral spring cent. Dir press rlv (2) 2600-4600 PSI set 3200, std 13.70
leverbox (5) does NOT include M10 handlever (II). SAE-10 P & T (top outlet), SAE-8 A
& B.
Valve assy (SD11/1-P(KG3)/28L/AET-SAE), open ctr 1-spool, parallel 4way3pos A&B
open to tank in neutral, spring cent. Dir press rlv (2) 1150-2900 PSI set 1750, std
•C1HV54 FVL91110017 (1) leverbox (5) does NOT include M10 handlever (II). SAE-10 P & T (top outlet), SAE-8 A 13.59
& B.
Valve assy (SD11/2-P(KG3)/18Lx2/AET-SAE) , open ctr 2-spool, parallel 4way3pos
Pneumatic Power & Control

•C1HV45 FVL104219001 (1) A&B closed in neutral spring cent. Dir press rlv (2) 1150-2900 PSI set 1750, std 21.67
leverboxes (5) does NOT include M10 handlevers (II). SAE-10 P & T (top outlet),
SAE-8 A & B.
Valve assy (SD11/3-P(KG3)/18Lx3/AET-SAE), open ctr 3-spool, parallel 4way3pos
A&B closed in neutral spring cent. Dir press rlv (2) 1150-2900 PSI set 1750, std
•C1HV46 FVL104319004 (1) leverboxes (5) does NOT include M10 handlevers (II). SAE-10 P & T (top outlet), 28.80
SAE-8 A & B.
Direct pressure relief (Type YG3-175), 1800-3600 PSI range, standard setting 2500
•C1HT16 3XCAR110213 (2) PSI. 0.63
C1HZ84 3CU1425130 (3) Spool (Type 2), 4-way 3-position, A & B open to tank in neutral 0.76
•C1HV52 FVL5V11110000 (4) "A" side spool positioner (Type 11), with detent in positions 1, neutral and 2 0.56
•C1JC50 5V08110701 (4) "A" side spool positioner (Type 8P), On/Off pneumatic, NPT 1.41
•C1HT95 5LEV110000 (5) "B" side option (Type L), standard lever box, M10 thread (does NOT include M10 thread 0.49
handlever)
•C1HV50 FVL3XTAP532450 (6) Outlet port conversion option (Type AEK), closed center plug 0.32
Fluid Conveying

•C1HV49 FVL3XGIU532660 (6) Outlet port conversion option (Type AE), power beyond sleeve, SAE-10 0.38
•C1HQ47 170012020 (II) Handlever (Type AL01/M10x200), for standard leverbox, M10 thread x 200mm long, 0.28
with black knob
•C1HQ59 170013025 (II) Handlever (Type AL01/M12x250), for mechanical joystick, M12 thread x 250mm long, 0.50
with black knob
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
272
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Monoblock

Hydraulic Power & Control


1-Spool Monoblock Valves
Brand AO755 Series •To 3000 PSI & 18 GPM
Features: Small and compact. Positive metering in either direction. Precision ground
chrome plated spool for long life.
Application: AO755 manually operated valves provide metered flow to either work
port. Work port flow is directly proportional to the movement of the lever. The tank port
must go directly back to tank.
Materials: Cast iron body. Buna-N O-Rings. Chrome plated steel spool. Black nylon

Pneumatic Power & Control


ball knob.
Maximum Operating Pressure: 3000 PSI.
Nominal Flow Rating: 18 GPM.
Recommended Filtration: 30 Micron.
Dimensions & Technical Information: page 619

1-Spool Monoblock Valves • Brand AO755 Series •To 3000 PSI & 18 GPM Fluid Conveying
Miscellaneous Products
Indexes & Technical Information
Catalog Spool Spool Price
Part No. Brand Model Key Type Action Type Ports Other Features Wt. Each
4-way Spring Tandem 3/4NPT Inlet & Outlet
•C1EK85 AO755-T4-LS D 3-position Centered Center 1/2NPT Work Ports No Relief 5.24
4-way Tandem 3/4NPT Inlet & Outlet
•C1HE38 AO755-T4-LD F 3-position Detented Center 1/2NPT Work Ports No Relief 6.00

•C1HE39 AO755-T4-LRS G 4-way Spring Tandem 3/4NPT Inlet & Outlet Adjustable Relief (Set @ 6.06
3-position Centered Center 1/2NPT Work Ports 1500 PSI)

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
273
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Monoblock
Hydraulic Power & Control

1-Spool Monoblock Valves (Log Splitter Valves)


Brand LS755 Series •To 3000 PSI & 18 GPM
Features: Single Hydraulic Kick-Out designed primarily for log splitters. Small and
compact. Fine positive metering in either direction. Precision ground chrome plated
spool.
Application: Spring center hydraulic detent (SHA model) springs back to neutral from
one position and pressure release detent in the other direction when the cylinder
completes its return stroke. Hydraulic detent in both directions (HHA model, not
Pneumatic Power & Control

recommended for log splitters) pressure detent in both directions and springs to center
when out of detent.
Materials: Cast iron body. Buna-N O-Rings. Brass guide. Chrome plated steel spool.
Black nylon ball knob.
Maximum Operating Pressure: 3000 PSI.
Nominal Flow Rating: 18 GPM.
Recommended Filtration: 30 Micron.
Dimensions & Technical Information: page 619
Fluid Conveying
Miscellaneous Products

1-Spool Monoblock Valves (Log Splitter Valves) • Brand LS755 Series •To 3000 PSI & 18 GPM
Catalog Spool Spool Price
Part No. Brand Model Key Type Action Type Ports Other Features Wt. Each
Adjustable Relief (Set @
4-way Log Splitter Tandem 3/4NPT Inlet & Outlet 2000 PSI), Adjustable
•C1ZU70 LS755T4JRSHA A 3-position (See Center 1/2NPT Work Ports Kick-Out (Set @ 800 6.01
Below)
PSI)
Log Splitter Spool Action: Valve is spring centered in one direction (P to B) and has a hydraulic detent release in the other direction (P to A).
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
274
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Monoblock

Hydraulic Power & Control


1-Spool Monoblock Valves (With Pressure Comp. Flow Control)
Brand SDCF Series • To 3000 PSI & 18 GPM
Features: Full range pressure compensated bypass type flow control valve is built
in. Pilot operated relief valve is standard. Fine positive metering in either direction.
Precision ground chrome plated spool for long life.
Application: SDCF valves combine the features of a 4-way directional control
valve, a full range pressure compensated by-pass type flow control valve and a pilot
operated pressure relief valve all in one compact package. Flow to the work port is

Pneumatic Power & Control


directly proportional to the movement of the lever. Flow out of each work port is
constant regardless of load changes. The tank port must be plumbed directly back
to tank.
Materials: Cast iron body. Buna-N O-Rings. Chrome plated steel spool.
Maximum Operating Pressure: 3000 PSI.
Nominal Flow Rating: 18 GPM.
Recommended Filtration: 30 Micron.
Dimensions & Technical Information: page 620

Fluid Conveying
Miscellaneous Products
1-Spool Monoblock Valves (With Pressure Comp. Flow Control) • Brand SDCF Series • To 3000 PSI & 18
GPM
Flow
Catalog Spool Spool Range Other Price
Part No. Brand Model Key Type Action Type (GPM) Ports Features Wt. Each
Stainless
C1JD16 SDCF755TM12SLF1 A 4-way Friction Tandem 0-12 3/4NPT Inlet & Outlet Spool, 7.84
3-position Detent Center 1/2NPT Work Ports Adjustable
Relief
Stainless
4-way Spring Tandem 3/4NPT Inlet & Outlet Spool, Indexes & Technical Information
C1JD15 SDCF755TM124LSSS B 3-position Centered Center 0-12 1/2NPT Work Ports Adjustable 7.83
Relief

Option Kits & Parts for Brand SDCF Series Valves


Catalog Price
Part No. Part Number Description Wt. Each
•C1DK84 SDC-S Spring Centering Kit 0.37
C1JB77 SDC-F1 Ball Friction Detent Kit 0.63

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
275
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Proportional • NFPA Size D03 • ISO 4401 Size 03
Hydraulic Power & Control

Vickers KDG4V-3 & KDG4V-3S Series • Without Feedback

Vickers® KDG4V-3 & KDG4V-3S Proportional Valves Without Feedback


NFPA Size D03, ISO 4401 Size 03
Description: The primary function of these valves is to direct and meter fluid
flow in proportion to current received by the solenoid. This fluid flow controls
the velocity, direction and acceleration or deceleration of a cylinder or fluid
motor. The valve is controlled by applying current to the coil. This current
produces a force at the solenoid push pin which, in turn, causes spool travel.
The spool will continue it's motion until the solenoid force is balanced by the
Pneumatic Power & Control

return spring force.


Application: These valves are designed to fill the performance gap between conventional solenoid operated
directional valves and servo valves or feedback-type proportional valves. They provide control of spool position
and metered fluid flow in applications that don't require the high levels of accuracy, repeatability or response
possible with feedback-type proportional valves or servos.
Features: NFPA fatigue rated at 5000 PSI. Fully encapsulated solenoid coils. NEMA 4 rated junction box.
Standard Viton® seals.
Nominal Flow Rating: 5.8 GPM (72 PSI pressure drop P to A, 72 PSI pressure drop B to T).
Maximum Operating Pressure: 5000 PSI Ports P, A and B. (CAUTION: Pressures over 3000 PSI require steel
subplate or manifold). Port T: 1450 PSI for Standard Performance Valves, 3000 PSI for High Performance
Valves.
Operating Temperature Range: -4°F to 180°F.
Fluid Conveying

Fluid Viscosity Range: 75 to 250 SSU.


Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 for pressures to 3000 PSI; Level 17/15/12 for
pressures above 3000 PSI.
Note: Vickers publication 539 provides the additional technical information necessary for proper application of
these proportional valves. Contact us for application assistance or to request a copy of the Vickers publication.
Electronic Accessories (Amplifier Cards, Power Plugs): page 422
Size D03 Subplates & Manifolds: page 418
Solenoid Connectors: page 415 (Required for models that use DIN 43650 coils).
Miscellaneous Products

Mounting Bolts: Standard mounting bolts are (4) 10-24 x 1-1/4 Grade 8 socket head capscrews (Vickers Bolt Kit
590716 BK590716), torqued to 40-50 lb.in. with threads lubricated. See Bolts Kits on page 409

4-way, 3-position, Spring Centered


All Ports Blocked in Center
Spool Flow Rating: P to A or B to T Flow at 72 PSI Pressure Drop.
Coil Rating: Current Controlled models are for use with Power Plugs, Amplifier Cards or
Joystick Controllers in more demanding applications where current is varied across the
coil. Direct Voltage models are for use in less sophisticated and intermittent duty
Indexes & Technical Information

applications where voltage is varied across the coil.

4-way, 3-position, Spring Centered • All Ports Blocked in Center


Spool
Flow
Catalog Vickers Rating Metering Coil Price
Part No. Part No. Vickers Model (GPM) Condition Rating Coil Type Other Features Wt. Each

KDG4V-3S-2C08N- Meter In & 24VDC STD Performance, 1450 PSI


C1AD14 02-154277 H-M-U-H5-60 2.0 Meter Out Current DIN 43650 Port T, Waterproof Manual 5.00
Controlled Override
24VDC STD Performance, 1450 PSI
C1ER20 02-317856 KDG4V-3S-2C19N- 5.0 Meter In & Current DIN 43650 Port T, Waterproof Manual 4.89
H-M-U-H5-60 Meter Out Controlled Override

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
276
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Proportional • NFPA Size D03 • ISO 4401 Size 03

Hydraulic Power & Control


Vickers KDG4V-3 & KDG4V-3S Series • Without Feedback

4-way, 3-position, Spring Centered


Port P Blocked, Ports A & B Bleed to T in Center
Spool Flow Rating: P to A or B to T Flow at 72 PSI Pressure Drop.
Coil Rating: Current Controlled models are for use with Power Plugs, Amplifier Cards
or Joystick Controllers in more demanding applications where current is varied across
the coil. Direct Voltage models are for use in less sophisticated and intermittent duty
applications where voltage is varied across the coil.

Pneumatic Power & Control


4-way, 3-position, Spring Centered • Port P Blocked, Ports A & B Bleed to T in Center
Spool
Flow
Catalog Vickers Rating Metering Coil Price
Part No. Part No. Vickers Model (GPM) Condition Rating Coil Type Other Features Wt. Each
24VDC High Performance, 3000 PSI
C1JC47 02-311985 KDG4V-3-33C03F-H
-M-U-H7-60 0.8 Meter In Only Current DIN 43650 Port T, Waterproof Manual 5.27
Controlled Overrides

KDG4V-3S-33C08A- 24VDC STD Performance, 1450 PSI


C1AD15 02-154278 H-M-U-H5-60 2.0 Meter In Only Current DIN 43650 Port T, Waterproof Manual 5.00
Controlled Overrides
KDG4V-3S-33C22A- 12VDC STD Performance, 1450 PSI
C1HY30 02-148363 H-M-U-G5-60 5.8 Meter In Only Current DIN 43650 Port T, Waterproof Manual 5.00
-60 Controlled Overrides

Fluid Conveying
24VDC STD Performance, 1450 PSI
C1AD44 02-309901 KDG4V-3S-33C22A-
H-M-U-H5-60 5.8 Meter In Only Current DIN 43650 Port T, Waterproof Manual 5.00
Controlled Overrides

Vickers KDG4V-3 & KDG4V-3S Series Parts & Accessories

Miscellaneous Products
Vickers KDG4V-3 & KDG4V-3S Series Parts & Accessories
Catalog Price
Part No. Vickers Part No. Description Wt. Each

•C1BS52 5100-10900 DIN 43650 Solenoid Connector, Strain Relief Style for cable diameter 0.24 to 0.31, not wired, 0.25
no light
Indexes & Technical Information
•C1FK20 5103-1090000 DIN 43650 Solenoid Connector, Strain Relief Style for cable diameter 0.31 to 0.41, not wired, 0.05
light for 6-48 VAC/VDC 50/60 Hz

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
277
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Proportional • NFPA Size D03 • ISO 4401 Size 03
Hydraulic Power & Control

Vickers KFDG4V-3 Series • With Feedback

Vickers® KFDG4V-3 Proportional Valves With Feedback


NFPA Size D03, ISO 4401 Size 03
Description: The primary function of these valves is to direct and meter fluid
flow in proportion to current received by the solenoid. This fluid flow controls
the velocity, direction and acceleration or deceleration of a cylinder or fluid
motor. The valve is controlled by applying current to the coil. This current
produces a force at the solenoid push pin which, in turn, causes spool travel.
The spool will continue it's motion until the LVDT's feedback signal balances
Pneumatic Power & Control

with the input signal, ensuring accurate spool position control.


Application: These valves are designed to fill the performance gap between non-feedback type proportional
valves and servo valves. They provide control of spool position and metered fluid flow in applications that don't
require the highest levels of accuracy, repeatability or response possible with servo valves.
Features: Electronic feedback LVDT ensures accurate spool position control. Internal current feedback provides
optimal control. Standard Viton® seals.
Nominal Flow Rating: 5.8 GPM (72 PSI pressure drop P to A, 72 PSI pressure drop B to T).
Maximum Operating Pressure: 5000 PSI Ports P, A and B. (CAUTION: Pressures over 3000 PSI require steel
subplate or manifold). Port T: 1500 PSI. (Port L blocked by mounting surface).
Maximum Allowable Temperature Ranges: Ambient Air: 140°F. Fluid: 140°F.
Fluid Viscosity Range: 70-245 SSU Recommended, 70-2270 SSU Extreme.
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 for pressures to 3000 PSI; Level 17/15/12 for
Fluid Conveying

pressures above 3000 PSI.


Note: Vickers publication 5071.00/EN/0298/A provides the additional technical information necessary for proper
application of these proportional valves. Contact us for application assistance or to request a copy of the
Vickers publication.
Electronic Accessories (Amplifier Cards): page 422
Size D03 Subplates & Manifolds: page 418
Mounting Bolts: Standard mounting bolts are (4) 10-24 x 1-1/4 Grade 8 socket head capscrews (Vickers Bolt Kit
590716 BK590716), torqued to 40-50 lb.in. with threads lubricated. See Bolts Kits on page 409
Miscellaneous Products

4-way, 3-position, Spring Centered


All Ports Blocked in Center
Spool Flow Rating: P to A or B to T Flow at 72 PSI Pressure Drop.
Wiring Connectors: Solenoid coil and LVDT wiring connectors are included with
valve. Cable for solenoid coils can range from 0.24-0.40 inch diameter. Cable for
LVDT can range from 0.138-0.236 inch diameter.
4-way, 3-position, Spring Centered • All Ports Blocked in Center
Spool
Indexes & Technical Information

Flow
Catalog Vickers Rating Metering Coil Price
Part No. Part No. Vickers Model (GPM) Condition Rating Coil Type Other Features Wt. Each

KFDG4V-3-2C20N-Z Meter In & 24VDC 1500 PSI Port T, No Manual


C1BT19 565376 -M-U1-H7-20 5.28 Meter Out Amplifier DIN 43650 Override 6.35
Supplied

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
278
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center

Hydraulic Power & Control


Walvoil SD6 Series • Flows to 12 GPM (Nominal) • Pressures to 4600 PSI

Sectional Control Valves for Open & Closed Center Systems


Walvoil SD6 Series
Features: Simple, compact and heavy duty designed sectional valve from 1 to 12 sections, for
open and closed center hydraulic systems • Main pressure relief valve • Load check valve on
every work section • Available with parallel, tandem or series circuit • Optional power beyond
port • Available with manual, pneumatic, hydraulic, electro-hydraulic, solenoid or cable controls •
Interchangeable spools.
Nominal Flow Rating: 12 GPM.

Pneumatic Power & Control


Maximum Operating Pressure: 4600 PSI (Parallel or Tandem circuit). 3050 PSI (Series
circuit).
Maximum Back Pressure: 360 PSI on outlet port T.
Internal Leakage A(B) to T: 0.18 in³/min at 1450 PSI differential pressure.
Fluid Temperature Range: -4°F to 176°F with standard Buna-N seals.
Ambient Temperature Range: -40°F to 140°F.
Viscosity: 80 to 400 SSU Operating, 70 SSU Minimum, 1950 SSU Maximum.
Maximum Level of Contamination: ISO 4406 19/16.
Note: Performance data measured with mineral oil of 215 SSU viscosity at 104°F.
Dimensions & Technical Information: page 640

Fluid Conveying
Miscellaneous Products
SD6 Inlet Covers & Options

Indexes & Technical Information

SD6 Inlet Covers & Options


Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
Inlet cover (FE-SD6/AC(YG3)-SAE) with direct pressure relief (3) 1800-3600 PSI range
•C1HU98 612205001 (1) and standard setting 2500 PSI, with blanking plug (4). SAE-8 top inlet port P and 3.61
plugged SAE-8 end inlet.
•C1HV78 XTAP623282 (3) Inlet relief valve blanking plug (Type SV) 0.60

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
279
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center
Hydraulic Power & Control

Walvoil SD6 Series • Flows to 12 GPM (Nominal) • Pressures to 4600 PSI

SD6 Working Sections & Options


Pneumatic Power & Control
Fluid Conveying

SD6 Working Sections & Options


Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
Working section (EL-SD6/P-18L-SAE) , parallel circuit, 4-way 3-pos A & B closed in
•C1HU94 612105076 (1) neutral, complete with spring centering positioner (3), standard lever box (4) and 4.99
blanking plugs (5). SAE-6 work ports. Does NOT include M8 thread handlever.
Working section (EL-SD6/P-28L-SAE), parallel circuit, 4way3-pos A & B open to tank in
Miscellaneous Products

C1HU95 612105343 (1) neutral, complete with spring centering positioner (3), standard lever box (4) and 5.00
blanking plugs (5). SAE-6 work ports. Does NOT include M8 thread handlever.
"A" side spool positioner (Type 8ED3), On/Off electro-hydraulic, 12VDC (Requires 2ea
C1HU72 5V08105350 (3) solenoid connectors, 1ea Electro-Hydraulic Feeder Kit and Back Pressure Valve) 3.40
Handlever (Type AL01/M8x120), for standard leverbox, M8 thread x 120mm long, with
•C1AL39 170011012 (II) black knob 0.10
Handlever (Type AL01/M10x150), for optional leverbox, M10 thread x 150mm long,
•C1HN55 170012015 (II) with black knob 0.23

•C1HQ59 170013025 (II) Handlever (Type AL01/M12x250), for mechanical joystick, M12 thread x 250mm long, 0.50
with black knob
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
280
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center

Hydraulic Power & Control


Walvoil SD6 Series • Flows to 12 GPM (Nominal) • Pressures to 4600 PSI

SD6 Electro-Hydraulic Feeder Kits & Options

Pneumatic Power & Control


SD6 Electro-Hydraulic Feeder Kits & Options
Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
•C1HT30 4TAP413210 (3) G 1/4 plug for power beyond / closed center option (Type RE) 0.01

SD6 Outlet Cover & Options

Fluid Conveying
Miscellaneous Products
SD6 Outlet Cover & Options
Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each

•C1HV11 612305002 (1) Outlet cover (FS-SD6/RD-SAE) , SAE-8 top outlet port T, plugged SAE-8 end outlet, 2.89
machined for optional power beyond/closed center conversion
•C1HT30 4TAP413210 (3) G 1/4 plug for power beyond / closed center option 0.01

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
281
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center
Hydraulic Power & Control

Walvoil SD6 Series • Flows to 12 GPM (Nominal) • Pressures to 4600 PSI

SD6 Tie Rod & Mounting Bracket Kits


Pneumatic Power & Control

SD6 Tie Rod & Mounting Bracket Kits


Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
C1HU17 5TIR108155 (1) Tie rod kit for a 2-section valve assembly 0.46
C1HU20 5TIR108193 (1) Tie rod kit for a 3-section valve assembly 0.57
•C1HU22 5TIR108231 (1) Tie rod kit for a 4-section valve assembly 0.68
•C1HT99 5STA120160 (2) Brackets kit 0.52
Fluid Conveying
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
282
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center

Hydraulic Power & Control


Husco Model 5000 • Flows to 20 GPM (Nominal) • Pressures to 3000 PSI

Sectional Control Valves for Open & Closed Center Systems


Husco Model 5000
Features: 3000 psi operating pressure rating • Open-center or closed-center operation • Hard
chrome plated spools • Load check in each section • Single “low pressure” O-ring sealing
between sections • Precision spool with metering notches.
Options: High pressure carryover (Power Beyond) • Lock-out spool section (Built-in pilot
operated check valve section) • Mid-inlet flow combiner or separator • Left-hand spool sections •
Parallel, Conventional and Series circuitry • End mechanisms: Spring centered, Detent, 4th position float,

Pneumatic Power & Control


Hydraulic remote, Pneumatic remote, Automatic kick-out • Auxiliary valves: Pilot-operated, anti-cavitation check
combination relief cartridges, Anti-cavitation cartridges • Regenerative spools • Specialized spools.
Maximum Operating Pressure: 3000 PSI.
Maximum Outlet Port/Tank Core Pressure: 500 PSI.
Seals: Buna-N standard, Viton® optional.
Parallel Circuits: In a Parallel Circuit valve assembly, two or more spools may be actuated at the same time and
the oil will follow the path of least resistance. If the loads are different and the spools are fully shifted, the lightest
load will operate first. If the spools are not fully shifted and the oil is metered, it is possible to direct partial flow to
both loads.
Power Beyond & Closed Center Options: Valve assemblies can be made Power Beyond or Closed Center by
selecting and configuring the appropriate Outlet Cover.
Dimensions & Technical Information: page 623

Fluid Conveying
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
283
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center
Hydraulic Power & Control

Husco Model 5000 • Flows to 20 GPM (Nominal) • Pressures to 3000 PSI

Husco Model 5000 Sectional Valve Components


Pneumatic Power & Control

Husco Model 5000 Sectional Valve Components


Catalog Price
Part No. Husco Model Key Description Wt. Each
Pilot-Operated Main Relief Valve, 1500-3500 PSI Adjustment Range, Set at 2000 PSI
C1JP54 N5060-P/2000/5 (2) @ 5 GPM, has Anti-Cav Check 3.80
Spool Section (Std Parallel Circuit), Cylinder Spool, 4-way 3-position spring-centered,
Fluid Conveying

C1JP46 N5002-A1 (3) SAE-8 Work Ports, without Auxiliary Valve Ports. Requires 1ea Item (6) 5.10

C1JP54 N5060-P/2000/5 (4) Work Port Relief Valve with Anti-Cav Check, Pilot-Operated, 1500-3500 PSI 3.80
Adjustment Range, Set at 2000 PSI @ 5 GPM
C1JN40 B11-100 (5) 3-Position Detent Kit for Std Parallel Spool Sections 0.25
C1JP56 N52250-1 (6) Lever Kit, Fixed Position, Vertical 0.83

C1JP54 N5060-P/2000/5 (8) Pilot-Operated Power Beyond Relief Valve, 1500-3500 PSI Adjustment Range, Set at 3.80
2000 PSI @ 5 GPM, has Anti-Cav Check
(1) Inlet & Inlet/Outlet Cover: One is required.
(2) Main Relief Option: One is required if Inlet/Outlet Cover is used.
Miscellaneous Products

(3) Spool Section: One or more is required.


(4) Work Port Option: Two are required for each Spool Section that has Auxiliary Valve Porting.
(5) End Mechanism Option: Optional.
(6) Lever Kit: One is required for each manually operated spool section.
(7) Outlet Cover: One is required.
(8) Outlet Cover Option: A Shut-Off Plug is required for power beyond or closed center capability when Universal Outlet Cover is used.
(9) Tie Rod Kit: One is required. The Inlet & Outlet covers are NOT included in counting the number of sections for a tie rod kit. Final torque
the two 1/2" nuts to 14 ft-lb; Final torque the 9/16" nut to 33 ft-lb.
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
284
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center

Hydraulic Power & Control


Walvoil SD8 Series • Flows to 21 GPM (Nominal) • Pressures to 4600 PSI

Sectional Control Valves for Open & Closed Center Systems


Walvoil SD8 Series
Features: Simple, compact and heavy duty designed sectional valve from 1 to 12 sections,
for open and closed center hydraulic systems • Main pressure relief valve • Load check
valve on every work section • Available with parallel, tandem or series circuit • Optional
power beyond port • Available with manual, pneumatic, hydraulic, electro-hydraulic,
solenoid or cable controls • Interchangeable spools.
Nominal Flow Rating: 21 GPM.

Pneumatic Power & Control


Maximum Operating Pressure: 4600 PSI.
Maximum Back Pressure: 360 PSI on outlet port T.
Internal Leakage A(B) to T: 0.18 in³/min at 1450 PSI differential pressure.
Fluid Temperature Range: -4°F to 176°F with standard Buna-N seals.
Ambient Temperature Range: -40°F to 140°F.
Viscosity: 80 to 400 SSU Operating, 70 SSU Minimum, 1950 SSU Maximum.
Maximum Level of Contamination: ISO 4406 19/16.
Note: Performance data measured with mineral oil of 215 SSU viscosity at 104°F.
Dimensions & Technical Information: page 641

Fluid Conveying
SD8 Inlet Covers & Options

Miscellaneous Products
Indexes & Technical Information

SD8 Inlet Covers & Options


Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
Inlet cover (FE-SD8/AC(YG3)-SAE) with direct pressure relief (3) 900-2900 PSI range
•C1HV16 613205001 (1) and standard setting 1750 PSI, with blanking plug (4). SAE-10 end inlet port P and 4.93
plugged SAE-10 top inlet.

•C1HT16 3XCAR110213 (3) Direct pressure relief (Type YG3-175), 1800-3600 PSI range, standard setting 2500 0.63
PSI.

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
285
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center
Hydraulic Power & Control

Walvoil SD8 Series • Flows to 21 GPM (Nominal) • Pressures to 4600 PSI

SD8 Working Sections & Options


Pneumatic Power & Control
Fluid Conveying

SD8 Working Sections & Options


Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
Working section (EL-SD8/P-18L-SAE), parallel circuit, 4way 3pos A&B closed in
•C1HV13 613105001 (1) neutral, complete with spring centering positioner (3), standard lever box (4) and 7.01
blanking plugs (5). SAE-8 work ports. Does NOT include M10 thread handlever.
Miscellaneous Products

Working section (EL-SD8/P-28L-SAE), parallel circuit, 4way 3-pos A & B open to tank
•C1HV14 613105301 (1) in neutral, complete with spring centering positioner (3), standard lever box (4) and 6.97
blanking plugs (5). SAE-8 work ports. Does NOT include M10 thread handlever.
•C1HU84 5V11108000 (3) "A" side spool positioner (Type 11), with detent in positions 1, neutral and 2 0.50
"A" side spool positioner (Type 8ED3), On/Off electro-hydraulic, 12VDC (Requires 2ea
C1HU74 5V08108360 (3) solenoid connectors, 1ea Electro-Hydraulic Feeder Kit and Back Pressure Valve) 3.82
"B" side option (Type L), standard lever box, M10 thread (does NOT include M10
•C1HT94 5LEV108000 (4) thread handlever) 0.43
Handlever (Type AL01/M10x200), for standard leverbox, M10 thread x 200mm long,
•C1HQ47 170012020 (II) with black knob 0.28

•C1HQ59 170013025 (II) Handlever (Type AL01/M12x250), for mechanical joystick, M12 thread x 250mm long, 0.50
with black knob
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
286
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center

Hydraulic Power & Control


Walvoil SD8 Series • Flows to 21 GPM (Nominal) • Pressures to 4600 PSI

SD8 Electro-Hydraulic Feeder Kits & Options

Pneumatic Power & Control


SD8 Electro-Hydraulic Feeder Kits & Options
Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
•C1HT29 4TAP318010 (3) M18 x 1.5 plug for power beyond / closed center option 0.03

SD8 Outlet Cover & Options

Fluid Conveying
Miscellaneous Products
SD8 Outlet Cover & Options
Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each

•C1HV17 613305001 (1) Outlet cover (FS-SD8/RC-SAE), SAE-10 end outlet port T, plugged SAE-10 top outlet, 3.85
machined for optional power beyond/closed center conversion
•C1HT29 4TAP318010 (3) M18 x 1.5 plug for power beyond / closed center option 0.03

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
287
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center
Hydraulic Power & Control

Walvoil SD8 Series • Flows to 21 GPM (Nominal) • Pressures to 4600 PSI

SD8 Tie Rod & Mounting Bracket Kits


Pneumatic Power & Control

SD8 Tie Rod & Mounting Bracket Kits


Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
•C1HU16 5TIR108128 (1) Tie rod kit for a 1-section valve assembly 0.53
•C1HU18 5TIR108169 (1) Tie rod kit for a 2-section valve assembly 0.66
•C1HU21 5TIR108210 (1) Tie rod kit for a 3-section valve assembly 0.82
•C1HU24 5TIR108251 (1) Tie rod kit for a 4-section valve assembly 0.96
•C1HU27 5TIR108292 (1) Tie rod kit for a 5-section valve assembly 1.12
Fluid Conveying

•C1HU30 5TIR108333 (1) Tie rod kit for a 6-section valve assembly 1.26
•C1HU11 5STA125190 (2) Brackets kit 0.76
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
288
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center

Hydraulic Power & Control


Walvoil SDS150 Series • Flows to 24 GPM (Nominal) • Pressures to 4600 PSI

Sectional Control Valves for Open & Closed Center Systems


Walvoil SDS150 Series
Features: Simple, compact and heavy duty designed sectional valve from 1 to 12 sections,
for open and closed center hydraulic systems • Main pressure relief valve • Load check
valve on every work section • Available with parallel, tandem or series circuit • Optional
power beyond port • Available with manual, pneumatic, hydraulic, electro-hydraulic or cable
controls • Interchangeable spools.
Nominal Flow Rating: 24 GPM.

