1. GENERAL INFORMATION
IUPAC Name:                  1-phenyl-2-(1-pyrrolidinyl)-1-pentanone
CFR:                         Not Scheduled (01/2013)
CAS #:                       14530-33-7 (base); 5485-65-4 (HCl)
Synonyms:                    -pyrrolidinopentiophenone, α-pyrrolidinovalerophenone , O-2387
Source:                      DEA Reference Material Collection
Appearance:                  White powder (HCl)
Kovat’s Index:               Pending
UVmax (nm):                  253.0
2. CHEMICAL AND PHYSICAL DATA
2.1 CHEMICAL DATA
          Form        Chemical Formula             Molecular Weight             Melting Point (°C)
          Base             C15H21NO                      231                      Not Determined
          HCl            C15H21NO .HCl                   267                           161.3
                                         Page 1 of 6
 3. ADDITIONAL RESOURCES
 Forendex
 Wikipedia
 4. QUALITATIVE DATA
 4.1 NUCLEAR MAGNETIC RESONANCE
 Method NMR D2O
 Sample Preparation: Dilute analyte to ~10 mg/mL in D2O containing TSP for 0 ppm reference and maleic acid
 as quantitative internal standard.
Instrument:                           Varian Mercury 400 MHz NMR spectrometer with proton detection probe
Parameters:                           Spectral width: at least containing -3 ppm through 13 ppm
                                      Pulse angle: 90°
                                      Delay between pulses: 45 seconds
                                      Number of scans (NT): 8
                                      Number of steady state scans: 0
                                      Oversampling: 4 or more
                                      Shimming: automatic gradient shimming of Z1-4 shims
                                      Phasing, Drift Correction: automatic or manual
                                                Page 2 of 6
Page 3 of 6
4.2 GAS CHROMATOGRAPHY/MASS SPECTROMETRY
Sample Preparation: Dilute analyte to ~1 mg/mL in MeOH.
Instrument:                      Agilent gas chromatograph operated in split mode with MS detector
Column:                          DB-1 MS; 30m x .25mm x .25m
Carrier Gas:                     Helium at 1 mL/min
Temperatures:                    Injector: 280°C
                                 MSD transfer line: 280°C
                                 MS Source: 230°C
                                 MS Quad: 150°C
                                 Oven program:
                                 1) 100°C initial temperature for 1.0 min
                                 2) Ramp to 300°C at 12°C/min
                                 3) Hold final temperature for 9.0 min
Injection Parameters:            Split Ratio = 20:1, 1 µL injected
MS Parameters:                   Mass scan range: 30-550 amu
                                 Threshold: 100
                                 Tune file: stune.u
                                 Acquisition mode: scan
Retention Time:                  10.208 minutes
                                              Page 4 of 6
4.3 INFRARED SPECTROSCOPY (FTIR)
Instrument:         FTIR with diamond ATR attachment (3 bounce)
Scan Parameters:    Number of scans: 32
                    Number of background scans: 32
                    Resolution: 4cm-1
                    Sample gain: 8
                    Aperture: 150
                                      Page 5 of 6
Page 6 of 6