Pneumatic Power & Control


Maximum Operating Pressure: 4600 PSI (Parallel or Tandem circuit). 3050 PSI (Series
circuit).
Maximum Back Pressure: 360 PSI on outlet port T.
Internal Leakage A(B) to T: 0.18 in³/min at 1450 PSI differential pressure.
Fluid Temperature Range: -4°F to 176°F with standard Buna-N seals.
Ambient Temperature Range: -40°F to 140°F.
Viscosity: 80 to 400 SSU Operating, 70 SSU Minimum, 1950 SSU Maximum.
Maximum Level of Contamination: ISO 4406 19/16.
Note: Performance data measured with mineral oil of 215 SSU viscosity at 104°F.
Dimensions & Technical Information: page 645

Fluid Conveying
Miscellaneous Products
SDS150 Inlet Covers & Options

Indexes & Technical Information

SDS150 Inlet Covers & Options


Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
Inlet cover (FE-SDS150/AC(YG3)-SAE) with direct pressure relief (3): 1800-2900 PSI
C1HV21 614266002 (1) range and standard setting 1750 PSI, with blanking plug (4). SAE-12 end inlet port P 7.27
and plugged SAE-12 top inlet.
Direct pressure relief (Type YG3-175), 1800-3600 PSI range, standard setting 2500
•C1HT16 3XCAR110213 (3) PSI. 0.63

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
289
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center
Hydraulic Power & Control

Walvoil SDS150 Series • Flows to 24 GPM (Nominal) • Pressures to 4600 PSI

SDS150 Working Sections & Options


Pneumatic Power & Control
Fluid Conveying

SDS150 Working Sections & Options


Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
Working section (EL-SDS150/P-18L-SAE), parallel circuit, 4way 3-pos A&B closed in
Miscellaneous Products

C1HV19 614166001 (1) neutral, complete with spring centering positioner (3), standard lever box (4) and 10.05
blanking plugs (5). SAE-10 work ports. Does NOT include M10 thread handlever.
Working section (EL-SDS150/P-28L-SAE), parallel circuit, 4way 3-pos A&B open to
C1HV20 614166302 (1) tank in neutral, complete with spring centering positioner (3), standard lever box (4) and 10.02
blanking plugs (5). SAE-10 work ports. Does NOT include M10 thread handlever.
"A" side spool positioner (Type 8EI3), On/Off electro-hydraulic, 12VDC (Requires 2ea
C1JR83 5V08110320 (3) solenoid connectors, 1ea Electro-Hydraulic Feeder Kit and Back Pressure Valve) 4.50

•C1JC50 5V08110701 (3) "A" side spool positioner (Type 8P), On/Off pneumatic, NPT 1.41
"B" side option (Type L), standard lever box, M10 thread (does NOT include M10
•C1HT95 5LEV110000 (4) thread handlever) 0.49

•C1HQ47 170012020 (II) Handlever (Type AL01/M10x200), for standard leverbox, M10 thread x 200mm long, 0.28
with black knob
•C1HQ59 170013025 (II) Handlever (Type AL01/M12x250), for mechanical joystick, M12 thread x 250mm long, 0.50
Indexes & Technical Information

with black knob

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
290
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center

Hydraulic Power & Control


Walvoil SDS150 Series • Flows to 24 GPM (Nominal) • Pressures to 4600 PSI

SDS150 Electro-Hydraulic Feeder Kits & Options

Pneumatic Power & Control


SDS150 Electro-Hydraulic Feeder Kits & Options
Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
•C1HT29 4TAP318010 (3) M18 x 1.5 plug for power beyond / closed center option 0.03

SDS150 Outlet Cover & Options

Fluid Conveying
SDS150 Outlet Cover & Options

Miscellaneous Products
Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each

C1HV22 614366002 (1) Outlet cover (Type FS-SDS150/RC-SAE), SAE-12 end outlet port T, plugged SAE-12 4.12
top outlet, machined for optional power beyond/closed center conversion
•C1HT29 4TAP318010 (3) M18 x 1.5 plug for power beyond / closed center option 0.03

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
291
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center
Hydraulic Power & Control

Walvoil SDS150 Series • Flows to 24 GPM (Nominal) • Pressures to 4600 PSI

SDS150 Tie Rod & Mounting Bracket Kits


Pneumatic Power & Control

SDS150 Tie Rod & Mounting Bracket Kits


Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
C1HU38 5TIR110149 (1) Tie rod kit for a 1-section valve assembly 0.23
C1HU41 5TIR110194 (1) Tie rod kit for a 2-section valve assembly 1.34
C1HU54 5TIR110374 (1) Tie rod kit for a 6-section valve assembly 2.33
•C1HU11 5STA125190 (2) Brackets kit 0.76
Fluid Conveying
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
292
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center

Hydraulic Power & Control


Husco Model 6000 • Flows to 40 GPM (Nominal) • Pressures to 3400 PSI

Sectional Control Valves for Open & Closed Center Systems


Husco Model 6000
Features: Low effort spools • Zero leak spool seals • Open center or closed center operation •
Hard chrome plated spools • Load check in each section • Single low pressure o-ring sealing
between sections • Precision metering.
Options: High pressure carryover (Power Beyond) • Lock-out spool section (Built-in pilot
operated check valve section) • Mid-inlet flow combiner or separator • Left-hand spool sections •
Parallel, Conventional and Series circuitry • End mechanisms: Spring centered, Detent, 4th position float,

Pneumatic Power & Control


Hydraulic pilot operated, Automatic kick-out, Magnetic detent • Auxiliary valves: Pilot-operated, anti-cavitation
check combination relief cartridges, Anti-cavitation cartridges • Regenerative spools • Specialized spools.
Maximum Operating Pressure: 3400 PSI.
Maximum Outlet Port/Tank Core Pressure: 250 PSI.
Seals: Buna-N standard, Viton® optional.
Parallel Circuits: In a Parallel Circuit valve assembly, two or more spools may be actuated at the same time and
the oil will follow the path of least resistance. If the loads are different and the spools are fully shifted, the lightest
load will operate first. If the spools are not fully shifted and the oil is metered, it is possible to direct partial flow to
both loads.
Power Beyond & Closed Center Options: Valve assemblies can be made Power Beyond or Closed Center by
selecting and configuring the appropriate Outlet Cover.
Dimensions & Technical Information: page 624

Fluid Conveying
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
293
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center
Hydraulic Power & Control

Husco Model 6000 • Flows to 40 GPM (Nominal) • Pressures to 3400 PSI

Husco Model 6000 Sectional Valve Components


Pneumatic Power & Control

Husco Model 6000 Sectional Valve Components


Catalog Price
Part No. Husco Model Key Description Wt. Each
Pilot-Operated Main Relief Valve, 700-6000 PSI Adjustment Range, Set at 2000 PSI @
C1JP55 N51055-22/2000/5 (2) 5 GPM 1.50

C1JP55 N51055-22/2000/5 (4) Work Port Relief Valve, Pilot-Operated, 700-6000 PSI Adjustment Range, Set at 2000 1.50
PSI @ 5 GPM
C1JL48 N6105-A (6) Heavy Duty Lever Kit 2.01
(8) Pilot-Operated Power Beyond Relief Valve, 700-6000 PSI Adjustment Range, Set at
Fluid Conveying

C1JP55 N51055-22/2000/5 1.50


2000 PSI @ 5 GPM
(1) Inlet & Inlet/Outlet Cover: One is required.
(2) Main Relief Option: One is required if Inlet/Outlet Cover is used.
(3) Spool Section: One or more is required.
(4) Work Port Option: Two are required for each Spool Section that has Auxiliary Valve Porting.
(5) End Mechanism Option: Optional.
(6) Lever Kit: One is required for each manually operated spool section.
(7) Outlet Cover: One is required.
(8) Outlet Cover Option: A Shut-Off Plug is required for power beyond or closed center capability when Universal Outlet Cover is used.
Miscellaneous Products

(9) Tie Rod Kit: One is required. The Inlet & Outlet covers are NOT included in counting the number of sections for a tie rod kit. Final torque
the two 11/16" nuts to 48 ±5 ft-lb; Final torque the 3/4" nut to 74 ± 8 ft-lb.
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
294
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center

Hydraulic Power & Control


Walvoil SD16 Series • Flows to 37 GPM (Nominal) • Pressures to 4600 PSI

Sectional Control Valves for Open & Closed Center Systems


Walvoil SD16 Series
Features: Simple, compact and heavy duty designed sectional valve from 1 to 12 sections,
for open and closed center hydraulic systems • Main pressure relief valve • Load check
valve on every work section • Available with parallel, tandem or series circuit • Optional
power beyond port • Available with manual, pneumatic, hydraulic, electro-hydraulic or cable
controls • Interchangeable spools.
Nominal Flow Rating: 37 GPM.

Pneumatic Power & Control


Maximum Operating Pressure: 4600 PSI (Parallel or Tandem circuit). 3050 PSI (Series
circuit).
Maximum Back Pressure: 360 PSI on outlet port T.
Internal Leakage A(B) to T: 0.18 in³/min at 1450 PSI differential pressure.
Fluid Temperature Range: -4°F to 176°F with standard Buna-N seals.
Ambient Temperature Range: -40°F to 140°F.
Viscosity: 80 to 400 SSU Operating, 70 SSU Minimum, 1950 SSU Maximum.
Maximum Level of Contamination: ISO 4406 19/16.
Note: Performance data measured with mineral oil of 215 SSU viscosity at 104°F.
Dimensions & Technical Information: page 643

Fluid Conveying
Miscellaneous Products
SD16 Inlet Covers & Options

Indexes & Technical Information

SD16 Inlet Covers & Options


Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
Inlet cover (FE SD16/AC(XG-120)F-SAE) with pilot-operated pressure relief (3)
C1KK62 618205004 (1) 360-4600 PSI range and standard setting 1750 PSI, with anit-cavitation plug (4). 9.30
SAE-16 side inlet port P and plugged SAE-16 top inlet.

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
295
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center
Hydraulic Power & Control

Walvoil SD16 Series • Flows to 37 GPM (Nominal) • Pressures to 4600 PSI


SD16 Inlet Covers & Options
Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
Inlet cover (FE-SD16/AD(YG3)-SAE) with direct pressure relief (3) 1800-3600 PSI
•C1KK61 618205001 (1) range and standard setting 2500 PSI, with blanking plug (4). SAE-16 top inlet port P 9.50
and plugged SAE-16 end inlet.
C1HV70 XGIU641250 (2) Inlet port option, gauge port plug, SAE-16 x 1/4-19 BSPP 0.39

SD16 Working Sections & Options


Pneumatic Power & Control
Fluid Conveying
Miscellaneous Products

SD16 Working Sections & Options


Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
Working section (EL-SD16/P-18L-SAE), parallel circuit, 4way 3pos A&B closed in
•C1KK60 618105004 (1) neutral, complete with spring centering positioner (3), standard lever box (4) and 12.43
blanking plugs (5). SAE-12 work ports. Does NOT include M10 thread handlever.
Indexes & Technical Information

Working section (EL-SD16/P-28L-SAE), parallel circuit, 4way 3-pos A&B open to tank
•C1KK59 618101006 (1) in neutral, complete with spring centering positioner (3), standard lever box (4) and 12.43
blanking plugs (5). SAE-12 work ports. Does NOT include M10 thread handlever.
•C1JC50 5V08110701 (3) "A" side spool positioner (Type 8P), On/Off pneumatic, NPT 1.41
•C1HT95 5LEV110000 (4) "B" side option (Type L), standard lever box, M10 thread (does NOT include M10 thread 0.49
handlever)

C1KN76 X011411100 Port relief option (Type U(G3-100)), anti-shock & anti-cavitation valve, 1450-3600 PSI
(5) range, 0.40
standard setting 1450 PSI
Handlever (Type AL01/M10x200), for standard leverbox, M10 thread x 200mm long,
•C1HQ47 170012020 (II) with black knob 0.28
Handlever (Type AL01/M12x250), for mechanical joystick, M12 thread x 250mm long,
•C1HQ59 170013025 (II) with black knob 0.50

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
296
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center

Hydraulic Power & Control


Walvoil SD16 Series • Flows to 37 GPM (Nominal) • Pressures to 4600 PSI

SD16 Outlet Cover & Options

Pneumatic Power & Control


SD16 Outlet Cover & Options
Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
Outlet cover (FS-SD16/RC-SAE), SAE-16 end outlet port T, plugged SAE-16 top outlet,
•C1KF76 618305003 (1) machined for optional power beyond/closed center conversion 6.52
•C1HT29 4TAP318010 (3) M18 x 1.5 plug for power beyond / closed center option 0.03

SD16 Tie Rod & Mounting Bracket Kits

Fluid Conveying
Miscellaneous Products
SD16 Tie Rod & Mounting Bracket Kits
Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
•C1HU39 5TIR110170 (1) Tie rod kit for a 1-section valve assembly 1.21
•C1HU43 5TIR110218 (1) Tie rod kit for a 2-section valve assembly 1.47
•C1HU46 5TIR110266 (1) Tie rod kit for a 3-section valve assembly 1.73
•C1HU49 5TIR110316 (1) Tie rod kit for a 4-section valve assembly 2.01
•C1HU56 5TIR110410 (1) Tie rod kit for a 6-section valve assembly 2.59 Indexes & Technical Information
C1HU58 5TIR110458 (1) Tie rod kit for a 7-section valve assembly 2.79
C1JR82 5TIR110554 (1) Tie rod kit for a 9-section valve assembly 3.32
C1HU12 5STA125220 (2) Brackets kit 1.20

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
297
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center
Hydraulic Power & Control

Walvoil SD25 Series • Flows to 63 GPM (Nominal) • Pressures to 4600 PSI

Sectional Control Valves for Open & Closed Center Systems


Walvoil SD25 Series
Features: Simple, compact and heavy duty designed sectional valve from 1 to 12
sections, for open and closed center hydraulic systems • Main pressure relief valve •
Load check valve on every work section • Available with parallel or series circuit •
Optional power beyond port • Available with manual, pneumatic, hydraulic,
electro-hydraulic or cable controls • Interchangeable spools.
Nominal Flow Rating: 63 GPM.
Pneumatic Power & Control

Maximum Operating Pressure: 4600 PSI (Parallel circuit). 3050 PSI (Series circuit).
Maximum Back Pressure: 360 PSI on outlet port T.
Internal Leakage A(B) to T: 0.24 in³/min at 1450 PSI differential pressure.
Fluid Temperature Range: -4°F to 176°F with standard Buna-N seals.
Ambient Temperature Range: -40°F to 140°F.
Viscosity: 80 to 400 SSU Operating, 70 SSU Minimum, 1950 SSU Maximum.
Maximum Level of Contamination: ISO 4406 19/16.
Note: Performance data measured with mineral oil of 215 SSU viscosity at 104°F.
Dimensions & Technical Information: page 644
Fluid Conveying
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
298
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center

Hydraulic Power & Control


Walvoil SD25 Series • Flows to 63 GPM (Nominal) • Pressures to 4600 PSI

SD25 Inlet Covers & Options

Pneumatic Power & Control


SD25 Inlet Covers & Options
Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
Inlet cover (FE-SD25/AC(XG3)-SAE) with pilot-operated pressure relief (3) 360-4600
C1HV36 617205009 (1) PSI range and standard setting 1750 PSI, with blanking plug (4). SAE-20 end inlet port 18.93
P and plugged SAE-20 top inlet.

Fluid Conveying
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
299
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center
Hydraulic Power & Control

Walvoil SD25 Series • Flows to 63 GPM (Nominal) • Pressures to 4600 PSI

SD25 Working Sections & Options


Pneumatic Power & Control
Fluid Conveying

SD25 Working Sections & Options


Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
Miscellaneous Products

Working section (EL-SD25/P-18L-SAE), parallel circuit, 4way 3-pos A&B closed in


C1HV32 617105001 (1) neutral, complete with spring centering positioner (3), standard lever box (4) and 22.76
blanking plugs (5). SAE-16 work ports. Does NOT include M12 thread handlever.

•C1HQ59 170013025 (II) Handlever (Type AL01/M12x250), for mechanical joystick, M12 thread x 250mm long, 0.50
with black knob
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
300
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Sectional • Open & Closed Center

Hydraulic Power & Control


Walvoil SD25 Series • Flows to 63 GPM (Nominal) • Pressures to 4600 PSI

SD25 Outlet Cover & Options

Pneumatic Power & Control


SD25 Outlet Cover & Options
Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each

C1HV37 617305002 Outlet cover (FS-SD25/RC-SAE), SAE-20 end outlet port T, plugged SAE-20 top outlet, 15.50
(1) machined for optional power beyond/closed center conversion

SD25 Tie Rod & Mounting Bracket Kits

Fluid Conveying
Miscellaneous Products
SD25 Tie Rod & Mounting Bracket Kits
Catalog Price
Part No. Walvoil Model Key Description & (Walvoil Type Code) Wt. Each
C1HU61 5TIR112234 (1) Tie rod kit for a 1-section valve assembly 2.16
C1HU62 5TIR112296 (1) Tie rod kit for a 2-section valve assembly 2.63
C1HU13 5STA130270 (2) Brackets kit 1.76

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
301
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type
Hydraulic Power & Control

2-way, 2-position, Normally Closed Solenoid Valves


Vickers® SV4-10-C Series • To 6 GPM & 3000 PSI
Pneumatic Power & Control

Description: The SV4-10-C is a 2-way, 2-position, direct acting, spool-type, normally closed screw-in cartridge
solenoid valve, and requires a machined cavity or housing for installation.
Fluid Conveying

Operation: In the de-energized position, flow is blocked in both directions. In the energized position, the spool lifts
to allow flow in either direction.
Pressure Rating (All Ports): 3000 PSI.
Rated Flow: 6 GPM.
Internal Leakage: 5 in³ per minute maximum @ 3000 PSI.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Temperature Range: -40°F to 248°F (Extreme Limits).
Miscellaneous Products

Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.


Cartridge: Model SV4-10-C*, sold separately.
Housing: Cavity size C-10-2, sold separately, see page 410
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coil: "J" Series 20 Watt, sold separately, see page 414
2-way, 2-position, Normally Closed Solenoid Valves • Vickers® SV4-10-C Series • To 6 GPM & 3000 PSI
Catalog Vickers Manual Override Seal Price
Part No. Part No. Vickers Model Option Housing Coil (1 Required) Material Wt. Each
•C1BT22 565537 SV4-10-C-0-00 No None None Buna-N 0.29
Aluminum FR
C1MG11 02-167864 SV4-10-C-2G-230AP No 1/4" BSPP 230VAC 1/2" NPT conduit Buna-N
Indexes & Technical Information

Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).

Parts for Vickers® SV4-10-C Solenoid Valve Cartridges


Catalog Price
Part No. Part Number Description Wt. Each
C1FK22 565806 SK2-10-2 Buna-N Seal Kit 0.01

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
302
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type

Hydraulic Power & Control


3-way, 2-position Solenoid Valves
Vickers® SV4B-12-3 Series • To 11 GPM & 3000 PSI

Pneumatic Power & Control


Description: The SV4B-12-3 is a 3-way, 2-position, spool-type, direct acting screw-in cartridge solenoid valve,
and requires a machined cavity or housing for installation.
Operation: In the de-energized position, this valve allows flow from port 1 to port 2 while port 3 is blocked. In the
energized position, flow is allowed from port 2 to port 3 while port 1 is blocked.
Pressure Rating (All Ports): 3000 PSI.
Rated Flow: 11 GPM.

Fluid Conveying
Internal Leakage: 21.5 in³/min max @ 3000 psi
Temperature Range: -40°F to 248°F
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV4B-12-3*, sold separately.
Housing: Cavity size C-12-3, sold separately, see page 411
Coil: R Series, sold separately, see page 414
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).

Miscellaneous Products
3-way, 2-position Solenoid Valves • Vickers® SV4B-12-3 Series • To 11 GPM & 3000 PSI
Catalog Seal Price
Part No. Vickers Part No. Vickers Model Housing Coil (1 Required) Material Wt. Each
C1MG20 02-200192 SV4B-12-3P-0-00 None None Buna-N 1.90

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
303
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type
Hydraulic Power & Control

2-way, 2-position, Normally Closed Solenoid Valves


Vickers® SV5-8-C Series • To 6 GPM & 3000 PSI
Pneumatic Power & Control

Description: The SV5-8-C is a 2-way, 2-position, poppet type, pilot operated, normally closed screw-in cartridge
solenoid valve, and requires a machined cavity or housing for installation. This valve is used in applications
requiring low leakage.
Operation: In the de-energized position, the SV5-8-C blocks flow from port 2 to port 1, and free flow is allowed
Fluid Conveying

from port 1 to port 2. In the energized position, flow from port 1 to port 2 is restricted and free flow is allowed
from port 2 to port 1.
Pressure Rating (All Ports): 3000 PSI.
Rated Flow: 6 GPM.
Internal Leakage: Less than 5 drops per minute maximum @ 3000 PSI.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Miscellaneous Products

Cartridge: Model SV5-8-C*, sold separately.


Housing: Cavity size C-8-2, sold separately, see page 410
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coil: "S" Series 16 Watt, sold separately, see page 414
2-way, 2-position, Normally Closed Solenoid Valves • Vickers® SV5-8-C Series • To 6 GPM & 3000 PSI
Catalog Vickers Manual Override Seal Price
Part No. Part No. Vickers Model Option Housing Coil (1 Required) Material Wt. Each
•C1ZZ82 02-160759 SV5-8-C-0-00 No None None Buna-N 0.22
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
304
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type

Hydraulic Power & Control


2-way, 2-position, Normally Closed Solenoid Valves
Vickers® SV3-10-C Series • To 12 GPM & 3000 PSI

Pneumatic Power & Control


Description: The SV3-10-C is a 2-way, 2-position, pilot operated, poppet-type, normally closed screw-in cartridge
solenoid valve, and requires a machined cavity or housing for installation.

Fluid Conveying
Operation: In the de-energized position, flow is blocked from port 2 to port 1 and free flow is allowed from port 1 to
port 2. In the energized position, the poppet lifts to allow flow in either direction.
Pressure Rating (All Ports): 3000 PSI.
Rated Flow: 12 GPM.
Internal Leakage: Less than 5 drops per minute maximum @ 3000 PSI.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Temperature Range: -40°F to 248°F (Extreme Limits).

Miscellaneous Products
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV3-10-C*, sold separately.
Housing: Cavity size C-10-2, sold separately, see page 410
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coil: "J" Series 20 Watt, sold separately, see page 414
2-way, 2-position, Normally Closed Solenoid Valves • Vickers® SV3-10-C Series • To 12 GPM & 3000 PSI
Catalog Vickers Manual Override Seal Price
Part No. Part No. Vickers Model Option Housing Coil (1 Required) Material Wt. Each
•C1BT21 565536 SV3-10-C-0-00 No None None Buna-N 0.31
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum). Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
305
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type
Hydraulic Power & Control

2-way, 2-position, Normally Closed Solenoid Valves


Vickers® SV1-10-C Series • To 12 GPM & 3000 PSI
Pneumatic Power & Control

Description: The SV1-10-C is a 2-way, 2-position, pilot operated, poppet-type, normally closed screw-in cartridge
solenoid valve, and requires a machined cavity or housing for installation.
Fluid Conveying

Operation: In the de-energized position, flow is blocked from port 2 to port 1 and free flow is allowed from port 1 to
port 2. In the energized position, flow from port 1 to port 2 is restricted while free flow is allowed from port 2 to
port 1.
Pressure Rating (All Ports): 3000 PSI.
Rated Flow: 12 GPM.
Internal Leakage: Port 2 to Port 1: 5 drops per minute maximum @ 3000 PSI.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Miscellaneous Products

Temperature Range: -40°F to 248°F (Extreme Limits).


Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV1-10-C*, sold separately.
Housing: Cavity size C-10-2, sold separately, see page 410
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coil: "J" Series 20 Watt, sold separately, see page 414
2-way, 2-position, Normally Closed Solenoid Valves • Vickers® SV1-10-C Series • To 12 GPM & 3000 PSI
Catalog Vickers Manual Override Seal Price
Part No. Part No. Vickers Model Option Housing Coil (1 Required) Material Wt. Each
•C1BT20 565534 SV1-10-C-0-00 No None None Buna-N 0.30
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
Indexes & Technical Information

maximum). Steel (Fatigue-rated Steel 5000 psi maximum).

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
306
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type

Hydraulic Power & Control


2-way, 2-position, Normally Closed Solenoid Valves
Vickers® SV3-12-C Series • To 30 GPM & 3000 PSI

Pneumatic Power & Control


Fluid Conveying
Description: This is a 2-way, 2-position, poppet type, pilot operated, normally closed solenoid valve. This valve is
used in applications requiring low leakage, such as load holding applications or as a general purpose diverter or

Miscellaneous Products
dump valve.
Operation: In the de-energized position the valve blocks flow from port 2 to 1 and free flow is allowed from port 1
to 2. When the solenoid is energized the pilot poppet is pulled off the seat allowing the valve to open in both
directions.
Pressure Rating (All Ports): 3000 PSI.
Rated Flow: 30 GPM.
Internal Leakage: Port 2 to Port 1: Less than 5 drops/min, max @ 3000 PSI.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Temperature Range: -40° to 248°F (Extreme Limits).
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV3-12-C*, sold separately Indexes & Technical Information
Housing: Cavity size C-12-2 or C-12-2U sold separately. Add “U” after number if undercut is required. If undercut
is not specified, expect 10 PSI @ 15 GPM and 20 PSI @ 30 GPM higher pressure drop, see page 410
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coil: J series, 23 Watt, sold separately, see page 414
2-way, 2-position, Normally Closed Solenoid Valves • Vickers® SV3-12-C Series • To 30 GPM & 3000 PSI
Catalog Seal Price
Part No. Vickers Part No. Vickers Model Housing Coil (1 Required) Material Wt. Each
C1FQ33 02-161062 SV3-12-C-0-00 None None Buna-N 0.51

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
307
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type
Hydraulic Power & Control

2-way, 2-position, Normally Closed Solenoid Valves


Vickers® SV13-10-C Series • To 12 GPM & 5000 PSI
Pneumatic Power & Control
Fluid Conveying

Description: This is a 2-way, 2-position, poppet type, high pressure, pilot operated, normally closed solenoid
valve. This valve is used in applications requiring low leakage, such as load holding applications or as a general
purpose diverter or dump valve.
Operation: In the de-energized position the valve blocks flow from port 2 to 1 and free flow is allowed from port 1
to 2. When the solenoid is energized the pilot poppet is pulled off the seat allowing the valve to open in both
directions.
Miscellaneous Products

Pressure Rating (All Ports): 5000 PSI. (CAUTION: Pressures over 3000 PSI require steel housing or manifold).
Rated Flow: 12 GPM.
Internal Leakage: 5 drops per minute maximum @ 5000 PSI.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Temperature Range: -40° to 212°F (Extreme Limits).
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV13-10-C*, sold separately.
Housing: Cavity size C-10-2, sold separately, see page 410
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coil: "H" - 10 Series, 29 Watt, sold separately, see page 414
Indexes & Technical Information

2-way, 2-position, Normally Closed Solenoid Valves • Vickers® SV13-10-C Series • To 12 GPM & 5000 PSI
Catalog Seal Price
Part No. Vickers Part No. Vickers Model Housing Coil (1 Required) Material Wt. Each
C1MG12 02-175805 SV13-10-C-0-00 None None Buna-N
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
308
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type

Hydraulic Power & Control


2-way, 2-position, Normally Closed Solenoid Valves
Vickers® SBV11-10-C Series • To 20 GPM & 5000 PSI

Pneumatic Power & Control


Fluid Conveying
Description: The SBV11-10-C is a 2-way, 2-position, bi-directional, pilot operated, poppet-type, normally closed
screw-in cartridge solenoid valve, and requires a machined cavity or housing for installation.
Operation: In the de-energized position, flow is blocked in both directions. In the energized position, flow is
allowed in both directions.

Miscellaneous Products
Pressure Rating (All Ports): 5000 PSI. (CAUTION: Pressures over 3000 PSI require steel housing or manifold).
Rated Flow: 20 GPM.
Internal Leakage: 5 drops per minute maximum @ 5000 PSI.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Temperature Range: -40°F to 212°F (Extreme Limits).
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SBV11-10-C*, sold separately.
Housing: Cavity size C-10-2, sold separately, see page 410
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coil: "H" Series 26 Watt, sold separately, see page 414
2-way, 2-position, Normally Closed Solenoid Valves • Vickers® SBV11-10-C Series • To 20 GPM & 5000 Indexes & Technical Information
PSI
Catalog Seal Price
Part No. Vickers Part No. Vickers Model Housing Coil (1 Required) Material Wt. Each
C1HY32 02-177580 SBV11-10-C-0-00 None None Buna-N 0.39
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
309
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type
Hydraulic Power & Control

2-way, 2-position, Normally Closed Solenoid Valves


Vickers® SBV11-12-C Series • To 30 GPM & 5000 PSI
Pneumatic Power & Control

Description: The SBV11-12-C is a 2-way, 2-position, bi-directional, pilot operated, poppet-type, normally closed
screw-in cartridge solenoid valve, and requires a machined cavity or housing for installation.
Operation: In the de-energized position, flow is blocked in both directions. In the energized position, flow is
allowed in both directions.
Pressure Rating (All Ports): 5000 PSI. (CAUTION: Pressures over 3000 PSI require steel housing or manifold).
Rated Flow: 30 GPM
Fluid Conveying

Internal Leakage: 5 drops per minute maximum @ 5000 PSI.


Temperature Range: -40°F to 212°F
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SBV11-12-C*, sold separately.
Housing: Cavity size C-12-2, sold separately, see page 410
Coil: H Series, sold separately, see page 414
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Miscellaneous Products

2-way, 2-position, Normally Closed Solenoid Valves • Vickers® SBV11-12-C Series • To 30 GPM & 5000
PSI
Catalog Seal Price
Part No. Vickers Part No. Vickers Model Housing Coil (1 Required) Material Wt. Each
C1LW47 02-177576 SBV11-12-C-0-00 None None Buna-N 0.59
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
310
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type

Hydraulic Power & Control


2-way, 2-position, Normally Closed Solenoid Valves
Vickers® SV13-12-C Series • To 30 GPM & 5000 PSI

Pneumatic Power & Control


Description: The SV13-12-C is a 2-way, 2-position, pilot operated, poppet-type, normally closed screw-in
cartridge solenoid valve, and requires a machined cavity or housing for installation.
Operation: In the de-energized position, flow is blocked from port 2 to port 1 and free flow is allowed from port 1 to
port 2. In the energized position, the poppet lifts to allow flow in either direction.
Pressure Rating (All Ports): 5000 PSI
Rated Flow: 30 GPM

Fluid Conveying
Internal Leakage: Less than 5 drops per minute maximum @ 5000 PSI.
Temperature Range: -40° to 212°F
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV13-12-C*, sold separately.
Housing: Cavity size C-12-2, sold separately, see page 410
Coil: H series, sold separately, see page 414
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).

Miscellaneous Products
2-way, 2-position, Normally Closed Solenoid Valves • Vickers® SV13-12-C Series • To 30 GPM & 5000 PSI
Catalog Seal Price
Part No. Vickers Part No. Vickers Model Housing Coil (1 Required) Material Wt. Each
C1KH69 02-175827 SV13-12-C-0-00 None None Buna-N 0.61

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
311
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type
Hydraulic Power & Control

2-way, 2-position, Normally Closed Solenoid Valves


Vickers® SV1-16-C Series • To 35 GPM & 3000 PSI
Pneumatic Power & Control
Fluid Conveying

Description: The SV1-16-C is a 2-way, 2-position, pilot operated, poppet-type, normally closed screw-in cartridge
solenoid valve, and requires a machined cavity or housing for installation.
Operation: In the de-energized position, flow is blocked from port 2 to port 1 and free flow is allowed from port 1 to
port 2. In the energized position, bi-directional flow is allowed between port 1 and port 2.
Pressure Rating (All Ports): 3000 PSI.
Rated Flow: 35 GPM.
Internal Leakage: Port 2 to Port 1: 5 drops per minute maximum @ 3000 PSI.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Miscellaneous Products

Temperature Range: -40°F to 248°F (Extreme Limits).


Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV1-16-C*, sold separately.
Housing: Cavity size C-16-2, sold separately, see page 410
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coil: "J" Series 20 Watt, sold separately, see page 414
2-way, 2-position, Normally Closed Solenoid Valves • Vickers® SV1-16-C Series • To 35 GPM & 3000 PSI
Catalog Vickers Manual Override Seal Price
Part No. Part No. Vickers Model Option Housing Coil (1 Required) Material Wt. Each
•C1BT23 565538 SV1-16-C-0-00 No None None Buna-N 0.72
Indexes & Technical Information

Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
312
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type

Hydraulic Power & Control


2-way, 2-position, Normally Closed Solenoid Valves
Vickers® SV13-16-C Series • To 35 GPM & 5000 PSI

Pneumatic Power & Control


Description: The SV13-16-C is a 2-way, 2-position, pilot operated, poppet-type, normally closed screw-in
cartridge solenoid valve, and requires a machined cavity or housing for installation.
Operation: In the de-energized position, flow is blocked from port 2 to port 1 and free flow is allowed from port 1 to
port 2. In the energized position, the poppet lifts to allow flow in either direction.
Pressure Rating (All Ports): 5000 PSI
Rated Flow: 35 GPM

Fluid Conveying
Internal Leakage: Less than 5 drops per minute maximum @ 5000 PSI.
Temperature Range: -40° to 212°F
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV13-16-C*, sold separately.
Housing: Cavity size C-16-2, sold separately, see page 410
Coil: H series, sold separately, see page 414
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).

Miscellaneous Products
2-way, 2-position, Normally Closed Solenoid Valves • Vickers® SV13-16-C Series • To 35 GPM & 5000 PSI
Catalog Seal Price
Part No. Vickers Part No. Vickers Model Housing Coil (1 Required) Material Wt. Each
C1MG17 02-175823 SV13-16-C-0-00 None None Buna-N 0.85

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
313
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type
Hydraulic Power & Control

2-way, 2-position, Normally Closed Solenoid Valves


Vickers® SV2-20-C Series • To 60 GPM & 3000 PSI
Pneumatic Power & Control

Description: The SV2-20-C is a 2-way, 2-position, pilot operated, poppet-type, normally closed screw-in cartridge
solenoid valve, and requires a machined cavity or housing for installation.
Operation: In the de-energized position, flow is blocked from port 2 to port 1 and free flow is allowed from port 1 to
port 2. In the energized position, free flow is allowed between both ports.
Pressure Rating (All Ports): 3000 PSI.
Fluid Conveying

Rated Flow: 60 GPM.


Internal Leakage: Port 2 to Port 1: Less than 5 drops per minute maximum @ 3000 PSI.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV2-20-C*, sold separately.
Housing: Cavity size C-20-2, sold separately, see page 410
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Miscellaneous Products

Coil: "J" Series 20 Watt, sold separately, see page 414


2-way, 2-position, Normally Closed Solenoid Valves • Vickers® SV2-20-C Series • To 60 GPM & 3000 PSI
Catalog Vickers Manual Override Seal Price
Part No. Part No. Vickers Model Option Housing Coil (1 Required) Material Wt. Each
C1FA73 565539 SV2-20-C-0-00 No None None Buna-N 1.16
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
314
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type

Hydraulic Power & Control


2-way, 2-position, Normally Closed Solenoid Valves
Vickers® SV13-20-C Series • To 60 GPM & 5000 PSI

Pneumatic Power & Control


Description: The SV13-20-C is a 2-way, 2-position, pilot operated, poppet-type, normally closed screw-in
cartridge solenoid valve, and requires a machined cavity or housing for installation.
Operation: In the de-energized position, flow is blocked from port 2 to port 1 and free flow is allowed from port 1 to
port 2. In the energized position, the poppet lifts to allow flow in either direction.
Pressure Rating (All Ports): 5000 PSI
Rated Flow: 60 GPM.

Fluid Conveying
Internal Leakage: Less than 5 drops per minute maximum @ 5000 PSI.
Temperature Range: -40° to 212°F
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV13-20-C*, sold separately.
Housing: Cavity size C-20-2, sold separately, see page 410
Coil: H series, sold separately, see page 414
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).

Miscellaneous Products
2-way, 2-position, Normally Closed Solenoid Valves • Vickers® SV13-20-C Series • To 60 GPM & 5000 PSI
Catalog Seal Price
Part No. Vickers Part No. Vickers Model Housing Coil (1 Required) Material Wt. Each
C1MG15 02-175819 SV13-20-C-0-00 None None Buna-N 1.37

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
315
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type
Hydraulic Power & Control

2-way, 2-position, Normally Open Solenoid Valves


Vickers® SV4-10-O Series • To 6 GPM & 3000 PSI
Pneumatic Power & Control

Description: The SV4-10-O is a 2-way, 2-position, spool-type, direct acting, normally open screw-in cartridge
solenoid valve, and requires a machined cavity or housing for installation.
Operation: In the de-energized position, this valve allows bi-directional flow between port 1 and port 2. In the
Fluid Conveying

energized position both ports are closed.


Pressure Rating (All Ports): 3000 PSI.
Rated Flow: 6 GPM.
Internal Leakage: Port 2 to Port 1: 5 in³ per minute maximum @ 3000 PSI with valve energized.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV4-10-O*, sold separately.
Miscellaneous Products

Housing: Cavity size C-10-2, sold separately, see page 410


Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coil: "J" Series 20 Watt, sold separately, see page 414
2-way, 2-position, Normally Open Solenoid Valves • Vickers® SV4-10-O Series • To 6 GPM & 3000 PSI
Catalog Vickers Manual Override Seal Price
Part No. Part No. Vickers Model Option Housing Coil (1 Required) Material Wt. Each
•C1BT25 565542 SV4-10-O-0-00 No None None Buna-N 0.30
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).
Indexes & Technical Information

Parts for Vickers® SV4-10-O Solenoid Valve Cartridges


Catalog Price
Part No. Part Number Description Wt. Each
C1FK22 565806 SK2-10-2 Buna-N Seal Kit 0.01

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
316
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type

Hydraulic Power & Control


2-way, 2-position, Normally Open Solenoid Valves
Vickers® SV5-8-O Series • To 6 GPM & 3000 PSI

Pneumatic Power & Control


Description: The SV5-8-O is a 2-way, 2-position, poppet-type, pilot operated, normally open screw-in cartridge
solenoid valve, and requires a machined cavity or housing for installation. This valve is used in applications
requiring low leakage.
Operation: In the de-energized position, this valve allows free flow from port 2 to port 1, and restricted flow from

Fluid Conveying
port 1 to port 2. In the energized position, flow is blocked from port 2 to port 1, and free flow is allowed from port
1 to port 2.
Pressure Rating (All Ports): 3000 PSI.
Rated Flow: 6 GPM.
Internal Leakage: Less than 5 drops per minute maximum @ 3000 PSI with valve energized.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.

Miscellaneous Products
Cartridge: Model SV5-8-O*, sold separately.
Housing: Cavity size C-8-2, sold separately, see page 410
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coil: "S" Series 16 Watt, sold separately, see page 414
2-way, 2-position, Normally Open Solenoid Valves • Vickers® SV5-8-O Series • To 6 GPM & 3000 PSI
Catalog Vickers Manual Override Seal Price
Part No. Part No. Vickers Model Option Housing Coil (1 Required) Material Wt. Each
•C1AD17 02-160761 SV5-8-0-0-00 No None None Buna-N 0.29
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
317
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type
Hydraulic Power & Control

2-way, 2-position, Normally Open Solenoid Valves


Vickers® SV3-10-O Series • To 12 GPM & 3000 PSI
Pneumatic Power & Control
Fluid Conveying

Description: The SV3-10-O is a 2-way, 2-position, poppet-type, pilot operated, normally open screw-in cartridge
solenoid valve, and requires a machined cavity or housing for installation. This valve is used in applications
requiring low leakage.
Operation: In the de-energized position, this valve allows bi-directional flow between port 1 and port 2. In the
energized position, flow is blocked from port 2 to port 1, and is allowed from port 1 to port 2 when spring force is
overcome.
Pressure Rating (All Ports): 3000 PSI.
Rated Flow: 12 GPM.
Miscellaneous Products

Internal Leakage: Port 2 to Port 1: Less than 5 drops per minute maximum @ 3000 PSI with valve energized.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV3-10-O*, sold separately.
Housing: Cavity size C-10-2, sold separately, see page 410
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coil: "J" Series 20 Watt, sold seperately, see page 414
2-way, 2-position, Normally Open Solenoid Valves • Vickers® SV3-10-O Series • To 12 GPM & 3000 PSI
Catalog Vickers Manual Override Seal Price
Indexes & Technical Information

Part No. Part No. Vickers Model Option Housing Coil (1 Required) Material Wt. Each
•C1BT24 565541 SV3-10-O-0-00 No None None Buna-N 0.37
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
318
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type

Hydraulic Power & Control


2-way, 2-position, Normally Open Solenoid Valves
Vickers® SV13-10-O Series • To 12 GPM & 5000 PSI

Pneumatic Power & Control


Description: The SV13-10-O is a 2-way, 2-position, poppet-type, pilot operated, normally open screw-in cartridge
solenoid valve, and requires a machined cavity or housing for installation.
Operation: In the de-energized position, this valve allows bi-directional flow between port 1 and port 2. In the
energized position, flow is blocked from port 2 to port 1, and is allowed from port 1 to port 2 when spring force is
overcome.
Pressure Rating (All Ports): 5000 PSI

Fluid Conveying
Rated Flow: 12 GPM
Internal Leakage: Less than 5 drops per minute maximum @ 5000 PSI
Temperature Range: -40° to 212°F
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV13-10-O*, sold separately.
Housing: Cavity size C-10-2, sold separately, see page 410
Coils: H Series, sold separately, see page 414
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).

Miscellaneous Products
2-way, 2-position, Normally Open Solenoid Valves • Vickers® SV13-10-O Series • To 12 GPM & 5000 PSI
Catalog Seal Price
Part No. Vickers Part No. Vickers Model Housing Coil (1 Required) Material Wt. Each
C1MG13 02-175813 SV13-10-O-0-00 None None Buna-N

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
319
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type
Hydraulic Power & Control

2-way, 2-position, Normally Open Solenoid Valves


Vickers® SBV11-10-O Series • To 20 GPM & 5000 PSI
Pneumatic Power & Control
Fluid Conveying

Description: The SBV11-10-O is a 2-way, 2-position, bi-directional, pilot operated, poppet-type, normally open
screw-in cartridge solenoid valve, and requires a machined cavity or housing for installation.
Operation: In the de-energized position, flow is allowed in both directions. In the energized position, flow is
blocked in both directions.
Pressure Rating (All Ports): 5000 PSI. (CAUTION: Pressures over 3000 PSI require steel housing or manifold).
Miscellaneous Products

Rated Flow: 20 GPM.


Internal Leakage: Port 1 to Port 2, or Port 2 to Port 1: 5 drops per minute maximum @ 5000 PSI.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Temperature Range: -40°F to 212°F (Extreme Limits).
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SBV11-10-O*, sold separately.
Housing: Cavity size C-10-2, sold separately, see page 410
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coil: "H" Series 26 Watt, sold separately, see page 414
2-way, 2-position, Normally Open Solenoid Valves • Vickers® SBV11-10-O Series • To 20 GPM & 5000 PSI
Indexes & Technical Information

Catalog Seal Price


Part No. Vickers Part No. Vickers Model Housing Coil (1 Required) Material Wt. Each
C1HY31 02-177579 SBV11-10-0-0-00 None None Buna-N 0.39
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
320
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type

Hydraulic Power & Control


2-way, 2-position, Normally Open Solenoid Valves
Vickers® SV3-12-O Series • To 30 GPM & 3000 PSI

Pneumatic Power & Control


Description: The SV3-12-O is a 2-way, 2-position, poppet-type, pilot operated, normally open screw-in cartridge
solenoid valve, and requires a machined cavity or housing for installation.
Operation: In the de-energized position, this valve allows bi-directional flow between port 1 and port 2. In the
energized position, flow is blocked from port 2 to port 1, and is allowed from port 1 to port 2 when spring force is
overcome.

Fluid Conveying
Pressure Rating (All Ports): 3000 PSI.
Rated Flow: 30 GPM.
Internal Leakage: Port 2 to Port 1: Less than 5 drops per minute maximum @ 3000 PSI with valve energized.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration: ISO 4406 Cleanliness Level 17/15/12 or cleaner.
Cartridge: Model SV3-12-O*, sold separately.
Housing: Cavity size C-12-2 or C-12-2U, sold separately, see page 410

Miscellaneous Products
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coil: "J" Series 20 Watt, sold separately, see page 414
2-way, 2-position, Normally Open Solenoid Valves • Vickers® SV3-12-O Series • To 30 GPM & 3000 PSI
Catalog Vickers Manual Override Seal Price
Part No. Part No. Vickers Model Option Housing Coil (1 Required) Material Wt. Each
C1FQ44 02-161311 SV3-12-O-0-00 No None None Buna-N 0.58
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
321
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type
Hydraulic Power & Control

2-way, 2-position, Normally Open Solenoid Valves


Vickers® SV13-12-O Series • To 30 GPM & 5000 PSI
Pneumatic Power & Control

Description: The SV13-12-O is a 2-way, 2-position, poppet-type, pilot operated, normally open screw-in cartridge
solenoid valve, and requires a machined cavity or housing for installation.
Operation: In the de-energized position, this valve allows bi-directional flow between port 1 and port 2. In the
energized position, flow is blocked from port 2 to port 1, and is allowed from port 1 to port 2 when spring force is
overcome.
Pressure Rating (All Ports): 5000 PSI
Fluid Conveying

Rated Flow: 30 GPM


Internal Leakage: Less than 5 drops per minute maximum @ 5000 PSI
Temperature Range: -40° to 212°F
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV13-12-O*, sold separately.
Housing: Cavity size C-12-2, sold separately, see page 410
Coils: H Series, sold separately, see page 414
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Miscellaneous Products

2-way, 2-position, Normally Open Solenoid Valves • Vickers® SV13-12-O Series • To 30 GPM & 5000 PSI
Catalog Seal Price
Part No. Vickers Part No. Vickers Model Housing Coil (1 Required) Material Wt. Each
C1MG18 02-175825 SV13-12-0-0-00 None None Buna-N 0.59
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
322
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type

Hydraulic Power & Control


2-way, 2-position, Normally Open Solenoid Valves
Vickers® SV3-16-O Series • To 35 GPM & 3000 PSI

Pneumatic Power & Control


Fluid Conveying
Description: The SV3-16-O is a 2-way, 2-position, poppet-type, pilot operated, normally open screw-in cartridge
solenoid valve, and requires a machined cavity or housing for installation.
Operation: In the de-energized position, this valve allows bi-directional flow between port 1 and port 2. In the
energized position, flow is blocked from port 2 to port 1, and is allowed from port 1 to port 2 when spring force is
overcome.
Pressure Rating (All Ports): 3000 PSI.
Rated Flow: 35 GPM.

Miscellaneous Products
Internal Leakage: Port 2 to Port 1: Less than 5 drops per minute maximum @ 3000 PSI with valve energized.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV3-16-O*, sold separately.
Housing: Cavity size C-16-2, sold separately, see page 410
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coil: "J" Series 20 Watt, sold separately, see page 414
2-way, 2-position, Normally Open Solenoid Valves • Vickers® SV3-16-O Series • To 35 GPM & 3000 PSI
Catalog Vickers Manual Override Seal Price Indexes & Technical Information
Part No. Part No. Vickers Model Option Housing Coil (1 Required) Material Wt. Each
•C1BT26 565544 SV3-16-O-0-00 No None None Buna-N 0.74
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
323
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type
Hydraulic Power & Control

2-way, 2-position, Normally Open Solenoid Valves


Vickers® SV13-16-O Series • To 35 GPM & 5000 PSI
Pneumatic Power & Control

Description: The SV13-16-O is a 2-way, 2-position, poppet-type, pilot operated, normally open screw-in cartridge
solenoid valve, and requires a machined cavity or housing for installation.
Operation: In the de-energized position, this valve allows bi-directional flow between port 1 and port 2. In the
energized position, flow is blocked from port 2 to port 1, and is allowed from port 1 to port 2 when spring force is
overcome.
Pressure Rating (All Ports): 5000 PSI
Fluid Conveying

Rated Flow: 35 GPM


Internal Leakage: Less than 5 drops per minute maximum @ 5000 PSI.
Temperature Range: -40° to 212°F
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV13-16-O*, sold separately.
Housing: Cavity size C-16-2, sold separately, see page 410
Coils: page 414 H Series, sold separately, see
Solenoid Connectors: (Required on models that use DIN 43650 connectors). page 415
Miscellaneous Products

2-way, 2-position, Normally Open Solenoid Valves • Vickers® SV13-16-O Series • To 35 GPM & 5000 PSI
Catalog Seal Price
Part No. Vickers Part No. Vickers Model Housing Coil (1 Required) Material Wt. Each

C1MG16 02-175821 SV13-16-0-0-00 None None Buna-N 0.95


Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
324
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type

Hydraulic Power & Control


2-way, 2-position, Normally Open Solenoid Valves
Vickers® SV3-20-O Series • To 60 GPM & 3000 PSI

Pneumatic Power & Control


Fluid Conveying
Description: The SV3-20-O is a 2-way, 2-position, poppet-type, pilot operated, normally open screw-in cartridge
solenoid valve, and requires a machined cavity or housing for installation.
Operation: In the de-energized position, this valve allows bi-directional flow between port 1 and port 2. In the
energized position, flow is blocked from port 2 to port 1, and is allowed from port 1 to port 2 when spring force is
overcome.
Pressure Rating (All Ports): 3000 PSI.
Rated Flow: 60 GPM.

Miscellaneous Products
Internal Leakage: Port 2 to Port 1: Less than 5 drops per minute maximum @ 3000 PSI with valve energized.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV3-20-O*, sold separately.
Housing: Cavity size C-20-2, sold separately, see page 410
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coil: "J" Series 20 Watt, sold separately, see page 414
2-way, 2-position, Normally Open Solenoid Valves • Vickers® SV3-20-O Series • To 60 GPM & 3000 PSI
Catalog Vickers Manual Override Seal Price
Part No. Part No. Vickers Model Option Housing Coil (1 Required) Material Wt. Each Indexes & Technical Information
C1BT27 565545 SV3-20-O-0-00 No None None Buna-N 1.25
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
325
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type
Hydraulic Power & Control

2-way, 2-position, Normally Open Solenoid Valves


Vickers® SV13-20-O Series • To 60 GPM & 5000 PSI
Pneumatic Power & Control

Description: The SV13-20-O is a 2-way, 2-position, poppet-type, pilot operated, normally open screw-in cartridge
solenoid valve, and requires a machined cavity or housing for installation.
Operation: In the de-energized position, this valve allows bi-directional flow between port 1 and port 2. In the
energized position, flow is blocked from port 2 to port 1, and is allowed from port 1 to port 2 when spring force is
overcome.
Pressure Rating (All Ports): 5000 PSI
Fluid Conveying

Rated Flow: 60 GPM


Internal Leakage: Less than 5 drops per minute maximum @ 5000 PSI
Temperature Range: -40° to 212°F
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV13-20-O*, sold separately.
Housing: Cavity size C-20-2, sold separately, see page 410
Coils: H Series, sold separately, see page 414
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Miscellaneous Products

2-way, 2-position, Normally Open Solenoid Valves • Vickers® SV13-20-O Series • To 60 GPM & 5000 PSI
Catalog Seal Price
Part No. Vickers Part No. Vickers Model Housing Coil (1 Required) Material Wt. Each
C1MG14 02-175817 SV13-20-0-0-00 None None Buna-N 1.37
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
326
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type

Hydraulic Power & Control


3-way, 2-position Solenoid Valves
Vickers® SV1-8-3 Series • To 3 GPM & 3000 PSI

Pneumatic Power & Control


Description: The SV1-8-3 is a 3-way, 2-position, spool-type, direct acting screw-in cartridge solenoid valve, and

Fluid Conveying
requires a machined cavity or housing for installation. This valve can be used in applications requiring separate
pressure and tank lines, such as a single acting cylinder.
Operation: In the de-energized position, this valve allows flow from port 2 to port 1 while port 3 is blocked. In the
energized position, flow is allowed from port 1 to port 3 while port 2 is blocked.
Pressure Rating: 3000 PSI all ports.
Rated Flow: 3 GPM.
Internal Leakage: 5 in³ per minute maximum @ 3000 PSI.
Note: Performance data is typical with fluid at 105 SSU and 120°F.

Miscellaneous Products
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV1-8-3*, sold separately.
Housing: Cavity size C-8-3, sold separately, see page 411
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Seal Kit: 02-160755 (Buna-N), 02-160756 (Viton®).
Coil: "S" Series 16 Watt, sold separately, see page 414
3-way, 2-position Solenoid Valves • Vickers® SV1-8-3 Series • To 3 GPM & 3000 PSI
Catalog Vickers Manual Override Seal Price
Part No. Part No. Vickers Model Option Housing Coil (1 Required) Material Wt. Each
Indexes & Technical Information
C1HL36 02-160771 SV1-8-3-0-00 No None None Buna-N 0.24
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
327
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type
Hydraulic Power & Control

3-way, 2-position Solenoid Valves


Vickers® SV4-8-3 Series • To 4 GPM & 3000 PSI
Pneumatic Power & Control

Description: The SV4-8-3 is a 3-way, 2-position, spool-type, direct acting screw-in cartridge solenoid valve, and
Fluid Conveying

requires a machined cavity or housing for installation.


Operation: In the de-energized position, this valve allows flow from port 2 to port 1 while port 3 is blocked. In the
energized position, flow is allowed from port 2 to port 3 while port 1 is blocked. Pressure on port 1 should not
exceed 300 PSI.
Pressure Rating: 3000 PSI port 2 and port 3. 300 PSI port 1.
Rated Flow: 4 GPM.
Internal Leakage: 5 in³ per minute maximum @ 3000 PSI.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Miscellaneous Products

Temperature Range: -40°F to 248°F (Extreme Limits).


Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV4-8-3*, sold separately.
Housing: Cavity size C-8-3, sold separately, see page 411
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coil: "S" Series 16 Watt, sold separately, see page 414
3-way, 2-position Solenoid Valves • Vickers® SV4-8-3 Series • To 4 GPM & 3000 PSI
Catalog Vickers Manual Override Seal Price
Part No. Part No. Vickers Model Option Housing Coil (1 Required) Material Wt. Each
24VDC with Deutsch
connector and with
Indexes & Technical Information

C1FV36 02-198050 SV4-8-3-0-24BNS No None arc suppression Buna-N 0.74


diode
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
328
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type

Hydraulic Power & Control


3-way, 2-position Solenoid Valves
Vickers® SV4-10-3 Series • To 6 GPM & 3000 PSI

Pneumatic Power & Control


Description: The SV4-10-3 is a 3-way, 2-position, spool-type, direct acting screw-in cartridge solenoid valve, and

Fluid Conveying
requires a machined cavity or housing for installation.
Operation: In the de-energized position, this valve allows flow from port 1 to port 2 while port 3 is blocked. In the
energized position, flow is allowed from port 2 to port 3 while port 1 is blocked.
Pressure Rating (All Ports): 3000 PSI.
Rated Flow: 6 GPM.
Internal Leakage: 10 in³ per minute maximum @ 3000 PSI.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Temperature Range: -40°F to 248°F (Extreme Limits).

Miscellaneous Products
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV4-10-3*, sold separately.
Housing: Cavity size C-10-3, sold separately, see page 411
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coil: "J" Series 20 Watt, sold separately, see page 414
3-way, 2-position Solenoid Valves • Vickers® SV4-10-3 Series • To 6 GPM & 3000 PSI
Catalog Vickers Manual Override Seal Price
Part No. Part No. Vickers Model Option Housing Coil (1 Required) Material Wt. Each
•C1BT60 566307 SV4-10-3-0-00 No None None Buna-N 0.40
C1KH68 02-167839 SV4-10-3-0-115AP No None 115VAC 1/2" NPT conduit Buna-N 1.22
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi Indexes & Technical Information
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
329
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type
Hydraulic Power & Control

3-way, 2-position Solenoid Valves


Vickers® SV1-10-3 Series • To 6 GPM & 3000 PSI
Pneumatic Power & Control

Description: The SV1-10-3 is a 3-way, 2-position, spool-type, direct acting screw-in cartridge solenoid valve, and
requires a machined cavity or housing for installation.
Fluid Conveying

Operation: In the de-energized position, this valve allows flow from port 2 to port 1 while port 3 is blocked. In the
energized position, flow is allowed from port 1 to port 3 while port 2 is blocked.
Pressure Rating (All Ports): 3000 PSI.
Rated Flow: 6 GPM.
Internal Leakage: 10 in³ per minute maximum @ 3000 PSI.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Temperature Range: -40°F to 248°F (Extreme Limits).
Miscellaneous Products

Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.


Cartridge: Model SV1-10-3*, sold separately.
Housing: Cavity size C-10-3, sold separately, see page 411
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coil: "J" Series 20 Watt, sold separately, see page 414
3-way, 2-position Solenoid Valves • Vickers® SV1-10-3 Series • To 6 GPM & 3000 PSI
Catalog Vickers Manual Override Seal Price
Part No. Part No. Vickers Model Option Housing Coil (1 Required) Material Wt. Each
•C1BT28 565546 SV1-10-3-0-00 No None None Buna-N 0.32
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
330
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type

Hydraulic Power & Control


4-way, 2-position Solenoid Valves
Vickers® SV1-8-4 Series • To 3 GPM & 3000 PSI

Pneumatic Power & Control


Fluid Conveying
Description: This is a 4-way 2-position, direct acting, spool type solenoid valve. This valve can be used in
applications where the motion of a double acting cylinder or a motor needs to be reversed.
Operation: In the de-energized position this valve allows flow from port 4 to port 1 and from port 3 to port 2. In the
energized position flow is allowed from port 3 to port 4 and from port 2 to port 1.
Pressure Rating (All Ports): 3000 PSI.
Rated Flow: 3 GPM.
Internal Leakage: 5 in³/min max @ 3000 psi.

Miscellaneous Products
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Temperature Range: -40° to 248°F.
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV1-8-4*, sold separately.
Housing: Cavity size C-8-4, sold separately, see page 413
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coil: "S" Series 20 W, sold separately, see page 414
4-way, 2-position Solenoid Valves • Vickers® SV1-8-4 Series • To 3 GPM & 3000 PSI
Catalog Manual Override Seal Price
Part No. Vickers Part No. Vickers Model Option Housing Seal Coil (1 Required) Material Wt. Each
C1MF98 02-160773 SV1-8-4-0-00 None None None Buna-N
Indexes & Technical Information
Note: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
331
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type
Hydraulic Power & Control

4-way, 2-position Solenoid Valves


Vickers® SV1-10-4 Series • To 6 GPM & 3000 PSI
Pneumatic Power & Control
Fluid Conveying

Description: The SV1-10-4 is a 4-way, 2-position, spool-type, direct acting screw-in cartridge solenoid valve, and
requires a machined cavity or housing for installation.
Operation: In the de-energized position, this valve allows flow from port 2 to port 3 and from port 4 to port 1. In the
energized position, flow is allowed from port 3 to port 4 and from port 2 to port 1.
Miscellaneous Products

Pressure Rating (All Ports): 3000 PSI.


Rated Flow: 6 GPM.
Internal Leakage: 10 in³ per minute maximum @ 3000 PSI.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV1-10-4*, sold separately.
Housing: Cavity size C-10-4, sold separately, see page 413
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coil: "J" Series 20 Watt, sold separately, see page 414
Indexes & Technical Information

4-way, 2-position Solenoid Valves • Vickers® SV1-10-4 Series • To 6 GPM & 3000 PSI
Catalog Vickers Manual Override Seal Price
Part No. Part No. Vickers Model Option Housing Coil (1 Required) Material Wt. Each
•C1BT29 565547 SV1-10-4-0-00 No None None Buna-N 0.36
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
332
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type

Hydraulic Power & Control


4-way, 3-position Solenoid Valves
Vickers® SV9-8 Series • To 3.5 GPM & 3000 PSI

Pneumatic Power & Control


Fluid Conveying
Miscellaneous Products
Description: The SV9-10 is a 4-way, 3-position, spool-type, direct acting screw-in cartridge solenoid valve, and
requires a machined cavity or housing for installation.
Operation: Closed Center Valves: In the de-energized position, all ports are blocked. When solenoid 1 is
energized, flow is directed from port 3 to port 2 and from port 4 to port 1. When solenoid 2 is energized, flow is
directed from port 3 to port 4 and from port 2 to port 1. Tandem Center Valves: In the de-energized position,
this valve allows flow from 3 to port 1 and blocks ports 2 and 4. When solenoid 1 is energized, flow is directed
from port 3 to port 2 and from port 4 to port 1. When solenoid 2 is energized, flow is directed from port 3 to port
4 and from port 2 to port 1.
Pressure Rating (All Ports): 3000 PSI.
Rated Flow: Tandem Center models 3 GPM, Others 3.5 GPM.
Internal Leakage: 10 in³ per minute maximum @ 3000 PSI. Indexes & Technical Information
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV9-8*, sold separately.
Housing: Cavity size C-8-4, sold separately. Aluminum NFPA fatigue rated models: 02-160749 SAE-6 Ports,
02-160750 SAE-8 Ports. See page 413
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coils: "P" Series 20 Watt, sold separately, see page 414

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
333
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type
Hydraulic Power & Control

4-way, 3-position Solenoid Valves • Vickers® SV9-8 Series • To 3.5 GPM & 3000 PSI
Catalog Vickers Seal Price
Part No. Part No. Vickers Model Circuit Type Housing Coils (2 Required) Material Wt. Each

C1HW91 02-198685 VICK SV98NF00000000000000 P Blocked, A&B None None Buna-N 0.50
Open
Note: (1ea) 02-186730 Spacer is REQUIRED to assemble a valve. (Select from table below).

Parts for Vickers® SV9-8 Solenoid Valve Cartridges


Catalog Price
Part No. Part Number Description Wt. Each
C1HW46 02-186730 Spacer (To be inserted between the coils - REQUIRED) 0.06
Pneumatic Power & Control
Fluid Conveying
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
334
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type

Hydraulic Power & Control


4-way, 3-position Solenoid Valves
Vickers® SV9-10 Series • To 6 GPM & 3000 PSI

Pneumatic Power & Control


Fluid Conveying
Description: The SV9-10 is a 4-way, 3-position, spool-type, direct acting screw-in cartridge solenoid valve, and
requires a machined cavity or housing for installation.
Operation: Closed Center Valves: In the de-energized position, all ports are blocked. When solenoid 1 is
energized, flow is directed from port 3 to port 2 and from port 4 to port 1. When solenoid 2 is energized, flow is
directed from port 3 to port 4 and from port 2 to port 1. Tandem Center Valves: In the de-energized position,

Miscellaneous Products
this valve allows flow from 3 to port 1 and blocks ports 2 and 4. When solenoid 1 is energized, flow is directed
from port 3 to port 2 and from port 4 to port 1. When solenoid 2 is energized, flow is directed from port 3 to port
4 and from port 2 to port 1.
Pressure Rating (All Ports): 3000 PSI.
Rated Flow: Tandem Center models 5 GPM, Others 6 GPM.
Internal Leakage: 15 in³ per minute maximum @ 3000 PSI.
Note: Performance data is typical with fluid at 105 SSU and 120°F.
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model SV9-10*, sold separately.
Indexes & Technical Information
Housing: Cavity size C-10-4, sold separately, see page 413
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Coils: "J" Series 20 Watt, sold separately, see page 414
4-way, 3-position Solenoid Valves • Vickers® SV9-10 Series • To 6 GPM & 3000 PSI
Catalog Vickers Part Seal Price
Part No. No. Vickers Model Circuit Type Housing Coils (2 Required) Material Wt. Each
C1LX25 403AA01052A SV9A-10-N-A-0-0-00 Tandem Center None None Buna-N
•C1KY86 02-199325 SV910NA00000000000000A Tandem Center None None Buna-N 0.53
C1LX26 403AA01054A SV9A-10-N-B-0-0-00 Open Center None None Buna-N
C1MG48 403AA01056A SV9A-10-N-E-0-0-00 Closed Center None None Buna-N
P Blocked, A&B
C1KX60 02-199329 SV910NF00000000000000A Open to Tank None None Buna-N 0.53

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
335
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • Screw-In Cartridge Type
Hydraulic Power & Control

Note: (1ea) 02-179226 Spacer is REQUIRED to assemble a valve (Select from table below).

Parts for Vickers® SV9-10 Solenoid Valve Cartridges


Catalog Price
Part No. Part Number Description Wt. Each
•C1AD39 02-179226 Spacer (To be inserted between the coils - REQUIRED) 0.06
Pneumatic Power & Control
Fluid Conveying
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
336
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • NFPA Size D03 • ISO 4401 Size 03

Hydraulic Power & Control


Vickers DG4V-3 & DG4V-3S Series

Vickers® DG4V-3S (Standard Performance) • Flows to 10.5 GPM


DG4V-3 (High Performance) • Flows to 21 GPM
Features: High reliability. High pressure & flow capability. Low pressure drops.
Viton® seals. Scratch-proof manual override. Coil change with valve in place. ISO
4401 Size 03, NFPA D03 port interface.
Maximum Operating Pressure: 5075 psi. (CAUTION: Pressures over 3000 PSI
require steel subplate or manifold). (See tables for port T pressure rating).
Maximum Flow Rates: Dependent on spool/spring combination and coil.

Pneumatic Power & Control


Operating Fluid Temperature Range: -4°F to 158°F (Mineral oil), +50°F to 129°F (water based fluids).
Ambient Temperature Range:
DG4V-3S: 4°F to 149°F (Dual freq. Coil @110% voltage).
DG4V-3: -4°F to 122°F (Dual freq. coil @107% voltage), -4°F to 104°F (Dual freq. coil @ 110% voltage).
Mounting Considerations: Detented models should mount with longitudinal axis horizontal. Other models may
be mounted in any position.
Service Parts: page 341
Technical Information: page 626
Note: These valves are available in a wide variety of configurations not shown in this catalog. Contact us for
detailed information.
Size D03 Subplates & Manifolds: page 418
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).

Fluid Conveying
Mounting Bolts: Standard mounting bolts are 4ea 10-24 x 1-1/4 Grade 8 socket head capscrews (Vickers Bolt Kit
590716), torqued to 44-62 lb.in. with threads lubricated. See Bolt Kits on page 409

4-way, 3-position, Spring Centered


Spool / Spring Code 2C
Transient conditions during shift: P to A: All blocked. P to B: All blocked.
Maximum Flow Rates @ 3000 PSI:

Miscellaneous Products
Standard Performance: AC Coils 10 GPM, DC Coils 8 GPM.
High Performance: AC Coils 16 GPM, DC Coils 21 GPM.

4-way, 3-position, Spring Centered • Spool / Spring Code 2C


Port T
Catalog Vickers Rating Optional Price
Part No. Part No. Vickers Model Type Coil Rating Coil Type (psi) Features Wt. Each
110VAC50Hz
C1AC46 02-109686 DG4V-3S-2C-M-U-B5-60 STD 120VAC60Hz DIN 43650 1500 4.25
110VAC50Hz Lead wires
•C1AC42 02-109575 DG4V-3S-2C-M-FW-B5-60 STD 120VAC60Hz Conduit box 1500 4.25

220VAC50Hz Indexes & Technical Information


C1JS96 02-109026 DG4V-3S-2C-M-U-D5-60 STD 240VAC60Hz DIN 43650 1500 4.05
•C1AC37 02-109055 DG4V-3S-2C-M-U-G5-60 STD 12VDC DIN 43650 1500 4.70

C1LA85 02-109943 DG4V-3S-2C-H-M-U-G5-60 STD 12VDC DIN 43650 1500 Water-resist


ant override
•C1AC49 02-109826 DG4V-3S-2C-M-FW-G5-60 STD 12VDC Lead wires 1500 4.83
Conduit box
•C1AC31 02-109025 DG4V-3S-2C-M-U-H5-60 STD 24VDC DIN 43650 1500 4.68
C1KD96 859161 DG4V-3-2C-M-U-B6-60 HP 110VAC50Hz DIN 43650 3000 4.13
120VAC60Hz
C1KD98 859172 DG4V-3-2C-M-U-D6-60 HP 220VAC50Hz DIN 43650 3000 4.00
240VAC60Hz
C1BS80 529760 DG4V-3-2C-M-U-H7-60 HP 24VDC DIN 43650 3000 4.79

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
337
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • NFPA Size D03 • ISO 4401 Size 03
Hydraulic Power & Control

Vickers DG4V-3 & DG4V-3S Series

4-way, 3-position, Spring Centered


Spool / Spring Code 8C
Transient conditions during shift: P to A: P & A restricted opening to T, B blocked.
P to B: P & B restricted opening to T, A blocked.
Maximum Flow Rates @ 3000 PSI:
Standard Performance: AC Coils 3 GPM, DC Coils 2.5 GPM.
High Performance: AC Coils 9 GPM, DC Coils 12 GPM.
4-way, 3-position, Spring Centered • Spool / Spring Code 8C
Pneumatic Power & Control

Port T
Catalog Vickers Rating Optional Price
Part No. Part No. Vickers Model Type Coil Rating Coil Type (psi) Features Wt. Each

C1AC96 02-145188 DG4V-3S-8C-VM-U-B5-61 STD 110VAC50Hz DIN 43650 1500 3.00


120VAC60Hz
•C1AC93 02-145150 DG4V-3S-8C-VM-FW-B5-61 STD 110VAC50Hz Lead wires 1500 4.25
120VAC60Hz Conduit box
C1JP87 02-144939 DG4V-3S-8C-VM-U-D5-61 STD 220VAC50Hz DIN 43650 1500 4.05
240VAC60Hz
•C1AC97 02-145190 DG4V-3S-8C-VM-U-G5-61 STD 12VDC DIN 43650 1500 4.68

•C1AC95 02-145182 DG4V-3S-8C-VM-FW-G5-61 STD 12VDC Lead wires 1500 5.00


Conduit box
•C1AC98 02-145192 DG4V-3S-8C-VM-U-H5-61 STD 24VDC DIN 43650 1500 5.00
110VAC50Hz
Fluid Conveying

C1JT71 02-144938 DG4V-3-8C-VM-U-B6-61 HP 120VAC60Hz DIN 43650 3000 4.11


110VAC50Hz Lead wires
C1AC94 02-145158 DG4V-3-8C-VM-FW-B6-61 HP 120VAC60Hz Conduit box 3000 4.20

C1JT72 02-144943 DG4V-3-8C-VM-U-D6-61 HP 220VAC50Hz DIN 43650 3000 4.12


240VAC60Hz

4-way, 3-position, Spring Centered


Miscellaneous Products

Spool / Spring Code 6C


Transient conditions during shift: P to A: P & A blocked, B open to T. P to B: P &
B blocked, A open to T.
Maximum Flow Rates @ 3000 PSI:
Standard Performance: AC Coils 5 GPM, DC Coils 3.5 GPM.
High Performance: AC Coils 5 GPM, DC Coils 9 GPM.
4-way, 3-position, Spring Centered • Spool / Spring Code 6C
Port T
Catalog Vickers Rating Optional Price
Part No. Part No. Vickers Model Type Coil Rating Coil Type (psi) Features Wt. Each
Indexes & Technical Information

110VAC50Hz
C1AC48 02-109824 DG4V-3S-6C-M-U-B5-60 STD 120VAC60Hz DIN 43650 1500 4.02

•C1AC41 02-109573 DG4V-3S-6C-M-FW-B5-60 STD 110VAC50Hz Lead wires 1500 4.25


120VAC60Hz Conduit box
•C1AC36 02-109048 DG4V-3S-6C-M-U-G5-60 STD 12VDC DIN 43650 1500 4.68

•C1AC43 02-109628 DG4V-3S-6C-M-FW-G5-60 STD 12VDC Lead wires 1500 4.80


Conduit box
•C1AC35 02-109047 DG4V-3S-6C-M-U-H5-60 STD 24VDC DIN 43650 1500 4.75

C1KD99 859176 DG4V-3-6C-M-U-B6-60 HP 110VAC50Hz DIN 43650 3000 4.12


120VAC60Hz
C1KE20 859726 DG4V-3-6C-M-U-D6-60 HP 220VAC50Hz DIN 43650 3000 4.10
240VAC60Hz
C1KB62 565465 DG4V-3-6C-M-U-H7-60 HP 24VDC DIN 43650 3000 4.87

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
338
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • NFPA Size D03 • ISO 4401 Size 03

Hydraulic Power & Control


Vickers DG4V-3 & DG4V-3S Series

4-way, 3-position, Spring Centered


Spool / Spring Code 0C
Transient conditions during shift: All open.
Maximum Flow Rates @ 3000 PSI:
Standard Performance: AC Coils 10.5 GPM, DC Coils 10.5 GPM.
High Performance: AC Coils 16 GPM, DC Coils 16 GPM.

Pneumatic Power & Control


4-way, 3-position, Spring Centered • Spool / Spring Code 0C
Port T
Catalog Vickers Rating Optional Price
Part No. Part No. Vickers Model Type Coil Rating Coil Type (psi) Features Wt. Each

C1AC51 02-109940 DG4V-3S-0C-M-U-B5-60 STD 110VAC50Hz DIN 43650 1500 3.00


120VAC60Hz
Lead wires
•C1AC47 02-109696 DG4V-3S-0C-M-FW-G5-60 STD 12VDC Conduit box 1500 5.00
Latching
C1GF75 02-354934 DG4V-3S-0C-Y-M-SP2-G5-60 STD 12VDC Dual 6.3mm 1500 water-resistant 4.90
spade manual overrides

•C1FE42 02-109693 DG4V-3S-0C-M-FW-H5-60 STD 24VDC Lead wires 1500 4.79


Conduit box

Fluid Conveying
Dual 6.3mm Latching
C1GF89 02-354935 DG4V-3S-0C-Y-M-SP2-H5-60 STD 24VDC spade 1500 water-resistant 4.89
manual overrides

4-way, 2-position, Spring Offset End-to-End


Spool / Spring Code 2A

Miscellaneous Products
Transient conditions during shift: All blocked.
Maximum Flow Rates @ 3000 PSI:
Standard Performance: AC Coils 7.5 GPM, DC Coils 7.5 GPM.
High Performance: AC Coils 16 GPM, DC Coils 16 GPM.

4-way, 2-position, Spring Offset End-to-End • Spool / Spring Code 2A


Port T
Catalog Vickers Rating Optional Price
Part No. Part No. Vickers Model Type Coil Rating Coil Type (psi) Features Wt. Each
110VAC50Hz
C1AC44 02-109632 DG4V-3S-2A-M-U-B5-60 STD 120VAC60Hz DIN 43650 1500 3.19

•C1AC38 02-109563 DG4V-3S-2A-M-FW-B5-60 STD 110VAC50Hz Lead wires 1500 3.50


Indexes & Technical Information
120VAC60Hz Conduit box
C1JP80 02-109642 DG4V-3S-2A-M-U-D5-60 STD 220VAC50Hz DIN 43650 1500 3.20
240VAC60Hz
C1AC32 02-109030 DG4V-3S-2A-M-U-H5-60 STD 24VDC DIN 43650 1500 3.75
C1CA43 859159 DG4V-3-2A-M-U-B6-60 HP 110VAC50Hz DIN 43650 3000 3.24
120VAC60Hz
C1BS81 529762 DG4V-3-2A-M-U-H7-60 HP 24VDC DIN 43650 3000 3.57
Left Hand Build Models: Solenoid is on opposite side of valve body. De-Energized state is P to B, A to T.

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
339
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • NFPA Size D03 • ISO 4401 Size 03
Hydraulic Power & Control

Vickers DG4V-3 & DG4V-3S Series

4-way, 2-position, Spring Offset End-to-End


Spool / Spring Code 0A
Transient conditions during shift: All open.
Maximum Flow Rates @ 3000 PSI:
Standard Performance: AC Coils 10.5 GPM, DC Coils 10 GPM.
High Performance: AC Coils 16 GPM, DC Coils 16 GPM.

4-way, 2-position, Spring Offset End-to-End • Spool / Spring Code 0A


Pneumatic Power & Control

Port T
Catalog Vickers Rating Optional Price
Part No. Part No. Vickers Model Type Coil Rating Coil Type (psi) Features Wt. Each
110VAC50Hz
C1AC82 02-137934 DG4V-3S-0A-M-U-B5-60 STD 120VAC60Hz DIN 43650 1500 3.25
Fluid Conveying

Miscellaneous Spool / Spring Code Valves


Miscellaneous Products

Miscellaneous Spool / Spring Code Valves


Max Flow @
Spool Port T 3000 PSI,
Catalog Vickers Spring Rating Optional Price
Part No. Part No. Vickers Model Code Type Coil Rating Coil Type (psi) Features Wt. Each
16 GPM,
Indexes & Technical Information

C1KE43 869777 DG4V-3-0BL-M-U-H7-60 0B HP 24VDC DIN 43650 3000 Left Hand 3.56
Build
Left Hand Build Models: Solenoid is on opposite side of valve body.

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
340
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • NFPA Size D03 • ISO 4401 Size 03

Hydraulic Power & Control


Vickers DG4V-3 & DG4V-3S Series

Vickers DG4V-3 & DG4V-3S Series Parts

Pneumatic Power & Control


Vickers DG4V-3 & DG4V-3S Series Parts
Catalog Price
Part No. Vickers Model Description Wt. Each
Coil. 110VAC 50HZ, 120VAC 60HZ. HP models with Din 43650 Connector. (Connector is
C1BS37 507833 required) 0.63

•C1AB99 02-101726 Coil. 110VAC 50HZ, 120VAC 60HZ. STD models with Din 43650 Connector. (Connector is 0.60
required)
•C1AC12 02-101731 Coil. 110VAC 50HZ, 120VAC 60HZ. STD models with Lead Wire. 0.57
•C1AC11 02-101728 Coil. 220VAC 50HZ, 240VAC 60HZ. STD models with Din 43650 Connector. (Connector is 0.60
required)
•C1AC13 02-101733 Coil. 220VAC 50HZ, 240VAC 60HZ. STD models with Lead Wire. 0.60
C1BS38 507834 Coil. 220VAC 50HZ, 240VAC 60HZ. High Performance models with Din 43650 Connector. 0.50
(Connector is required)
•C1BS39 507847 Coil. 12VDC. STD & HP models with Din 43650 Connector. (Connector is required) 0.88

Fluid Conveying
•C1BS44 508172 Coil. 12VDC. STD & HP models with Lead Wire. 0.88
•C1BS40 507848 Coil. 24VDC. STD & HP models with Din 43650 Connector. (Connector is required) 0.89
•C1BS45 508173 Coil. 24VDC. STD & HP models with Lead Wire. 0.87
•C1BY36 694302 Nameplate, blank. Standard Performance Models with Din 43650 Coil. 0.10
C1HH88 262332 O-Ring, Valve to Mounting Surface, 4 per valve 0.01
•C1CA41 858995 Seal Kit for models with Din 43650 coils. 0.10
•C1BS52 5100-10900 DIN 43650 Solenoid Connector, Strain Relief Style for cable diameter 0.24 to 0.31, not wired, 0.25
no light

Miscellaneous Products
DIN 43650 Solenoid Connector, Strain Relief Style for cable diameter 0.31 to 0.41, not wired,
•C1FK20 5103-1090000 light for 6-48 VAC/VDC 50/60 Hz 0.05
C1ZX22 617119 Spool, 6B/6C/6F 0.07

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
341
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • NFPA Size D03 • ISO 4401 Size 03
Hydraulic Power & Control

Vickers DG4V-3 Series (Soft Shift, Non-Tuneable Fixed Orifice)

DG4V-3 Soft Shift (High Performance) • Flows to 22 GPM


Non-Tuneable Fixed Orifice
Features: Low cost alternative to proportional valves. "Non-Tuneable" fixed shift
orifices for lower cost. Conventional direct-acting solenoid design with controlled
solenoid shift speed. Wet Armature design for quieter operation and long life with no
dynamic seal leakage. Molded coil is impervious to moisture & dirt. Viton® seals
standard.
Operating Principles: Spools with contoured or notched lands are used to provide maximum control of flow rate
Pneumatic Power & Control

change as the spool is shifted. DC solenoids prevent coil burnout during controlled rate of solenoid shift. Spool
shift speed is controlled by a fixed, non-serviceable metering orifice in the solenoid. P12L Models: Conventional
alternating current (120VAC 60HZ or 110VAC 50HZ) input is converted to DC through a rectifier located in the
valve's terminal box. Models other than P12L: Rectified DIN connectors can be used to convert AC input voltage
to the DC voltage necessary to power the valve.
Maximum Operating Pressure: Ports P, A & B 5075 PSI, Port T 3045 PSI, with petroleum oil (1000 PSI with High
Water Base fluids). (CAUTION: Pressures over 3000 PSI require steel subplate or manifold).
Maximum Flow Rates: Dependant on spool/spring combination and coil.
Recommended Operating Temperature Range: 20°F to 180°F.
Plumbing Note: To fully utilize the features of the soft shift solenoid, the core tubes must remain full of oil. The
tank line must be plumbed so that the tank port is always flooded with oil. Addition of a back pressure check
may be required to prevent bleed down.
Fluid Conveying

Bleeding Procedure: Apply a minimum of 50 PSI tank pressure. Shift either solenoid. Loosen manual actuators
in solenoid ends until air is evacuated. Tighten manual actuators. No further bleeding should be required.
Technical Information: page 628
Note: These valves are available in a wide variety of configurations not shown in this catalog. Contact us for
detailed information.
Size D03 Subplates & Manifolds: page 418
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Mounting Bolts: Standard mounting bolts are 4ea 10-24 x 1-1/4 Grade 8 socket head capscrews (Vickers Bolt Kit
Miscellaneous Products

590716), torqued to 44-62 lb.in. maximum with threads lubricated. See Bolt Kits on page 409
Valve Port Restrictor Plugs: Restrictor plugs are available for use in ports P, T, A or B. These can be used for
restricting flow or for circuit dampening. Restrictor plugs are not recommended for use above 3000 PSI.

4-way, 3-position, Spring Centered


Spool / Spring Code 2C
Transient conditions during shift: P to A all blocked. P to B all blocked.
Maximum Flow Rates @ 3000 PSI: 22 GPM.
Indexes & Technical Information

4-way, 3-position, Spring Centered • Spool / Spring Code 2C


Catalog Valve's Electrical Input Electrical Optional Price
Part No. Vickers Part No. Vickers Model Features Requirements Features Wt. Each
C1JL59 02-363653 DG4V-3-2C3-M-U-HH7-60 DIN 43650 Coils 24VDC 4.98

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
342
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • NFPA Size D03 • ISO 4401 Size 03

Hydraulic Power & Control


Vickers DG4V-3 Series (Soft Shift, Non-Tuneable Fixed Orifice)

4-way, 3-position, Spring Centered


Spool / Spring Code 6C
Transient conditions during shift: P to A P & A blocked, B open to T. P to B P & B
blocked, A open to T.
Maximum Flow Rates @ 3000 PSI: 8 GPM.

4-way, 3-position, Spring Centered • Spool / Spring Code 6C

Pneumatic Power & Control


Catalog Valve's Electrical Input Electrical Optional Price
Part No. Vickers Part No. Vickers Model Features Requirements Features Wt. Each
C1GE52 02-391668 DG4V-3-6C3-M-U-HH7-60 DIN 43650 Coils 24VDC 4.60

Fluid Conveying
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
343
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • NFPA Size D05 • ISO 4401 Size 05
Hydraulic Power & Control

Vickers DG4S4-01 60 Series (Wet Armature)

Vickers® DG4S4-01 60 Series (Wet Armature) • Flows to 25 GPM


Features: Wet Armature design for quieter operation and long life with no dynamic seal
leakage. Molded coil is impervious to moisture & dirt. Buna-N seals standard (Viton®
available). Direct Acting type.
Maximum Operating Pressure: Ports P, A & B 3600 PSI with petroleum oil, 1000 PSI
with High Water Base fluids. (CAUTION: Pressures over 3000 PSI require steel
subplate or manifold). Port T 1000 PSI.
Maximum Flow Rates: Dependant on spool/spring combination and coil. See Technical Information section.
Pneumatic Power & Control

Recommended Operating Temperature Range: 70°F to 120°F.


Mounting Considerations: Detented models should mount with longitudinal axis horizontal. Other models may
be mounted in any position.
Service Parts: page 347
Technical Information: page 629
Note: These valves are available in a wide variety of configurations not shown in this catalog. Contact us for
detailed information.
Size D05 Subplates & Manifolds: page 420
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Mounting Bolts: Standard mounting bolts are 4ea 1/4-20 x 1-1/2 Grade 8 socket head capscrews (Vickers Bolt Kit
255633), torqued to 112 lb.in. maximum with threads lubricated. See Bolt Kits on page 409

4-way, 3-position, Spring Centered


Fluid Conveying

Spool / Spring Code 2C


Transient conditions during shift: P to A: All blocked. P to B: All blocked.
Maximum Flow Rates @ 3000 PSI: AC Coils 25 GPM, DC Coils 25 GPM.
Miscellaneous Products

4-way, 3-position, Spring Centered • Spool / Spring Code 2C


Catalog Wiring Optional Price
Part No. Vickers Part No. Vickers Model Coil Rating Coil Type Housing Features Wt. Each

C1JR98 879237 DG4S4-012C-U-B-60 110VAC50Hz DIN 43650 -- 10.19


120VAC60Hz
•C1CA57 879135 DG4S4-012C-B-60 110VAC50Hz Lead wires None 10.12
120VAC60Hz
•C1AC56 02-119593 DG4S4-012C-G-60 12VDC Lead wires None 13.62
C1HJ85 879239 DG4S4-012C-U-H-60 24VDC DIN 43650 -- 13.58
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
344
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • NFPA Size D05 • ISO 4401 Size 05

Hydraulic Power & Control


Vickers DG4S4-01 60 Series (Wet Armature)

4-way, 3-position, Spring Centered


Spool / Spring Code 8C
Transient conditions during shift: P to A: P & A restricted opening to T, B blocked.
P to B: P & B restricted opening to T, A blocked.
Maximum Flow Rates @ 3000 PSI: AC Coils 12 GPM, DC Coils 5 GPM.

4-way, 3-position, Spring Centered • Spool / Spring Code 8C

Pneumatic Power & Control


Catalog Wiring Optional Price
Part No. Vickers Part No. Vickers Model Coil Rating Coil Type Housing Features Wt. Each
110VAC50Hz
C1JP86 02-119859 DG4S4-018C-U-B-60 120VAC60Hz DIN 43650 -- 10.50
110VAC50Hz
•C1CA61 880002 DG4S4-018C-B-60 120VAC60Hz Lead wires None 10.11
220VAC50Hz
C1JT48 02-127608 DG4S4-018C-U-D-60 240VAC60Hz DIN 43650 -- 10.20
•C1EL31 02-119489 DG4S4-018C-G-60 12VDC Lead wires None 13.75
C1JT44 02-126361 DG4S4-018C-U-H-60 24VDC DIN 43650 -- 13.50

4-way, 3-position, Spring Centered

Fluid Conveying
Spool / Spring Code 6C
Transient conditions during shift: P to A: P & A blocked, B open to T. P to B: P & B
blocked, A open to T.
Maximum Flow Rates @ 3000 PSI: AC Coils 20 GPM, DC Coils 20 GPM.

Miscellaneous Products
4-way, 3-position, Spring Centered • Spool / Spring Code 6C
Catalog Wiring Optional Price
Part No. Vickers Part No. Vickers Model Coil Rating Coil Type Housing Features Wt. Each

C1JT32 02-119475 DG4S4-016C-U-B-60 110VAC50Hz DIN 43650 -- 10.21


120VAC60Hz
C1CA58 879159 DG4S4-016C-B-60 110VAC50Hz Lead wires None 10.16
120VAC60Hz
220VAC50Hz
C1JT43 02-126360 DG4S4-016C-U-D-60 240VAC60Hz DIN 43650 -- 10.10

C1EL30 02-119461 DG4S4-016C-U-H-60 24VDC DIN 43650 -- 13.58

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
345
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • NFPA Size D05 • ISO 4401 Size 05
Hydraulic Power & Control

Vickers DG4S4-01 60 Series (Wet Armature)

4-way, 3-position, Spring Centered


Spool / Spring Code 0C
Transient conditions during shift:
Maximum Flow Rates @ 3000 PSI: AC Coils 25 GPM, DC Coils 25 GPM.

4-way, 3-position, Spring Centered • Spool / Spring Code 0C


Pneumatic Power & Control

Catalog Wiring Optional Price


Part No. Vickers Part No. Vickers Model Coil Rating Coil Type Housing Features Wt. Each
110VAC50Hz
•C1CA59 879242 DG4S4-010C-B-60 120VAC60Hz Lead wires None 10.10
C1JT40 02-126196 DG4S4-010C-U-H-60 24VDC DIN 43650 -- 13.50

4-way, 2-position, Spring Offset End-to-Center


Spool / Spring Code 2B
Transient conditions during shift:
Maximum Flow Rates @ 3000 PSI: AC Coils 25 GPM, DC Coils 25 GPM.
Fluid Conveying

4-way, 2-position, Spring Offset End-to-Center • Spool / Spring Code 2B


Catalog Wiring Optional Price
Part No. Vickers Part No. Vickers Model Coil Rating Coil Type Housing Features Wt. Each
C1GH29 02-336791 DG4S4-012B-U-G-60 12VDC DIN 43650 -- 10.03
Miscellaneous Products

4-way, 2-position, Spring Offset End-to-End


Spool / Spring Code 2A
Transient conditions during shift: All blocked.
Maximum Flow Rates @ 3000 PSI: AC Coils 20 GPM, DC Coils 20 GPM.

4-way, 2-position, Spring Offset End-to-End • Spool / Spring Code 2A


Indexes & Technical Information

Catalog Wiring Optional Price


Part No. Vickers Part No. Vickers Model Coil Rating Coil Type Housing Features Wt. Each

C1KE86 879279 DG4S4-012A-U-B-60 110VAC50Hz DIN 43650 -- 8.42


120VAC60Hz
•C1CA60 879249 DG4S4-012A-B-60 110VAC50Hz Lead wires None 8.42
120VAC60Hz
C1HJ86 879260 DG4S4WT-012A-B-60 110VAC50Hz Lead wires Yes Terminal Strip 9.87
120VAC60Hz
220VAC50Hz
C1KE87 879280 DG4S4-012A-U-D-60 240VAC60Hz DIN 43650 -- 83.00

C1KE40 868978 DG4S4-012A-U-H-60 24VDC DIN 43650 -- 10.66

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
346
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • NFPA Size D05 • ISO 4401 Size 05

Hydraulic Power & Control


Vickers DG4S4-01 60 Series (Wet Armature)

Vickers DG4S4-01 60 Series (Wet Armature) Parts

Pneumatic Power & Control


Vickers DG4S4-01 60 Series (Wet Armature) Parts
Catalog Price
Part No. Vickers Part No. Description Wt. Each
•C1DZ91 879141 Coil, DIN 43650 Type. 110VAC 50HZ, 120VAC 60HZ. Connector is required. 1.24
C1KE81 879143 Coil, DIN 43650 Type. 220VAC 50HZ, 240VAC 60HZ. Connector is required. 1.30
•C1CA47 868982 Coil, Lead Wire Type. 110VAC 50HZ, 120VAC 60HZ. 1.30
C1FL31 868983 Coil, Lead Wire Type. 220VAC 50HZ, 240VAC 60HZ. 1.30
DIN 43650 Solenoid Connector, Strain Relief Style for cable diameter 0.24 to 0.31, not wired,
•C1BS52 5100-10900 no light 0.25

•C1FK20 5103-1090000 DIN 43650 Solenoid Connector, Strain Relief Style for cable diameter 0.31 to 0.41, not wired, 0.05
light for 6-48 VAC/VDC 50/60 Hz

Fluid Conveying
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
347
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • NFPA Size D05 • ISO 4401 Size 05
Hydraulic Power & Control

Vickers DG4V4-01 10 Series (Wet Armature, High Pressure)

Vickers® DG4V4-01 10 Series (Wet Armature, High Pressure) • To 30 GPM


Features: High pressure & flow capability. Plug-in solenoid coils for ease of servicing.
Spool cushioning passage equalizes hydraulic force on ends of spool and cushions
spool shift. Wet Armature design for quieter operation and long life with no dynamic
seal leakage. Molded coil is impervious to moisture & dirt. Buna-N seals standard
(Viton® available). Direct Acting type.
Maximum Operating Pressure: Ports P, A & B 4570 PSI with petroleum oil, 1000 PSI with High Water Base
fluids. (CAUTION: Pressures over 3000 PSI require steel subplate or manifold). Port T 1750 PSI with Standard
Pneumatic Power & Control

Power coils, 1000 PSI with Low Power Coils.


Maximum Flow Rates: Dependant on spool/spring combination and coil.
Recommended Operating Temperature Range: 70°F to 120°F.
Mounting Considerations: Detented models should mount with longitudinal axis horizontal. Other models may
be mounted in any position.
Note: These valves are available in a wide variety of configurations not shown in this catalog. Contact us for
detailed information.
Size D05 Subplates & Manifolds: page 420
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Mounting Bolts: Standard mounting bolts are 4ea 1/4-20 x 1-1/2 Grade 8 socket head capscrews (Vickers Bolt Kit
255633), torqued to 112 lb.in. maximum with threads lubricated. See Bolt Kits on page 409
Dimensions & Technical Information: page 632
Fluid Conveying

4-way, 3-position, Spring Centered


Spool / Spring Code 2C
Transient conditions during shift: All blocked.
Maximum Flow Rates @ 3000 PSI: Standard AC Coils 30 GPM, Low Powered AC
Coils 20 GPM. Standard DC Coils 30 GPM, Low Powered DC Coils 15 GPM (1500
PSI limit).
Miscellaneous Products

4-way, 3-position, Spring Centered • Spool / Spring Code 2C


Catalog Wiring Optional Price
Part No. Vickers Part No. Vickers Model Coil Rating Coil Type Housing Features Wt. Each
C1GH30 02-339884 DG4V4-012C-M-U-G-5-10 12VDC DIN 43650 -- Std. Power Coils 13.62

4-way, 2-position, Spring Offset End-to-End


Spool / Spring Code 0A
Indexes & Technical Information

Transient conditions during shift: All Open.


Maximum Flow Rates @ 3000 PSI: Standard AC Coils 30 GPM, Low Powered AC Coils 20
GPM. Standard DC Coils 30 GPM, Low Powered DC Coils 15 GPM (1500 PSI limit).

4-way, 2-position, Spring Offset End-to-End • Spool / Spring Code 0A


Catalog Wiring Optional Price
Part No. Vickers Part No. Vickers Model Coil Rating Coil Type Housing Features Wt. Each

C1HH49 02-363741 DG4V4-010A-M-W-L-B-5-10 110VAC50Hz Plug-In Yes Std. Power Coil, 9.61
120VAC60Hz Lights

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
348
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • NFPA Size D05 • ISO 4401 Size 05

Hydraulic Power & Control


Vickers DG4V5-01 20 Series (Wet Armature, High Pressure)

Vickers® DG4V5 20 Series (Wet Armature, High Pressure) • To 32 GPM


Features: Four-land spool design to facilitate smooth, variable valve response speeds •
AC and DC wet-armature solenoid options with ISO 4400 (DIN 43650) electrical
connections and manual overrides • Variable speed changeover potential in all DC
models • Many spool types; in spring-offset, spring-centered and detented
arrangements.
Maximum Operating Pressure: Ports P, A & B 4500 PSI (CAUTION: Pressures over
3000 PSI require steel subplate or manifold). Ports T 1750 PSI for AC solenoids, 2325

Pneumatic Power & Control


PSI for DC solenoids.
Maximum Flow Rates: Dependant on spool/spring combination and coil.
Fluid Temperature: -4°F to 150°F Recommended Operating Range, -4°F to 158°F Extreme Range.
Fluid Viscosity: 70 to 245 SSU Recommended Operating Range, 70 to 2300 SSU Extreme Range.
Ambient Temperature: AC 60Hz Valves: -4°F to 104°F. AC 50Hz Valves: -4°F to 122°F. DC Valves: -4°F to
158°F.
Recommended Filtration Level: ISO Cleanliness Level 20/18/15 (Up to 3050 PSI), 19/17/14 (Above 3050 PSI).
Note: Ratings based on using anti wear hydraulic fluid. For ratings on use with other fluids, contact us for
assistance.
Note: These valves are available in a wide variety of configurations not shown in this catalog. Contact us for
detailed information.
Mounting Considerations: Detented models should mount with longitudinal axis horizontal. Other models may

Fluid Conveying
be mounted in any position.
Size D05 Subplates & Manifolds: page 420
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Mounting Bolts: Standard mounting bolts are 4ea 1/4-20 x 1-1/2 Grade 8 socket head capscrews (Vickers Bolt Kit
255633), torqued to 112 lb.in. maximum with threads lubricated. See Bolt Kits on page 409
Dimensions & Technical Information: page 633

4-way, 3-position, Spring Centered

Miscellaneous Products
Spool / Spring Code 2C
Transient conditions during shift: P to A: All blocked. P to B: All blocked.
Maximum Flow Rates @ 3000 PSI: AC Coils 30 GPM, DC Coils 30 GPM.

4-way, 3-position, Spring Centered • Spool / Spring Code 2C


Catalog Price
Part No. Vickers Part No. Vickers Model Coil Rating Optional Features Wt. Each
C1KB15 459156 DG4V-5-2C-M-U-EK6-20 115VAC60Hz 9.20 Indexes & Technical Information
C1KC44 616776 DG4V-5-2CJ-M-U-H6-20 24VDC 12.40

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
349
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • NFPA Size D05 • ISO 4401 Size 05
Hydraulic Power & Control

Vickers DG4V5-01 20 Series (Wet Armature, High Pressure)

4-way, 3-position, Spring Centered


Spool / Spring Code 6C
Transient conditions during shift: P to A: P & A blocked, B open to T. P to B: P &
B blocked, A open to T.
Maximum Flow Rates @ 3000 PSI: AC Coils 10 GPM, DC Coils 12 GPM.

4-way, 3-position, Spring Centered • Spool / Spring Code 6C


Pneumatic Power & Control

Catalog Price
Part No. Vickers Part No. Vickers Model Coil Rating Optional Features Wt. Each
C1KC47 616780 DG4V-5-6CJ-M-U-H6-20 24VDC 12.30
Fluid Conveying
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
350
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • NFPA Size D05 • ISO 4401 Size 05

Hydraulic Power & Control


Vickers DG4S4-01 60 Series (Soft Shift, Wet Armature)

Vickers® DG4S4-01 60 Series (Soft Shift, Wet Armature) • Flows to 20 GPM


Features: Low cost alternative to proportional valves. Conventional direct-acting
solenoid design with controlled solenoid shift speed. Wet Armature design for quieter
operation and long life with no dynamic seal leakage. Molded coil is impervious to
moisture & dirt. Viton® seals standard.
Operating Principles: Spools with contoured or notched lands are used to provide
maximum control of flow rate change as the spool is shifted. DC solenoids prevent coil
burnout during controlled rate of solenoid shift. Spool shift speed is controlled by a metering orifice in the

Pneumatic Power & Control


solenoid. Three orifice sizes are available. Conventional alternating current (120VAC 60HZ or 110VAC 50HZ)
input is converted to DC through a rectifier located in the valve's terminal box.
Maximum Operating Pressure: Ports P, A & B 3600 PSI with petroleum oil, 1000 PSI with High Water Base
fluids. (CAUTION: Pressures over 3000 PSI require steel subplate or manifold). Port T 1000 PSI.
Maximum Flow Rates: Dependant on spool/spring combination and coil. See Technical Information section.
Recommended Operating Temperature Range: 20°F to 180°F.
Plumbing Note: To fully utilize the features of the soft shift solenoid, the core tubes must remain full of oil. The
tank line must be plumbed so that the tank port is always flooded with oil. Addition of a back pressure check
may be required to prevent bleed down.
Bleeding Procedure: Apply a minimum of 50 PSI tank pressure. Shift either solenoid. Loosen manual actuators
in solenoid ends until air is evacuated. Tighten manual actuators. No further bleeding should be required.
Technical Information: page 630

Fluid Conveying
Note: These valves are available in a wide variety of configurations not shown in this catalog. Contact us for
detailed information.
Size D05 Subplates & Manifolds: page 420
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Mounting Bolts: Standard mounting bolts are 4ea 1/4-20 x 1-1/2 Grade 8 socket head capscrews (Vickers Bolt Kit
255633), torqued to 112 lb.in. maximum with threads lubricated. See Bolt Kits on page 409

4-way, 3-position, spring centered

Miscellaneous Products
Spool / Spring Code 0C
Transient conditions during shift: P to A: All open. P to B: All open.
Maximum Flow Rate @ 3000 PSI: 16 GPM.

4-way, 3-position, spring centered • Spool / Spring Code 0C


Soft
Shift
Catalog Input Electrical Orifice Price
Part No. Vickers Part No. Vickers Model Valve's Electrical Features Requirements Dia (in) Wt. Each Indexes & Technical Information

•C1AD42 02-300110 DG4S4W-010C-BB-60-S491 1/2 NPT Terminal Box with 110VAC 50HZ 0.047 11.07
Rectifier Board 120VAC 60HZ

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
351
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • NFPA Size D05 • ISO 4401 Size 05
Hydraulic Power & Control

Vickers DG4S4-01 50 Series (Air-Gap)

Vickers® DG4S4-01 50 Series (Air-Gap) • Flows to 20 GPM


Features: Older style Direct Acting Air Gap Solenoids. (Used as a replacement part for
older equipment. New applications should use the Wet Armature 60 Series). Viton®
seals standard.
Maximum Operating Pressure: Ports P, A & B 3000 PSI. Port T 1000 PSI.
Maximum Flow Rates: Dependant on spool/spring combination and coil. See
Technical Information section.
Recommended Operating Temperature Range:
Pneumatic Power & Control

Mounting Considerations: Detented models should mount with longitudinal axis horizontal. Other models may
be mounted in any position.
Service Parts: page 352
Technical Information: page 631
Note: These valves are available in a wide variety of configurations not shown in this catalog. Contact us for
detailed information.
Size D05 Subplates & Manifolds: page 420
Mounting Bolts: Standard mounting bolts are 4ea 1/4-20 x 1-1/2 Grade 8 socket head capscrews (Vickers Bolt Kit
255633), torqued to 112 lb.in. maximum with threads lubricated. See Bolt Kits on page 409

4-way, 2-position, Spring Offset End-to-End


Spool / Spring Code 2A
Fluid Conveying

Transient conditions during shift: P to A: All blocked. P to B: All blocked.


Maximum Flow Rate @ 3000 PSI: 20 GPM (Maximum Recommended is 10 GPM).

4-way, 2-position, Spring Offset End-to-End • Spool / Spring Code 2A


Catalog Wiring Optional Price
Miscellaneous Products

Part No. Vickers Part No. Vickers Model Coil Rating Coil Type Housing Features Wt. Each

C1HJ13 290620 DG4S4-012A-H-50 115VAC60Hz Lead wires None Oil Immersed 10.64
Solenoid

Vickers DG4S4-01 50 Series (Air Gap) Parts


Vickers DG4S4-01 50 Series (Air Gap) Parts
Catalog Price
Part No. Vickers Part No. Description Wt. Each
C1JY88 316130 Coil. 115VAC 50HZ. 0.34
Indexes & Technical Information

•C1BL73 316011 Coil. 115VAC 60HZ. 0.31


C1BK16 298721 Coil. 230VAC 60HZ. 0.34

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
352
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • NFPA Size D08 • ISO 4401 Size 08

Hydraulic Power & Control


Vickers DG5V-8 Series • To 5000 PSI

Vickers® DG5V-8 Series • Flows to 185 GPM • Pressures to 5000 PSI


Features: Two-stage directional valve with integrally mounted pilot valve. Available
with a wide variety of spool and spring arrangements, electrical options, stroke and pilot
choke adjustments, integral check valves and port orifices. Solid cast iron body and
core passages for maximum strength and minimal pressure drop. High-force solenoids
and centering springs assure consistent shifting.
Maximum Operating Pressures: Ports P, A & B: 5000 PSI. (CAUTION: Pressures
over 3000 PSI require steel subplate or manifold). Port T: See tables below.

Pneumatic Power & Control


Maximum Flow Rates: Dependant on spool/spring combination and coil. See
Technical Information section.
Recommended Operating Temperature Range: 0°F to 150°F.
Mounting Considerations: Detented models should mount with longitudinal axis horizontal. Other models may
be mounted in any position.
Note: These valves are available in a wide variety of configurations not shown in this catalog. Contact us for
detailed information.
Service Parts: Pilot valve parts page 341
Technical Information: page 635
Size D08 Subplates & Manifolds:
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Mounting Bolts: Standard mounting bolts are 4ea 1/2-13 x 2-1/2 Grade 8 socket head capscrews (Vickers Bolt Kit

Fluid Conveying
255635), torqued to 700 lb.in. maximum with threads lubricated. See Bolt Kits on page 409

4-way, 3-position, Spring Centered


Spool / Spring Code 8C
Transient conditions during shift: All open.
Maximum Flow Rate: 185 GPM (At pressures to 5000 PSI).

Miscellaneous Products
4-way, 3-position, Spring Centered • Spool / Spring Code 8C
Minimum
Port T Pilot
Catalog Vickers Rating Pressure Price Indexes & Technical Information
Part No. Part No. Vickers Model Coil Rating Coil Type (psi) (psi) Other Features Wt. Each
External Pilot, Internal Drain,
C1HH47 02-343827 DG5V-8-H-8C-E-V 110VAC50Hz Lead wires 5000 75 Wired Terminal Block, Indicator 31.57
M-FTWL-B-10 120VAC60Hz Conduit box Lights, High Performance pilot
valve

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
353
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Directional Valves, Solenoid Operated • NFPA Size D10 • ISO 4401 Size 10
Hydraulic Power & Control

Vickers DG5V-10 Series • To 5000 PSI

Vickers® DG5V-10 Series • Flows to 290 GPM • Pressures to 5000 PSI


Features: This control valve package offers a wide variety of spool and spring
arrangements, pilot choke adjustments, integral check valves, pilot valve choices and
port orifices. High force solenoids and centering springs assure consistent shifting
through a wide range of pressure and silting extremes.
Maximum Operating Pressure: Ports P, A & B 5000 PSI with petroleum oil. Port T
pressure rating is 3000 PSI for external drain models, 3000 psi for internal drain models
with D03 pilot valve, and is 1450 PSI for internal drain models with D05 pilot valve (see
Pneumatic Power & Control

table below for Port T rating).


Maximum Flow Rates: Dependant on spool/spring combination and coil.
Recommended Operating Temperature Range: 0°F to 150°F.
Mounting Considerations: Detented models should mount with longitudinal axis horizontal. Other models may
be mounted in any position, provided that the pilot pressure supply is maintained as required (Spring offset
valves do not have a spring in the main spool section).
Note: These valves are available in a wide variety of configurations not shown in this catalog. Contact us for
detailed information.
Size D10 Subplates & Manifolds:
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Mounting Bolts: Standard mounting bolts are 6ea 3/4-10 x 2-3/4 Grade 8 socket head capscrews (Vickers Bolt Kit
BKDG10-636-255636), torqued to 210 lb.ft. maximum with threads lubricated. See Bolt Kits on page 409
Dimensions & Technical Information: page 636
Fluid Conveying

4-way, 3-position, Spring Centered


Spool / Spring Code 2C
Maximum Flow Rates @ 3000 PSI: 270 GPM.
Miscellaneous Products

4-way, 3-position, Spring Centered • Spool / Spring Code 2C


Minimum
Port T Pilot
Catalog Vickers Rating Pressure Price
Part No. Part No. Vickers Model Coil Rating Coil Type (psi) (psi) Other Features Wt. Each
Indexes & Technical Information

DG5V-10-S-2C-T- 110VAC50Hz Lead wires Internal Pilot, Internal Drain,


C1HH41 02-321785 M-FW-B-10 120VAC60Hz Conduit box 1450 150 Std. Performance D03 pilot
valve

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
354
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Flow Control Valves

Hydraulic Power & Control


Inline Flow Control Valves
For Hydraulic (To 12 GPM) & Pneumatic Service

Pneumatic Power & Control


Features: Tamperproof adjustment key is standard. Knurled knob is optional. Locknut is standard.
Application: Controlled flow in one direction, free flow in opposite direction. Flow adjustment can be made under
pressure. Setting can be locked with locknut. Brass valves for use in pneumatic systems and lower pressure
hydraulic systems. Steel valves for use in hydraulic systems. Pressure ratings in tables are for non-shock
service.
Materials: Body: Available in Brass, carbon steel or stainless steel. Needle: Brass on brass valves, 416 stainless
steel on steel and stainless steel valves. Backup Washer: Teflon®. Optional Knob: Aluminum. Tamper proof
Key: Cadmium plated steel. Retainer and ball: Stainless steel.
Operating Temperature Range: -15°F to 200°F.
Inline Flow Control Valves • For Hydraulic (To 12 GPM) & Pneumatic Service

Fluid Conveying
Maximum
Operating
Pressure Flow
Catalog Body Non-Shock Rating CV A B C Price
Part No. Deltrol Model Size Threads Material (psi) (GPM) Factor (in) (in) (in) Wt. Each
•C1CP34 F10B 1/8 1/8-27 NPT Brass 2000 1.5 0.20 0.69 0.88 0.20 0.22
•C1CP38 F20B 1/4 1/4-18 NPT Brass 2000 3.0 0.43 0.88 1.00 0.36 0.43
•C1CP39 F20S 1/4 1/4-18 NPT Steel 5000 3.0 0.43 0.88 1.00 0.36 0.43
•C1CP46 F25B 3/8 3/8-18 NPT Brass 2000 5.0 0.78 1.06 1.81 0.34 0.73

Miscellaneous Products
•C1CP47 F25S 3/8 3/8-18 NPT Steel 5000 5.0 0.78 1.06 1.81 0.34 0.67
•C1CP50 F30S 1/2 1/2-14 NPT Steel 5000 8.0 1.24 1.31 1.44 0.47 1.18
Note: Models with K at end of model number have knurled adjustment knob instead of tamperproof adjustment key.

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
355
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Flow Control Valves
Hydraulic Power & Control

Inline Easy Read® Flow Control Valves


For Hydraulic (To 55 GPM) & Pneumatic Service
Pneumatic Power & Control

Features: Color coding and numerical readout allow positive, precise and repeatable settings. Can be accurately
adjusted within a small fraction of a turn (one full turn per color). Metal knob and stem for durability.
Application: Controlled flow in one direction, free flow in opposite direction. Flow adjustment can be made under
pressure. Setting can be locked with set screw. Brass valves for use in pneumatic systems and lower pressure
hydraulic systems. Steel valves for use in hydraulic systems. Pressure ratings in tables are for non-shock
service.
Materials: Body: Available in Brass, carbon steel or stainless steel (1" size available in naval bronze or ductile
iron). Needle: Brass on brass valves, stainless steel on steel and stainless steel valves. O-Ring: Viton® is
standard (other materials available). Washer Seal: Teflon®. Retainer, Ball and Spring: Stainless steel. Ball
Follower: Delrin.
Operating Temperature Range: -15°F to 200°F.
Fluid Conveying

Inline Easy Read® Flow Control Valves • For Hydraulic (To 55 GPM) & Pneumatic Service
Maximum
Operating
Pressure Flow
Catalog Body Non-Shock Rating CV A B C Price
Part No. Deltrol Model Size Threads Material (psi) (GPM) Factor (in) (in) (in) Wt. Each
•C1CN99 EF10B 1/8 1/8-27 NPT Brass 2000 3.0 0.28 1.28 0.63 1.94 0.25
•C1GG80 EF10S 1/8 1/8-27 NPT Steel 5000 3.0 0.28 1.28 0.63 1.94 0.24
•C1CP11 EF20B 1/4 1/4-18 NPT Brass 2000 6.0 0.53 1.41 0.75 2.41 0.42
Miscellaneous Products

C1CP12 EF20S 1/4 1/4-18 NPT Steel 5000 6.0 0.53 1.41 0.75 2.41 0.39
•C1CP13 EF25B 3/8 3/8-18 NPT Brass 2000 10.0 0.76 1.63 1.0 2.88 0.82
C1CP14 EF25S 3/8 3/8-18 NPT Steel 5000 10.0 0.76 1.63 1.0 2.88 0.76
C1KL39 EFM620S 3/8 SAE-6 Steel 5000 10.0 0.76 1.63 1.0 2.88 0.50
C1JS27 EFM825S 3/8 SAE-8 Steel 5000 10.0 0.76 1.63 1.0 2.88 1.05
•C1CP15 EF30B 1/2 1/2-14 NPT Brass 2000 12.0 0.93 1.97 1.63 3.44 1.22
C1CP16 EF30S 1/2 1/2-14 NPT Steel 5000 12.0 0.93 1.97 1.63 3.44 1.22
•C1CP17 EF35B 3/4 3/4-14 NPT Brass 2000 20.0 1.43 2.19 1.38 3.75 1.86
•C1CP18 EF35S 3/4 3/4-14 NPT Steel 5000 20.0 1.43 2.19 1.38 3.75 1.72
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
356
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Flow Control Valves

Hydraulic Power & Control


Inline Flow Control Valves
Vickers® FN Series • To 50 GPM

Inline Flow Control Valves • Vickers® FN Series • To 50 GPM


Catalog Vickers Part Price
Part No. No. Vickers Model Description Wt. Each

C1JX95 253361 FN-03-20 Non-Compensated Inline Adjustable Flow Control with Free Reverse Flow, 10 1.30
GPM Maximum Recommended Flow, 3/8" NPT Ports

Pneumatic Power & Control


Note: Please contact us for technical & application information on these valves.

Inline Pressure Compensated Flow Control Valves


Deltrol PC Series • To 30 GPM

Features: Maintains accurate constant flow at pressures up to 3,000 PSI (Non-shock service). Fixed (Factory set

Fluid Conveying
PC3 and PC4 models) and Adjustable (PC5 models). Free reverse flow (PC5 models).
Application: Flows are controlled within ±15% up to 1.5 GPM and at ±10% at higher flows up to 30 GPM.
Regulation is virtually unaffected by temperature changes from 60°F to 180°F (±2% at 70°F DT, ±4% at 120°F
DT). Series 3 and Series 4 models have a restricted reverse flow as limited by the internal orifice. Series 5
models have a free reverse flow.
Materials: Steel body (PC3 and PC5 models), Aluminum body (1/4 and 3/8 PC4 models), Steel body (1/2 and 3/4
PC4 models. Viton® O-Rings. Aluminum knob (PC5 models).
Operating Temperature Range: -15°F to 400°F.

Miscellaneous Products
Inline Pressure Compensated Flow Control Valves • Deltrol PC Series • To 30 GPM
Maximum
Operating Minimum
Pressure Differential
Catalog Deltrol Body Non-Shock Controlled Pressure Price
Part No. Model Series Size Threads Material (psi) Flow (PSI) Dimensions Wt. Each
0.20 GPM A=0.69
C1GK41 PC3-2-0.20 Series 3 1/4 1/4-18 NPT Steel 3000 Fixed 100 B=2.38 0.20

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
357
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Flow Control Valves
Hydraulic Power & Control

Inline Easy Read® Pressure Compensated Flow Control Valves


Deltrol EPC Series • To 34 GPM
Pneumatic Power & Control

Features: Pressure Compensated. Color coding and numerical readout allow positive, precise and repeatable
settings. Can be accurately adjusted within a small fraction of a turn (one full turn per color). Metal knob and
stem for durability.
Application: Controlled flow in one direction, free flow in opposite direction. Valves will start to control flow at 60
to 70 PSI pressure drop. Flow regulated between ± 10% above 1.5 GPM, ± 15% 0.5 to 1.5 GPM. Flow
adjustment can be made under pressure. Setting can be locked with set screw. Steel valves for use in hydraulic
systems.
Materials: Body: Steel. Needle: Stainless steel. O-Ring: Viton®. Washer: Teflon®. Knob: Aluminum. Piston:
Steel. Spring: Music wire.
Operating Temperature Range: -15°F to 200°F.
Fluid Conveying

Inline Easy Read® Pressure Compensated Flow Control Valves • Deltrol EPC Series • To 34 GPM
Maximum
Operating Minimum
Catalog Pressure Controlled Flow Differential A B C Price
Part No. Deltrol Model Size Threads (PSI) Range (GPM) Pressure (PSI) (in) (in) (in) Wt. Each
•C1CP31 EPC531 3/8 3/8-18 NPT 3000 1.0 to 10 70 1.97 1.50 5.42 2.47
•C1CP32 EPC541 1/2 1/2-14 NPT 3000 1.5 to 15 70 1.97 1.63 5.88 3.00
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
358
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Flow Control Valves

Hydraulic Power & Control


2-Port Non-Compensated Flow Control Valves
Vickers® FCV7-10 Series • To 12 GPM

Pneumatic Power & Control


Features: The FCV7-10 is a non-pressure compensated, adjustable, flow restrictor. Cartridge style (Requires a

Fluid Conveying
machined cavity or housing for installation).
Application: Controlled flow in one direction, free flow in opposite direction.
Maximum Flow Rate: 12 GPM.
Maximum Operating Pressure: 3000 PSI
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration Level: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model FCV7-10-* , sold separately.
Housing: Cavity size C-10-2, sold separately, see page 410

Miscellaneous Products
2-Port Non-Compensated Flow Control Valves • Vickers® FCV7-10 Series • To 12 GPM
Catalog Maximum Flow Adjustment Seal Price
Part No. Vickers Part No. Vickers Model Range (GPM) Type Housing Material Wt. Each
C1JT27 02-113005 FCV7-10-K-0-NV 0-12 Knob None Buna-N 0.30

Parts for Vickers® FCV7-10 Flow Control Valves


Catalog Price
Part No. Part Number Description Wt. Each
•C1KB65 565585 Knob 0.07
C1FK22 565806 SK2-10-2 Buna-N Seal Kit 0.01
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
359
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Flow Control Valves
Hydraulic Power & Control

2-Port Pressure-Compensated Flow Control Valves


Integrated Hydraulics 2CFRC60 Series • To 16 GPM
Pneumatic Power & Control

Features: This is a two-port, restrictive flow regulator with a built in free flow check valve. Typical uses include the
control of actuator speed by regulating the flow into or out of the actuator (meter-in or meter-out).
Operation: Flow into the inlet of the valve passes through the adjustable orifice and out of the regulated port. The
inbuilt check allows free return of flow (2 to 1).
Maximum Flow Rate: 16 GPM.
Maximum Operating Pressure: 5000 PSI.
Fluid Conveying

Temperature Range: –22° to +194°F


Recommended Filtration Level: Cleanliness Level 18/13 or better.
Cartridge: Model 2CFRC60-*, sold separately.
Housing: Cavity size A7447, sold separately, see page 410
2-Port Pressure-Compensated Flow Control Valves • Integrated Hydraulics 2CFRC60 Series • To 16 GPM
Catalog Maximum Flow Adjustment
Part No. Eaton Part No. Eaton Model Range (GPM) Type Housing Seal Material Wt. Price Each
Miscellaneous Products

C1MG49 405AA00054A 2CFRC60P6S 1.6 - 16 Screw None Nitrile 0.64


Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
360
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Flow Control Valves

Hydraulic Power & Control


2-Port Pressure-Compensated Flow Control Valves
Vickers® FAR1-16 Series • To 30 GPM

Pneumatic Power & Control


Features: This is a two-port, restrictive flow regulator with a built in free flow check valve. Typical uses include the
control of actuator speed by regulating the flow into or out of the actuator (meter-in or meter-out).
Operation: Flow into the inlet of the valve passes through the adjustable orifice and out of the regulated port. The
inbuilt check allows free return of flow (2 to 1).
Maximum Flow Rate: 30 GPM.
Maximum Operating Pressure: 5000 PSI

Fluid Conveying
Temperature Range: –40° to 248°F
Recommended Filtration Level: ISO 4406 Cleanliness Level 18/16/13.
Cartridge: Model FAR1-16-*, sold separately.
Housing: Cavity size C-16-2, sold separately, see page 410
2-Port Pressure-Compensated Flow Control Valves • Vickers® FAR1-16 Series • To 30 GPM
Catalog Maximum Flow Adjustment Seal Price
Part No. Vickers Part No. Vickers Model Range (GPM) Type Housing Material Wt. Each

Miscellaneous Products
C1MG19 02-183443 FAR1-16-S-0 1-30 Screw None Buna-N 1.48

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
361
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Flow Control Valves
Hydraulic Power & Control

Fixed Priority Flow Control with Relief on Priority Port


Vickers® Circuit Maker PFRR-10 • To 6 GPM Regulated
Pneumatic Power & Control

Features: Priority flow pressure compensation • All ports except “T” can be pressurized to 3000 psi • Aluminum
Fluid Conveying

in-line type housing • Tamper proof and adjustable relief options • Gauge port • All components in the package
are true cartridges and can be removed from the housing without disturbing the plumbing • Note: Some
assembly required.
Application: This standard valve package is used to maintain constant flow to priority circuits when input flow is
greater than required, regardless of changes in upstream or downstream pressure. It will bypass the rest of the
flow to an auxiliary circuit or to tank. Relief valve on a priority port limits pressure on a priority port, as well as
ensures bypass flow when there is no demand on priority circuit.
Maximum Inlet Flow: 15 GPM.
Miscellaneous Products

Regulated Flow Setting: 0.1 - 6.0 GPM (Fixed, non-adjustable)


Maximum Operating Pressure: 3000 PSI (All ports except port T).
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridges: Fixed Priority Flow Control Cartridge, PFR1-10-F-0-*, sold separately. Relief Cartridge, RV5-10-*-0-*,
sold separately.
Housing: 02-178276, sold separately.
Fixed Priority Flow Control with Relief on Priority Port • Vickers® Circuit Maker PFRR-10 • To 6 GPM
Regulated
Catalog Select (1) housing, (1) flow control cartridge and (1) relief Price
Part No. Vickers Part No. Vickers Model cartridge to make each valve assembly Wt. Each
Indexes & Technical Information

C1FJ12 02-178276 -- Housing, Aluminum, SAE-8 Ports (except SAE-4 Gauge Port) 1.53
C1FH97 02-165713 PFR1-10-F-0-4.00 Fixed Priority Flow Control Cartridge, Set at 4 GPM (Non-Adjustable) 0.26
C1FQ46 02-164209 RV5-10-S-0-35/15 Relief Cartridge, 250-3500 PSI Range (Set at 1500), Screw 0.53
Adjustment, Buna-N Seals
C1FM79 02-164222 RV5-10-S-0-20/12 Relief Cartridge, 100-2000 PSI Range (Set at 1200), Screw 0.51
Adjustment, Buna-N Seals
C1AD24 02-164723 RV5-10-S-0-35/14.5 Relief Cartridge, 250-3500 PSI Range (Set at 1450), Screw 0.52
Adjustment, Buna-N Seals
Note: Some assembly required. Select (1) housing, (1) flow control cartridge and (1) relief cartridge to make each valve assembly

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
362
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Flow Control Valves

Hydraulic Power & Control


3-Port Pressure Compensated Priority Flow Control
Vickers® PFR2-10 Series • To 10 GPM Regulated

Pneumatic Power & Control


Fluid Conveying
Features: Cartridge style (Requires a machined cavity or housing for installation). The flow adjustment range is
from the factory set maximum flow rate down to 50% of that rate. Pressure compensated for accurate flow
control regardless of changes in input or load pressure.
Application: This valve maintains a constant priority flow from port 1 to port 3 based on the setting adjustment,
regardless of pressure changes downstream on port 3. Flow in excess of the priority setting is directed to port 2.
If the priority flow at port 3 is blocked, the spool will shift to satisfy the priority flow requirement, thereby closing

Miscellaneous Products
off flow to port 2.
Maximum Flow Rate: 15 GPM (Inlet), 10 GPM (Priority).
Maximum Operating Pressure: 3000 PSI.
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration Level: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model PFR2-10*, sold separately.
Housing: Cavity size C-10-3, sold separately, see page 411
3-Port Pressure Compensated Priority Flow Control • Vickers® PFR2-10 Series • To 10 GPM Regulated
Catalog Adjustable Flow Adjustment Seal Price
Part No. Vickers Part No. Vickers Model Range (GPM) Type Housing Material Wt. Each

•C1FQ61 02-165669 PFR2-10-S-0/12.00 6.0 - 12.0 Screw with None Buna-N 0.50 Indexes & Technical Information
Locknut
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
363
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Flow Control Valves
Hydraulic Power & Control

3-Port Pressure Compensated Priority Flow Control


Vickers PFR2-16 Series • To 30 GPM
Pneumatic Power & Control

Feature: Cartridge style (Requires a machined cavity or housing for installation). The flow adjustment range is
from the factory set maximum flow rate down to 50% of that rate. Pressure compensated for accurate flow
control regardless of changes in input or load pressure.
Application: This valve maintains a constant priority flow from port 1 to port 3 based on the setting adjustment,
regardless of pressure changes downstream on port 3. Flow in excess of the priority setting is directed to port 2.
If the priority flow at port 3 is blocked, the spool will shift to satisfy the priority flow requirement, thereby closing
Fluid Conveying

off flow to port 2.


Maximum Flow Rate: 40 GPM (Inlet), 30 GPM (Priority)
Maximum Operating Pressure: 3000 PSI.
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration Level: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model PFR2-16*, sold separately.
Housing: Cavity size C-16-3, sold separately, see page 411
Miscellaneous Products

3-Port Pressure Compensated Priority Flow Control • Vickers PFR2-16 Series • To 30 GPM
Catalog Vickers Part Adjustable Flow Range Price
Part No. No. Vickers Model (GPM) Adjustment Type Seal Material Wt. Each
C1MF99 02-165648 PFR2-16-S-0-/15.00 7.5 - 15.0 Screw with Locknut Buna-N
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
364
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Flow Control Valves

Hydraulic Power & Control


Pressure & Temperature Compensated Flow Control Valves
Vickers® F(C)G-02/03 Series • To 28 GPM Regulated

Pneumatic Power & Control


Features: Both pressure and temperature compensated to minimize flow variation resulting from changes in fluid

Fluid Conveying
pressure and temperature. 4-1/2 turns of dial from full closed to full open. Subplate mounted. Key lock is
standard (2 keys are furnished with valve).
Application: Precise control of flow rate is obtained by rotating the dial. Maximum throttle openings may be
limited by addition of spacers to the throttle shaft under the selector dial.
Maximum Operating Pressure: Size -02 Models: 3600 PSI. Size -03 Models: 3000 PSI.
Maximum Flow Capacity: Size -02 Models: 10 GPM. Size -03 Models: 28 GPM.
Maximum Knob Torque Required: Size -03 Models: 20 lb. in. @ 3000 PSI (Proportional to outlet pressure).
Recommended Filtration Level: ISO 4406 Cleanliness Level 19/17/14 or cleaner.

Miscellaneous Products
Mounting Bolts: Size -02 Models: Standard mounting bolts are (4) 5/16-18 x 2 Grade 8 socket head capscrews
(Vickers Bolt Kit BKFG-02-640), torqued to 305 lb. in. Size -03 Models: Standard mounting bolts are (4) 3/8-16
x 3 Grade 8 socket head capscrews (Vickers Bolt Kit 255645, BKFG-03-645), torqued to 350 lb. in. See Bolt Kits
on page 409
Subplates: Size -02 Models: Vickers Model FGM-02-20 (3/8 NPT) or FGM-02X-20 (1/2 NPT) sold separately.
Size -03 Models: Vickers Part No. 681670 (Model FGM-03SZ-10) sold separately
Pressure & Temperature Compensated Flow Control Valves • Vickers® F(C)G-02/03 Series • To 28 GPM
Regulated
Reverse
Catalog Flow Flow Price
Part No. Vickers Part No. Vickers Model Range Check Seal Material Other Features Wt. Each Indexes & Technical Information
10 to
C1KA32 420607 FCG-02-1500-50 1500 Yes Buna-N 8.39
in³/min

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
365
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Flow Control Valves
Hydraulic Power & Control

3-Port Pressure Compensated Priority Flow Control Valves


Brand FC51 Series • To 90 GPM Regulated
Pneumatic Power & Control

Features: Precision ground chrome plated spool for long life. Diamond honed spool bore provides consistent
spool fit with low leakage. Every valve is factory tested for shutoff, linearity, max. flow & pressure compensation.
Application: The FC-51 full range pressure compensating variable flow control is designed so that the orifice area
varies as the lever is rotated. Fluid travels past the variable orifice, through the compensator spool and then out
Fluid Conveying

the controlled flow port. The flow out of the CF port is proportional to the orifice area which can vary from closed
to open. The sum of the controlled flow and the excess flow equal the inlet flow, and as the controlled flow
increases the excess flow decreases. Both outlets are pressure compensated by a spool that maintains a
constant flow while adjusting for pressure. Hunting between a compensated pump and the valve is dampened
with a dashpot on the compensator spool. The FC-51 can be used as a 2-port flow control by plugging the
excess flow port, and, for best results, limiting the flow to about 50% of the valve's rated flow.
Materials: Cast iron body. Heat treated spools (Stainless steel available). Buna-N O-Rings (Standard).
Maximum Operating Pressure: 3000 PSI.
Miscellaneous Products

Recommended Filtration: 30 micron.


3-Port Pressure Compensated Priority Flow Control Valves • Brand FC51 Series • To 90 GPM Regulated
Catalog Price
Part No. Brand Model Port Size Flow Range (GPM) Spool Material Wt. Each
•C1CQ87 FC-51-3/8 3/8 NPT 0-8 GPM Steel 8.03
•C1CQ83 FC-51-1/2 1/2 NPT 0-16 GPM Steel 7.75
C1KV87 FC-51-10SAE -10 SAE 0-16 GPM Steel 8.80
•C1CQ85 FC-51-3/4 3/4 NPT 0-30 GPM Steel 7.60
C1KV88 FC-51-12SAE -12 SAE 0-30 GPM Steel 8.20
C1CQ81 FC-51-1 1 NPT 0-50 GPM Steel 30.18
C1CQ82 FC-51-1-1/4 1-1/4 NPT 0-90 GPM Steel 30.18
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
366
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Flow Control Valves

Hydraulic Power & Control


3-Port Pressure Compensated Priority Flow Control Valves
(With Relief) Brand FCR51 Series • To 90 GPM Regulated

Pneumatic Power & Control


Features: Precision ground chrome plated spool for long life. Diamond honed spool bore provides consistent
spool fit with low leakage. Every valve is factory tested for shutoff, linearity, max. flow & pressure compensation.
High lift ball spring relief valve.
Application: The FCR-51 full range pressure compensating variable flow control is designed so that the orifice

Fluid Conveying
area varies as the lever is rotated. Fluid travels past the variable orifice, through the compensator spool and
then out the controlled flow port. The flow out of the CF port is proportional to the orifice area which can vary
from closed to open. Once the pressure on the CF port increases above the relief setting, the relief valve opens
and diverts flow to the EX port while maintaining pressure on the CF port. The EX port must be plumbed back to
tank for the relief to function. The sum of the controlled flow and the excess flow equal the inlet flow, and as the
controlled flow increases the excess flow decreases. Both outlets are pressure compensated by a spool that
maintains a constant flow while adjusting for pressure. Hunting between a compensated pump and the valve is
dampened with a dashpot on the compensator spool.

Miscellaneous Products
Materials: Cast iron body. Heat treated spools (Stainless steel available). Buna-N O-Rings (Standard).
Maximum Operating Pressure: 3000 PSI.
Recommended Filtration: 30 micron.
3-Port Pressure Compensated Priority Flow Control Valves • (With Relief) Brand FCR51 Series • To 90
GPM Regulated
Catalog Price
Part No. Brand Model Port Size Flow Range (GPM) Spool Material Wt. Each
•C1CT52 FCR-51-3/8 3/8 NPT 0-8 GPM Steel 7.89
•C1CT50 FCR-51-1/2 1/2 NPT 0-16 GPM Steel 7.89
•C1CT51 FCR-51-3/4 3/4 NPT 0-30 GPM Steel 7.58
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
367
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Logic Element Valves
Hydraulic Power & Control

Differential Pressure Sense Valve


Vickers® DPS2-20 Series • To 80 GPM
Pneumatic Power & Control

Features: The DPS2-20 is a differential pressure sensing valve, available as either a spool or poppet type and
with either, internal or external pilot.
Application: This valve is used as a main section of a pilot controlled valve assembly. This valve has multiple
uses when used with either directional control, flow control or pressure control cartridges.
Maximum Flow Rate: 80 GPM
Maximum Operation Pressure: 4200 PSI (spool type), 5000 PSI poppet type)
Fluid Conveying

Temperature Range: -40° F to 248° F


Recommended Filtration Level: Cleanliness code 18/16/13
Cartridge: Model DPS2-20-*, sold separately
Housing: Cavity size C-20-3S, sold seperately, see page 411
Differential Pressure Sense Valve • Vickers® DPS2-20 Series • To 80 GPM
Catalog Vickers Differential Pressure Price
Part No. Part No. Vickers Model Function Stroke Adjustment Setting Wt. Each
Miscellaneous Products

C1KF25 565608 DPS2-20-P-F-0-80 Spool, N/C (L/S element) None 80 PSI 1.66
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
368
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Flow Divider Valves

Hydraulic Power & Control


Proportional Flow Dividers
Brand B50 Series • To 30 GPM

Pneumatic Power & Control


Features: Precision ground heat treated spools for long life. Pressure compensation for both outlet ports. Every
valve is factory tested for flow ratio and pressure compensation.
Application: The B-50 is a non-adjustable divider that receives a single stream and divides into two streams. The
two outlet flows are pressure compensating and the sum of outlet flows equal the inlet flow. Flow is from inlet to
outlet only. The standard outlet flow ratio is 50:50. WARNING: Spool may bind if valve is mounted with bolts
through valve against a flat surface (housing can distort). Mount valve with rigid spacers between valve body
and mounting surface to prevent housing distortion.
Materials: Cast iron body. Buna-N O-Rings. Heat treated steel spool.
Maximum Operating Pressure: 3000 PSI.

Fluid Conveying
Recommended Filtration: 30 micron.
Proportional Flow Dividers • Brand B50 Series • To 30 GPM
Catalog Price
Part No. Brand Model Port Size Inlet Flow Range (GPM) Outlet Flow Ratio Wt. Each
•C1CK97 B-50-1/2 1/2 NPT 8-16 GPM 50:50 4.89
C1KV81 B-50-10SAE -10 SAE 8-16 GPM 50:50 2.20
•C1CK98 B-50-3/4 3/4 NPT 16-30 GPM 50:50 5.00

Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
369
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Flow Divider Valves
Hydraulic Power & Control

Proportional Flow Dividers (With Free Reverse Flow)


Brand B100 Series • To 30 GPM
Pneumatic Power & Control

Features: Precision ground heat treated spools for long life. Pressure compensation for both outlet ports. Free
reverse flow. Every valve is factory tested for flow ratio and pressure compensation.
Application: The B-100 is a non-adjustable divider that receives a single stream and divides into two streams.
The two outlet flows are pressure compensating and the sum of outlet flows equal the inlet flow. Flow can travel
in reverse through both outlet ports and is not metered when going in reverse. The standard outlet flow ratio is
50:50. WARNING: Spool may bind if valve is mounted with bolts through valve against a flat surface (housing
can distort). Mount valve with rigid spacers between valve body and mounting surface to prevent housing
distortion.
Materials: Cast iron body. Buna-N O-Rings. Heat treated steel spool.
Fluid Conveying

Maximum Operating Pressure: 3000 PSI.


Recommended Filtration: 30 micron.
Proportional Flow Dividers (With Free Reverse Flow) • Brand B100 Series • To 30 GPM
Catalog Price
Part No. Brand Model Port Size Inlet Flow Range (GPM) Outlet Flow Ratio Wt. Each
C1CK93 B-100-3/8 3/8 NPT 2-8 GPM 50:50 4.91
•C1CK92 B-100-3/4 3/4 NPT 16-30 GPM 50:50 4.64
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
370
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Flow Divider Valves

Hydraulic Power & Control


Proportional Flow Dividers (With Combining Feature)
Vickers® FDC1-10 Series • To 12 GPM

Pneumatic Power & Control


Fluid Conveying
Application: The Vickers FDC1-10 Divider/Combiner proportionally divides a single flow of hydraulic oil into two
equal or unequal flows, and combines in the reverse direction. The flow ratios remain constant despite load
differences between the ports. Accuracy is ± 10% when used within the recommended flow range. A special
feature of the FDC1 valve is that it provides rephase flow to either port when one is blocked. Example: If one
cylinder bottoms out first, the opposite cylinder is provided with rephase flow to allow it to bottom out also.
Flow Ratings: Nominal Inlet Flow 12 GPM (18 GPM Maximum).
Maximum Operating Pressure: 3000 PSI.
Accuracy: ± 10%.

Miscellaneous Products
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration Level: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model FDC1-10*, sold separately.
Housing: Cavity size C-10-4, sold separately, see page 413
Proportional Flow Dividers (With Combining Feature) • Vickers® FDC1-10 Series • To 12 GPM
Catalog Vickers Inlet Flow Range Outlet Flow Ratio Price
Part No. Part No. Vickers Model (GPM) (Port 4:Port2) Housing Seals Wt. Each
•C1EL11 566003 FDC1-10-0-11 0.74 - 2.9 50:50 None Buna-N 0.22
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
371
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Gate Valves
Hydraulic Power & Control

Brass Gate Valves


Brass M Gate Valve

Features: Screw-in bonnet.


Application: For water and steam service.
Maximum Operating Pressure: 125 WSP (steam), 200 PSI (WOG).
Pneumatic Power & Control

Brass Gate Valves • Brass M Gate Valve


Catalog
Part No. ACR Model Ports Wt. Price Each
C1KU82 3801 3/8 0.57
•C1KU83 3802 1/2 0.51
•C1KU84 3803 3/4 0.85
•C1KU85 3804-ACR 1 1.20
•C1KU86 3805 1-1/4 1.70
•C1KU87 3806-ACR 1-1/2 2.20
•C1KU88 3807-ACR 2 3.30
Fluid Conveying
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
372
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Needle Valves

Hydraulic Power & Control


Inline Needle Valves
For Hydraulic (To 34 GPM) & Pneumatic Service

Pneumatic Power & Control


Features: Wide adjustment range due to fine thread. Tamperproof adjustment key is standard. Knurled knob is
optional. Locknut is standard.
Application: Controlled flow in both directions. Flow adjustment can be made under pressure. Setting can be
locked with locknut. Brass valves for use in pneumatic systems and lower pressure hydraulic systems. Steel
valves for use in hydraulic systems. Pressure ratings in tables are for non-shock service.
Materials: Body: Available in Brass, carbon steel or stainless steel. Needle: Brass on brass valves, 416 stainless
steel on steel and stainless steel valves. O-Ring Packing: Viton®. Backup Washer: Teflon®. Optional Knob:
Aluminum. Tamper proof Key: Cadmium plated steel.
Operating Temperature Range: -15°F to 400°F.
Inline Needle Valves • For Hydraulic (To 34 GPM) & Pneumatic Service

Fluid Conveying
Maximum
Operating
Pressure Flow
Catalog Body Non-Shock Rating CV A B E Price
Part No. Deltrol Model Size Threads Material (psi) (GPM) Factor (in) (in) (in) Wt. Each
C1DF59 N20B 1/4 1/4-18 NPT Brass 2000 7.0 0.43 0.88 1.00 2.00 0.39
•C1DF61 N25B 3/8 3/8-18 NPT Brass 2000 13.5 0.78 1.06 1.81 2.25 0.59
Note: Models with K at end of model number have knurled adjustment knob instead of tamperproof adjustment key.

Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
373
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Needle Valves
Hydraulic Power & Control

Inline Easy Read® Needle Valves


For Hydraulic (To 100 GPM) & Pneumatic Service
Pneumatic Power & Control

Features: Color coding and numerical readout allow positive, precise and repeatable settings. Can be accurately
adjusted within a small fraction of a turn (one full turn per color). Metal knob and stem for durability.
Application: Controlled flow in both directions. Flow adjustment can be made under pressure. Setting can be
locked with set screw. Brass valves for use in pneumatic systems and lower pressure hydraulic systems. Steel
valves for use in hydraulic systems. Pressure ratings in tables are for non-shock service.
Materials: Body: Available in Brass, carbon steel or stainless steel (1" size available in naval bronze or ductile
iron). Needle: Brass on brass valves, stainless steel on steel and stainless steel valves. O-Ring: Viton® is
standard (other materials available). Washer Seal: Teflon®. Knob: Aluminum.
Operating Temperature Range: -15°F to 400°F.
Fluid Conveying

Inline Easy Read® Needle Valves • For Hydraulic (To 100 GPM) & Pneumatic Service
Maximum
Operating
Pressure Flow
Catalog Body Non-Shock Rating CV A B D Price
Part No. Deltrol Model Size Threads Material (psi) (GPM) Factor (in) (in) (in) Wt. Each
•C1CP21 EN10B 1/8 1/8-27 NPT Brass 2000 4.5 0.25 1.28 0.63 1.44 0.19
•C1CP22 EN10S 1/8 1/8-27 NPT Steel 5000 4.5 0.25 1.28 0.63 1.44 0.19
•C1CP23 EN20B 1/4 1/4-18 NPT Brass 2000 10.0 0.51 1.41 0.75 2.56 0.32
Miscellaneous Products

•C1CP24 EN20S 1/4 1/4-18 NPT Steel 5000 10.0 0.51 1.41 0.75 2.56 0.29
•C1CP25 EN25B 3/8 3/8-18 NPT Brass 2000 18.0 0.92 1.63 1.00 3.25 0.63
•C1CP26 EN25S 3/8 3/8-18 NPT Steel 5000 18.0 0.92 1.63 1.00 3.25 0.59
•C1CP27 EN30B 1/2 1/2-14 NPT Brass 2000 28.0 1.20 1.97 1.13 3.56 0.91
•C1CP28 EN30S 1/2 1/2-14 NPT Steel 5000 28.0 1.20 1.97 1.13 3.56 0.83
•C1CP29 EN35B 3/4 3/4-14 NPT Brass 2000 40.0 1.84 2.19 1.38 4.13 1.46
•C1CP30 EN35S 3/4 3/4-14 NPT Steel 5000 40.0 1.84 2.19 1.38 4.13 0.05
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
374
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Needle Valves

Hydraulic Power & Control


Inline Needle Valves
For Hydraulic & Pneumatic Service

Pneumatic Power & Control


Features: Bar stock construction for reliable performance. Hard seats. Bonnet is threaded for optional panel
mounting.
Application: Controlled flow in both directions.
Materials: Zinc plated AISI 1213 alloy steel body & bonnet. 316 stainless steel hardened stem. Black
polyethylene bonnet cap. Yellow cast aluminum handle (1/8 - 1/2 sizes). Yellow malleable iron handle (3/4-1
sizes). Grafiflex packing.
Maximum Operating Pressure: 10,000 PSI. (Minimum burst pressure is 20,000 PSI).
Operating Temperature Range: -100°F to 500°F.
Inline Needle Valves • For Hydraulic & Pneumatic Service
Catalog CV Price

Fluid Conveying
Part No. Marsh Model Size Threads Factor A (in) B (in) C (in) D (in) E (in) G (in) J (in) Wt. Each
•C1DF55 N1512 1/4 1/4 NPT 0.4 3.06 1.03 2.06 2.50 1.00 0.38 0.78 0.77
•C1DF56 N1513 3/8 3/8 NPT 0.9 3.75 1.44 2.88 2.50 1.38 0.75 0.91 1.59
•C1DF57 N1514 1/2 1/2 NPT 1.1 3.75 1.44 2.88 2.50 1.38 0.75 0.91 1.50

Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
375
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Needle Valves
Hydraulic Power & Control

Cartridge Type Needle Valves


Vickers® NV1-10 Series • To 12 GPM
Pneumatic Power & Control

Features: Cartridge style (Requires a machined cavity or housing for installation). Rotary knob.
Application: Controlled flow in both directions.
Rated Flow: 12 GPM.
Maximum Operating Pressure: 3000 PSI.
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration Level: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Fluid Conveying

Cartridge: Model NV1-10*, sold separately.


Housing: Cavity size C-10-2, sold separately, see page 410
Cartridge Type Needle Valves • Vickers® NV1-10 Series • To 12 GPM
Catalog Knob Seal Price
Part No. Vickers Part No. Vickers Model Color Housing Material Wt. Each
C1GH56 565590 NV1-10-K-0 Black None Buna-N 0.23
Miscellaneous Products

Parts for Vickers® NV1-10 Needle Valve Cartridges


Catalog Price
Part No. Part Number Description Wt. Each
C1FK22 565806 SK2-10-2 Buna-N Seal Kit 0.01
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
376
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Plug Valves

Hydraulic Power & Control


Brass 2-Way Shut-Off Plug Valves
Male Pipe to Female Pipe (Straight)

Pneumatic Power & Control


Features: Instantaneous on-off operation with 360° handle rotation. Lapped brass body and plug are individually
mated, providing an excellent quality, low friction valve.
Application: Used extensively for water process piping and air supply systems.
Maximum Operating Pressure: 30 PSI.
Operating Temperature Range: -40°F to 250°F.
Brass 2-Way Shut-Off Plug Valves • Male Pipe to Female Pipe (Straight)
Catalog Anderson Brass Price
Part No. Model Size Threads Wt. Each
•C1AK34 130C-L 1/4 1/4 NPT 0.20

Brass 3-Way Side Outlet Plug Valves

Fluid Conveying
Female Pipe

Miscellaneous Products
Features: Pointer lever to indicate port selection. Audible Click mechanism is standard. Valves are not lubricated
and require no lubrication. O-Ring sealed cap and stem. Brass body and CELCON® plug produce a fine seal
that will not seize or gall.
Application: Generally recommended for operation in gasoline, oil, air, water and detergent systems.
Maximum Operating Pressure: 30 PSI.
Operating Temperature Range: -40°F to 180°F.
Indexes & Technical Information
Brass 3-Way Side Outlet Plug Valves • Female Pipe
Catalog Anderson Brass Fluid Port Price
Part No. Model Size Threads Dia. (in) Handle Movement Features L (in) Wt. Each
•C1BB99 210C-N 3/8 3/8 NPT 0.312 Click is felt at each position. Handle rotates 360°. 1.375 0.50

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
377
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Plug Valves
Hydraulic Power & Control

Brass 4-Way Bottom Outlet Plug Valves


Female Pipe
Pneumatic Power & Control

Features: Pointer lever to indicate port selection. Audible Click mechanism is standard. Valves are not lubricated
and require no lubrication. O-Ring sealed cap and stem. Brass body and CELCON® plug produce a fine seal
that will not seize or gall.
Application: Generally recommended for operation in gasoline, oil, air, water and detergent systems.
Maximum Operating Pressure: 30 PSI.
Operating Temperature Range: -40°F to 180°F.
Brass 4-Way Bottom Outlet Plug Valves • Female Pipe
Catalog Anderson Brass Fluid Port Price
Part No. Model Size Threads Dia. (in) Handle Movement Features L (in) Wt. Each
Fluid Conveying

•C1EF53 200C-N 3/8 3/8 NPT 0.312 Click is felt at each position. Handle rotates 360°. 1.375 0.54
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
378
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Pressure Reducing Valves

Hydraulic Power & Control


Direct-Acting Pressure Reducing (Relieving) Valves
Vickers® PRV1-10 Series • To 4 GPM & 2400 PSI

Pneumatic Power & Control


Features: The PRV1-10 is a direct acting, spool type screw-in cartridge pressure reducing/relieving valve, and

Fluid Conveying
requires a machined cavity or housing for installation.
Application: Valve is normally open, allowing flow from port 2 to port 1. Port 3 is a drain and must be vented back
to reservoir. Once the pressure setting is reached at port 1, the spool shifts to restrict the inlet flow at port 2.
This regulates the pressure at port 1. If pressure at port 1 exceeds the predetermined setting of the valve, the
spool will shift further and relieve excess pressure through port 3.
Pressure Rating: 2400 PSI (All ports).
Rated Flow: 4 GPM.

Miscellaneous Products
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration Level: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model PRV1-10*, sold separately.
Housing: Cavity size C-10-3, sold separately, see page 411
Direct-Acting Pressure Reducing (Relieving) Valves • Vickers® PRV1-10 Series • To 4 GPM & 2400 PSI
Cracking
Pressure
Catalog Adjustment Range Factory Seal Price
Part No. Vickers Part No. Vickers Model Type (psi) Setting (psi) Housing Material Wt. Each

•C1BT43 565886 PRV1-10-S-0-24/ Screw and 400-2400 Mid-Range None Buna-N 0.56
locknut (apprx)
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
379
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Pressure Reducing Valves
Hydraulic Power & Control

Pilot-Operated Pressure Reducing (Relieving) Valves


Vickers® PRV2-10 Series • To 10 GPM & 3500 PSI
Pneumatic Power & Control

Features: The PRV2-10 is a pilot operated, spool type screw-in cartridge pressure reducing/relieving valve, and
Fluid Conveying

requires a machined cavity or housing for installation.


Application: This valve is normally open, allowing flow from port 2 to port 1. Port 3 is a drain and must be vented
back to reservoir. Once the pressure setting is reached at port 1, the spool shifts to restrict the inlet flow at port
2. This regulates the pressure at port 1. If pressure at port 1 exceeds the predetermined setting of the valve, the
spool will shift further and relieve excess pressure through port 3.
Pressure Rating: 3500 PSI All ports (CAUTION: Pressures over 3000 PSI require steel housing).
Rated Flow: 10 GPM.
Miscellaneous Products

Temperature Range: -40°F to 248°F (Extreme Limits).


Recommended Filtration Level: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model PRV2-10*, sold separately.
Housing: Cavity size C-10-3, sold separately, see page 411
Pilot-Operated Pressure Reducing (Relieving) Valves • Vickers® PRV2-10 Series • To 10 GPM & 3500 PSI
Cracking
Pressure
Catalog Adjustment Range Factory Seal Price
Part No. Vickers Part No. Vickers Model Type (psi) Setting (psi) Housing Material Wt. Each

•C1ZZ80 02-170743 PRV2-10-S-0-35/25 Screw and 250-3500 2500 None Buna-N 0.20
locknut
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
Indexes & Technical Information

maximum). Steel (Fatigue-rated Steel 5000 psi maximum).

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
380
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Pressure Reducing Valves

Hydraulic Power & Control


Pilot-Operated Pressure Reducing (Relieving) Valves
Vickers® PRV2-16 Series • To 40 GPM & 5000 PSI

Pneumatic Power & Control


Features: The PRV2-16 is a pilot operated, spool type screw-in cartridge pressure reducing/relieving valve, and
requires a machined cavity or housing for installation.
Application: This valve is normally open, allowing flow from port 2 to port 1. Port 3 is a drain and must be vented
back to reservoir. Once the pressure setting is reached at port 1, the spool shifts to restrict the inlet flow at port
2. This regulates the pressure at port 1. If pressure at port 1 exceeds the predetermined setting of the valve, the
spool will shift further and relieve excess pressure through port 3.

Fluid Conveying
Pressure Rating: 5000 PSI All ports (CAUTION: Pressures over 3000 PSI require steel housing).
Rated Flow: 40 GPM
Temperature Range: -40°F to 248°F
Recommended Filtration Level: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Cartridge: Model PRV2-16*, sold separately.
Housing: Cavity size C-16-3, sold separately, see page 411
Pilot-Operated Pressure Reducing (Relieving) Valves • Vickers® PRV2-16 Series • To 40 GPM & 5000 PSI

Miscellaneous Products
Cracking
Pressure
Catalog Adjustment Range Factory Seal Price
Part No. Vickers Part No. Vickers Model Type (psi) Setting (psi) Housing Material Wt. Each
C1MG59 566376 PRV2 16 S 0 60 Screw 1000-6000 3500 None Buna-N 0.89

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
381
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Relief Valves • Direct-Acting Ball Type
Hydraulic Power & Control

3-Port Direct-Acting Relief Valves


Brand RL Series • To 20 GPM
Pneumatic Power & Control

Features: In-line mounting. Precision built. Hardened, replaceable seat.


Adjustment Style: Adjustment screw underneath removable cap.
Maximum Operating Pressure: 3000 PSI.
Maximum Flow Rate: 20 GPM.
Fluid Conveying

3-Port Direct-Acting Relief Valves • Brand RL Series • To 20 GPM


Catalog Price
Part No. Brand Model Adjustment Range (psi) Pressure Port Tank Port Wt. Each
•C1GK51 RL-50 150-3000 1/2 NPT 1/2 NPT 2.67
•C1DK23 RL-75 150-3000 3/4 NPT 1/2 NPT 2.30
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
382
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Relief Valves • Direct-Acting Poppet Type

Hydraulic Power & Control


Panel Mount Direct-Acting Relief Valves
Vickers® C-175 • To 3 GPM

Pneumatic Power & Control


Fluid Conveying
Features: Panel mounting. Typically used to remotely control a “ventable” relief valve.
Adjustment Style: Knob with jam nut.
Maximum Operating Pressure: 3000 PSI.
Maximum Flow Rate: 3 GPM.
Panel Mount Direct-Acting Relief Valves • Vickers® C-175 • To 3 GPM
Catalog Vickers Adjustment Seal Price
Part No. Part No. Vickers Model Range (psi) Inlet Port Outlet Port Material Wt. Each

Miscellaneous Products
C1BW85 631056 C-175-F-20 1500-3000 1/4 NPT 1/4 NPT Viton® 3.30

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
383
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Relief Valves • Direct-Acting Poppet Type
Hydraulic Power & Control

Cartridge Type Direct-Acting Relief Valves


Vickers® RV1-10 Series • To 10 GPM
Pneumatic Power & Control

Features: Cartridge style (Requires a machined cavity or housing for installation). Continuous duty. Fast
response. Low cost.
Adjustment Style: See table.
Fluid Conveying

Maximum Operating Pressure: 3000 PSI.


Maximum Flow Rate: 10 GPM.
Cartridge: Model RV1-10-*, sold separately.
Housing: Cavity size C-10-2, sold separately, see page 410
Cartridge Type Direct-Acting Relief Valves • Vickers® RV1-10 Series • To 10 GPM
Catalog Vickers Vickers Model Price
Part No. Part No. (Cartridge Only) Adjustment Range (psi) Adjustment Type Seal Material Wt. Each
Miscellaneous Products

•C1BT33 565563 R1-10-S-0-30/ 500-3000 Screw Buna-N 0.53


Note: Housing not included.
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
384
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Relief Valves • Direct-Acting Differential Poppet Type

Hydraulic Power & Control


Cartridge Type Direct-Acting Relief Valves
Vickers® RV3-10 Series • To 20 GPM

Pneumatic Power & Control


Features: Cartridge style (Requires a machined cavity or housing for installation). Contamination tolerant. Fast
response.
Adjustment Style: See table.

Fluid Conveying
Maximum Operating Pressure: 3600 PSI (CAUTION: Pressures over 3000 PSI require steel housing).
Maximum Flow Rate: 20 GPM.
Cartridge: Model RV3-10-*, sold separately.
Housing: Cavity size C-10-2, sold separately, see page 410
Cartridge Type Direct-Acting Relief Valves • Vickers® RV3-10 Series • To 20 GPM
Catalog Vickers Adjustment Seal Price
Part No. Part No. Vickers Model Adjustment Range (psi) Type Housing Material Wt. Each

Miscellaneous Products
C1ET93 566688 RV3-10-S-0-3/ 50-300 Screw None Buna-N 0.51
•C1BT34 565568 RV3-10-S-0-36/ 600-3600 Screw None Buna-N 0.53
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
385
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Relief Valves • Direct-Acting Differential Poppet Type
Hydraulic Power & Control

Cartridge Type Direct-Acting Relief Valves


Vickers® RV3-16 Series • To 80 GPM
Pneumatic Power & Control

Features: Cartridge style (Requires a machined cavity or housing for installation). Contamination tolerant. Fast
response.
Adjustment Style: See table.
Maximum Operating Pressure: 5000 PSI (CAUTION: Pressures over 3000 PSI require steel housing).
Maximum Flow Rate: 80 GPM.
Cartridge: Model RV3-16-*, sold separately.
Housing: Cavity size C-16-2, sold separately, see page 410
Fluid Conveying

Cartridge Type Direct-Acting Relief Valves • Vickers® RV3-16 Series • To 80 GPM


Catalog Vickers Vickers Model Price
Part No. Part No. (Cartridge Only) Adjustment Range (psi) Adjustment Type Seal Material Wt. Each
•C1EN53 565569 RV3-16-S-0-35/ 1200-3500 Screw Buna-N 1.63
C1KA19 02-175554 RV3-16-S-0-50/47 2000-5000 (Set at 4700) Screw Buna-N 1.60
Note: Housing not included.
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
386
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Relief Valves • Pilot-Operated Poppet Type

Hydraulic Power & Control


Cartridge Type Pilot-Operated Poppet Type Relief Valves
Vickers® RV2-10 Series • To 30 GPM

Pneumatic Power & Control


Features: Cartridge style (Requires a machined cavity or housing for installation). Ideal for use as a service line
relief where anti-cavitation make-up is required.
Adjustment Style: See table.

Fluid Conveying
Maximum Operating Pressure: 5000 PSI (CAUTION: Pressures over 3000 PSI require steel housing).
Rated Flow Range: 3 to 30 GPM.
Cartridge: Model RV2-10-*, sold separately.
Housing: Cavity size C-10-2, sold separately, see page 410
Cartridge Type Pilot-Operated Poppet Type Relief Valves • Vickers® RV2-10 Series • To 30 GPM
Catalog Vickers Adjustment Seal Price
Part No. Part No. Vickers Model Adjustment Range (psi) Type Housing Material Wt. Each

Miscellaneous Products
•C1FA75 566212 RV2-10-S-0-35/ 250-3500 Screw None Buna-N 0.53
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
387
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Relief Valves • Pilot-Operated Spool Type
Hydraulic Power & Control

Cartridge Type Pilot-Operated Spool Type Relief Valves


Vickers® RV5-10 Series • To 30 GPM
Pneumatic Power & Control

Features: Cartridge style (Requires a machined cavity or housing for installation). Smooth and quiet. Continuous
duty.
Adjustment Style: See table.
Maximum Operating Pressure: 5000 PSI (CAUTION: Pressures over 3000 PSI require steel housing).
Maximum Flow Rate: 30 GPM.
Cartridge: Model RV5-10-*, sold separately.
Fluid Conveying

Housing: Cavity size C-10-2, sold separately, see page 410


Cartridge Type Pilot-Operated Spool Type Relief Valves • Vickers® RV5-10 Series • To 30 GPM
Catalog Vickers Adjustment Seal Price
Part No. Part No. Vickers Model Adjustment Range (psi) Type Housing Material Wt. Each
C1FM79 02-164222 RV5-10-S-0-20/12 100-2000 (Set at 1200) Screw None Buna-N 0.51
C1KK46 566246 RV5-10-S-0-35/ 250-3500 Screw None Buna-N 0.51
C1AD24 02-164723 RV5-10-S-0-35/14.5 250-3500 (Set at 1450) Screw None Buna-N 0.51
Miscellaneous Products

C1FQ46 02-164209 RV5-10-S-0-35/15 250-3500 (Set at 1500) Screw None Buna-N 0.53
•C1BT35 565572 RV5-10-S-0-50/ 500-5000 Screw None Buna-N 0.53
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
388
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Relief Valves • Pilot-Operated Spool Type

Hydraulic Power & Control


Cartridge Type Pilot-Operated Spool Type Relief Valves
Integrated Hydraulics 1VR200 Series • To 52 GPM

Pneumatic Power & Control


Features: This is a ventable, internally pilot operated relief valve designed to limit pressure in a system. Good for
continuous duty and accurate pressure control with constant or varying flows. The vent feature can be used with
remote pilot section for a two-pressure system or to allow manual or remote ‘unloading’ of the pump.
Maximum Operating Pressure: 5000 PSI (CAUTION: Pressures over 3000 PSI require steel housing).
Maximum Flow Rate: 52 GPM
Cartridge: Model 1VR200, sold separately
Housing: Cavity size A16102, sold separately, see page 411
Cartridge Type Pilot-Operated Spool Type Relief Valves • Integrated Hydraulics 1VR200 Series • To 52

Fluid Conveying
GPM
Catalog Integrated Integrated Adjustement Adjustment Seal Price
Part No. Hydraulics Part No. Hydraulics Model Range (psi) Type Housing Material Wt. Each
C1LX29 407AA00011A 1VR200P20S 145-3045 Screw None Nitrile 1.60

C1KK30 407AA00046A 1VR250P16T20S 145-3045 Screw SAE-16 ports Nitrile 3.20

Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
389
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Relief Valves • Pilot-Operated Spool Type
Hydraulic Power & Control

Cartridge Type Pilot-Operated Relief Valves


Vickers® RV5-16 Series • To 80 GPM
Pneumatic Power & Control

Features: Cartridge style (Requires a machined cavity or housing for installation). Smooth and quiet. Continuous
duty.
Adjustment Style: See table.
Maximum Operating Pressure: 6000 PSI (CAUTION: Pressures over 3000 PSI require steel housing).
Maximum Flow Rate: 80 GPM.
Cartridge: RV5-16-* sold separately.
Housing: Cavity C-16-2, sold separately, see page 410
Fluid Conveying

Cartridge Type Pilot-Operated Relief Valves • Vickers® RV5-16 Series • To 80 GPM


Catalog Vickers Adjustment Seal Price
Part No. Part No. Vickers Model Adjustment Range (psi) Type Housing Material Wt. Each
•C1EN56 565854 RV5-16-S-0-30/ 500-3000 Screw None Buna-N 0.79
Housing Types: Aluminum STD (Standard light-duty aluminum 3000 psi maximum). Aluminum FR (Fatigue-rated aluminum 3000 psi
maximum). Steel (Fatigue-rated Steel 5000 psi maximum).
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
390
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Relief Valves • Pilot-Operated Spool Type

Hydraulic Power & Control


3-Port Pilot-Operated Relief Valves
Vickers® CT & CS Series • To 60 GPM & 120 GPM

Pneumatic Power & Control


Features: In-line mounting. Gauge port. Ventable. Smooth and quiet. Continuous duty.
Adjustment Style: Adjustment knob with locking nut.
Maximum Operating Pressure: 3000 PSI.
Maximum Flow Rate: Standard Models: 60 gpm (3/4 & -12 size), 120 gpm (1-1/4 & -20 size). High Flow Models:
90 gpm (3/4 & -12 size), 180 gpm (1-1/4 & -20 size).

Fluid Conveying
3-Port Pilot-Operated Relief Valves • Vickers® CT & CS Series • To 60 GPM & 120 GPM
Adj.
Catalog Vickers Vickers Range Outlet Seal A B Price
Part No. Part No. Model (psi) Inlet Port Port Gauge Port Vent Port Matl. (in) (in) Wt. Each

C1BW11 590536 CT-06-B-50 125-1000 3/4 NPT 3/4 NPT 7/16-20 St.Thd. 9/16-18 St.Thd. Viton® 5.64 3.76 8.59
O-Ring O-Ring
•C1BW12 590538 CT-06-C-50 500-2000 3/4 NPT 3/4 NPT 7/16-20 St.Thd. 9/16-18 St.Thd. Viton® 5.64 3.76 8.57
O-Ring O-Ring

Miscellaneous Products
•C1BW13 590540 CT-06-F-50 1500-3000 3/4 NPT 3/4 NPT 7/16-20 St.Thd. 9/16-18 St.Thd. Viton® 5.64 3.76 8.66
O-Ring O-Ring
•C1BV99 590283 CT-10-F-30 1500-3000 1-1/4 NPT 1-1/4 NPT 7/16-20 St.Thd. 9/16-18 St.Thd. Viton® 6.18 4.88 14.58
O-Ring O-Ring

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
391
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Relief Valves • Pilot-Operated Spool Type
Hydraulic Power & Control

Subplate/Manifold Mount Pilot-Operated Relief Valves


Vickers® CG2V-6/8 & CG5V-6/8 Series • To 106 GPM
Pneumatic Power & Control
Fluid Conveying

Features: Close matching to application requirements from choice of four adjustment control ranges covering 44
to 5000 psi • Electrical on/off load from solenoid controlled models • Remote parallel control by other pilot valves
connected to “vent” port • High machine productivity resulting from full system flow being available for work
output until system pressure is very close to valve setting • Pressure override optimized without detriment to
other performance parameters • Excellent repeatability and stable performance from cartridge-type design of
mainstage parts • Low off-load power wastage • International mounting interfaces • Low installed cost and space
requirement from high power/size ratios (more than double that of many conventional designs).
Maximum Operating Pressure: 5000 PSI ports P & X. Port T 1500 PSI for CG5V models, 5000 PSI for CG2V
Miscellaneous Products

models.
Maximum Flow Rate: 53 GPM (Size 6 models), 106 GPM (Size 8 models).
Temperature Range: -4°F to 158°F (petroleum oil).
Recommended Filtration Level: ISO 4406 Cleanliness Level 19/17/14 or cleaner.
Solenoid Connectors: page 415 (Required on models that use DIN 43650 connectors).
Subplate/Manifold Mount Pilot-Operated Relief Valves • Vickers® CG2V-6/8 & CG5V-6/8 Series • To 106
GPM
Catalog Vickers Part Mounting Price
Part No. No. Vickers Model (ISO 6264) Function Features Wt. Each

C1JM56 615027 CG2V-8BW-10 Size 8 Relief 44-1000 PSI Adjustment Range, Screw 9.70
Indexes & Technical Information

(AR-08-2-A) Adjustment with Locknut

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
392
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Relief Valves • Guided Piston Type

Hydraulic Power & Control


Guided Piston Relief Valves
Fulflo V Series with Threaded Ports

Pneumatic Power & Control


Application: The sliding piston concept and internal design contours of FULFLO valves provide unique flow and
stability characteristics for reliable performance without chatter. Unlike ordinary direct acting relief valves,
FULFLO guided piston valves are less responsive to transient pressure surges thereby eliminating the tendency
to pound, squeal or chatter. Quiet, stable, efficient performance is assured in both load regulation and system
protection applications. FULFLO valves operate effectively with all types of liquids in the full range of viscosities
including hydraulic oils, water, solvents and chemicals. Since the FULFLO relief valve is a flow-modulating

Fluid Conveying
device, pressure flow characteristics are completely different from spring loaded poppet or ball check valves.
Both types remain substantially tight up to cracking pressure. When this pressure is exceeded, the
“conventional” valve pops open with a pressure drop at very low flow and an exponential pressure rise as the
flow increases. In contrast the FULFLO valve causes a pressure rise, over-pressure, as soon as flow starts;
pressure increases almost proportionally with flow. Springs and areas on FULFLO valves are carefully designed
to minimize this over-pressure.
Note: FULFLO valves are not designed to be positive shut off, and will pass a minimal amount of leakage before
the set pressure. FULFLO valves are NOT designed for use with air, gas or steam.

Miscellaneous Products
Performance Charts: page 646
Guided Piston Relief Valves • Fulflo V Series with Threaded Ports
Rated
Catalog Capacity Other AA BB CC DD Price
Part No. Fulflo Model Ports (GPM) Body Spring Piston O-Ring Features (in) (in) (in) (in) Wt. Each
507-YS
C1FG22 VJ-5-YS-190PSI 1 NPT 25 Cast (150-350 Hardened Buna-N 8.22 2.28 2.28 2.06 5.37
Iron Steel
PSI)

Cast 707-XS Hardened


C1EZ82 VJ-7-XS 1-1/2 NPT 80 Iron (60-175 Steel Buna-N 11.06 2.69 2.69 2.88 13.49
PSI)
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
393
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Sandwich Valves • NFPA Size D03 • ISO 4401 Size 03
Hydraulic Power & Control

Vickers Sandwich Valves

Vickers® Sandwich Valves • NFPA-D03 Size


Aluminum Valve Bodies • Pressures to 3000 PSI
Features: • Reduces System Space Requirements • Reduce Cost • Versatile and Easy
to Install • Linking and blanking plates are available to facilitate a variety of circuit
designs and flexibility in applying these valves • Rugged and Reliable • Cartridges are
accessible without removing valves from an assembled stack. • Housings are
assembled in a kit containing a locating pin, all necessary plugs and standard Viton
seals.
Pneumatic Power & Control

Construction: Aluminum (Housings, Blanking Plates, Linking Plates and Spacer


Plates).
Valve Cartridges: Screw-in valve cartridges.
Maximum Operating Pressure: 3000 PSI.
Temperature Range & Recommended Filtration: Refer to information on cartridge valve(s) selected.
Seal Material: Viton® o-rings are standard and are included along with locating pin to mount housings and plates
to the NFPA-D03 surface (4ea -012 size o-rings).
Bolt Kits: 10-24 grade 8 socket head cap screws lubricated and torqued to 63-80 lb.in. Bolt kits on page 409
Stud Rod & Nut Kits: Kit number 02-184932: 4ea 10-24 x 7 inch stud rods and stud nuts. Kit number 02-184933:
4ea 10-24 x 12 inch stud rods and stud nuts. Stud rods/nuts should be torqued to 40-53 lb.in. with threads
lubricated.
Fluid Conveying

A323W Housing Kit


Miscellaneous Products

Typical Cartridges: Counterbalance valves on A & B cross piloted, CBV-1-10 Series page 254 . Pilot operated
check valves on A & B cross piloted, POC1-10 Series
A323W Housing Kit
Housing
Indexes & Technical Information

Catalog Vickers Height Price


Part No. Vickers Part No. Model Cavity Qty & Size Typical Cartridges (in) Wt. Each
CBV*-10 (Counterbalance valves on A & B
C1HY33 02-185347 A323W 2ea C-10-3S cross-piloted), POC1-10 (Pilot-operated check 1.70 1.21
valves on A & B cross-piloted)

Cartridges for A323W Sandwich Valve Housing Kit


Catalog Price
Part No. Part Number Description Wt. Each
Counterbalance Cartridge, CBV1-10-C-0-A-30, 900-3000 PSI Adjustment Range, Cap
•C1AD25 02-171990 over Adjusting Screw, Buna-N Seals, 4:1 Control Ratio 0.53
CBV1-10 Cartridge Specifications: page 254

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
394
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Selector Valves • Single, Double, 2-Wheel / 4-Wheel, Solenoid Operated

Hydraulic Power & Control


Single Selector Valves
Cross VS Series

Pneumatic Power & Control


Cross VS Series hydraulic selector valves are manually operated, spool type, 3-way 2-position valves featuring
cast-in metering notches for smooth operation. They provide an economical method of diverting flow to either of
two hydraulic circuits and are available with a variety of actuators.
Construction: High tensile strength cast iron body. Ground, plated and polished steel spool. Buna-N seals.
Available Options: Actuator location port A or port B side. Knob, clevis or plain actuator (VS2 models). Knob,
clevis, plain, handle or hydraulic pilot actuator (VS4 models). Manual spool action (VS2 models). Manual,
spring return, 2-position detent or hydraulic pilot spool action (VS4 models). Front, bottom or both front and
bottom inlet port location. 1/2 NPT or SAE-8 ports (VS2 models). 3/4 NPT, SAE-12 or SAE-16 ports (VS4

Fluid Conveying
models).
Single Selector Valves • Cross VS Series
Nominal
Flow Maximum
Catalog Rating Operating Price
Part No. Cross Model Port Size (GPM) Pressure (psi) Features Dimensions (in) Wt. Each
Standard Knob actuator
port B side. Standard A=2.12 B=1.53 C=0.34
D=3.25 E=1.19 F=1.62
•C1GK85 VS2BKLF2 1/2 NPT 20 2500 Manual spool positioning. 3.24

Miscellaneous Products
G=2.25 H=1.00 J=0.31
Standard front inlet port K=5.33
location.
Standard Knob actuator
port B side. Standard A=3.00 B=1.56 C=0.34
•C1GK86 VS4BKLF6 3/4 NPT 40 2500 Manual spool positioning. D=4.12 E=1.50 F=2.12 7.19
Standard front inlet port G=2.62 H=1.12 J=6.12
K=6.12
location.
Standard Knob actuator A=3.00 B=1.56 C=0.34
port B side. Standard D=4.12 E=1.50 F=2.12
•C1GK87 VS4BKLF9 SAE-16 40 2500 Manual spool positioning. 6.67
Standard front inlet port G=2.62 H=1.12 J=6.12
location. K=6.12

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
395
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Selector Valves • Single, Double, 2-Wheel / 4-Wheel, Solenoid Operated
Hydraulic Power & Control

Double Selector Valves


Cross SD Series
Pneumatic Power & Control
Fluid Conveying

Cross SD Series hydraulic selector valves are manually operated, spool type, 6-way 2-position valves featuring
cast-in metering notches for smooth operation. They provide an economical method of diverting flow to two
separate hydraulic circuits or providing various types of multiple system operations in combination with other
valves.
Construction: High tensile strength cast iron body. Ground, plated and polished steel spool. Buna-N seals.
Available Options: Actuator location port C or port D side. Knob, clevis, handle, plain or hydraulic pilot actuator.
Manual, spring return, 2-position detent or hydraulic pilot spool action. Selector or Series/Parallel spool type.
SAE-8, SAE-12, SAE-16, 3/4 NPT or 1 NPT ports.
Miscellaneous Products

Double Selector Valves • Cross SD Series


Nominal
Flow Maximum
Catalog Rating Operating Price
Part No. Cross Model Port Size (GPM) Pressure (psi) Features Wt. Each

•C1GK53 SD4BALA4 3/4 NPT 40 2500 Selector Spool. Optional Handle actuator port D side. 9.70
Standard Manual spool positioning.
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
396
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Selector Valves • Single, Double, 2-Wheel / 4-Wheel, Solenoid Operated

Hydraulic Power & Control


2-Wheel / 4-Wheel Selector Valve
Cross SD5 Series

Pneumatic Power & Control


Fluid Conveying
Miscellaneous Products
The Cross SD5 2-wheel / 4-wheel selector valve has been specifically designed for use with hydrostatic
transmissions and permits selection of either 2-wheel (transport mode) or 4-wheel (work mode) drive positions.
Specifications: Maximum working pressure: 5000 PSI. Maximum shock & surge pressure: 6000 PSI. Maximum
flow capacity: 50 GPM.
Construction: High tensile strength cast iron body. Ground, plated & polished steel spool. Buna-N seals.
Indexes & Technical Information
Available Options: Ports - 1/2 NPT, SAE-8, SAE-12, SAE-16. Actuator - Handle, Knob, Clevis, Pilot, 12VDC
Solenoid.
Application Note: When in 2-wheel drive, supercharge oil is supplied to the non-driving motors, preventing
cavitation. When operating in 2-wheel drive for long periods of time, it may be necessary to occasionally shift
into 4-wheel drive in order to cool the non-driving wheel motors.
2-Wheel / 4-Wheel Selector Valve • Cross SD5 Series
Catalog Actuator Price
Part No. Cross Model Location Actuator Option End Cap Option Spool Type Port Size Wt. Each

C1EP17 SD5BUBA7 Port D Hydraulic Pilot Spring Return 2-Wheel / 4-Wheel SAE-16 10.00
Side Selector

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
397
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Selector Valves • Single, Double, 2-Wheel / 4-Wheel, Solenoid Operated
Hydraulic Power & Control

Solenoid-Operated Selector Valves


Walvoil DFE Series
Pneumatic Power & Control
Fluid Conveying

Available Ways: DFE052: 2-3-6-8-way. DFE20: 3-6-way.


Nominal Flow Rating: DFE052: 16 GPM. DFE20: 37 GPM.
Maximum Operating Pressure: 2900 PSI (without drain), 4600 PSI (with optional drain).
Internal Leakage: DFE052: 0.43 in³/min maximum at 1450 PSI differential pressure. DFE020: 0.92 in³/min
Miscellaneous Products

maximum at 1450 PSI differential pressure.


Fluid Temperature Range: -4°F to 176°F (standard Buna-N seals), -4°F to 212°F (optional Viton® seals).
Ambient Temperature Range: -40°F to 140°F.
Viscosity: 80 to 400 SSU Operating, 70 SSU Minimum, 1950 SSU Maximum.
Maximum Level of Contamination: ISO 4406 19/16.
Note: Performance data measured with mineral oil of 215 SSU viscosity at 104°F.
Solenoid-Operated Selector Valves • Walvoil DFE Series
Nominal
Catalog Flow Spool Other Price
Part No. Walvoil Model Ports Rating Spool Type Positioner Coil Features Wt. Each
6-way, 2-pos, Spring return
C1KL99 FVL12A270034 6 16 GPM 12VDC 4.40
Indexes & Technical Information

closed crossover to position 1

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
398
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Slip-In Cartridge Valves

Hydraulic Power & Control


Slip-In Cartridge Valves
To ISO 7368 (DIN 24342)
Detailed information on the entire line of Vickers® Slip-In Cartridge Valves can
be found in Literature ID # 5043.00/EN/0499/A. Please contact us for
application assistance or to request a copy of this publication.

Pneumatic Power & Control


Fluid Conveying
Slip-In Cartridge Valves • To ISO 7368 (DIN 24342)

Miscellaneous Products
Catalog Vickers Part Price
Part No. No. Vickers Model Key Description Wt. Each
Relief Insert, 1:1 Area Ratio, Size 25, 45 PSI Cracking
C1GN27 02-156365 CVI-25-D10-2-H-40 D10 Pressure 0.73

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
399
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Stack Valves • NFPA Size D03 • ISO 4401 Size 03
Hydraulic Power & Control

Vickers SystemStak™ Valves

Vickers® SystemStak™ Valves • NFPA-D03 Size


Flows to 16 GPM • Pressures to 4500 PSI
Features: Save space & installation time. Reduce potential leaks. Standard
interface. Rugged design with large flow passages, high pressure and high
flow ratings.
Construction: Ductile iron (spheroidal graphite) body (NFPA fatigue proof
rated at 4500 PSI). Hardened steel internal parts. Aluminum nameplates.
Standard Viton® seals.
Pneumatic Power & Control

Available Functions: Relief, Counterbalance, Sequence, Pressure Reducing,


Direct Check, Pilot-Operated Check, Flow Control.
Maximum Operating Pressure: 4500 PSI.
Ambient Temperature Limits: -4°F to 176°F.
Fluid Temperature Limits: Petroleum Oil: -4°F to 176°F. Water Base Fluids:
50°F to 129°F.
Filtration Requirements: Up to 3000 PSI: ISO level 20/16. Over 3000 PSI:
ISO level 18/14.
Bolt Kits: 10-24 grade 8 socket head cap screws lubricated and torqued to
63-80 lb.in. Bolt kits on page 409
Dimensions & Technical Information: page 647
Size D03 Subplates & Manifolds: page 418
Fluid Conveying

Vickers® SystemStak™ Relief Valves


NFPA-D03 • ISO 4401-03
General Description: These pilot-operated adjustable pressure relief valves limit the
maximum pressure in the line(s) controlled by the integral relief valve elements.
Pressure adjustment of screw & locknut or control knob (with or without keylock) are
available.
Miscellaneous Products

Stacking Height to add for Bolt Length: 1.57 inches.


Indexes & Technical Information

Vickers® SystemStak™ Relief Valves • NFPA-D03 • ISO 4401-03


Pressure
Catalog Vickers Adjustment Adjustment Gauge Price
Part No. Part No. Vickers Model Key Type Function Range (psi) Type Port Wt. Each

C1JA16 694419 DGMC-3-PT-CW-41 A Single P to T 145-2900 Screw & No 2.90


Relief Locknut

C1DZ90 871702 DGMC2-3-AT-GW-BT-GW-41 C Dual Relief A to T, B to T 75-4500 Screw & No 3.00


Locknut

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
400
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Stack Valves • NFPA Size D03 • ISO 4401 Size 03

Hydraulic Power & Control


Vickers SystemStak™ Valves

Vickers SystemStak™ Pressure Reducing Valves


NFPA-D03 • ISO 4401-03
General Description: The flow path is normally open and is closed as the pilot
pressure exceeds the setting of the valve. Excessive pressure in the reduced pressure
line is prevented by a pressure relieving function. Pressure adjustment options of
screw & locknut or control knob (with or without keylock) are available.
Stacking Height to add for Bolt Length: 1.57 inches.

Pneumatic Power & Control


Vickers SystemStak™ Pressure Reducing Valves • NFPA-D03 • ISO 4401-03
Pressure
Catalog Vickers Adjustment Adjustment Adjuster Gauge Price
Part No. Part No. Vickers Model Key Function Range (psi) Type Location Port Wt. Each
Pressure Reduced in P Screw & B Port
C1DZ89 870039 DGMX2-3-PP-BW-S-40 A Piloted from P 51-1000 Locknut End SAE-4 2.90
Pressure Reduced in P Screw & B Port

Fluid Conveying
C1CA50 870040 DGMX2-3-PP-CW-S-40 A Piloted from P 145-2000 Locknut End SAE-4 2.90

Vickers SystemStak™ Check Valves


NFPA-D03 • ISO 4401-03
General Description: These valves allow free flow in one direction in the line in which the check

Miscellaneous Products
valve element(s) is (are) located. Flow in the opposite direction is not possible.
Stacking Height to add for Bolt Length: 1.57 inches.

Indexes & Technical Information


Vickers SystemStak™ Check Valves • NFPA-D03 • ISO 4401-03
Cracking
Catalog Vickers Pressure Price
Part No. Part No. Vickers Model Key Function (psi) Wt. Each
C1JL49 02-138605 DGMDC-3-Y-PM-41 A Check in P, Free Flow towards Work Port 36.0 2.08

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
401
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Stack Valves • NFPA Size D03 • ISO 4401 Size 03
Hydraulic Power & Control

Vickers SystemStak™ Valves

Vickers SystemStak™ Pilot-Operated Check Valves


NFPA-D03 • ISO 4401-03
General Description: These valves provide pilot-operated check functions in one or both work
ports, with pilot pressure coming from the opposite side. An optional 10:1 decompression
feature is available.
Stacking Height to add for Bolt Length: 1.57 inches.
Pneumatic Power & Control

Vickers SystemStak™ Pilot-Operated Check Valves • NFPA-D03 • ISO 4401-03


Cracking
Catalog Vickers Pilot Pressure Price
Part No. Part No. Vickers Model Key Function Ratio (psi) Wt. Each
•C1BY42 694400 DGMPC-3-ABK-BAK-41 A Dual Pilot Check 3:1 14.5 2.28
•C1FF82 870024 DGMPC-3-ABK-41 B Single Pilot Check in A Piloted from B 3:1 14.5 2.13
Fluid Conveying

Vickers SystemStak™ Flow Control Valves


NFPA-D03 • ISO 4401-03
General Description: These valves regulate flow by means of an adjustable orifice
which is not pressure compensated, and flow through the valve is entirely dependent
upon pressure drop at any particular setting of the orifice. Single and Dual work port
Miscellaneous Products

models with integral reverse flow checks are available in both meter-our and meter-in
styles. Single P port models are available without the reverse flow check.
Stacking Height to add for Bolt Length: 1.57 inches.
Indexes & Technical Information

Vickers SystemStak™ Flow Control Valves • NFPA-D03 • ISO 4401-03


Control
Catalog Vickers Needle Adjustment Price
Part No. Part No. Vickers Model Key Function Type Type Wt. Each

•C1BY43 694412 DGMFN-3-Y-A2W-B2W-41 A Dual Meter Out of Work Ports Standard Screw & 2.41
Locknut
C1BY44 694414 DGMFN-3-X-A2W-B2W-41 B Dual Meter In to Work Ports Standard Screw & 2.40
Locknut

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
402
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Stack Valves • NFPA Size D03 • ISO 4401 Size 03

Hydraulic Power & Control


Vickers SystemStak™ Valves

Pneumatic Power & Control


Fluid Conveying
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
403
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Stack Valves • NFPA Size D05 • ISO 4401 Size 05
Hydraulic Power & Control

Vickers SystemStak™ Valves

Vickers® SystemStak™ Valves • NFPA-D05 Size


Flows to 32 GPM • Pressures to 4500 PSI
Features: Save space & installation time. Reduce potential leaks. Standard interface.
Rugged design with large flow passages, high pressure and high flow ratings.
Construction: Ductile iron (spheroidal graphite) body (NFPA fatigue proof rated at
4500 PSI). Hardened steel internal parts. Aluminum nameplates. Standard Viton®
seals.
Available Functions: Relief, Counterbalance, Sequence, Pressure Reducing, Direct
Pneumatic Power & Control

Check, Pilot-Operated Check, Flow Control.


Maximum Operating Pressure: 4500 PSI.
Fluid Temperature Limits: Dependent on type of valve (See limits in individual group
information).
Filtration Requirements: ISO level 19/17/14.
Mounting Bolt Options: Size 05 SystemStak™ valves may be mounted with either bolt extender kits or standard
1/4-20 grade 8 socket head cap screws. (Threads lubricated Bolt Extender torque is 100-130 lb. in. Threads
lubricated standard socket head cap screw torque is 112 lb.in. maximum).
Bolt Extenders: page 409
Bolt Kits: page 409
Dimensions & Technical Information: page 652
Size D05 Subplates & Manifolds: page 420
Fluid Conveying

Vickers® SystemStak™ Relief Valves


NFPA-D05 • ISO 4401-05
General Description: These two-stage valves limit
system pressure by directing flow to tank or the
opposite work port when system pressure reaches the
valve setting. Pressure control may be obtained in A,
Miscellaneous Products

B, A & B, or P port, and pilot flow may be internally or


externally drained, depending on model type. Any
back pressure is additive to valve setting. Standard adjustment is a screw with
locknut (other options available). External remote control/vent options are
available.
Fluid Temperature Limits: 32°F to 180°F.
Stacking Height: 1.97 inches (Single & Dual Reliefs), 2.36 inches (Crossover
Reliefs).
Indexes & Technical Information

Vickers® SystemStak™ Relief Valves • NFPA-D05 • ISO 4401-05


Pressure
Catalog Vickers Adjustment Adjustment Gauge Price
Part No. Part No. Vickers Model Key Type Function Range (psi) Type Port Wt. Each
Pressure
C1HJ81 867315 DGMC-5-PT-GW-S-30 A Single Limited in P 60-4500 Screw & SAE-4 7.17
Relief Locknut
Port

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
404
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Stack Valves • NFPA Size D05 • ISO 4401 Size 05

Hydraulic Power & Control


Vickers SystemStak™ Valves

Vickers SystemStak™ Pilot-Operated Check Valves


NFPA-D05 • ISO 4401-05
General Description: These valves provide
pilot-operated check functions in one or both work
ports, with pilot pressure coming from the opposite
side. An optional 20:1 decompression feature is
available.
Fluid Temperature Limits: 32°F to 180°F.

Pneumatic Power & Control


Stacking Height: 1.97 inches.

Vickers SystemStak™ Pilot-Operated Check Valves • NFPA-D05 • ISO 4401-05


Cracking
Catalog Vickers Pilot Pressure Price
Part No. Part No. Vickers Model Key Function Ratio (psi) Wt. Each

Fluid Conveying
C1JE98 867364 DGMPC-5-ABK-BAK-30 A Dual Pilot-Operated Check Standard 15 6.47

Vickers SystemStak™ Flow Control Valves


NFPA-D05 • ISO 4401-05
General Description: These valves regulate flow by

Miscellaneous Products
means of an adjustable orifice which is not pressure
compensated, and flow through the valve is entirely
dependent upon pressure drop at any particular setting
of the orifice. Single and Dual work port models with
integral reverse flow checks are available in both meter-our and meter-in styles.
Single P and T port models are available without the reverse flow check.
Fluid Temperature Limits: 32°F to 180°F.
Stacking Height: 1.97 inches.
Vickers SystemStak™ Flow Control Valves • NFPA-D05 • ISO 4401-05
Control Indexes & Technical Information
Catalog Vickers Needle Adjustment Price
Part No. Part No. Vickers Model Key Function Type Type Wt. Each
Screw &
C1CA45 867332 DGMFN-5-Y-A2W-B2W-30 A Dual Meter Out of Work Ports Standard Locknut 6.86

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
405
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
System Accessory Valves
Hydraulic Power & Control

Air Bleed Valves, Shuttle Valves, Velocity Fuses

Shuttle Valves
Brand SHV Series
Pneumatic Power & Control

Features: Cast iron body. Buna-N O-rings. Hardened steel ball for wear resistance, greater durability and
minimal leakage.
Application: Has two inlets and one outlet. Accepts flow from the inlet with higher pressure and routes it to the
outlet, while keeping the inlet flows isolated from one another. 30 micron filtration recommended.
Shuttle Valves • Brand SHV Series
Maximum Flow
Catalog Operating Rating Price
Part No. Brand Model Port Size Body Material Pressure (PSI) (GPM) Peak Pressure Drop (PSI) Wt. Each
•C1GK55 SHV25 1/4 NPT Cast Iron 3,000 5.0 50 0.50
Fluid Conveying
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
406
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
System Accessory Valves

Hydraulic Power & Control


Air Bleed Valves, Shuttle Valves, Velocity Fuses

Shuttle Valves
Vickers® DSV2-8 Series

Pneumatic Power & Control


Description: The DSV2-8-B is a direct acting, ball type, shuttle valve.

Fluid Conveying
Operation: The shuttle valve senses the higher of two pressures at port 3 or port 1 and directs it to port 2.
Rated Flow: 6 GPM.
Maximum Operating Pressure: 3500 PSI typical application pressure, 3500 PSI cartridge fatigue pressure
(infinite life). CAUTION: Pressures over 3000 PSI require steel housing.
Temperature Range: -40°F to 248°F (Extreme Limits).
Recommended Filtration Level: ISO 4406 Cleanliness Level 18/16/13 or cleaner.
Internal Leakage: 5 drops/min. maximum @ 3500 PSI (Between ports 2 and 1, and 2 and 3. Typical with fluid at

Miscellaneous Products
105 SSU and 120°F).
Cartridge: Model DSV2-8-*, sold separately.
Housing: Cavity size C-8-3, sold separately, see page 411
Shuttle Valves • Vickers® DSV2-8 Series
Catalog Price
Part No. Vickers Model Housing Seals Wt. Each
•C1FQ51 02-171239 DSV2-8-B-0 None Buna-N 0.15

Parts for Vickers® DSV2-8 Shuttle Valve Cartridges


Catalog Price Indexes & Technical Information
Part No. Part Number Description Wt. Each
C1FV34 02-160755 Buna-N Seal Kit for C-8-3 Cartridge 0.01

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
407
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Truck Valves
Hydraulic Power & Control

Truck Valves
Pneumatic Power & Control

Typical Application: Used extensively in the trucking industry for cooling and fuel line applications.
Material: Forged brass bodies, steel handles, Buna-N o-ring.
Pressure Rating: 200 PSI Maximum.
Temperature Range: -40°F to 250°F.
Conformance: Designed for trucking use. Not intended for natural gas, LPG, nuclear or aircraft applications.
Truck Valves
Catalog Price
Part No. Eaton Model Description Wt. Each
•C1JE95 7508 1/2 Female NPT x 1/2 Male NPT 0.45
Fluid Conveying
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
408
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Bolt Kits & Bolt Extenders

Hydraulic Power & Control


Valve Mounting Bolt Kits

Valve Mounting Bolt Kits


Catalog Vickers Price
Part No. Part No. Vickers Model Bolt Qty Bolt Size Wt. Each
•C1BW14 590716 BK590716 4 10-24 x 1-1/4 0.05
•C1CA49 870017 BK870017 4 10-24 x 2-3/4 0.10
•C1BQ65 466851 BK466851 4 10-24 x 3-1/2 0.12
C1BQ66 466853 BK466853 4 10-24 x 4-5/16 0.13

Pneumatic Power & Control


•C1BH34 255633 BKDG01-633 4 1/4-20 x 1-1/2 0.10
C1JD87 255654 BK255654 4 1/4-20 x 3-1/2 0.43
C1KK36 464125 BK464125M 4 M5 x 70 0.10
C1HZ89 466837 BK466837M 4 M5 x 80 0.12
A: Bolt length in directional valve, blanking plate, crossover plate, etc.
• DG4V-3 & DG4V-3S Valves: A = 0.86 inches
• DG4S4-01 Valves: A = 1.13 inches
• DG5S-8 & DG5V-8 Valves: A = 1.69 inches
B: Height of intermediate valve stack, if any.
C: Depth of thread engagement in subplate or manifold.
• 10-24 Bolt Threads: 0.39 inch required engagement
• 1/4-20 Bolt Threads: 0.37 inch required engagement
• 1/2-13 Bolt Threads: 0.81 inch required engagement

Fluid Conveying
L: Required bolt length.

SystemStak™ Bolt Extender Kits (NFPA D05 Size Valves)

Miscellaneous Products
SystemStak™ Bolt Extender Kits (NFPA D05 Size Valves)
Catalog Vickers Vickers Extender SystemStak™ Valve Price
Part No. Part No. Model Qty Height (in) Wt. Each
C1DX61 525744 BKE-4-50M 4 1.97 0.18

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
409
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Cartridge Valve Housings
Hydraulic Power & Control

Vickers® 2-Way Cartridge Valve Housings


C-*-2 Cavity Size Models
Pneumatic Power & Control

Vickers® 2-Way Cartridge Valve Housings • C-*-2 Cavity Size Models


Catalog Vickers Price
Part No. Model Cavity Type Port 1 Port 2 A (in) B (in) C (in) D (in) E (in) F (in) G (in) H (in) Wt. Each
Fluid Conveying

C1ZZ83 02-160731 C-8-2 FR SAE-6 SAE-6 2.0 0.75 2.00 0.28 0.50 0.13 0.61 1.50 0.50

C1BT57 566201 C-10-2 STD 1/4 NPT 1/4 NPT 2.0 0.75 2.00 0.28 0.50 0.125 0.75 1.25 0.38
(20055)
C1AD20 02-161382 C-10-2 STD 3/8 NPT 3/8 NPT 2.0 0.75 2.00 0.28 0.50 0.125 0.75 1.25 0.37
(20056A)
566151
•C1BT51 (20057A) C-10-2 STD SAE-6 SAE-6 2.0 0.75 2.00 0.28 0.50 0.125 0.75 1.25 0.38
566189
•C1BT56 (20054) C-10-2 STD 1/2 NPT 1/2 NPT 2.0 0.75 2.00 0.28 0.50 0.125 0.75 1.25 0.35
Miscellaneous Products

566150
•C1BT50 (20058AA8) C-10-2 STD SAE-8 SAE-8 2.0 0.75 2.00 0.28 0.50 0.125 0.75 1.25 0.36
02-160645
C1HL18 has C-12-2U FR SAE-12 SAE-12 3.50 1.75 3.50 1.00 0.50 2.00 2.00 1.99
undercut
•C1AD22 02-161405 C-16-2 STD 3/4 NPT 3/4 NPT 3 1.125 3.00 0.34 0.75 0.16 1.00 1.875 1.25
(20458)
•C1BT49 566149
(20460AA8) C-16-2 STD SAE-12 SAE-12 3 1.125 3.00 0.34 0.75 0.16 1.00 1.875 1.23

C1ET92 566409 C-20-2 STD SAE-16 SAE-16 3.5 1.35 3.50 0.34 0.85 0.16 1.45 2.70 2.42
Types: STD (Standard light-duty aluminum 3000 psi maximum) FR (Fatigue-rated aluminum 3000 psi maximum) S (Ductile Iron 5000 psi
maximum)
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
410
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Cartridge Valve Housings

Hydraulic Power & Control


Vickers® 3-Way Cartridge Single Valve Housings
3-Port Cavity Size Models

Pneumatic Power & Control


Vickers® 3-Way Cartridge Single Valve Housings • 3-Port Cavity Size Models
Catalog Vickers Price

Fluid Conveying
Part No. Model Cavity Type Port 1 Port 2 Port 3 A (in) C (in) E (in) F (in) G (in) H (in) Wt. Each
C1MG53 410AA00016A A12336 STD SAE-8 SAE-8 SAE-4 3.00 2.76 0.48 0.39 0.71 1.42
C1MG89 B10922 A12336 S SAE-8 SAE-8 SAE-4 3.00 2.76 0.48 0.39 0.71 1.42
410AA00020A
C1JZ96 (B11946) A20081 STD SAE-16 SAE-16 SAE-4 3.54 4.00 0.74 0.49 0.87 1.81 2.70
C1MG92 B11947 A20081 S SAE-16 SAE-16 SAE-4 3.54 4.00 0.74 0.49 0.87 1.81
410AA00012A
C1JZ92 (B24257) A22903 STD SAE-6 SAE-6 SAE-4 2.50 2.50 0.85 0.47 0.43 0.93 0.80

Miscellaneous Products
C1LB64 BXP10536 A6610 STD SAE-6 SAE-6 SAE-4 2.50 2.36 0.36 0.35 0.45 1.04
C1MG95 B7884 A6610 STD SAE-8 SAE-8 SAE-4 2.50 2.36 0.36 0.35 0.45 1.04
410AA00022A
C1JZ98 (B10630) A6935 STD SAE-20 SAE-20 SAE-4 3.82 4.00 0.41 0.33 0.93 1.93 2.60
C1MG90 B11474 A6935 S SAE-20 SAE-20 SAE-4 3.82 4.00 0.85 0.33 0.93 1.93
C1JZ91 410AA00008A A878 STD SAE-12 SAE-12 SAE-12 3.00 3.86 1.75 0.51 1.23 1.23 1.60
(B10623)
•C1AD16 02-160742 C-8-3 FR SAE-6 SAE-6 SAE-6 2.50 2.62 0.51 0.13 0.61 1.17 0.86

•C1BT54 566162 C-10-3 STD SAE-6 SAE-6 SAE-6 2.50 2.625 0.50 0.125 0.75 1.375 0.65
(20197AA8)

C1BT58 566275 C-10-3 STD 3/8 NPT 3/8 NPT 3/8 NPT 2.50 2.625 0.50 0.125 0.75 1.375 0.56
(20196)
C1EX76 566413
Indexes & Technical Information
(30472A8) C-10-3S STD SAE-6 SAE-6 SAE-6 2.50 2.625 0.50 0.125 0.75 1.375 0.85

•C1AD19 02-160853 C-10-3S STD SAE-8 SAE-6 SAE-6 2.97 3.22 0.56 2.58 1.28
876712
C1FP96 (23112A8) C-10-3S FR SAE-8 SAE-8 SAE-6 3.00 3.00 0.75 0.37 0.66 1.32 1.50

02-178269
C1FQ53 (31106A8) C-12-3S FR SAE-12 SAE-12 SAE-6 3.50 4.00 0.50 0.50 0.91 1.66 1.80

Types: STD (Standard light-duty aluminum 3000 psi maximum) FR (Fatigue-rated aluminum 3000 psi maximum) S (Ductile Iron 5000 psi
maximum)
Note: Mounting hole style and location may vary from diagram.
Note: Part Number 02-160853 and 410AA00008A is a four port valve (C1, C2, V1, V2) for use with a counterbalance valve. The pilot cavity is
connected to ports V2 and C2.

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
411
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Cartridge Valve Housings
Hydraulic Power & Control

Vickers® 3-Way Dual Cartridge Valve Housings


3 Port Cavity Models
Pneumatic Power & Control
Fluid Conveying

Vickers® 3-Way Dual Cartridge Valve Housings • 3 Port Cavity Models


Catalog Price
Part No. Vickers Model Cavity Type Ports A (in) B (in) C (in) D (in) E (in) F (in) G (in) H (in) Wt. Each
410AA00017A
C1MG54 (C10807) A12336 STD SAE-8 3.00 5.00 1.50 0.43 1.42 1.59 3.41 5.47

C1MH17 C11561 A12336 FR SAE-8 3.00 5.00 1.50 0.43 1.42 1.59 3.41 5.47
C1MH19 C30105 A20081 STD SAE-16 3.00 5.00 1.50 0.43 1.42 1.59 3.41 5.47
C1MG93 B30237 A6610 STD SAE-8 2.50 4.00 1.25 0.35 1.04 1.25 2.75 4.37
Miscellaneous Products

410AA00015A
C1JZ95 (B10805) A6610 STD SAE-6 2.50 4.00 1.25 0.35 1.04 1.25 2.75 4.37 0.90
C1MH18 C11564 A6935 FR SAE-20 4.00 5.00 3.82 0.43 1.93 1.26 3.74 6.08
•C1AD18 02-160830 C-10-3S STD SAE-8 3.47 3.97 1.97 0.34 2.00 1.25 2.68 5.90 0.50
Types: STD (Standard light-duty aluminum 3000 psi maximum) FR (Fatigue-rated aluminum 3000 psi maximum) S (Ductile Iron 5000 psi
maximum)
Note: Mounting hole style and location may vary from diagram.
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
412
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Cartridge Valve Housings

Hydraulic Power & Control


Vickers® 4-Way Cartridge Valve Housings
C-*-4 Cavity Size Models

Pneumatic Power & Control


Vickers® 4-Way Cartridge Valve Housings • C-*-4 Cavity Size Models
Catalog Vickers Price

Fluid Conveying
Part No. Model Cavity Type Port 1 Port 2 Port 3 Port 4 A (in) C (in) E (in) F (in) G (in) H (in) Wt. Each

C1FE80 566190 C-10-4 STD 3/8 NPT 3/8 NPT 3/8 NPT 3/8 NPT 2.50 3.25 0.375 0.125 0.75 1.375 0.78
(20206BA8)
•C1BT53 566161 C-10-4 STD SAE-6 SAE-6 SAE-6 SAE-6 2.50 3.25 0.375 0.125 0.75 1.375 0.79
(20207BA8)
Types: STD (Standard light-duty aluminum 3000 psi maximum) FR (Fatigue-rated aluminum 3000 psi maximum) S (Ductile Iron 5000 psi
maximum)

Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
413
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Cartridge Valve Coils
Hydraulic Power & Control

Vickers® Cartridge Valve Coils


Pneumatic Power & Control

Vickers® Cartridge Valve Coils


Catalog Price
Part No. Vickers Part No. Vickers Model Series Voltage Connector Other Features Wt. Each
Fluid Conveying

C1JY62 300AA00121A MCSCH012DG000010 H Series 26 Watt 12VDC DIN 43650 0.60


C1JY63 300AA00122A MCSCH024DG000010 H Series 26 Watt 24VDC DIN 43650 0.50
•C1AD35 02-178104 SC024SPJ00 J Series 20 Watt 24VAC 1/2 NPT Conduit 1.00
•C1AD36 02-178106 SC120APJ00 J Series 20 Watt 120VAC 1/2 NPT Conduit Full Bridge Rectifier 1.00
•C1JY60 300AA00085A MCSCJ115AG000010 J Series 20 Watt 120VAC DIN 43650 Full Bridge Rectifier 0.50
C1JY61 300AA00086A MCSCJ230AG000010 J Series 20 Watt 230VAC DIN 43650 Full Bridge Rectifier 0.51
C1AD37 02-178109 SC240APJ00 J Series 20 Watt 240VAC 1/2 NPT Conduit Full Bridge Rectifier 0.75
•C1AD31 02-178078 SC012DPJ00 J Series 20 Watt 12VDC 1/2 NPT Conduit 1.00
Miscellaneous Products

•C1JY58 300AA00081A MCSCJ012DG000010 J Series 20 Watt 12VDC DIN 43650 0.61


•C1KJ80 300AA00095A MCSCJ012DW0B0010 J Series 20 Watt 12VDC Flying Lead 0.60
•C1AD32 02-178079 SC024DPJ00 J Series 20 Watt 24VDC 1/2 NPT Conduit 2.00
•C1JY59 300AA00082A MCSCJ024DG000010 J Series 20 Watt 24VDC DIN 43650 0.50
•C1KJ81 300AA00096A MCSCJ024DW0B0010 J Series 20 Watt 24VDC Flying Lead
C1LX16 300AA00045A MCSCP115AG000010 P Series 23 Watt 115VAC DIN 43650
C1LX17 300AA00046A MCSCP230AG000010 P Series 23 Watt 230VAC DIN 43650
C1KJ79 300AA00042A MCSCP024DG000010 P Series 23 Watt 24VDC DIN 43650 0.34
C1KU72 300AA00005A MCSCS115AG000010 S Series 20 Watt 115VAC DIN 43650 0.30
•C1KJ78 300AA00009A MCSCS012DQ000010 S Series 20 Watt 12VDC 1/4" Spade 0.30
C1JL52 02-160691 SC024DGS00 S Series 16 Watt 24VDC DIN 43650 0.34
Indexes & Technical Information

Protection of Internally Rectified AC Coils: The rectifiers used in AC coils may require protection from high voltage surges in some electrical
circuits containing highly inductive or capacitive components. These include certain types of motors, solenoids, relays and transformers.
Protection is simple and inexpensive. It consists of installing a commercially available voltage surge suppressor like the GE MOV Varistor
V130LA20A for 115VAC or the V250LA20A for 230VAC across the AC line supplying the rectified components. A single suppressor will
normally protect all of the rectified components in the circuit. (See circuit diagram above. No inductive or capacitive loads can be installed
between the surge suppressor and rectified valves).

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
414
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Solenoid Valve Connectors

Hydraulic Power & Control


DIN 43650 / ISO 4400 Solenoid Connectors
Canfield Series 5000 • Strain Relief Style
Connector for solenoid valves using the DIN 43650 / ISO 4400
specification. This standard permits industry interchangeability
and has been embraced by the solenoid valve industry worldwide.
Features: Cable outlet can be assembled in 90° increments.
Indicator lights and pre-wired options are available. Available in
Black, Gray or Translucent (for models with lights).

Pneumatic Power & Control


Maximum Rated Voltage: 300 VDC / 250 VAC @ 50/60 Hz.
Maximum Cable Diameter: 0.41 inches (See table for cable
diameter range).
Maximum Current Rating: 10 amps.
Maximum Rated Temperature for Gasket: Nitrile gasket -13°F to 194°F. Silicone
gasket -40°F to 257°F.
Environmental Rating: Nema Type 4 and IP65 dust tight and water resistant.
Normal Polarity: 1 = Positive. 2 = Negative.

Fluid Conveying
DIN 43650 / ISO 4400 Solenoid Connectors • Canfield Series 5000 • Strain Relief Style
Wire
Catalog Length Gasket Wire Cable Dia. Price
Part No. Canfield Model Ground (ft) Lights Material Contacts Housing Color Type (in) Wt. Each
0.236 to
•C1BS52 5100-10900 Down -- -- Nitrile 2+Ground Black -- 0.315 0.25

Miscellaneous Products
6-48
•C1FK20 5103-1090000 Down -- VAC/VDC Nitrile 2+Ground Translucent -- 0.315 to 0.05
0.394
50/60 Hz

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
415
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Solenoid Valve Connectors
Hydraulic Power & Control

All-Molded DIN Solenoid Connectors


Canfield Series 5J
The Canfield Series 5J all-molded DIN solenoid
valve connector/gasket/cord assembly offers a
completely molded design that is far better for
environmental integrity than field wire versions.
Made from rugged yet flexible polyurethane, the
connector housing boasts high durability factors
Pneumatic Power & Control

and application versatility. The low profile “90°” interface/cord configuration allows
for installation in many limited space applications. The integrated gasket design
boasts an IP67/NEMA 6 rating and makes it impossible to lose the gasket.
Maximum Rated Voltage: 250VAC 50/60 Hz, 300VDC.
Maximum Rated Current: 10 amps (ISO and Mini), 6 amps (Sub Micro).
Ambient Temperature Rating: -13°F to 176°F.
Environmental Rating: IP67 and NEMA 6, dust tight and water resistant.
Cable Conductor Colors: White black & green (US), brown blue & yellow/green (European).
Conductor Wire Size: 18 gauge (ISO & Mini), 20 gauge (Sub Micro).

All-Molded DIN Solenoid Connectors • Canfield Series 5J


Fluid Conveying

Cord
Catalog Connector Length Operating Suppression Wire Housing Price
Part No. Canfield Model Type (ft) Contacts Voltage Type Lights Option Color Wt. Each

•C1HW97 5J664-000-US0A ISO DIN 6 ft 2 + Dual -- None No US Black 0.32


43650 Ground
Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
416
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Solenoid Valve Connectors

Hydraulic Power & Control


MINI Solenoid Connectors
Canfield Series 5000
The Canfield Connector field wireable MINI solenoid valve connector
is a high quality interconnection device for use with solenoid valves
and pressure switches. The connector features a PG9 strain relief,
3/8" or 1/2" conduit wire pass through, all with screw terminals for wire
connections. The MINI accommodates wire from .240" to .410"
diameter as a standard with an AWG of 14 maximum. Environment

Pneumatic Power & Control


resistance of NEMA 4 / IP 65 along with versions which are CSA
approved ensure long trouble free service. Current maximum of 10
Amps and the temperature rating of -40° to +125°C encompasses
most applications. The interface is an industry standard.
Features: Cable outlet can be assembled in 180° increments. Indicator lights and
pre-wired options are available. Available in Black, Gray or Translucent (for models
with lights).
Maximum Rated Voltage: 300 VDC / 250 VAC @ 50/60 Hz.
Maximum Cable Diameter: Strain Relief - 0.240 to 0.310 inches max. Conduit - 0.410
inches max. 14 AWG max conductor wire.
Maximum Current Rating: 10 amps.
Maximum Rated Temperature for Gasket: Nitrile gasket -13°F to 194°F. Silicone

Fluid Conveying
gasket -40°F to 257°F.
Environmental Rating: Nema Type 4 and IP65 dust tight and water resistant.
Normal Polarity: 1 = Positive, High. 2 = Negative, Neutral

MINI Solenoid Connectors • Canfield Series 5000

Miscellaneous Products
Wire
Catalog Length Gasket Housing Wire Cable Dia. Price
Part No. Canfield Model Ground (ft) Lights Material Connector Type Color Type (in) Wt. Each
•C1HZ99 5100-1030000 Down -- -- Nitrile 1/2 NPT Black -- 0.03

Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
417
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Subplates, Manifolds & Accessories
Hydraulic Power & Control

Side Ported Subplates • NFPA D03 - ISO 4401 Size 03


Pneumatic Power & Control

Side Ported Subplates • NFPA D03 - ISO 4401 Size 03


Catalog Pressure Rating Price
Part No. Daman Model Material (psi) Port Location Port Threads A B Wt. Each
C1CG87 A-D03-SP-S-6P Aluminum 3000 Side 3/8 NPT 1.00 2.50 0.23
C1CG88 A-D03-SP-S-6S Aluminum 3000 Side SAE-6 1.00 2.50 0.23
Fluid Conveying

Subplate Mounting Hardware Included: (2) 1/4-20 x 7/8 Socket Head Cap Screws

Dual Ported Subplates • NFPA D03 - ISO 4401 Size 03


Miscellaneous Products

Dual Ported Subplates • NFPA D03 - ISO 4401 Size 03


Catalog Pressure Rating Price
Part No. Daman Model Material (psi) Port Location Port Threads A B C Wt. Each
Side P-T-A-B,
•C1JF14 AD03SPSB6S Aluminum 3000 Bottom P-T SAE-6 1.50 2.50 3.44 1.12

C1EK42 AD03SPSB8S Aluminum 3000 Side P-T-A-B, SAE-8 2.00 2.75 3.75 1.80
Bottom P-T
Subplate Mounting Hardware Included: (2) 1/4-20 x 1-1/2 Socket Head Cap Screws. (2) SAE-6 Hex Socket Plugs.
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
418
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Subplates, Manifolds & Accessories

Hydraulic Power & Control


Bottom Ported Subplates • NFPA D03 - ISO 4401 Size 03

Pneumatic Power & Control


Bottom Ported Subplates • NFPA D03 - ISO 4401 Size 03
Pressure
Catalog Vickers Rating Port Price
Part No. Part No. Vickers Model Material (psi) Location Port Threads Wt. Each

Fluid Conveying
C1BQ64 466731 DGVM-3-10S Cast Iron 3600 Bottom SAE-8 3.03

Parallel Circuit Manifolds • NFPA D03 - ISO 4401 Size 03

Miscellaneous Products
Indexes & Technical Information

Parallel Circuit Manifolds • NFPA D03 - ISO 4401 Size 03


Pressure Number
Catalog Rating of Valve Gauge Price
Part No. Daman Model Material (psi) Stations Spacing Port Port Threads and Options A Wt. Each
1/2 NPT P & T, 3/8 NPT A &
•C1CG84 A-D03-P-02-2-P Aluminum 3000 2 2.13 Yes B, 1/4 NPT Gauge Port 4.25 3.95
SAE-10 P & T, SAE-8 A & B,
SAE-6 Gauge Port. With
C1JN34 A-D03-P-03-2-S/C Aluminum 3000 3 2.13 Relief Cavity (C-10-2 6.38 5.39
Common Cavity, P in Nose)
Manifold Mounting Hardware Included: (8) 5/16-18 x 5/8 Hex Head Cap Screws and (2) Steel Brackets.

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
419
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Subplates, Manifolds & Accessories
Hydraulic Power & Control

Parallel Circuit Cover Plates • NFPA D03 - ISO 4401 Size 03

Parallel Circuit Cover Plates • NFPA D03 - ISO 4401 Size 03


Pneumatic Power & Control

Catalog Price
Part No. Daman Model Material Pressure Rating (psi) Gauge Port (P) Wt. Each
C1CG83 A-D03-CP-P Aluminum 3000 No 0.23
Cover Plate Mounting Hardware Included: (4) 10-24 x 1 Socket Head Cap Screws, (4) -012 Viton® 75 durometer O-Rings and (1) 0.12 dia x
0.25 long Locating Pin.
Fluid Conveying

Dual Ported Subplates • NFPA D05 - ISO 4401 Size 05


Miscellaneous Products

Dual Ported Subplates • NFPA D05 - ISO 4401 Size 05


Pressure
Catalog Rating Price
Part No. Daman Model Material (psi) Port Location Port Threads Wt. Each
•C1CG90 A-D05-SP-SB-8S Aluminum 3000 Side P-T-A-B, Bottom P-T SAE-8 2.49
Subplate Mounting Hardware Included: (2) 3/8-16 x 1-1/2 Socket Head Cap Screws. (2) SAE-8 Hex Socket Plugs.
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
420
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Subplates, Manifolds & Accessories

Hydraulic Power & Control


Parallel Circuit Manifolds • NFPA D05 - ISO 4401 Size 05

Pneumatic Power & Control


Parallel Circuit Manifolds • NFPA D05 - ISO 4401 Size 05
Pressure Number
Catalog Rating of Valve Gauge Price
Part No. Daman Model Material (psi) Stations Spacing Port Port Threads and Options A Wt. Each
SAE-12 P & T, SAE-8 A & B,
SAE-6 Gauge Port. With
C1GL55 A-D05-P-02-3-S/C Aluminum 3000 2 3.25 Yes Relief Cavity (C-10-2 6.50 7.25

Fluid Conveying
Common Cavity, P in Nose)
Manifold Mounting Hardware Included: (8) 5/16-18 x 5/8 Hex Head Cap Screws and (2) Steel Brackets.

Miscellaneous Products
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
421
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com
Hydraulic Valves & Accessories
Electronic Control Components
Hydraulic Power & Control

Power Plugs For Proportional Valves


Vickers® EHH-AMP-702-D/E/J/K 10 Series
Description: Note: The newer 20 Series Power Plug is the current design and has
additional features. Designed for use with non-feedback valves, these power plugs
conform to the DIN 43650/ISO 4400 interface and include an integral amplifier and
necessary adjustment potentiometers. This combination offers low cost solutions to
many hydraulic control applications requiring proportional control.
Features: Integral amplifier provides essential functions for control of proportional
Pneumatic Power & Control

valves. Fully short-circuit and reverse-polarity protected.


Application: Primary applications are in the control of directly operated, non-feedback proportional valves where
the cost of more sophisticated electronic controls can be avoided.
For Use With Valves: KDG4V-3(S)-H*-6*, KTG4V-3(S)-H*-6*, KDG4V-5-H*-3*, KTG4V-5-H*-3*.
Note: Vickers publication GB-2115C provides the additional technical information necessary for proper application
of these power plugs. Contact us for technical assistance or to request a copy.
Fluid Conveying
Miscellaneous Products

Power Plugs For Proportional Valves • Vickers® EHH-AMP-702-D/E/J/K 10 Series


Catalog Vickers Price
Part No. Part No. Vickers Model Type Description Wt. Each

C1EV31 02-326010 EHH AMP 702 D 10 D Controlled with 0-10 Volt command signal, 50ms to 600ms 0.22
adjustable ramp time.
Indexes & Technical Information

This page is part of a complete catalog which contains technical and safety data that must be reviewed when selecting a product
422
 1999-2014 Hydraulic Supply Co. • 1-800-507-9651 • www.hydraulic-supply.com